West Central Railway Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

West Central Railway - WCR Tender

Goods
Telecommunication Services
Ireps
Opening Date24 Apr 2024
Closing Date20 May 2024
Tender Amount₹ 2,56,63,028.46 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
12 Volt Hooter 12 make Radix mindamacony or equivalent as per requirement of consignee.INSPECTION BY CONSIGNEE

2

293

587.62

... More
Supply of Electrically operated lifting barrier assembly with all spares & tool kit As per RDSO specification RDSO/SPN/208/2012. (Version 2) with Amendment -2 or latest. INSPECTION BY RDSO

2

410797

821594.76

... More
Retro reflective Board for mechanical and Electrical lifting barrier with retro refelective sheet Yellow. Drg No. S&T/JBP/09/004 .INSPECTION BY CONSIGNEE

120

183

21999.6

... More
Supply of Earth Leakage detector 8 channel card (2 channel card for monitoring 110V AC and 4 channel card for monitoring 24 V DC voltages, 1 card each for monitoring 60V & 110V DC ) as per RDSO Spec No RDSO/SPN/256/ 2002 with latest amendment.INSPECTION BY CONSIGNEE

1

107106

107106.65

... More
Supply of low maintenance Lead Acid Secondary Cells 2V /200 AH as per specification IRS 88/2004 with latest amendments (Make - Exide/LEBCO/Power Build)INSPECTION BY RDSO

60

7868

472095.6

... More
Supply of QNA1 (AC immunised relay), 8F-8B, 24VDC along with plug board (Base plate), retaining clips and connectors conforming to BRS:931A, IRS:S34 & IRS:S23 INSPECTION BY RDSO

30

5041

151236.3

... More
Supply of Time Element Relay (Clock work type) AG timer of Siemens Make (Nos RSSK 30/0052) or functional equivalent with timer range up to 120 seconds.INSPECTION BY CONSIGNEE

10

10189

101897

... More
Supply of Relay Non-AC Immune, plug-in-type, DC Neutral Line 60V 4F/4B, 5F/3B, 6F/2B contacts, 11 front and back contacts metal to metal, conforming to IRS: S 46 and firm's specification. The relay housing shall contain two miniature identical relays in mini group housing complete with base plate, Siemens make (RSSK 30/0011) ABB or functional equivalent As per site requirementINSPECTION BY RDSO

40

10037

401488

... More
Supply of Relay Plug In type two DC neutral line in mini group housing, complete with base plate 12 consisting of Top relay AC immunized & Bottom relay both AC immunized, each 60V, 5F/3B, contacts, front and back contacts metal to metal conforming to IRS: S46 and firms specification. Siemens make (RSSK 30/0078-1), ABB or functional equivalent As per site requirementINSPECTION BY RDSO

20

11923

238465.8

... More
Supply of Relay Plug In type, two DC neutral line, mechanically interlocked, in mini group housing, 13 complete with base plate each 60V, 4F/4B contacts, front and back contacts metal to metal conforming to IRS: S 46 and firms specification. Siemens make (RSSK 30/0012) ABB or functional equivalent As per site requirementINSPECTION BY RDSO

10

10600

106007.8

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. With holder 1.6 A (System, Rapid or Malnad Make).INSPECTION BY CONSIGNEE

400

98

39492

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. With holder 0.6 A (System, Rapid or Malnad Make).INSPECTION BY CONSIGNEE

400

94

37844

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. Without holder 1.6 A (System, Rapid or Malnad Make).INSPECTION BY CONSIGNEE

200

28

5734

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. Without holder 0.6 A (System, Rapid or Malnad Make).INSPECTION BY CONSIGNEE

200

28

5734

... More
Supply of two in two out (4 conductor) Knife edge disconnect terminal block set as per RDSO/SPN/189/2004 Ver. 1 with latest amendment.INSPECTION BY RITES

7400

89

662448

... More
Supply of end plate suitable for disconnect terminal.INSPECTION BY CONSIGNEE

740

17

12787.2

... More
Supply of steel carrier Din rail suitable for fixing disconnect terminal 1 meter long of dimension 35mm X 7.5 mm, 1mm thickness, unslotted INSPECTION BY CONSIGNEE

222

155

34516.56

... More
Supply of end stop suitable for disconnect terminal blockINSPECTION BY CONSIGNEE

1480

15

22540.4

... More
Supply of Earth Electrode assembly as per CR/753 Drawing INSPECTION BY CONSIGNEE

26

1330

34599.5

... More
Supply of Apparatus cases with miniature E Type Locks with keys. (E Type Locks & keys as per spec. No IRS: S-30/64 & RDSO Drg. No. SA 3376/M & SA 3377/M with latest amendments). Full Case as per Drg NoWS-8842 with latest alteration.INSPECTION BY CONSIGNEE

12

20278

243336.24

... More
Supply of Phenolic Laminated sheet, resin bonded 10mm thick, grade P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1974. INSPECTION BY CONSIGNEE

38

4397

167109.18

... More
Supply of cartridge fuse block made of PBT as per RDSO Drg. Nos. SA - 23748 Alt. 4 and Spec. Nos. IRS-S-75/2006 with latest amendment. Fuse block shall be suitable for round head type fuses.INSPECTION BY RDSO

300

198

59406

... More
Supply of lamp holder switches, two pin for location box make anchor or equivalentINSPECTION BY CONSIGNEE

4

102

411.4

... More
Supply of PVC insulated railway signalling indoor single core [ tinned jumper wire] 1X 0.6 mm dia as per RDSO spec. Nos. IRS:S-76/89 with latest amendments of various colours INSPECTION BY CONSIGNEE

1

2695

2695.46

... More
Supply of PVC insulated flexible wire 16/ 0.2 mm dia as per RDSO spec. Nos. IRS:S-76/89 with latest amendments of various colours INSPECTION BY CONSIGNEE

1

7565

7565.65

... More
Supply of PVC indoor cable 1x60x0.6 mm dia having colour coding of insulation of inner core shall be six colours viz. Blue, Red, Grey, Green, Brown & Black and shall be confirming to RDSO specification IRS:S: 76/89 with latest amendments.INSPECTION BY RDSO

0.5

-

126407.06

... More
Supply of PVC indoor cable 1x40x0.6 mm dia having colour coding of insulation of inner core shall be four colours viz. Yellow, White, Pink &Viloet and shall be confirming to RDSO specification IRS:S: 76/89 with latest amendments.INSPECTION BY RDSO

0.5

-

92015.74

... More
Supply of PVC indoor cable 1x24x1 mm dia having colour coading of insulation of inner core shall be six colours viz. Blue, Red, Grey, Green, Brown & Black and shall be confirming to RDSO specification IRS:S: 76/89 with latest amendments.INSPECTION BY RDSO

1

235594

235594.67

... More
Supply of flexible cable single core multistrend copper conductors, 1x6 sq.mm confirming to RDSO specification IRS:S: 76/89 with latest amendments.INSPECTION BY CONSIGNEE

1

77238

77238.71

... More
Supply of Jumper wire 1X1mm dia as per RDSO spec, IRS:S-76/89 with latest amendments of various coloursINSPECTION BY CONSIGNEE

2

8166

16332.68

... More
Supply of flexible cable single core multistrend copper conductors, 1x2.5 sq.mm confirming to RDSO specification IRS:S: 76/89 with latest amendments.INSPECTION BY CONSIGNEE

1

20651

20651.23

... More
Supply of ARA Terminal Block made of PBT as per Drg No SA 23741 alt 3 & spec. No IRS S 75/2006 with latest amendments with disconnecting links.INSPECTION BY RDSO

500

115

57875

... More
Supply of QNA1K (AC immunised relay), 8F-8B, 24VDC along with plug board (Base plate), retaining clips and connectors conforming to BRS:931A, IRS:S34 & IRS:S23INSPECTION BY RDSO

10

3628

36285.1

... More
Supply of Clamp meter digital type with AC/DC clamp, three & three forth digit (3&3/4 digit). INSPECTION BY CONSIGNEE. Metravi 4673, Motwani DCM 39A or equivalent

6

22507

135047.1

... More
Supply of Digital insulation and continuity tester as per technical specifications attached at Annexure A INSPECTION BY CONSIGNEE

8

8761

70092

... More
Supply of Double WalledCorrugated pipe made up ofPolyethylene of size 103.5 mminner dia and 40 120mm outer diain 6M straight length (Elect REX/TeleRex or similar) forunderground communication/signal cable protection 120 mmOuter Dia, 103.5 mm Inner Diain 6 Meter straight length as perBritish Std. No. BSEN 50086-1 &BSEN 50086 2,4 & BIS draftspecn. DOC HQ LTD 14 (5071) &ETD (5072) to specn. IS14930part II. NOTE: One coupler forjointing shall be supplied witheach 6 mtrs. length. Inspection by Consignee

300

372

111759

... More
Supply of Integrated cable route tracer, fault locator and RFID marker locator with High Power 12W Transmitter for effective long distance locating, 4 Active Locating Frequencies (577Hz, 8kHz, 33kHz, 200kHZ), depth range up to 9 meter, Passive Power Frequency, Current and resistance measurement in both transmitter 41 and receiver, Super Induction mode, with capability of Electronic Marker locating (both Passive and RFiD) and sheath fault locating in a single equipment , allows software to be downloaded from website, weight less than 2.5 kgs for Transmitter as well as Receiver, Signal Current Measurement in cable. (Model - 2273M-ID). Make 3M Model 2273 M-iD or equivalent INSPECTION BY RITES

5

574838

2874190.1

... More
Supply of Handheld Digital Earth Clamp Tester for clamp on earth/ground resistance measurement up to 1000 ohms. Accuracy 0.1 - 0.99 : 1%, 1 -49 : 1.5% Also measure current leakage up to 20A. No spines required for measurement. Model - CET 500 or equivalent / higher version. INSPECTION BY RITES

8

89012

712098.64

... More
Supply of digital multi meter digital type, three & three forth digit (3&3/4 digit) FLUKE 179/,MOTWANI M65 or Equivalent. INSPECTION BY CONSIGNEE

4

46203

184815.36

... More
Supply of Cable route locator/tracer set suitable for Detecting underground armoured optic fiber cable (OFC] and signaling cables with LCD Graphic. Display active/passive modes and depth range. 3M-10M. Make- RD 8100 or equivalent. INSPECTION BY CONSIGNEE

1

458724

458724.86

... More
Supply of permanently lubricated HDPE Telecom Duct, 40/33 mm, as per TEC GR/CDS/08-02 NOV-04 , along with accessories INSPECTION BY CONSIGNEE

7.8

60579

472521.58

... More
Supply of straight joint enclosure (SJC) complete with all accessories as per TEC Specification TEC/GR/TX/OJC-002/03/APR/2010 or latest of reputed make like Raychem, Birla VXL, 3M, shakti or similar. INSPECTION BY CONSIGNEE

24

3653

87694.32

... More
Supply of G.I. pipe 80 m dia medium grade with sockets and fittings of standard 6 meter length, as per specification no IS-1239 of 1990 & 1992 or latest with sockets at one end GI pipe should be of IS Specifications No. 75:1239 of 1990 & 1992.INSPECTION BY CONSIGNEE

138

562

77685.72

... More
Supply of E1 BER Tester of Stanlay make or better.INSPECTION BY CONSIGNEE

1

74771

74771.29

... More
Supply of Ethernet Tester of Stanlay make or better.INSPECTION BY CONSIGNEE

2

57088

114176.8

... More
Supply of Heat shrinkable straight through joint for UG cables with all accessories as per RDSO spec. no."IRS /TC/77/2012 (rev-3) with amend.-1 &2 or latest for 6 quad cable 0.9mm dia (TSF-2)joint suitable for 6 quad cable.INSPECTION BY RDSO

6

1917

11504.58

... More
Supply of isolation transformer cylindrical type for 2T joint as per RDSO spes No. TC/76/2000 or latest amendment Impedance 1120:470 . Material to be procured from RDSO approved firm .INSPECTION BY CONSIGNEE.

6

1874

11244.06

... More
Supply of Concrete Cable Marker as per drawing SDO/Cable Laying/020. INSPECTION BY CONSIGNEE

12

249

2994.36

... More
Circuit wiring/ Jumpering as perdiagram in the relay rack/IDFrack/tag block. This includepreparation 01 of jumper sheet dulychecked by firm's site supervisor& wire to wire testing as pre-wiring diagram. Any wrong jumper done by wire man will be consider & payment for wrongjumper will not be done by the railway. Jumper wire & other material will be supplied by contractor. UNITMENTIONED AS PER UNIT TO BEREAD AS PER JUMPER

1500

19

29550

... More
Supply & installation of powder coated Relay Rack Assembly complete with scaffolding, fixtures and accessories including MS Bars / relay frames for fixing of relay plug boards, string rods, fuse strips with bracket, 11 Way Bus Bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens' 02 type or equivalent & as per extant practice on W.C. Rly. Typical part list as per Annexure-B. Rack should be made of first class steel powder coated painting and rack manufacturer's certificate should be submitted. All runway for cables / wires shall be provided with PVC sleeve of proper size.Installation of Relay Rack Assembly including IDF pillars complete with wall supports, scaffolding, ladders, runway for cables, Relay/Relay group base plates, fixing of Tag blocks etc. The work shall be done as per approved plan, extant practice on W.C.Railway & the instructions of Rly. engineer at site. SUPPLY PORTION INSPECTION BY CONSIGNEE

1

44441

44441.38

... More
Supply & installation of Main Cable Termination rack complete with scaffolding, fixtures & 03 accessories including square bars for mounting 8-way terminal blocks, ladder, string rods, frame, base assembly, isulators, J bolt, nut/bolts & fasteners ,backelite sheet etc. Siemens type & as per extant practice on C. Rly. Typical part list as per Annexure-C. This includes installation of Cable Termination Racks Assembly complete including wall supports, scaffolding, 8 way/ARA terminal/Wago terminal & other necessary accessories etc. The work shall be done as per approved plan, extant practice on W. C. Railways & the instruction of Rly. engineer at site. SUPPLY PORTION INSPECTION BY CONSIGNEE

1

38735

38735.8

... More
Termination of cable cores on ARA terminal/8-way/Wago/Phoenix terminals in the cable termination 04 rack. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site.

500

12

6170

... More
Wiring in relay room: Fixing of Q series relay base plate/ Metal to Metal relay mini group and major group base plates, laying, lacing, dressing & packeting of 60/40/24 core PVC indoor cable and termination of 60/40/24 core cable on tag block & base plates & its soldering. Wiring of circuits to be done as per the approved diagram based on relay interlocking system using metal to metal/metal to carbon type relays and soldering after testing. This also includes fuse wiring, function wiring (Including interconnection between relay rack, & CT rack), power supply wiring (power wiring from power supply distribution board / rack to relay racks and cable termination racks with provision of wiring of ring connection with the help of contractors own single core flexible multistrand copper wire of 16 sq mm and 10 sq mm as per RDSO specification no. IRS-S 76/89 with latest amendment. 05 ..........16 sq mm wire for All 110V DC, 110V AC & 60V DC internal supply and 10 sq mm wire for balance supply is to be used) Materials required like jumper wire of 0.6 mm, 1.0 mm, 16/0.02 multistrand flexible etc, resin core, solder wire, lacing thread, adhesive tapes resistance, condensers, diodes, lugs etc of various ratings and capacity as per site requirement to arranged by the contractor free of cost and used after approval of Rly engineer at site. The jumper wire of 0.6mm, 1mm , flexible wire of 16/0.02, power wire of 16 & 10 sqmm equired for carrying out the indoor work shall be supplied by contractor as per RDSO specification no. IRS-S 76/89 with latest amendment after RDSO inspection. The quantity of jumper wire should be assessed jointly with the engineer in charge in beginning itself.). The work shall be done as per approved plan extant practice on W. C. Rly & the instruction of Rly engineer at site. Required quantity of 60/40/24 core PVC indoor cables will be supplied by Railway.PER TAG BLOCK = PER UNIT

36

1013

36470.88

... More
Soldering of tag block, fixing and wiring of G type fuse, bus bar wiring per tag block as per approved plan, extant practice of WCR & as per instruction of site engineer (Solder wire, resin core, etc. material will be supplied by contractor) Unit- Tag block

38

210

7984.94

... More
Charging of Low Maintenance Lead Acid Batteries with contractors own battery grade sulphuric 07 acid and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice on W.C. Rly & the instruction of site engineer. The sulphuric acid & distilled water to be used for charging shall conform to specification IS 266-1961 & IS 1070-1960 respectively. PER BATTERY =PER UNIT

60

77

4648.2

... More
Pluggimg of Q series relay, Metal to Metal relay/relay groups. Energisation of the system, making the panel through, functional test as per control table with contractor's own mock panel, break test if applicable to 08 be done in presence of Rly. Engineers. This will include wiring alterations required if any at that stage, preparation and submission of wire count detail register etc. The work shall be done as per extant practice on W.C.Rly& the instruction of Rly engineer at site. All type of resistances, capacitors etc required for commissioning have to be provided by the contractor free of cost. PER Unit-Per rack

1

2071

2071.11

... More
Detailed testing of wiring including continuity testing, functional testing, selection table and locking table testing with simulation panel including making panel through in the presence of Rly officials. The item 09 includes wiring of simulation panels as per standard practice. Erection and wiring of simulation panels shall be with contractors own materials. Signal lamps required for simulation panel will be supplied by contractor. The contractor shall hand over the system for railways testing and shall arrange technical man power, wireman and supervisor to facilitate this testing by railway. UNIT- PER relay room

1

105730

105730.48

... More
Lettering & Numbering of detail and description writing of particulars of terminations & equipments on relay rack, relays, cable termination rack, battery & power equipments, IPS, operating panel, axle counter etc 10 constituting entire system with contractor's own paint and writing material ("Asian" make or similar enamel paints or similar paint only to be used). This includes supply and fixing of teflon strips 3mm thick and 25 mm wide for each row of relays and cable terminations. The work shall be done as per extant practice on W.C.Rly& instruction of Rly engineer at site. Unit-per relay room

1

7394

7394

... More
Supply & installation of maintenance free earth consisting as per RDSO specification No. RDSO/SPN/197/2008 consisting of single earth pit which includes supply of 35 mm2/16 mm2/10 mm2 multistrand single core PVC insulated copper cable as per IS 694 for connecting main earth electrode to MEEB in the equipment room in duplicate as per manufacturers recommendations and as per RDSO specifications as follow: (1) Copper bonded steel electrode of 3.0 meters long, 17 mm diameter with copper bonding thickness of minimum 250 microns and UL listed and marked: 1 No. (2) Earth enhancement compound of RDSO approved brand supplied in sealed bag of minimum 10 KG: 3 Nos. (3) Copper strip of 150mm X 25 mm X 6 mm to terminate earth rod: 1 No. (4) Copper strip of 300mm X 25 mm X 6 mm (MEEB): 1 No. (5) Copper strip of 150mm X 25 mm X 6 11 mm (MEEB): 1 No. Installation of maintenance free earth includes:Digging/auguring/boring of single earth pit of 100 mm to 125 mmdiameter to the depth of approximately 2.8 meters. Insertion of three meters electrode and penetrating it atleast 0.2 meters by pushing gently with sledge hammer where the neutral soil is assumed. ........Filling of earth pit with earth enhancement compound (EEC) in slurry form and back filling. Carrying out exothermic weld connection of single earth electrode to a copper tape of 150 mm X 25 mm X 600 mm. Carrying out exothermal weld connection on the copper tape of 150 mm X 25 mm X 6 mm on earth electrode for connecting two 35 mm2 cable for redundancy. The exothermal welding material for bonding the earth system shall be procured from RDSO approved firms which includes graphite moulds, clamps, weld metal powder. 300 mm X 300 mm X 300 mm(inside dimension) concrete earth pit with a concrete lid approximately 50 mm thick with pulling hooks shall be provided to cover the pit. Back side of the cover will be painted in black and date of testing and average earth resistance value shall be written. SUPPLY PORTIONINSPECTION BY CONSIGNEE

6

31105

186634.62

... More
Fixing of ARA /WAGO Terminals and fuse blocks with provision of holes on hylem sheets and fixing by galvanised nuts & bolts.This includes provision of two additional holes on the hylam board on either side for cable conductor entry. The work shall be done as per Engg. at site. Per

2500

24

60100

... More
All work pertaining to Horizontal Dirctional Drilling (HDD)/Boring and trenchless cabling in normal soil by machine . It includes supply. transportation and insertion of self lubricated HDPE Pipe and laying of cables in boring under the track road plateform circulating area using By using self lubricated HDPE Pipe of 120mm outer 14 dia and 103.5mm innerdia in the bore . The depth of horizontal boring should be minimum 3 mtr, from rail flange road level lground level as per site requirement and as per instructions of Railway Engineer incharge. Thickness 3.5 to 4.1 mm as per specification no. IS 4984:1995 with latest amendment, Material Grade PE 63. By using self lubricated HDPE pipe of 120 mm outer dia and 103.5 mm inner dia in the bore and laying of cable in the bore under the track/road/circulating area.

1330

1067

1419735.1

... More
Excavation of trench as per cable route plan, 1.2 mtr deep, 300mm wide at the bottom along main line in normal soil, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm 15 thickness approximately before covering by shahabad stone/bricks, clearing of route, bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.

8.6

84519

726869.94

... More
Excavation of trench as per cable route plan, 1 mtr deep, 300mm wide at the bottom along main line in hard soil / murrum, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by bricks.

1.4

123287

172602.91

... More
Excavation of cable trench 1m deep and 300mm wide across the track, for track crossing and refilling after laying of DWC/RCC/GI pipes. The work shall be done as per extant practice on W.C. Rly & instruction of Rly engineer at site.

490

197

96662.3

... More
Cutting of all types of Roads prepratory to trenching & excavation to depth of 1 Mtr X 300 mm wide approximately and refilling, after laying of RCC/GI/DWC pipe and to restore the road to original condition. The work shall be done as per extant practice

460

326

150286.6

... More
Supply & laying of well burnt bricks of size 225x100x75mm inside the trench (with the brick length being perpendicular to cable route) after laying of cable in station area from Outermost to Outermost signal or at any other location as per instruction of Engineer at site.

42189

6

259040.46

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches. as per approved cable 21 route plan in the excavated trench, inside GI, DWC Pipes etc. taking due care while transporting and sealing both the ends after laying. The cables are to be laid as per extent practice of WCR and as per the instructions of engineer at site. This includes transportation of cable from the consignee depot to site or as per instruction of engineer incharge.

49

9212

451416.91

... More
Transportation & Laying of GI/DWC/RCC pipes along with collars in trenches at places wherever required as per the instruction of the engineer at site.

774

67

52082.46

... More
Transporting & Supply and installation of cable route indicator at interval of 50 mtrs. in trenches along the cable route as per drawing no. SDO/Cable Laying/020 placed in tender documents or latest drawing issued by WCR. The work shall be done as per extant practice on WCR & the instruction of Rly engineer at site.

279

1150

321062.04

... More
Excavation, casting and plastering (above ground level) of Apparatus case foundation with contractors own Metal Sheet frame, cement, anchor bolts and other materials. Single case as per Drg No JBP/S&T/C/084

22

14331

315296.96

... More
Erection of apparatus cases.This includes filling of location foundation with river bed sand and plastering on top of the sand. Single case

22

1637

36028.96

... More
Fabrication and fixing of phenolic board in location box by providing all fixtures as per Railway 26 Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. Lasing and dressing of cables/wires terminated with contractors own supply of lasing thread. The work shall be done as per instructions of Rly engineer at site. Single case

22

2315

50933.52

... More
Installation of Eqpt. (Relays, resistance, chargers & batteries etc.) & wiring of the same in 27 apparatus cases as per location & circuit diagrams with contractor's own PVC wires and wiring material. The work shall be done as per instruction of Rly engineer at site and approval of wiring material ( from RDSO approved firms) being used and extant practice in W.C. Rly). Wiring of relays should be with 16/0.2mm wire and all other equipments wiring by 2.5 sq mm multi strand wire of IS 394 of 1990 or latest. Single case

22

2186

48113.12

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per WCR practice. Appratus case full size

22

663

14589.96

... More
Lettering numbering termination particulars, equipments names etc legibly and neatly inside location boxes. Single case.

22

402

8854.12

... More
Installation & fixing of earth electrode assembly including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40mm to earth electrode for signaling Equipment. Contractor will bring Earth enclosure and all other material required for provision of earthing.

22

3925

86369.58

... More
Dismantling and releasing of Colour light signal, Location Box. Which includes dismantling of signal fittings complete & location box fitting complete. All dismantelled materials to be transported and stacked in the store of SSE/Sig/M/JBP or any other store of JBP Div as per consignee.

20

1175

23505.8

... More
Dismantling and releasing of lifting barriers and its fitting etc. This includes complete removal & transport of lifting barrier. All dismantelled materials to be transported and stacked in the store of SSE/Sig/M/JBP or any other store of WC railway as per consignee.

6

3050

18304.5

... More
Design and supply of Detailed Signalling Circuits including panel diagram (if required), SWRD, Control table, Route section plan , Selection Table, Fuse & Negative Tag Analysis, Contact Analysis , Relay Rack 33 Arrangement and wire count sheet etc. in A3 size, Completion circuit shall be ploted in Autocad. The contractor shall initially supply 2 Sets of circuits duly signed by the circuit designer having substantial experience on design side for making such circuits , complete for approval of Railways. Railway will return one set of circuit to the contractor duly approved with alterations/ corrections, if any. The contractor shall incorporated Railway's alterations/corrections in the original tracings & CD without any deviation and submit two copies of the modified circuits. Original tracings so modified & final CD complete in all respects alongwith 4 sets of final approved circuits (out of which one set shall be supplied in transparent polythene bags. Only two sheets of cicuits shall be placed in one polythene bag/cover each) shall be submitted to the Railways in case there are no further alteration suggested by Railways. PER STATION =PER UNIT

2

114178

228356.04

... More
Supply & installation of prefabricated Signalling and equipment housing having outer dimensions of 5000 mm X 3000 mm X 3080 mm made of 80 mm thick polyurethene foam snadwich panel for equipment / relay room complete with doors, elestomeric water proofing, ventilators, exhaust fans etc. sun/rain guard, PVC flooring, 34 Twin tube lights, fans etc. as per technical specification. Manufactures test and guarantee certificated to be submitted by the contractor. This also includes Excavation of trenches for foundation and construction of foundation as per technical specification, Errection, fixing of pre-fabricated building with all accessories supplied in item above, on the foundation erected. Double locking arrangement to be provided in the door of relay room. The work shall be done as per approved plan , extant practice on W.C. Railway & the instructions of Rly. Engineer at site.SUPPLY PORTIONINSPECTION BY CONSIGNEE

1

447490

447490.18

... More
Preparation & submission of cable route plan of main & tail cables, cable corage plan, location particulars, CT rack particulars, meggering report, earth resistance particulars, traction bonding diagram and any 35 other drawing / particular required in Auto CAD in minimum A3 size Each sheet should have a block for signature of Railway Officials as well as block for signature of the firm, where signature shall be put up by the authorized signatory of the firm. The name of the work as given by the Railways shall be written on every sheet under the WORK column. One complete set of tracings and four sets of copies of complete above detailed particulars / drawings along with one CD to be supplied by the contractor in thick plastic folder. UNIT- PER station

1

27554

27554.35

... More
Excavation, casting and plastering (above ground level) of main signal foundation as per 36 Drg.No.WCR/S&T/SIG/01 with contractor's own materials including cement and galvanised anchor bolts of standard size. The hole for cable entry should be kept as per site requirement and instruction of Rly engineer at site. The required scaffolding Ferma etc. for casting of foundation will have to be brought by the contractor at his own cost.

4

10131

40526.28

... More
Erection of CLS Post with Surface base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates and A/AG/C/P/G marker board , protective screen, 37 blanking of ladder (0.6mm MS sheet) if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. Wooden white cross- arms (1000x100 mm) to be provided by the contractor till the signals are commissioned with contractor's own material.

4

3860

15443.2

... More
Termination of tail cable on main & auxiliary signal units and wiring with contractor own material, 38 fixing of LED signal units etc. Flexible Single core copper wire 2.5 sq.mm (50/0.25) conforming to IS-694:1990 (as per aspect colour) and lugs etc. will be supplied by the contractor. This includes insertion of tail cables from ground to signal unit. The work shall be done as per instruction of Rly engineer at site.

4

1212

4849.96

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian paints / Berger / 39 Shalimar are to be supplied by Contractor. The work shall be done as per instructions of Rly engineer at site and extant practice on W.C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases also Termination particulars, equipment names etc. legibly and neatly inside location boxes etc.Appratus case Half size

4

349

1397.08

... More
Installation, testing and commissioning of electrically operated lifting barrier, complete with Casting 40 of cement concrete foundation for pedestal and boom rest post, cabling power supply connection & wiring with complete outdoor work.The work shall be done as per approved plan, extant practice on W.C. Railway & the instructions of Rly. Engineer at site.Testing and commissioning is to be done by OEM Engineer.

3

13468

40404.39

... More
Supply and installation, & Programming of RFiD Electronic Ball Marker with capability of saving the user specific data inside the marker memory chip, ( Data storage up to 256 bits) later readable by locator during locating floating coil to keep detection circuit always horizontal for better detection ) . This can be buried up to depth of 5 Ft. for Signaling& