Airports Authority Of India Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Airports Authority Of India - AAI Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date16 Jan 2024
Closing Date30 Jan 2024
Tender Amount₹ 61,20,266 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 2.0 TR High wall Split type Airconditioners not less than 5 star rating copper coil, inverter type fitted with extra powerful rotary compressors, gold fin, choas logic operating including remote on regfrigerant R-410A/R-32/R-134 non CFC suitable for wall mounting confirming to IS: 1391 / Part – 21/92 Amdt. No. 1 (except power consumption norms) with 15 feet refrigeration pipes and suitable copper cable and having features like auto air swing (2 way swing), speed setting(3/3), operation control (electronic), auto restart, on timer, evaporator type (2 bend eva) suitable for operation on 230V +/-10%, 50 Hz, single phase AC supply capable of performiong:-(a) Cooling (b) Dehumidifying (c) Air-circulating (d) Filtering (anti-bacteria). Items as per preferred make .

23

-

-

... More
Supply of 4.0 TR capacity floor standing tower type Split AC unit fitted with hermetically sealed compressor operating on 415V +/-10% ,50 Hz, 3 phase AC supply with evaporator and condensing unit made of copper tubes with aluminium fins i/c cordless remote control, Angle iron floor stand for indoor unit, Angle iron wall / floor stand for condensing unit, etc. complete as required. Items as per preferred make .

2

-

-

... More
Subhead -II

-

-

-

... More
Supply of XLPE insulated and PVC sheathed 4 core X 4 sq.mm. unarmoured copper cable 1.1 KV grade as per IS - 7098 ( Part - 1 ) 1988, with up-to-date amendments.

300

-

-

... More
Supply of PVC insulated and PVC sheathed 4 core X 2.5 sq.mm. unarmoured copper cable of 1.1 KV grade as per IS - 7098 ( Part - 1 ) 1988, with upto date amendments.

300

-

-

... More
Supply of PVC insulated and PVC sheathed 3 core X 2.5 sq.mm.unarmoured copper cable of 1.1 KV grade as per IS - 7098 ( Part - 1 ) 1988, with upto date amendments.

300

-

-

... More
Installation Testing and Commissioning of 4.0 TR cassette type airconditioners i/c minor necessary civil works as per item no. 1, 3 m of copper piping for suction and discharge, 3 m of power and control cabling and site conditions and making good the same as original finish etc. complete as required.

2

-

-

... More
Installation Testing and Commissioning of 3.0 TR Inverter Mega Split type Airconditioners i/c minor necessary civil works as per item no. 2, 3 m of copper piping for suction and discharge, 3m of power and control cabling site conditions and making good the same as original finish etc. complete as required.

34

-

-

... More
Installation Testing and Commissioning of 2.0 TR Inverter High wall Split type Airconditioners i/c minor necessary civil works as per item no. 3, 3 m of copper piping for suction and discharge, 3m of power and control cabling and site conditions and making good the same as original finish etc. complete as required.

23

-

-

... More
Installation,Testing and Commissioning of 4.0 TR capacity floor standing tower type Split AC i/c minor necessary civil works as per item no. 4, 3 m of copper piping for suction and discharge, 3m of power and control cabling site conditions and making good the same as original finish etc. complete as required.

2

-

-

... More
Supply and laying of hard copper tube for Refrigerant gas circuit of 3.0 TR/2.0 TR Mega Split Air and Tower conditioner complete with all fittings for suction line ( 5/8") and discharge line ( 3/8") with 12 mm. thick rubber insulation on surface / wall / MS supports etc.as required. 1 Running meter include the 1m of discharge and 1m of suction lines.

773

-

-

... More
Supply and laying of hard copper tube of for Refrigerant gas circuit of 4.0 TR cassette/tower type AC complete with all fittings for suction line (3/4") and discharge line ( 5/8") or suitable size with suitable rubber insulation on surface / wall / MS supports, etc. as required. 1 Running meter include the 1m of discharge and 1m of suction lines.

42

-

-

... More
Supply and Installation of required Angle frame for mounting condensing units of 2.0 TR/3.0 TR/4.0 TR capacity with all accessories, etc. complete as required.

23

-

-

... More
Supplying of rated cyclic timer for Air conditioners having 3 Phase AC power supply, suitable for cycle the air conditioners between duty and standby units at predetermined intervals that are settable between 1 to 12 hours, with necessary buttons, display, inbuilt power and control contactors, control circuits, terminals, complete as required.

10

-

-

... More
Supplying of rated cyclic timer for Air conditioners having Single Phase AC power supply, suitable for cycle the air conditioners between duty and standby units at predetermined intervals that are settable between 1 to 12 hours, with necessary buttons, display, inbuilt power and control contactors, control circuits, terminals, complete as required.

10

-

-

... More
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning, etc. as required.

15

-

-

... More
Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning, etc. as required.

10

-

-

... More
Providing and fixing of 20 mm. dia. PVC Plumbing/drain Pipes for 2.0 TR/3.0 TR/4.0 TR cassette/split ACs on surface including all accessories like bends, sockets and water seal joints, etc. complete as required.

575

-

-

... More
Providing and fixing of 32 mm. dia. PVC Plumbing/drain Pipes for 2.0 TR/3.0 TR/4.0 TR cassette/split ACs on surface including all accessories like bends, sockets and water seal joints, etc. complete as required.

2575

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade upto size of 35 sq. mm on surface as required.

825

-

-

... More
Dismantling the existing cassette,window, tower and split type AC completely of different capacities from different locations of the ATS building and transporting to the AAI store/office as per direction of EIC.

43

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.