West Central Railway Tender

... More
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

West Central Railway - WCR Tender

Works
Civil And Construction
Bridge Construction
Ireps
Opening Date28 Jan 2025
Closing Soon28 Feb 2025
Tender Amount₹ 46,24,136.21 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Splicing of 24 fiber optic fiber cable and making the splice joint with contractor's own 04 splicing machine and tools. Joint should be prepared in such a way that the top of the enclosure shall be at a depth of 1.2 Mtr. and the enclosure should be covered with soft soil than bricks. Acceptance Test procedure of WCR has to be followed for testing. Continuity of the OFC Armour should not be maintained.

10

4935

49355.6

... More
Making of straight through joint for underground cable jelly filled cable/6 Quad cable with joint ing kits supplied against supply item and construction of bricks chamber for protection of joints with all contractor materials.

-

-

5

... More
Supply, Transportation & installation of prefab RCC OFC chamber (specification as per drawing enclosed) & filling with river sand & termite chemical after jointing work is done. Supply item Inspection by Consignee.

10

6158

61582.8

... More
Transportation and Laying of HDPE pipe as per approved cable route plan in the 07 excavated trench, taking due care while transporting and laying the same in the trenches or other protective works. Both the ends of the duct should be sealed with end plugs before laying and should remain sealed till blowing is done.

5

5838

29193.35

... More
Blowing and drawing of OFC through already buried HDPE duct, taking due care while transporting and sealing both the ends after blowing. The cable should be blown according to the technical instructions of the manufacturer and the instructions of the site in-charge.

5.5

13447

73963.01

... More
Supply of GI pipes with collars (screwed and socket) as per spec. No. IS 1239 part-1 (2004 or latest), medium class, nominal bore of 100 mm, nominal mass of tube 12.5Kg ± 10% per meter and complying parameters of specification. Inspection by Consignee.

840

942

791616

... More
Fixing of GI pipes for crossing the culverts, stone bridges etc. and concreting the ends with brick masonry at both ends as per the instructions of Rly. Engineer at site with Contractor's 10 materials. The brick masonry at the ends shall be done with well-burnt bricks & cement mixture of 1:3 ratios. (Supply of GI pipes is not covered in this item).This includes drilling of 3 nos. of 6 mm holes per meter on the periphery of GI pipe as per instruction of engineer at site. This also includes fixing of GI pipe with contractors own MS Chanel, clamps of proper size etc as per instructions of engineer at site.

840

83

70140

... More
Excavation of trench as per cable route plan, 1.2 mtr deep, 300mm wide at the bottom along main line in normal soil, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by shahabad stone/bricks, clearing 11 of route, bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.

4

81257

325029.2

... More
Excavation of trench as per cable route plan, 1 mtr deep, 300mm wide at the bottom along main line in hard soil / murrum, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by bricks.

1

116079

116079.6

... More
Excavation of cable trench 1m deep and 300mm wide across the track, for track crossing and refilling after laying of pipes. The work shall be done as per extant practice on W.C. Rly & instruction of Rly engineer at site.

50

197

9863.5

... More
Preparation of Cable way 150 mm wide at the bottom and 300 mm deep in rocky area 14 & refilling the same (after cable-laying) with concrete mixture of proportion 1:3:6 and grouting the ends at either side of the rocky portion using concrete mixture with Contractor's own cement & other materials.

50

850

42533.5

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches. as per 15 approved cable route plan in the excavated trench, inside GI, DWC Pipes etc. taking due care while transporting and sealing both the ends after laying. The cables are to be laid as per extent practice of WCR and as per the instructions of engineer at site. This includes transportation of cable from the consignee depot to site or as per instruction of engineer incharge.

3

9406

28220.94

... More
Supply & laying of well burnt bricks of size 225x100x75mm inside the trench (with the brick length being perpendicular to cable route) after laying of cable in station area from Outermost 16 to Outermost signal or at any other location as per instruction of Site Engineer. Note: - Size of bricks to be got approved by Site Engineer. In case brick size is in variance with the size given in the tender schedule then proportionate payment on volumetric basis shall be paid to contractor subject to a maximum limit of schedule rate. Supply item inspection by Consignee.

18000

5

104040

... More
Supply, transporting & installation of cable route marker at interval of 50 mtr in trenches along the cable route as per extant practice on WCR & the instruction of Rly engineer at site. Supply item inspection by Consignee.

120

1150

138091.2

... More
Supply of Clamp meter as per specification attached. Inspection by Consignee.

