West Central Railway Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

West Central Railway - WCR Tender

Works
Telecommunication Services
Ireps
Opening Date4 Jan 2025
Closing Date27 Jan 2025
Tender Amount₹ 89,93,218.51 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of Track Relay QBAT (AC immunised relay), 9 Ohm, 4F/2B or 2F/2B along with plug board (Base plate), retaining clips and connectors conforming to BRS:939A, BRS:938, BRS:966, IRS:S34 & IRS:S23. As required at site INSPECTION BY RDSO

4

5689

22757.12

... More
Supply of Phenolic Laminated sheet, resin bonded 10mm thick, grade P3 in standard size of 1.22 x 1.22 Mtr as per spec. No IS 2036 of 1974 . INSPECTION BY CONSIGNEE

20

4092

81857.6

... More
Supply of Apparatus Case with miniature 'E' type locks with keys (1 key per 5 location 08 boxes) of ward Nos. 41 (E type lock & key as per spec. Nos IRS S 30 & RDSO Drg.Nos. SA 3376/M & 3377/M respectively with latest Amendment) on both the doors, duly painted with red oxide.Single case as per Drg Nos WS- 8842/A with latest alteration. INSPECTION BY CONSIGNEE

4

13324

53298.68

... More
Supply of Apparatus Case with miniature 'E' type locks with keys (1 key per 5 location 09 boxes) of ward Nos. 41 (E type lock & key as per spec. Nos IRS S 30 & RDSO Drg.Nos. SA 3376/M & 3377/M respectively with latest Amendment) on both the doors, duly painted with red oxide.Half case as per Drg Nos WS- 8842/A with latest alteration. INSPECTION BY CONSIGNEE

4

12173

48692.2

... More
Supply of Earth Electrode assembly as per Drg.No.NGP/S&T/C/308 INSPECTION BY CONSIGNEE

30

1238

37155.3

... More
Supply of two in two out (4 conductor) Knife edge disconnect terminal block set as per RDSO/SPN/189/2004 with latest amendment. INSPECTION BY CONSIGNEE 12

2000

83

167400

... More
Supply of end plate suitable for disconnect terminal. INSPECTION BY CONSIGNEE

200

12

2500

... More
Supply of steel carrier Din rail suitable for fixing disconnect terminal 1 meter long of dimension 35mm X 7.5 mm, 1mm thickness, unslotted. INSPECTION BY CONSIGNEE 14

100

148

14831

... More
Supply of end stop suitable for disconnect terminal block INSPECTION BY CONSIGNEE

400

10

4376

... More
Supply of Main Signal Post 140 mm outer dia 4.5 Mtr Length as per spec No IRS S 6/81 with latest amendments. INSPECTION BY CONSIGNEE

5

6655

33279.15

... More
Supply of Shunt Signal Post with Base (GI Pipe of 80 mm Dia. Medium class IS Specification IS:1239 Pt-1/1990). INSPECTION BY CONSIGNEE

3

3191

9575.85

... More
Supply of Cast Iron Main signal surface base 140mm as per spec Nos IRS S 10 and Drg 17 Nos 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5 Mtrs long as per RDSO Drg. Nos. SA-23156. & signal front staging complete assembly fo INSPECTION BY CONSIGNEE 18

5

12301

61506.1

... More
Supply of Signal Nos. plates. as per Drg enclosed. INSPECTION BY CONSIGNEE

10

607

6071.5

... More
Supply of Hand Cuff Locks / Godrej Navtal lock with common key.. INSPECTION BY CONSIGNEE

10

331

3318.8

... More
Non Metallic (FRP) colour light signal housing multi unit type for railway signaling 20 suitable for RE area TWO Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Ver. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest INSPECTION BY CONSIGNEE

5

26983

134915.3

... More
Non Metallic (FRP) colour light signal housing multi unit type for railway signaling 21 suitable for RE area THREE Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M (Adv.) and as per SPEC. No. RDSO/SPN/194/2006 Rev.2.0 or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. INSPECTION BY CONSIGNEE

1

28267

28267.96

... More
Supply of position light shunt signal Unit. as per RDSO Nos. SA23840. INSPECTION BY CONSIGNEE 23

4

11143

44574.16

... More
Supply of Offset Bracket 3-1/2" for shunt signal INSPECTION BY CONSIGNEE

3

522

1568.37

... More
Supply of Offset bracket 5 1/2" suitable for 140mm outer dia of main signal. INSPECTION BY CONSIGNEE

2

1165

2331.02

... More
Supply of ARA Terminal Blocks with links made of PBT specn. No. IRS75/2006 (Rev.2) with latest amendments and RDSO Drg. No. SA-23741A. INSPECTION BY RDSO

500

69

34945

... More
Supply of DWC pipe 120 mm outer dia 103.5 mm inner dia made of polyethylene in 6 mtrs. straight lengths along with one coupler for every 6 mtr.as per specn. Is14930 or latest anti rodent and flame retardant. Or as per site requirement. INSPECTION BY CONSIGNEE

240

306

73459.2

... More
Supply of track lead junction boxes as per Drg. Nos. RST11509 made from fiber glass along with terminal blocks. The TLJB should be BLACK in colour. INSPECTION BY CONSIGNEE

30

1293

38804.1

... More
Supply of B type choke to specn.Nos.IRS.S.65/83 with latest amendments. INSPECTION BY CONSIGNEE

4

4490

17960.04

... More
Supply of adjustable Track Feed Resistance, 30 ohms as per RDSO Drg. Nos. SA- 20161-66M/M with latest amendments (with Phenolic moulded base). INSPECTION BY CONSIGNEE

4

1588

6354.64

... More
Supply of Track feed battery chargers of 10A rating to Specn. Nos.IRS:S.89/93 with latest amendment. Charger shall be suitable for charging 80 AH battery. INSPECTION BY RDSO

4

2839

11356.28

... More
Supply of PVC jacketed wire rope for Track Lead connections. PVC jacketed wirerope 31 should be of Galvanised steel wire rope 6 mm dia (6x19 stranded wire withsteel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1970. Reclaimed or recycled material should Not be used. INSPECTION BY CONSIGNEE

500

62

31275

... More
Supply of flexible cable single core multistrend copper conductors, 1x2.5 sq.mm confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY CONSIGNEE

2

22272

44545.86

... More
Supply of QNA1 (AC immunised relay), 8F-8B, 24VDC along with plug board (Base plate), retaining clips and connectors conforming to BRS:931A, IRS:S34 & IRS:S23. INSPECTION BY RDSO

10

4647

46477.9

... More
Supply of flexible cable single core multi strand copper conductors, 1x10sq.mm confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY CONSIGNEE WITH OEM GUARANTY / WARRANTY CERTIFICATE INSPECTION BY CONSIGNEE

0.5

-

61901.39

... More
Supply of flexible cable single core multistrand copper conductors, 1x6 sq.mm confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY CONSIGNEE WITH OEM GUARANTY / WARRANTY CERTIFICATE INSPECTION BY CONSIGNEE

0.5

-

41652.07

... More
Supply of Heat shrinkable straight through joint for UG cables with all accessories as per RDSO spec. no."IRS /TC/77/2012 (rev-3) with amend.-1 &2 or latest for 6 quad cable 0.9mm dia (TSF-3)joint suitable for 6 quad cable. INSPECTION BY RDSO

6

1917

11504.58

... More
Supply of Key Lock Relay AC immunized with different ward combinations (Five set of same ward plate for Point Machine to be supplied with each relay) of Siemens Make working on 60V DC or functional equivalent. INSPECTION BY CONSIGNEE

3

8555

25666.38

... More
Supply of Shunt signal Group (Ref:IRS:S-46). SIEMENS Make (No.RSSK 3526/67) or Equivalent with base Plate & suitable for LED shunt Signal. (Suitable for existing Installation ) INSPECTION BY RDSO

3

67214

201642.33

... More
Supply of Route Group (Ref. IRS:S46 firms specification), of Siemens Make (Nos RSSK 31/0002) or functional equivalent without baseplate. INSPECTION BY RDSO

8

54886

439091.68

... More
Supply of Electric Point Machine (Rotary locking Type) , 110VDC operation (AC 40 immunity 160V) as per RDSO drg. S-11000 with ground connection and clamp lock arrangement suitable or 220mm throw for thick web switches as per IRS-S-24/2002 with amendment 1 or latest. INSPECTION BY RDSO

5

103158

515790.35

... More
Supply of Signal Group 2 Aspect (Ref: IRS: S46 & firm's specification), of Siemens Make (Nos A-RT-RG-A066) or functional equivalent without base plate (Suitable for LED signals). INSPECTION BY RDSO

5

51722

258614.35

... More
Supply of DRS Point Group for PI, (Ref. IRS: S46 firm's specification), of Siemens Make (Nos RSSK 3515/19) or functional equivalent without base plate As per site requirement. INSPECTION BY RDSO

2

53783

107566.66

... More
Supply of Domino units with cover plates as per approved panel diagram, each of size 54 x 34mmcompletely wired up similar to Siemens make. Each domino units should have all the 15 contact terminals wired up. INSPECTION BY CONSIGNEE

20

926

18521.2

... More
Supply of lamp holders , switches, two pin (Backellite type) and bulbs(230V/110V) for location boxes (Anchor make or ISI mark) INSPECTION BY CONSIGNEE

50

84

4209.5

... More
Supply of Time Element Relay (Clock work type) AG timer Siemens Make No. (RSSK 30/0052) or equivalent with timer range up to 120 seconds. INSPECTION BY CONSIGNEE

5

8369

41849.25

... More
Supply of QSPA1, 24VDC, Slow to pick up 8F/4B, alog with plug board (Base plate) retaining clip and connectors confirming to BRS: 933A, IRS:S60 & IRS: S34. INSPECTION BY RDSO

4

5738

22955.2

... More
Supply of low maintenance Lead Acid Secondary Cells 2V/ 80 Amp Hr. as per spec. IRS 88/93 with latest amendments. INSPECTION BY RDSO

15

2059

30887.4

... More
Supply of "S" shape GI bend pipe Medium class, 50 mm dia. and of 1 mtr length, for cable entry in point machines as per Dy CSTE/C/BPL/011 . INSPECTION BY CONSIGNEE

6

257

1543.32

... More
Supply of Pre-wired Crank Handle cum key lock relay box alongwith LEDs, TEKNIC/SIEMENS make push buttons, 8-way terminal strips/wago terminal, string rod, etc.as per Drawing Nos.RST.C.111A INSPECTION BY CONSIGNEE

2

11471

22943.98

... More
Supply of Concrete Cable Route Marker as per drawing SDO/Cable Laying/020 INSPECTION BY CONSIGNEE.

