West Central Railway Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
West Central Railway - WCR Tender
Telecommunication Services
Ireps
Opening Date13 Nov 2024
Closing Date9 Dec 2024
Tender Amount₹ 1,07,53,746.55
Costs
EMD
₹ 2,03,800Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
JBP-N-SIG-TENDER-2024-33-JABALPUR DIVISION-S AND T/WEST CENTRAL RLYTender No
JBP-N-SIG-TENDER-2024-33Tender Authority
West Central Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply of hand operated track drill machine with all accessories as detailed attached. INSPECTION BY CONSIGNEE
10
7463
74635
Supply of Integrated cable route tracer, fault locator and RFID marker locator with High Power 12W Transmitter for effective long distance locating, 4 Active Locating Frequencies (577Hz, 8kHz, 33kHz, 200kHZ), depth range up to 9 meter, Passive Power Frequency, Current and 06 resistance measurement in both transmitter and receiver, Super Induction mode, with capability of Electronic Marker locating (both Passive and RFiD) and sheath fault locating in a single equipment , allows software to be downloaded from website, weight less than 2.5 kgs for Transmitter as well as Receiver, Signal Current Measurement in cable. RDSO Recommended (Model - 2273M-ID). Make 3M Model 2273 M-iD or equivalent INSPECTION BY RITES
2
458724
917449.72
Supply of digital multi meter digital type, three & three forth digit (3&3/4 digit) Make Stanlay SMM 606, Fluke 179/Metrasafe 20/Km 891 or Equivalent. INSPECTION BY CONSIGNEE
10
46203
462038.4
Supply of Analog-Digital insulation and continuity tester as per technical specifications attached at Annexure A. Make and model Rishabh Insu 20/Stan One SIT 500 or equivalent INSPECTION BY CONSIGNEE
40
8761
350460
Supply of INDICATIVE TYPE OF FUSE INSERTS. With holder 10 A. INSPECTION BY CONSIGNEE
1000
26
26210
Supply of earth electrode assembly as per Drg. Nos. CR/SK-753. INSPECTION BY CONSIGNEE
25
1550
38762.75
Supply of SPT phone for IBS. (which shall be installed on IBS post)along with one no.of slave unit being installed in SM'S office (both master and slave unit mustwork on 24V DC and must 12 be suitable for 25KVAC RE area).as per instructions of site incharge , ACES make or similar . Note : The contractor shall ensure that there is no interface in communication between the master and slave units owing to power hump due to RE induction.Cable from IB signal unit to the cable termination board in SM's room/relay room will be provided by the Railways. It shall work on OFC or quad cable & it shallensured by contractor before supply of the item. INSPECTION BY CONSIGNEE
11
15057
165634.48
Supply of Apparatus cases with miniature E Type Locks with keys. (E Type Locks & keys as per spec. No IRS: S-30/64 & RDSO Drg. No. SA 3376/M & SA 3377/M with latest amendments). Single case as per Drg No. WS - 8842/A with latest alteration. INSPECTION BY CONSIGNEE
3
24955
74865.36
Supply of Apparatus cases with miniature E Type Locks with keys. (E Type Locks & keys as per spec. No IRS: S-30/64 & RDSO Drg. No. SA 3376/M & SA 3377/M with latest amendments). Half Case as per Drg No WS-8842/A with latest alteration. INSPECTION BY CONSIGNEE
3
16858
50574.24
Supply of Standard Tools set. Kit will includes all tools measuring instruments as per Technical specification attached at Annexure 'B' . INSPECTION BY RITES
10
54486
544860.8
Component for Clamp type Ground connection for IRS point machines 220mm stroke as per annexure attached at Annexure D. INSPECTION BY RITES
40
37170
1486800
Supply & installation of Polymeric position temperature coefficient PPTC device (Self resisting type 1.5A/72V DC with soldering of 16/0.02 copper wire lead as prescribed length) and crimping & soldering of cu pin type. SUPPLY PORTION INSPECTION BY CONSIGNEE
1000
23
23780
Installation & fixing of earth electrode assembly including earth wire connected 02 through GI wire 8 SWG supported on M.S. flat of size 6mm x 40mm to earth electrode for signaling Equipment. Contractor will bring Earth enclosure and all other material required for provision of earthing.
25
3716
92922.25
Fixing of ARA /WAGO Terminals and fuse blocks with provision of holes on hylem sheets and fixing by galvanized nuts & bolts. This includes provision of two additional holes on the hylam board on either side for cable conductor entry. The work shall be done as per Engg. at site.
400
24
9616
Termination of cable cores on ARA/ disconnecting type terminal, fuse blocks, 8 way 04 terminals block in the apparatus cases/point machine. This includes all associated works of pulling out the cable from underground, dressing of cable, making wiring tree etc. This includes soldering of armour tree/ring of cables and connecting to copper plate through GI wire bus bar in location boxes. The work shall be done as per location plans and instructions of Rly engineer at site.
800
14408
14408
Excavation of trench as per cable route plan, 1.2 mtr deep, 300mm wide at the bottom along main line in normal soil, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by shahabad stone/bricks, clearing of route, bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.
-
-
5
Excavation of trench as per cable route plan, 1 mtr deep, 300mm wide at the bottom along main line in hard soil / murrum, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by bricks.
0.1
-
13245.2
Excavation of cable trench 1m deep and 300mm wide across the track, for track crossing and refilling after laying of DWC/RCC/GI pipes. The work shall be done as per extant practice on W.C. Rly & instruction of Rly engineer at site.
120
211
25431.6
Cutting of all types of Roads preparatory to trenching & excavation to depth of 1 Mtr X 300 mm wide approximately and refilling, after laying of RCC/GI/DWC pipe and to restore the road to original condition. The work shall be done as per extant practice
48
351
16848
Preparation of Cable way 150 mm wide at the bottom and 300 mm deep in rocky area & refilling the same (after cable-laying) with concrete mixture of proportion 1:3:6 and grouting the ends at either side of the rocky portion using concrete mixture with Contractors own material.
300
913
274170
Supply & laying of well burnt bricks of size 225x100x75mm inside the trench (with the brick length being perpendicular to cable route) after laying of cable in station area from Outermost to Outermost signal or at any other location as per instruction of Engineer at site.
18000
6
118620
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches. as per 11 approved cable route plan in the excavated trench, inside GI, DWC Pipes etc. taking due care while transporting and sealing both the ends after laying. The cables are to be laid as per extent practice of WCR and as per the instructions of engineer at site. This includes transportation of cable from the consignee depot to site or as per instruction of engineer incharge.
8
10106
80849.68
Transportation & Laying of GI/DWC/RCC pipes along with collars in trenches at places wherever required as per the instruction of the engineer at site.
120
83
10023.6
"Transporting, Supply and installation of cable route indicator/marker at interval of 50 13 mtrs. in trenches along the cable route as per drawing SDO/Cable laying/020 or latest issued by railway. The work shall be done as per extant practice on WCR & the instruction of Rly engineer at site." SUPPLY PORTION INSPECTION BY CONSIGNEE
40
1236
49452
Excavation, casting and plastering (above ground level) of Apparatus case foundation with contractors own Metal Sheet frame, cement, anchor bolts and other materials. Single case as per Drg No JBP/S&T/C/084
5
14331
71658.4
Erection of apparatus cases. This includes filling of location foundation with river bed sand and plastering on top of the sand. Single case
5
1637
8188.4
Fabrication and fixing of phenolic board in location box by providing all fixtures as per 16 Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. Lasing and dressing of cables/wires terminated with contractors own supply of lasing thread. The work shall be done as per instructions of Rly engineer at site. Single case
5
2315
11575.8
Installation of Eqpt. (Relays, resistance, chargers & batteries etc.) & wiring of the same in apparatus cases as per location & circuit diagrams with contractor's own PVC wires and wiring material. The work shall be done as per instruction of Rly engineer at site and approval of wiring material ( from RDSO approved firms) being used and extant practice in W.C. Rly). Wiring of relays should be with 16/0.2mm wire and all other equipments wiring by 2.5 sq mm multi strand wire of IS 394 of 1990 or latest. Single caseInstallation of Eqpt. (Relays, resistance, chargers & batteries etc.) & wiring of the same in apparatus cases as per location & circuit diagrams with contractor's own PVC wires and wiring material. The work shall be done as per instruction of Rly engineer at site and approval of wiring material ( from RDSO approved firms) being used and extant practice in W.C. Rly). Wiring of relays should be with 16/0.2mm wire and all other equipments wiring by 2.5 sq mm multi strand wire of IS 394 of 1990 or latest. Single case
-
-
17
Painting two coats of enamel paint over one coat of Red Oxide primer on the following 18 items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per WCR practice. Appratus case full size
5
663
3315.9
Lettering numbering termination particulars, equipments names etc legibly and neatly inside location boxes. Single case.
5
402
2012.3
Excavation, casting and plastering (above ground level) of Apparatus case foundation with contractors own Metal Sheet frame, cement, anchor bolts and other materials. Half case as per Drg No JBP/S&T/C/085
5
11772
58863.1
Erection of apparatus cases.This includes filling of location foundation with river bed sand and plastering on top of the sand. Half Case.
5
1059
5299.5
Fabrication and fixing of phenolic board in location box by providing all fixtures as per 22 Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. Lasing and dressing of cables/wires terminated with contractors own supply of lasing thread. The work shall be done as per instructions of Rly engineer at site. Half Case.
5
1764
8824.9
Installation of Eqpt. (Relays, resistance, chargers & batteries etc.) & wiring of the same in apparatus cases as per location & circuit diagrams with contractor's own PVC wires and wiring 23 material. The work shall be done as per instruction of Rly engineer at site and approval of wiring material ( from RDSO approved firms) being used and extant practice in W.C. Rly). Wiring of relays should be with 16/0.2mm wire and all other equipments wiring by 2.5 sq mm multi strand wire of IS 394 of 1990 or latest. Half case
5
1286
6434.4
Painting two coats of enamel paint over one coat of Red Oxide primer on the following 24 items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per WCR practice. Apparatus case Half size
5
419
2098.45
Lettering numbering termination particulars, equipments names etc legibly and neatly inside location boxes. Half case
5
192
963.65
Re-alignment/shifting of existing apparatus case with foundation by crane or by other 26 means decide as per site enginer. This includes excavation surrounding apparatus case/location boxes and all type of labour charges & minor/major repariring work, plastering white wash & filling of foundation with river bed sand.
20
7155
143116
"Supply and installation & Programming mapping of RFiD Electronic Marker with capability of saving the user specific data inside the marker memory chip, ( Data storage up to 256 27 bits) later readable by locator during locating floating coil to keep detection circuit always horizontal for better detection ) . This can be buried up to depth of 5 Ft. for Signaling & Telecom cables. This includes GPS mapping of the cable route as per the marker installed. Make- Stanlay/3M or equivalent. SUPPLY PORTION INSPECTION BY RITES".
60
3020
181218.6
All work pertaining to Horizontal Directional Drilling (HDD)/Boring and trenchless cabling in hard/rocky soil by machine. It includes supply. transportation and insertion of self lubricated HDPE Pipe and laying of cables in boring under the track road platform circulating area by using self lubricated HDPE Pipe of 120mm outer dia and 103.5mm inner dia in the bore. The depth of horizontal boring should he minimum 2 mtr upto 3 mtr, from rail flange road level ground level as per site requirement and as per instructions of Railway Engineer incharge. Thickness 3.5 to 4.1 mm as per specification no. IS 4984:1995 with latest amendment, Material Grade PE 63
-
-
28
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%