2

3318

6637.8

... More
Supply of Analog push button telephone phone with CLI facility. Make- Beetle/BPL/Alkatel/Mavel or similar. Inspection by Consignee. 03

20

772

15449

... More
Supply of Telephone Jack RJ11 Type (Rosette). Inspection by Consignee.

500

24

12000

... More
Supply of ATS switch 16 Amp of reputed make (19" Rack Mountable). Inspection by Consignee. 05

1

40592

40592

... More
Supply of line cord.(RJ-11) type. Inspection by Consignee. 06

50

43

2163

... More
Supply of HMT cord. Inspection by Consignee.

50

62

3104

... More
Supply of UTP indoor cable CAT 6 , to support10/100/1000 Mbps .The category 6 cable should consists of 4 pair of solid insulated copper 23 AWG(0.57mm) pairs separated with a centralslit film, insulation -polyethylene Make D-link, Molex, Dax, or equivalent. Inspection by Consignee. 08

3050

19

58743

... More
Supply of wireless wi-fi router. Make TP-Link or equivalent. Inspection by Consignee. 09

15

3960

59400

... More
Supply of Optical Power meter as per specification attached. Inspection by Consignee.

5

8000

40000

... More
Supply, VDSL2 profile 17a over POTS gateway, 4FE LAN ports, Wi-Fi N300. Inspection by Consignee. 11

15

5192

77880

... More
Supply of RJ 45 connector of reputed make. Inspection by Consignee. 12

1000

13

13680

... More
Supply of Digital multimeter as per specification attached.Inspection by Consignee.

10

2071

20719.8

... More
Supply & fixing of concealed modular composite box of 04 port 110-style front, inner surface plate, duly fitted with 01 nos. RJ-11 telephone jack & 02 nos. RJ45 jack. Supply item Inspection by Consignee.

10

297

2972.4

... More
Supply and installation of Online, Pure sine wave UPS of 1 KVA with SMF batteries minimum 1600 VAH for back-up of 1 Hrs. (APC/Numeric/Tata libert make or equivalent) As per Specification Attached. Inspection by Consignee.

2

20232

40464.84

... More
Supply & installation of Rack Mounted Fibre Management System 19'' for 24 fibre (fully loaded) FMS with SC type adapters. Supply item Inspection by Consignee.

6

18371

110229

... More
Supply & installation of 6U, 19" covered Rack with (1) front side transparent door with 16 lock arrangement (2) cable organizers (3) provision of one no. of power supply( each consists of 6 nos. x 15A/15Amulti pin sockets with ON/OFF switch and fuse arrangement)strip. Make - HCL or Rittel or APW or President or equivalent. Supply item Inspection by Consignee.

2

2327

4655.58

... More
Supply and Installation of Quartz clock IS-12510 Q4 Category, metal dial and hands wall clock, Make/Model: Ajanta wall clock M.No.7607 or similar. Supply item Inspection by Consignee.

6

822

4934.52

... More
Supply & Installation of Manageable non-POE 24 port switch with minimum 02 SFP ports. Make- CISCO/HPE /Juniper or equivalent. Supply item Inspection by Consignee.

2

14160

28320.36

... More
Supply and fixing of Power Supply board with 5-amp socket and switch. Make : Anchor/ Leader/ Havells or similar. (Inspection Authority: Consignee)

6

80

483.72

... More
Supply and fixing of different size PVC casing and capping/Pipe in Grey or Stream colour confirming to IS standard as required by Railways at size 25x16/25x25/32x16mm or as required at site. By fixing/clamping at a regular interval to the wall for indoor wiring Make Sudhaker/Modi/AKG or better. Supply item Inspection by Consignee.

150

31

4660.5

... More
Excavation of trench as per cable route plan, 1.2 mtr deep, 300mm wide at the bottom along main line in normal soil, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by shahabad stone/bricks, clearing 21 of route, bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.

0.5

-

40628.65

... More
Transportation and Laying of HDPE pipe as per approved cable route plan in the 22 excavated trench, taking due care while transporting and laying the same in the trenches or other protective works. Both the ends of the duct should be sealed with end plugs before laying and should remain sealed till blowing is done.

0.5

-

2919.34

... More
Blowing and drawing of OFC through already buried HDPE duct , taking due care while 23 transporting and sealing both the ends after blowing. The cable should be blown according to the technical instructions of the manufacturer and the instructions of the site in-charge manufacturer and the instructions of the site in-charge.

0.5

-

6723.91

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches. as per 24 approved cable route plan in the excavated trench, inside GI, DWC Pipes etc. taking due care while transporting and sealing both the ends after laying. The cables are to be laid as per extent practice of WCR and as per the instructions of engineer at site. This includes transportation of cable from the consignee depot to site or as per instruction of engineer incharge.

