West Central Railway Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

West Central Railway - WCR Tender

Works
Electrical Goods and Equipments
Machinery and Tools
Electrical and Electronics
Ireps
Opening Date7 Dec 2024
Closing Date13 Jan 2025
Tender Amount₹ 2,69,06,154.49 
Notes
Download

Costs

Summary

S&t Work In Connection With Construction Of Rob At Lc Nos. 27, 32, 65, 67 & 310a (kte-bina Section) Of Jabalpur Division On West Central Railway (signalling Work)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of end stop suitable for disconnect terminal block INSPECTION BY CONSIGNEE

1200

16

20088

... More
Supply of Earth Electrode assembly as per Drawing no. S&T/CON/KOTA/Earthing/01 WCR Drawing. INSPECTION BY CONSIGNEE

22

1637

36029.18

... More
Supply of Apparatus cases with miniature E Type Locks with keys. (E Type Locks & 06 keys as per spec. No IRS: S-30/64 & RDSO Drg. No. Drawing no. WCR/Dy CSTE(CON)/KOTA/3 with latest amendments). Single case as per Drg No. WS - 8842/A with latest alteration. INSPECTION BY CONSIGNEE

12

24955

299461.44

... More
Supply of cartridge fuse block made of PBT as per RDSO Drg. Nos. SA - 23748 Alt. 4 and Spec.Nos. IRS-S-75/2006 with INSPECTION BY RDSO

700

243

170583

... More
Supply of Non-deteriorating type low voltage cartridge fuse rate current 2 Amp / 4 Amp in equal proportion round head type as per specification Nos. IRS/S/78/92 with latest amendment. INSPECTION BY RDSO

700

105

73850

... More
Supply of PVC indoor cable 1x24x1 mm dia having colour coding of insulation of inner core shall be six colours viz. Blue, Red, Grey, Green, Brown & Black and shall be confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY RDSO

2

254095

508190.96

... More
Supply of PVC insulated railway signalling indoor single core [ tinned jumper wire] 1X 0 . 6 mm dia as per RDSO spec. Nos. IRS:S-76/89 with latest amendments of various colours INSPECTION BY CONSIGNEE

2

2907

5814.26

... More
Supply of PVC insulated flexible wire 16/ 0.2 mm dia as per RDSO spec. Nos. IRS:S- 76/89 with latest amendments of various colours INSPECTION BY CONSIGNEE

6

8159

48958.62

... More
Supply of Jumper wire 1X1mm dia as per RDSO spec, IRS:S-76/89 with latest amendments of various colours INSPECTION BY CONSIGNEE

10

8807

88076.3

... More
Supply of flexible cable single core multistrand copper conductors, 1x6 sq.mm confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY CONSIGNEE

2

77238

154477.42

... More
Supply of flexible cable single core multistrand copper conductors, 1x2.5 sq.mm confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY CONSIGNEE

2

20651

41302.46

... More
Supply of Handheld Digital Earth Clamp Tester for clamp on earth/ground resistance 15 measurement up to 1000 ohms. Accuracy 0.1 - 0.99 : 1%, 1 -49 : 1.5% Also measure current leakage up to 20A. No spines required for measurement. Model - CET 500, MECO DCET-2 or equivalent / higher version make: Stanlay. INSPECTION BY RITES

14

89012

1246172.62

... More
Supply of Phenolic Laminated sheet, resin bonded 10mm thick, grade P3 in standard size of 1.22 x 1.22 Mtr as per spec. No IS 2036 of 1974 . INSPECTION BY CONSIGNEE

24

4993

119843.76

... More
Supply of Cable route locator/tracer set suitable for Detecting underground armoured 17 optic fiber cable (OFC] and signaling cables with LCD Graphic. Display active/passive modes and depth range upto 10 mtr. Make- C-scope, model- DXL-4 and SGA-4, RD-8200 or equivalent. INSPECTION by RITES"

3

417182

1251547.2

... More
Supply of basic material to construct Unit Maintenance Free Earth consisting as per RDSO Spec No. RDSO/ SPN/ 197/2008 (or with latest Amend) consisting of : a) Copper bonded steel 18 electrodes of 3.0 m long, 17.2 mm dia with copper bonding thickness of min 250 micron and UL listed and marked - 1 No. b) Earth Enhancement compound of approved brand supplied in sealed bags of min 10 Kgs - 3 Nos. c) Copper Strip of 150 x 25 x 6mm to terminate Earth Rod - 2 No. d) Copper Strip of 300 x 25 x 6mm (MEEB) - 1 No. Procurement should be done by RDSO approved source. INSPECTION BY CONSIGNEE

6

18729

112379.28

... More
Supply of Electrically operated lifting barrier assembly as per RDSO Spec RDSO/SPN/208/2012 Ver 2.0 with Amendment-1 or latest. Each consisting of 2 No s. electrically operated lifting barriers, 2 Pedestals, 2 Nos. of 8 band circuit controller with limit switch, hand cranks, 2 electric motors 110 VAC 0.5 HP without centrifugal switch, 2 GI Octagonal Booms as per RDSO Drawing RDSO/S-11600 in 4 section of 8 feet long each, with 2 stop boards, boom light boxes, MS. 19 counter weights & 2 Nos. of boom support for resting boom & boom resting assembly along with Gate Control Panel, indication panel on sheet metal fabricated box with switches and buttons to operate the gate as per Spec except ( a) motor current i s max. 5 Amps. for 0.5 HP motor & motor confirms as per spec (b) WAGO terminals to be used instead of Elmex or M-5 terminals. (c) Circuit Controller should have CAM operated Siemens Or Similar limit switches instead of wiping type contacts. Crank handle arrangement will be as per Rly. requirement. The movement of the boom over 85 degrees to be restricted mechanically. INSPECTION BY RDSO

4

408384

1633539.04

... More
Supply of Cable Fault locator as per specification attached. Make: Tempo Model Sidekick Set(1155-5001) or equivalent INSPECTION BY RITES

1

656458

656458.07

... More
Modification, Alteration, Augmentation, Design, Manufacture, Supply, Installation, Testing & Commissioning in Existing Hot Stand by Electronic Interlocking (EI) System of with Electronic Interlocking (EI) as per RDSO specification No. RDSO/SPN/203/11 or RDSO/SPN/192/2019 Ver 2.0 with latest amendment, as per Technical Requirement & Approved Signalling Plans & Diagrams. All Interfacing Relays & other material suitable for alteration to be supplied by contractor. This item includes supply of necessary documents in the form of Tracings and 6 sets of Paper Print. This also includes 12 months warranty period of all supplied equipment. Special condition in the tender schedule for the item no. 01 Schedule B - "The Successful bidder shall submit an undertaking with existing EI's OEM or OEM authorised /supported agency after LOA is issued (but before supply of material) for installation, testing and commissioning (including after sales support during the warranty period) to comply extant RDSO guidelines and to meet contract specific requirements." LC 27 and LC 32 - M/S Hitachi LC 65 and LC 67 - M/S Kyosan

-

-

1

... More
Fixing of ARA /WAGO Terminals and fuse blocks with provision of holes on hylem sheets and fixing by galvanised nuts & bolts. This includes provision of two additional holes on the hylam board on either side for cable conductor entry. The work shall be done as per Engg. at site.

2000

21

43820

... More
Termination of cable cores on ARA/ disconnecting type terminal, fuse blocks, 8 way 03 terminals block in the apparatus cases/point machine. This includes all associated works of pulling out the cable from underground, dressing of cable, making wiring tree etc. This includes soldering of armour tree/ring of cables and connecting to copper plate through GI wire bus bar in location boxes. The work shall be done as per location plans and instructions of Rly engineer at site.

2000

32840

32840

... More
Soldering of tag block, fixing and wiring of G type fuse, bus bar wiring per tag block as per approved plan, extant practice of WCR & as per instruction of site engineer (Solder wire, resin core, etc. material will be supplied by contractor) Unit- Tag block

14

227

3183.46

... More
Detailed testing of wiring including continuity testing, functional testing, selection table and locking table testing with simulation panel including making panel through in the presence of Rly officials. The item includes wiring of simulation panels as per standard practice. Erection and wiring of simulation panels shall be with contractors own materials. Signal lamps required for simulation panel will be supplied by contractor. The contractor shall hand over the system for railways testing and shall arrange technical man power, wireman and supervisor to facilitate this testing by railway. UNIT- PER station/IBS

-

-

8

... More
Design and supply of Detailed Signalling Circuits including panel diagram (if required), SWRD, Control table, Route section plan , Selection Table, Fuse & Negative Tag Analysis, Contact Analysis , Relay Rack Arrangement and wire count sheet etc. in A3 size, Completion circuit shall be ploted in Autocad. The contractor shall initially supply 2 Sets of circuits duly signed by the circuit designer having substantial experience on design side for making such circuits , complete for 09 approval of Railways. Railway will return one set of circuit to the contractor duly approved with alterations/ corrections, if any. The contractor shall incorporated Railway's alterations/corrections in the original tracings & CD without any deviation and submit two copies of the modified circuits. Original tracings so modified & final CD complete in all respects alongwith 4 sets of final approved circuits (out of which one set shall be supplied in transparent polythene bags. Only two sheets of cicuits shall be placed in one polythene bag/cover each) shall be submitted to the Railways in case there are no further alteration suggested by Railways.

2

100064

200128.98

... More
All work pertaining to Horizontal Dirctional Drilling (HDD)/Boring and trenchless cabling in normal soil by machine . It includes supply. transportation and insertion of self lubricated HDPE Pipe 10 and laying of cables in boring under the track road plateform circulating area using By using self lubricated HDPE Pipe of 120mm outer dia and 103.5mm inner dia in the bore . The depth of horizontal boring should be minimum 3 mtr, from rail flange road level lground level as per site requirement and as per instructions of Railway Engineer incharge. Thickness 3.5 to 4.1 mm as per specification no. IS 4984:1995 with latest amendment, Material Grade PE 63

1000

1067

1067470

... More
Excavation of trench as per cable route plan, 1.2 mtr deep, 300mm wide at the bottom along main line in normal soil, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by shahabad stone/bricks, clearing of route, 11 bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.

4.2

92718

389416.36

... More
Excavation of trench as per cable route plan, 1 mtr deep, 300mm wide at the bottom along main line in hard soil / murrum, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by bricks.

0.7

-

92716.38

... More
Excavation of cable trench 1m deep and 300mm wide across the track, for track crossing and refilling after laying of DWC/RCC/GI pipes. The work shall be done as per extant practice on W.C. Rly & instruction of Rly engineer at site.

300

211

63579

... More
Cutting of all types of Roads prepratory to trenching & excavation to depth of 1 Mtr X 300 mm wide approximately and refilling, after laying of RCC/GI/DWC pipe and to restore the road to original condition. The work shall be done as per extant practice

300

351

105300

... More
Preparation of Cable way 150 mm wide at the bottom and 300 mm deep in rocky area & refilling the same (after cable-laying) with concrete mixture of proportion 1:3:6 and grouting the ends at either side of the rocky portion using concrete mixture with Contractors own material.

920

913

840788

... More
Supply & laying of well burnt bricks of size 225x100x75mm inside the trench (with the brick length being perpendicular to cable route) after laying of cable in station area from Outermost to Outermost signal or at any other location as per instruction of Engineer at site.

35000

6

230650

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches. as per 17 approved cable route plan in the excavated trench, inside GI, DWC Pipes etc. taking due care while transporting and sealing both the ends after laying. The cables are to be laid as per extent practice of WCR and as per the instructions of engineer at site. This includes transportation of cable from the consignee depot to site or as per instruction of engineer incharge.

32

10106

323398.72

... More
Transportation & Laying of GI/DWC/RCC pipes along with collars in trenches at places wherever required as per the instruction of the engineer at site.

600

83

50118

... More
Transporting & Supply and installation of cable route indicator at interval of 50 mtrs. in trenches along the cable route as per specification. The work shall be done as per extant practice on WCR & the instruction of Rly engineer at site.

90

1236

111267

... More
Excavation, casting and plastering (above ground level) of Apparatus case foundation with contractors own Metal Sheet frame, cement, anchor bolts and other materials. Single case as per Drg No JBP/S&T/C/084

14

14331

200643.52

... More
Erection of apparatus cases.This includes filling of location foundation with river bed sand and plastering on top of the sand. Single case

14

1637

22927.52

... More
Fabrication and fixing of phenolic board in location box by providing all fixtures as per 22 Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. Lasing and dressing of cables/wires terminated with contractors own supply of lasing thread. The work shall be done as per instructions of Rly engineer at site. Single case

14

2315

32412.24

... More
Installation of Eqpt. (Relays, resistance, chargers & batteries etc.) & wiring of the same in apparatus cases as per location & circuit diagrams with contractor's own PVC wires and wiring 23 material. The work shall be done as per instruction of Rly engineer at site and approval of wiring material ( from RDSO approved firms) being used and extant practice in W.C. Rly). Wiring of relays should be with 16/0.2mm wire and all other equipments wiring by 2.5 sq mm multi strand wire of IS 394 of 1990 or latest. Single case

14

2186

30617.44

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following 24 items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per WCR practice. Apparatus case full size

14

663

9284.52

... More
Lettering numbering termination particulars, equipment's names etc legibly and neatly inside location boxes. Single case.

14

402

5634.44

... More
Installation & fixing of earth electrode assembly including earth wire connected 26 through GI wire 8 SWG supported on M.S. flat of size 6mm x 40mm to earth electrode for signaling Equipment. Contractor will bring Earth enclosure and all other material required for provision of earthing.

16

3925

62814.24

... More
Dismantling and releasing of Colour light signal, Location Box. Which includes dismantling of signal fittings complete & location box fitting complete. All dismantelled materials to be transported and stacked in the store of SSE/Sig/M/JBP or any other store of JBP Div as per consignee.

10

1175

11752.9

... More
Dismantling and releasing of lifting barriers and its fitting etc. This includes complete removal & transport of lifting barrier. All dismantelled materials to be transported and stacked in the store of SSE/Sig/M/JBP or any other store of WC railway as per consignee.

5

3050

15253.75

... More
Installation, testing and commissioning of electrically operated lifting barrier, (Supplied 29 in item no. 19 of supply portion) complete with Casting of cement concrete foundation for pedestal and boom rest post, cabling power supply connection & wiring with complete outdoor work.The work shall be done as per approved plan, extant practice on W.C. Railway & the instructions of Rly. Engineer at site.Testing and commissioning is to be done by OEM Engineer.

4

13468

53872.52

... More
Installation of Track device of SSDAC/MSDAC (Double rail contact of digital Axle counter) including digging of trench, track crossing, laying of double walled antirodent corrugated pipe from track device to location box /terminations, Fixing of deflector plates.(Double Walled 30 antirodent corrugated pipe made up of high density Polyethelene of required dia and all other accessories as per site requirement to be supplied by the firm).Casting of foundation for track side housing & erection of track side housing. Installation & Wiring & commissioning of EJB, Reset box, track side electronic inside the track side housing including supply of wires and other accessories for complete installation

4

14423

57693.56

... More
Installation of maintenance free Single Earth Pit which includes the following:- a) Excavation/ Auguring/ Boring of single earth pit of 100 mm to 125 mm dia to the depth of approx. 2.8 meter. b) Insertion of 3.0 meter electrode and penetrating it at least 0.2 meter by pushing gently with sledge hammer where the natural soil is assumed. c) Filling of earth pit with Earth Enhancement 31 Compound (EEC) in slurry form and backfilling. d) Carrying out exothermic weld connection on single earth electrode to a copper tape of 150x25x6mm. e) Carrying out exothermic weld connection on the copper tape of 150x25x6mm on Earth Electrode for connecting two 35 sq mm cables for redundancy. f) The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite moulds, clamps, weld metal powders. g) Digging a trench to a depth of at least 0.5 m and run the 02 (two) 35 sq mm earth conductor (procured against supply item) from Earth pit to MEEB. h) Routing and termination of 02 (two) 35 sq mm 300x25x6 mm MEEB, which is to be fixed inside the equipment room with 02 (two) insulation studs, with stainless steel Nuts & Bolts. i) 300 X 300 X 300 mm (inside dimension) concrete Earth pit with a concrete lid, approx 50 mm thick with pulling hooks, shall be provided to cover the pit. Back side of the cover will be painted in black and date of the testing and average resistance value shall be written in white paint.

2

9116

18232.96

... More
Preparation & submission of cable route plan of main & tail cables, cable corage plan, location particulars, CT rack particulars, meggering report, earth resistance particulars, traction bonding diagram and any other drawing / particular required in Auto CAD in minimum A3 size Each 32 sheet should have a block for signature of Railway Officials as well as block for signature of the firm, where signature shall be put up by the authorized signatory of the firm. The name of the work as given by the Railways shall be written on every sheet under the WORK column. One complete set of tracings and four sets of copies of complete above detailed particulars / drawings along with one CD to be supplied by the contractor in thick plastic folder. UNIT- PER station

1

26490

26490.75

... More
Termination of cable cores on ARA terminal/8-way/Fuse Block/Wago/Phoenix terminals on the cable termination rack. This includes all associated works of pulling out the cable from 34 underground, dressing of cable, making wiring tree with contractor lacing & threading material etc. This includes soldering of armour tree/ring of cables and connecting to Earth Bus bar. The work shall be done as per approved plan, extant practice on West Central Railways Railway & the instruction of Rly engineer at site. The termination of both ends of the cable core shall be counted as one No

200

13

2664

... More
Supply of High Availability Digital Axle Counter Single section Syestem complete with dual sensor as per RDSO specification no. RDSO/SPN/177/2012 with version 3 orlatest consisting of (1)Track side High availability Digital Axle Counter Unit DACF- 720P-2 nos. (2)High frequency Tx coil 01 and Rx coil (AD-711)(each set consists of webmounting type 2 nos. Tx coil & 02 nos. Rx coil)-02 sets (3)Vital RElay Box Model VR- 722-02 nos. duly wired with following relays:(a) Vital Relays QN1K,24V, 6F-6B- 02 nos.(b) Reset Relay QN1K, 24V,6F-6B-01 nos. (c) PR Relay QNN1,24V,6F-2B (Dual)- 01 nos. (4) Clamp with deflector plates and hardware -04 nos. (5) Reset box Model No.RB 259A-02 nos. (6) Surge Voltage Protection Device mounted on DIN Rail-0. INSPECTION BY RDSO

1

818594

818594.43



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.