20

323

6460.8

... More
Supply of 24 Fiber cable joint enclosure(SJC)complete with all accessories. INSPECTION BY CONSIGNEE

2

4049

8098.08

... More
Supply of PVC insulated flexible wire 16/0.2 mm dia as per RDSO spec. No. IRS:S-76/89 with latest amendments of various colours.(Red ,black & grey) with OEM guaranty/ warranty certificate. INSPECTION BY CONSIGNEE

1

6509

6509.5

... More
Supply of PVC insulated railway signalling indoor single core [ tinned jumper wire] 1 x 0.6mm dia, different colours, blue: 60%, red:15%, gray: 20% and brown: 5%. with OEM guaranty/ warranty certificate INSPECTION BY CONSIGNEE

5

4098

20490.15

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. With holder 1.6 A (System, Rapid or Malnad Make or similar). INSPECTION BY CONSIGNEE

100

81

8110

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. With holder 0.6A(System, Rapid or Malnad Make). INSPECTION BY CONSIGNEE

100

77

7772

... More
Supply of Relay Plug In type two DC neutral line in mini group housing, complete with 60 base plate consisting of Top relay AC immunized & Bottom relay both AC immunized, each 60V, 5F/3B, contacts, front and back contacts metal to metal conforming to IRS: S46 and firms specification. Siemens make (RSSK 30/0078-1), ABB or functional equivalent As per site requirement INSPECTION BY RDSO

20

11701

234030.4

... More
Supply of Relay Non-AC Immune, plug-in-type, DC Neutral Line 60V4F/4B, 5F/3B, 6F/2B 61 contacts, front and back contacts metal to metal, conforming to IRS: S 46 and firm's specification. The relay housing shall contain two miniature identical relays in mini group housing complete with base plate, INSPECTION BY RDSO

20

9303

186063.6

... More
Supply of Relay Plug In type, two DC neutral line, mechanically interlocked, in mini 62 group housing, complete with base plate each 60V, 4F/4B contacts, front and back contacts metal to metal conforming to IRS: S 46 and firms specification. Siemens make (RSSK 30/0012) or functional equivalent. INSPECTION BY RDSO

10

10565

105651

... More
Supply of push button telephones suitable for connecting with way side equipment and the system mentioned above as per TEC specification no. GR/TEL-02/04 Sept 2002 with latest amendment & from DOT/TEC approved firms. INSPECTION BY CONSIGNEE

40

585

23406.4

... More
Detailed testing of wiring including continuity testing, functional testing, selection table and locking table testing with simulation panel including making panel through in the presence 01 of Rly officials. The item includes wiring of simulation panels as per standard practice. Erection and wiring of simulation panels shall be with contractors own materials. Signal lamps required for simulation panel will be supplied by contractor. The contractor shall hand over the system for railways testing and shall arrange technical man power, wireman and supervisor to facilitate this testing by railway. UNIT- PER Station

1

105374

105374.64

... More
Fixing of ARA /WAGO Terminals and fuse blocks with provision of holes on hylem sheets and fixing by galvanised nuts & bolts.This includes provision of two additional holes on the hylam board on either side for cable conductor entry. The work shall be done as per Engg. at site.

500

21

10530

... More
Termination of cable cores on ARA/ disconnecting type terminal, fuse blocks, 8 way 03 terminals block in the apparatus cases. This includes all associated works of pulling out the cable from underground, dressing of cable, making wiring tree etc. This includes soldering of armour tree/ring of cables and connecting to copper plate through GI wire bus bar in location boxes. The work shall be done as per location plans and instructions of Rly engineer at site.

1000

15

15790

... More
Excavation, casting and plastering (above ground level) of Apparatus case foundation with contractors own Metal Sheet frame, cement, anchor bolts and other materials. Single case as per Drg No JBP/S&T/C/084

4

12560

50240.56

... More
Excavation, casting and plastering (above ground level) of Apparatus case foundation with contractors own Metal Sheet frame, cement, anchor bolts and other materials. Half case as per Drg No JBP/S&T/C/085

4

12196

48785.32

... More
Erection of apparatus cases. This includes filling of location foundation with river bed sand and plastering on top of the sand. Single case

4

1435

5741

... More
Erection of apparatus cases.This includes filling of location foundation with river bed sand and plastering on top of the sand. Half Case.

4

1098

4392.16

... More
Fabrication and fixing of phenolic board in location box by providing all fixtures as per 08 Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. Lasing and dressing of cables/wires terminated with contractors own supply of lasing thread. The work shall be done as per instructions of Rly engineer at site. Single case

4

2028

8115.96

... More
Fabrication and fixing of phenolic board in location box by providing all fixtures as per 09 Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. Lasing and dressing of cables/wires terminated with contractors own supply of lasing thread. The work shall be done as per instructions of Rly engineer at site. Half Case.

4

1828

7314.04

... More
Installation of Eqpt. (Relays, resistance, chargers & batteries etc.) & wiring of the same in apparatus cases as per location & circuit diagrams with contractor's own PVC wires and wiring 10 material. The work shall be done as per instruction of Rly engineer at site and approval of wiring material ( from RDSO approved firms) being used and extant practice in W.C. Rly). Wiring of relays should be with 16/0.2mm wire and all other equipments wiring by 2.5 sq mm multi strand wire of IS 394 of 1990 or latest. Single case

4

1916

7666.52

... More
Installation of Eqpt. (Relays, resistance, chargers & batteries etc.) & wiring of the same in apparatus cases as per location & circuit diagrams with contractor's own PVC wires and wiring 11 material. The work shall be done as per instruction of Rly engineer at site and approval of wiring material ( from RDSO approved firms) being used and extant practice in W.C. Rly). Wiring of relays should be with 16/0.2mm wire and all other equipments wiring by 2.5 sq mm multi strand wire of IS 394 of 1990 or latest. Half case

4

1333

5332.76

... More
Erection, Fitting and Rail connection of Track Lead Junction Box with contractor's fixing material and jacketed wire rope including 7mm single groove galvanized channel pin for track lead connection including angle of size 40 x 40 x 5 mm 1200 mm length. This will include drilling of holes 12 in rails for track lead connections as per instructions of Rly engineer at site. PVC jacketed galvanized steel wire ropes of 6mm dia (7 x 19 strands) sheathed with PVC of 2mm wall thickness and over all thickness of 10mm for connection between the TLJB and the rails are to be used and to be supplied by the contractor. PVC sheath should be made of type 6 compound as per IS 5831 of 1970. Double wire ropes are to be connected between each rail and TLJB.

30

1710

51309.6

... More
Provision of bonding with contractor's materials including 7mm single groove 13 galvanized channel pin. This will include drilling of 7.2 mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own materials and tools as per instruction of Rly engineer at site GI wires of 4mm dia (8 SWG) are to be used for jumpers across fish plates which should be supplied by the contractor free of cost.

300

226

67881

... More
Fixing of point machine on newly laid turnout on Wooden/MBC/Steel sleepers & fixing of ground connections. Adjustment and testing with crank handle operations. This will include fixing of bend pipes with welded frame for cable entry to machine. This will also includes necessary adjustment and smithy work, drilling of Holes to tongue rails, gauge plate & steel sleeper, fitting of 14 insulation for tongue attachment, gauge plate & William stretcher. This also includes cable entry to the point machine and termination of tail cable in point machine on ARA terminals and wiring of point machine (Necessary wiring modification for independent detection) using 2.5 sq mm insulated copper wire as per IS 696 of 1990 with suitable lugs. ARA terminals are to be suitably fixed on channels inside point machine .Supply & filling of SAE 30 lubricating oil (500ml approx). The work shall be done as per extant practice on W.C. Rly & the instruction of Rly engineer at site. Per Unit = Per Turnout

5

4676

23381.15

... More
Fixing of Electrical high thrust(220mm) point machine on the extended sleepers at thick web point as per section of rails used. Item included fixing of switch extension bracket, fixing ground connection, adjusting opening of the switches and adjusting of the point machine with crank handle .The item also includes(i) Complete material for installation of point machines and fixing of 15 ground connection/switches extension bracket like point insulator materials, S pipe, wiring materials Various fixing nuts & bolts including casting nuts, spring washers, etc. (ii)All smithy & fitting works required at site for complete installation.(iii)Installation of gauge tie plate &providing insulation for gauge tie plate. (iv)Wiring inside the point machine, insertion and termination of tail cable in point machine and junction box /cable hut as per extent practice of WCR and the instruction of railway Engineer at site. Electricals point machine, ground connection and M6 Screw less terminals will be supplied by Railways, covered in Schedule separately.

1

22981

22981.31

... More
Excavation of trench as per cable route plan, 1.2 mtr deep, 300mmwide at the bottom along main line in normal soil, This work includes covering of cable laid in trenches by loose soil for a 16 layer of 50 mm thickness approximately before covering by stone/bricks , clearing of route, bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.

1.5

86227

129341.87

... More
Excavation of trench as per cable route plan, 1 mtr deep, 300mm wide at the bottom along main line in hard soil / murrum, This work includes covering of cable laid intrenches by loose soil for a layer of50 mm thickness approximately before covering by stone/bricks.

0.5

-

61590.17

... More
Excavation of cable trench 1m deep and 300mm wide across the track, for track crossing and refilling after laying of DWC/RCC/GI pipes. The work shall be done as per extant practice on W.C. Rly & instruction of Rly engineer at site.

180

185

33431.4

... More
Cutting of all types of Roads preparatory to trenching & excavation to depth of 1 Mtr X 19 300 mm wide approximately and refilling, after laying of GI pipe and to restore the road to original condition. The work shall be done as per extant practice on W.C.Rly & instruction of Rly engineer at site.

150

307

46141.5

... More
Preparation of cable duct 150mm x 300mm deep for laying of cable in rocky area and 20 refilling the duct (after cable laying) with concrete mixture of proportion 1:3:6 and grouting the ends at either side of the rocky portion using concrete mixture with contractors own cement and other materials.

240

800

192223.2

... More
Supply & laying of well burnt bricks of size 225x100x75mm inside the trench (with the brick length being perpendicular to cable route) after laying of cable in station area from Outermost 21 to Outermost signal or at any other location as per instruction of Site Engineer. Note: - Size of bricks to be got approved by Site Engineer. In case brick size is in variance with the size given in the tender schedule then proportionate payment on volumetric basis shall be paid to contractor subject to a maximum limit of schedule rate.

13500

5

78030

... More
Laying of signalling/Power/Telecom cable of various cores/sizes intrenches. This includes transportation of cable to site from depo as nominated

40

9398

375951.2

... More
Transportation & Laying of GI/DWC/RCC pipes along with collars in trenches at places wherever required as per the instruction of the engineer at site.

180

73

13176

... More
Installation & fixing of earth electrode assembly including earth wire connected 24 through GI wire 8 SWG supported on M.S. flat of size 6mm x 40mm to earth electrode for signaling Equipment. Contractor will bring Earth enclosure and all other material required for provision of earthing.

30

1236

37089

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian 26 paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per instructions of Rly engineer at site and extant practice on W.C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases also Termination particulars, equipment names etc. legibly and neatly inside location boxes etc.Appratus case full size

4

466

1867.92

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian 27 paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per instructions of Rly engineer at site and extant practice on W.C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases also Termination particulars, equipment names etc. legibly and neatly inside location boxes etc.Appratus case Half size

4

349

1397.08

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian 28 paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per instructions of Rly engineer at site and extant practice on W.C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases also Termination particulars, equipment names etc. legibly and neatly inside location boxes etc. Shunt Signal post with signal unit, surface base as per W.C. Rly.Standard practice.

2

189

378.12

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per instructions 29 of Rly engineer at site and extant practice on W.C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases also Termination particulars, equipment names etc. legibly and neatly inside location boxes etc. Point machine with ground connection complete. ( Point machine with black enamel only out side and ground connection with red oxide)

5

163

819.95

... More
Lettering numbering of signals, point machine, track lead junction boxes, block joint, appratas cases etc ( each item to be taken as one unit )

20

60

1219.2

... More
Lettering numbering termination particulars, equipments names etc legibly and neatly inside location boxes. Single case

4

283

1132.36

... More
Lettering numbering termination particulars, equipments names etc legibly and neatly inside location boxes. Half case

4

160

641.76

... More
All work pertaining to Horizontal Directional Drilling (HDD)/Boring and trenchless cabling in hard/rocky soil by machine. It includes supply. Transportation and insertion of self 33 lubricated HDPE Pipe and laying of cables in boring under the track road platform circulating area by using self lubricated HDPE Pipe of 120mm outer dia and103.5mm inner dia in the bore. The depth of horizontal boring should be minimum 2 mtr upto3 mtr, from rail flange road level ground level as per site requirement and as per instructions of Railway Engineer incharge. Thickness 3.5to 4.1 mm as per specification no. IS4984:1995 with latest amendment, Material Grade PE 63

120

1978

237376.8

... More
Excavation, casting and plastering (above ground level) of main signal foundation as per Drg.No.WCR/S&T/SIG/01 with contractor's own materials including cement and galvanised anchor bolts of standard size. The hole for cable entry should be kept as per site requirement and instruction of Rly engineer at site. The required scaffolding Ferma etc. for casting of foundation will have to be brought by the contractor at his own cost.

-

-

34

... More
Erection of CLS Post with Surface base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates and A/AG/C/P/G marker board 35 , protective screen, blanking of ladder (0.6mm MS sheet) if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. Wooden white cross- arms (1000x100 mm) to be provided by the contractor till the signals are commissioned with contractor's own material.

5

3860

19304

... More
Termination of tail cable on main & auxiliary signal units and wiring with contractor 36 own material, fixing of LED signal units etc. Flexible Single core copper wire 2.5 sq.mm (50/0.25) conforming to IS-694:1990 (as per aspect colour) and lugs etc. will be supplied by the contractor. This includes insertion of tail cables from ground to signal unit. The work shall be done as per instruction of Rly engineer at site.

5

1212

6062.45

... More
Excavation and Casting of shunt signal foundation as per Drg.No. SK 749 based on 37 drawing no .RST-11173 with contractor's own materials including cement and anchor bolts of standard size. The hole for cable entry should be kept as per site requirement & instruction of railway engineer at site. The required scaffolding, Ferma, etc for Casting of foundation will have to be brought by the contractor at his own cast.

2

3553

7107.52

... More
Erection of shunt signal with Surface Base, Post, Signal unit and fixing of No. plates. 38 The work shall be done as per instructions of Rly engineer at site. Wooden white cross-arms (1000x100 mm) to be provided by the contractor till the signals are commissioned with contractor's own material.

2

632

1264.44

... More
Termination of tail cable on Shunt signal units and wiring with contractor own material, 39 fixing of LED signal unit etc. Flexible Single core copper wire 2.5 sq.mm (50/0.25) conforming to IS- 694:1990 copper wire as per Rly. Standard and lugs etc. will be supplied by the contractor. This includes insertion of tail cables from ground to signal unit. The work shall be done as per instruction of Rly engineer at site.

2

468

936.1

... More
Dismantling and releasing of Colour light signal, Location Box. Which includes 40 dismantling of signal fittings complete & location box fitting complete. All dismantelled materials to be transported and stacked in the store of respective section or as nominated of JBP Div as per consignee.

4

1175

4701.16

... More
Installation, wiring, testing and commissioning of track device of SSDAC/MSDAC/HADAC with all system including digging of trench, track crossing, laying of Double walled antirodent corrugated pipe or other pipe required for completed installation of system from 41 track device to location box and making its terminations. Fixing of deflector plates.(Double walled antirodent corrugated pipe made up of High Density Polyethylene of required dia and all other accessories as per site requirement to be supplied by the firm) & Installation of EJB / Trackside Electronics inside the location (if required), reset box for system, etc. including supply of wires and other accessories. Pre-commissioning checklist to be submitted priorto the commissioning asper RDSO specification. Rate- Per DP

7

12963

90744.71

... More
Supply and installation of earthing arrangement for axle counter DPs of signal location boxes set consist of (i) SS angle of 3X30X200 mm grade 304(ii) SS wire rope of 1X19X12 mm dia SS 42 grade of 2.5 Mtr( Nominal) 316. (iii) SS nut bolt, Washer with check nut (iv) SS lug for crimping 2 nos. (v) Earthing compound as per RDSO specification no. RDSO/SPN/197/2008 Weight 25 KG. (vi) Precast RCC chamber with cover with pulling hook size approx. 300X300X50 mm thik.(Circular or rectangular section) (Material to be inspected by Consignee). SUPPLY PORTION INSPECTION BY CONSIGNEE

10

6464

64649.7

... More
Shifting & adjustment of existing Multi section digital axle counters. (This includes modification in the programming of MSDAC including supply of necessary software)

1

80454

80454.71

... More
Patching work in old location consisting (i) Digging of pit, cleaning of earth from all sides, breaking of seal of location boxes, removal of sand , from location, marking of new cable hole. (ii) Insertion of cable from ground.(iii) making place from cable termination in old location, shifting of ARA, fuse etc. after removal of termination, including shifting of ARA.(iv) Termination of cable in old location.(v) Sand filling and plastering

-

-

44

... More
Supply & installation of powder coated Relay Rack Assembly complete with scaffolding, fixtures and accessories including MS Bars / relay frames for fixing of relay plug boards, string rods, fuse strips with bracket, 11 Way Bus Bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens' type or equivalent & as per extant practice on W.C. 46 Rly. Typical part list as per Annexure-H and Rack arrangement as per Sketch Nos Sk-727 and Rack plan as approved by Engineer incharge. Rack should be made of first class steel powder coated painting and rack manufacturer's certificate should be submitted. All runway for cables / wires shall be provided with PVC sleeve of proper size. Installation of Relay Rack Assembly including IDF pillars complete with wall supports, scaffolding, ladders, runway for cables, Relay/Relay group base plates, fixing of Tag blocks etc. The work shall be done as per approved plan, extant practice on W.C.Railway & the instructions of Rly. engineer at site. SUPPLY PORTION INSPECTION BY CONSIGNEE

4

47931

191725.12

... More
Supply & installation of Main Cable Termination rack complete with scaffolding, fixtures & accessories including square bars for mounting 8-way terminal blocks, ladder, string rods, frame, base assembly, insulators, J bolt, nut/bolts & fasteners ,backelite sheet etc. Siemens type & as 47 per extant practice on C. Rly. Typical part list asper Annexure-V and rack arrangement shall be as per sketchSK 727 with latest alterations. This includes installation of Cable Termination Racks Assembly complete including wall supports, scaffolding, 8 way/ARAterminal/Wago terminal & other necessary accessories etc. The work shall be done as per approved plan, extant practice on W. C. Railways &the instruction of Rly. engineer at site. SUPPLY PORTION INSPECTION BY CONSIGNEE

1

35903

35903.05

... More
Soldering of tag block, fixing and wiring of G type fuse, bus bar wiring per tag block as per approved plan, extant practice of WCR & as per instruction of site engineer (Solder wire, resin core, etc. material will be supplied by contractor) Unit- Tag block

40

227

9095.6

... More
Circuit wiring/ jumpering as per diagram in the relay rack/IDF rack/tag block. This 49 include preparation of jumper sheet duly checked by firm's site supervisor & wire to wire testing as per wiring diagram.Any wrong jumper done by wire man will be consider & payment for wrong jumper will not be done by the railway. Jumper wire will be supplied by railway & other material like solder wire will be supplied by contractor.Unit- per jumper

2000

14

29660

... More
Design and supply of Detailed Signalling Circuits including panel diagram (if required), SWRD, Control table, Rout section plan , Selection Table, Fuse & Negative Tag Analysis, Contact 51 Analysis , Relay Rack Arrangement and wire count sheet etc. in A3 size, Completion circuit shall be ploted in Autocad. The contractor shall initialy supply 2 Sets of circuits duly signed by the circuit designer having substantial experience on design side for making such circuits , complete for approval of Railways. Railway will return one set of circuit to the contractor duly approved with alterations/ corrections, if any. The contractor shall in corporate Railway's alterations/ corrections in the original tracings & CD without any deviation and submit two copies of the modified circuits. Original tracings modified & final CD complete in all respects along with 4 sets of final approved circuits (out of which one set shall be supplied in transparent polythene bags. Only two sheets of circuits shall be placed in one poly thenebag/cover each) shall be submitted to the Railways in case there are no further alteration suggested by Railways. PER UNIT = PERSTATION

1

106486

106486.36

... More
Preparation & submission of cable route plan of main & tail cables, cable corage plan, location particulars, CT rack particulars, meggering report, earth resistance particulars, traction bonding diagram and any other drawing / particular required in Auto CAD in minimum A3 size Each 52 sheets hould have a block for signature of Railway Officials as well as block for signature of the firm, where signature shall be put up by the authorized signatory of the firm. The name of the work as given by the Railways shall be written on every sheet under the WORK column. One complete set of tracings and four sets of copies of complete above detailed particulars / drawings along with one CD to be supplied by the contractor in thick plastic folder. UNIT- PER station

1

28190

28190.86

... More
Alteration, wiring & testing of Control cum Indication Panel, KLR boxex, group phones, test boards etc. in connection with realy interlocking at existing station. This includes laying and termination of cables if any from panel room to ralay room in GI/HDPE pipe.

1

29337

29337.29

... More
Shifting of Existing apparatus case with foundation by crane or by other means upto 2- 54 20 Mtr decided as per site engineer. (During shifting of location boxes signalling gears disconnection by railway representative). This includes all type of labours charges and filling of locations foundation with river bed sand and plastering on top of the sand.

2

6533

13066.12

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian 55 paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per instructions of Rly engineer at site and extant practice on W.C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases also Termination particulars, equipment names etc. legibly and neatly inside location boxes etc. Main Signal post with signal unit, surface base and complete fittings as per W.C.Rly. Standard practice.

6

791

4748.22

... More
Installation, Wiring & testing from Integrated Power Supply System including Connection to change-over unit. This includes transportation, loading & unloading of IPS system complete and batteries from depot to the site of installation (If required). The all supplies shall be wired right from Auto change over oanel to IPS to power supply distribution board / rack with contractor's own wiring materials. The wiring shall be done with single core multistrand flexible 56 copper wire of 10 Sq mm, 16 Sq mm, 25 sq mm etc. as per IS:694 of 1990 or latest as per RDSO recommendation of IPS installation. This also includes fabrication and fixing of AC/DC power distribution board made on phenolic sheet with connections suitable for 32 A. The 25 sq mm wire shall be used for connecting Batteries from IPS, 16 sq. mm power cable is to be used for wiring of 110V DC, 110V AC & 60V DC (internal) and for balance power supply 10 sq, mm power cable is to be used. All connectors, wiring material, ladders, DWC pipes etc as per site requirement are to be arranged by contractor as per instructions of railway engineer at site. This also includes fixing and wiring of one exhaust fan in the IPS room.

1

30711

30711.82

... More
Fixing of Jn. Route Indication 1-Way/2-Way//3-Way /Multi route indicator on the top of the signal post.

2

715

1431.8

... More
Transportation and Laying of HDPE pipe as per approved cable route plan in the 58 excavated trench, taking due care while transporting and laying the same in the trenches or other protective works. Both the ends of the duct should be sealed with end plugs before laying and should remain sealed till blowing is done.

1

6568

6568.42

... More
Blowing and drawing of OFC through already buried HDPE duct , taking due care while transporting and sealing both the ends after blowing. The cable should be blown according to the technical instructions of the manufacturer and the instructions of the site in-charge.

1

15128

15128.61

... More
Making of straight through joint for under ground cable jelly filled cable/6 Quad cable with joint ing kits supplied against supply item and construction of bricks chamber for protection of joints with all contractor materials.4

4

789

3156.24

... More
Placing and securing of cable route marker in trenches at the specified interval and at diversion joint etc .along the cable route The work shall be done as per extant practice on WCR & the instruction of Rly engineer at site.

20

17

349.8

... More
Splicing of 24 fiber optic fiber cable and making the splice joint with contractor's own 63 splicing machine and tools. Joint should be prepared in such a way that the topof the enclosure shall beat a depth of 1.2 Mtr.and the enclosure should be covered with soft soil than bricks. AcceptanceTest procedure of WCR has to be followed for testing. Continuity of the OFC Armour should not be maintained.

4

5552

22209.72

... More
Supply, Transportation & installation of prefab RCC OFC chamber (specification as per drawing attached No RAILTEL/2002 /PFB/0487 enclosed) & filling with river sand & termite chemical after jointing work is done.

4

9137

36549.44

... More
Installation/modification of Central Evaluator of Axle Counter, wiring from the CT rack 65 to the Central Evaluator, installation and wiring the reset box and wiring the power supply to the Central Evaluator including the supply of shielded cable of required conductor size as applicable with other accessories. Earthing asper manufacturers specification with their own material.

1

16828

16828.91

... More
Supply & installation of maintenance free earth consisting as per RDSO specification No. RDSO/SPN/197/2008 consisting of single earth pit which includes supply of 35 mm2/16 mm2/10 mm2 multistrand single core PVC insulated copper cable as per IS 694 for connecting main earth electrode to MEEB in the equipment room in duplicate as per manufacturers recommendations and as per RDSO specifications as follow: (1) Copper bonded steel electrode of 3.0 meters long, 17 mm diameter with copper bonding thickness of minimum 250 microns and UL listed and marked: 1 No. (2) Earth enhancement compound of RDSO approved brand supplied in sealed bag of minimum 10 KG: 3 Nos. (3) Copper strip of 150mm X 25 mm X 6 mm to terminate earth rod: 1 No. (4) Copper strip of 300mm X 25 mm X 6 mm (MEEB): 1 No. (5) Copper strip of 150mm X 25 mm X 6 mm (MEEB): 1 No. 66 Installation of maintenance free earth includes: Digging/auguring/boring of single earth pit of 100 mm to 125 mmdiameter to the depth of approximately 2.8 meters. Insertion of three meters electrode and penetrating it atleast 0.2 meters by pushing gently with sledge hammer where the neutral soil is assumed. Filling of earth pit with earth enhancement compound (EEC) in slurry form and back filling. Carrying out exothermic weld connection of single earth electrode to a copper tape of 150 mm X 25 mm X 600 mm. Carrying out exothermal weld connection on the copper tape of 150 mm X 25 mm X 6 mm on earth electrode for connecting two 35 mm2 cable for redundancy. The exothermal welding material for bonding the earth system shall be procured from RDSO approved firms which includes graphite moulds, clamps, weld metal powder. 300 mm X 300 mm X 300 mm(inside dimension) concrete earth pit with a concrete lid approximately 50 mm thick with pulling hooks shall be provided to cover the pit. Back side of the cover will be painted in black and date of testing and average earth resistance value shall be written. SUPPLY PORTION INSPECTION BY CONSIGNEE

6

35701

214209

... More
Fixing of GI pipes for crossing the culverts, stone bridges etc. and concreting the ends with brick masonry at both ends as per the instructions of Rly. Engineer at site with Contractor's 67 materials. The brick masonry at the ends shall be done with well-burnt bricks & cement mixture of 1:3 ratios. (Supply of GI pipes is not covered in this item).This includes drilling of 3 nos. of 6 mm holes per meter on the periphery of GI pipe as per instruction of engineer at site. This also includes fixing of GI pipe with contractors own MS Chanel, clamps of proper size etc as per instructions of engineer at site.

90

83

7515

... More
Supply of main LED signal UNIT 110V/AC as per RDSO specification No. RDSO/SPN/199/2010 Rev.1.0 or latest. Suitable for existing CLS housing unit . RED Aspect INSPECTION BY RDSO

5

8009

40046.15

... More
Supply of main LED signal UNIT 110V/AC as per RDSO specification No. RDSO/SPN/199/2010 Rev.1.0 or latest. Suitable for existing CLS housing unit . YELLOW Aspect INSPECTION BY RDSO

5

8508

42541.95

... More
Supply of main LED signal UNIT 110V/AC as per RDSO specification No. RDSO/SPN/199/2010 Rev.1.0 or latest. Suitable for existing CLS housing unit. GREEN Aspect INSPECTION BY RDSO

2

9586

19172.24

... More
Supply Route LED Signal Lighting 110 V Ac in existing CLS housing and compatible with AC LED ECR as per RDSO Spec RDSO/SPN/153/2011 REV 4.1 OR LATEST INSPECTION BY RDSO

15

5728

85934.7

... More
Shunt LED Signal Lighting 110 V Ac in existing CLS housing and compatible with AC LED ECR as per RDSO Spec RDSO/SPN/153/2011 REV 4.1 OR LATEST INSPECTION BY RDSO

9

5614

50529.6

... More
Supply of High frequency Digital Axle Counter Multi Section type complete system including central evaluator(s), final track clearance relay for each track section, Reset boxes, LV 06 boxes, detection points, mushroom housing for track side electronics and all other accessories fully wired to the ultimate capacity and fully equipped to the configuration specified as per RDSO's specification No. RDSO / SPN / 176 / 2013 (ver.3) or latest. Remote diagnostic system to be provided with system. Before supply prior approval of competent authority to be obtained to confirm as per the space available in the relay room. INSPECTION BY RDSO

7

290637

2034465.44



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.