0.5

-

4703.49

... More
Supply , fixing & cable termination of 20 pair Krone make Krones tools. Supply item Inspection by Consignee.

4

3673

14693.8

... More
Supply of permanently lubricated HDPE Telecom Duct, 40/33 mm, as per TEC/GR/FA/CDS-008/04/AUG-19 or latest, along with accessories. Inspection by Consignee.

5

53849

269246.45

... More
Supply of straight joint enclosure (SJC) complete with all accessories as per TEC Specification TEC/GR/TX/OJC-002/03/APR/2010 or latest of reputed make like Raychem, Birla VXL, 3M, shakti or similar. Inspection by Consignee.

4

3653

14615.72

... More
Supply of GI pipe as per Specn. No. IS 1239 (Part-1)/1990 medium class normal bore of 100 mm, nominal mass of Tube 12.5 Kg (+/-) 10% per meter and complying parameters of specification. (Inspection by Consignee)

18

942

16963.2

... More
Supply of Gigabit, single mode, auto sensed, Media converter fiber to Ethernet Make- Mrotek/Teamlink /Syrotek/Flrotek or similar. Inspection by Consignee.

8

3126

25011.2

... More
Supply of OFC patch cord Type LC-SC or SC-SC (as per site requirement) Length 10 Mtrs of reputed make. Inspection by Consignee.

10

319

3191.2

... More
Supply of Rack Mounted Fibre Management System (Fully loaded) 19'' rack mountable for 24 fibre FMS of SC adapters of reputed make. Inspection by Consignee.

3

13678

41034

... More
Supply of 12U Rack Enclosures Networking/Server Rack with all accessories. Make- Comrack, RitteI,APW, HCL, D-LINK. Inspection by Consignee.

1

4767

4767.76

... More
Excavation of trench as per cable route plan, 1.2 mtr deep, 300mm wide at the 08 bottom along main line in normal soil, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by shahabad stone/bricks, clearing of route, bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.

5

81257

406286.5

... More
Excavation of trench as per cable route plan, 1 mtr deep, 300mm wide at the bottom along main line in hard soil / murum, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by Shahabad stone/bricks, clearing 09 of route, bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.

1

116079

116079.6

... More
Cutting of all types of Roads preparatory to trenching & excavation to depth of 1 Mtr X 10 300 mm wide approximately and refilling, after laying of GI pipe and to restore the road to original condition. The work shall be done as per extant practice on W.C.Rly & instruction of Rly engineer at site.

20

250

5007.2

... More
Supply & laying of well burnt bricks of size 225x100x75mm inside the trench (with the brick length being perpendicular to cable route) after laying of cable in station area from Outermost 11 to Outermost signal or at any other location as per instruction of Site Engineer. Note: - Size of bricks to be got approved by Site Engineer. In case brick size is in variance with the size given in the tender schedule then proportionate payment on volumetric basis shall be paid to contractor subject to a maximum limit of schedule rate. Supply item Inspection by Consignee.

8000

5

46240

... More
Transportation & Laying of GI/DWC/RCC pipes along with collars in trenches at places wherever required as per the instruction of the engineer at site.

18

73

1317.6

... More
Supply of Concrete Cable Marker (specification as per drawing enclosed). Placing and 13 securing of cable route marker in trenches at the specified interval and at diversion joint etc .along the cable route. The work shall be done as per extant practice on WCR & the instruction of Rly engineer at site. INSPECTED BY CONSIGNEE

100

270

27083

... More
Cement ,concrete work in the ratio of 1:3:6 with contactor's own material as per instruction of site engineer.

2

4113

8227.64

... More
Horizontal boring by machine under railway track/road for laying of HDPE pipe at the 15 depth of minimum 2.1 meter from formation level (Level of earth below ballast) & laying of various cables/duct as directed by engineer-in- charge by trenchless technology. Note: This does not include the supply of HDPE pipe.

100

809

80910

... More
Splicing/Dropping/Termination of each Fiber/Pigtail in the LIU/FDMS/ Termination Joints through fusion Splicing of the termination of OFC Cables.

72

27

1974.96

... More
Splicing of 24 fiber optic fiber cable and making the splice joint with contractor's own 17 splicing machine and tools. Joint should be prepared in such a way that the top of the enclosure shall be at a depth of 1.2 Mtr. and the enclosure should be covered with soft soil than bricks. Acceptance Test procedure of WCR has to be followed for testing. Continuity of the OFC Armour should not be maintained.

3

4935

14806.68

... More
Supply, Transportation & installation of prefab RCC OFC chamber (specification as per drawing enclosed) & filling with river sand & termite chemical after jointing work is done. Supply item Inspection by Consignee.

3

6158

18474.84

... More
Transportation and Laying of HDPE pipe as per approved cable route plan in the 19 excavated trench, taking due care while transporting and laying the same in the trenches or other protective works. Both the ends of the duct should be sealed with end plugs before laying and should remain sealed till blowing is done.

5

5838

29193.35

... More
Blowing and drawing of OFC through already buried HDPE duct, taking due care while transporting and sealing both the ends after blowing. The cable should be blown according to the technical instructions of the manufacturer and the instructions of the site in-charge.

-

-

20

... More
Supply of straight joint enclosure(SJC) complete with all accessories as per TEC Specification TEC/GR/TX/OJC-002/03/APR/2010 or latest of reputed make like Raychem, BirlaVXL, 3M or similar. Inspection by Consignee.

4

3653

14615.72

... More
Splicing of 24 fiber optic fiber cable and making the splice joint with contractor's own 02 splicing machine and tools. Joint should be prepared in such a way that the top of the enclosure shall be at a depth of 1.2 Mtr. and the enclosure should be covered with soft soil than bricks. Acceptance Test procedure of WCR has to be followed for testing. Continuity of the OFC Armour should not be maintained.

4

4935

19742.24

... More
Supply of Thermo-Shrinkable jointing kit as per RDSO Specification No.IRS/TC/77/2006(Rev.-1) with amnd.No.1or latest amendments for straight through joint & derivation joint suitable for 6 quad/PIJF. Inspection by Consignee.

4

2239

8956.8

... More
Supply of PIJF CABLE JOINTING KIT as per RDSO Spec. No.RDSO/SPN/TC/57/2015 Rev.1Amdt-1 or latest (TSF-3). Inspection by Consignee.

4

2006

8025.12

... More
Supply & installation of portable Management Console. Detailed technical specification attached. Inspection by consignee

4

76153

304612

... More
Supply of UTP CAT-6 cable, consisting of 1 Nos Box=305m roll. Make-Dlink / Digisol /Systimax or equivalent. Inspection by Consignee

10

5001

50017.1

... More
Supply of Analog push button telephone phone with CLI facility. Make- Beetle/BPL/Alkatel/Mavel or similar. Inspection by Consignee.

100

772

77245

... More
Supply of UPS capacity of 1 KVA having MOSFET-PWM technology rated output of single phase 230 VAC,50 Hz inbuilt battery with 30minutes backup. Make-Scientech, Luminious, Sukam, APC, Uniline, Mrotec. or equivalent. Inspection by Consignee.

4

6294

25179.4

... More
Cutting of all types of Roads preparatory to trenching & excavation to depth of 1 Mtr 09 X300 mm wide approximately and refilling, this also includes transportation and laying of RCC/GI/DWC pipe and to restore the road to original condition. The work shall be done as per extant practice on W.C.Rly & instruction of Rly engineer at site.

20

250

5007.2

... More
Installation of Thermo- shrinkable joining kits for making (a) straight through joints without transformers for 6 quad Jelly filled cable (b) Derivation joint without transformer for 6 quad 10 jelly filled cable, and (c) Straight Through joint without transformer for 10Pr/20Pr.PIJF cables after jointing the cable through test such as insulation test, Continuity cable losses etc. to be carried out jointly with the Railway Engineer. If any defect or any damage observed during jointing, the contractor should redo the joint free of cost.

4

1608

6434.48

... More
Excavation of trench as per cable route plan, 1.2 mtr deep, 300mm wide at the bottom along main line in normal soil, This work includes covering of cable laid in trenches by loose 11 soil for a layer of 50 mm thickness approx before covering by stone/bricks, clearing of route, bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.

1

81257

81257.3

... More
Excavation of trench as per cable route plan, 1 mtr deep, 300mm wide at the bottom along main line in hard soil / murrum, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by bricks.

0.2

-

23215.92

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in excavated trenches. 13 as per approved cable route plan, inside GI, DWC Pipes etc. taking due care while transporting and sealing both the ends after laying. The cables are to be laid as per extent practice of WCR and as per the instructions of engineer at site. This includes transportation of cable from the consignee depot to site or as per instruction of engineer incharge.

1.5

9406

14110.47

... More
Supply and fixing of different size PVC casing and capping/Pipe in Grey, Stream or 14 Cream colour slotted channel through confirming to IS standard as required by Railways at various size of 25x16mm, 32x16mm, 25x25mm or as required at site. By fixing/clamping at a regular interval to the wall for indoor/outdoor wiring. Make: Sudhaker/Modi/G or equivalent. Supply item inspection by consignee.

200

31

6214



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.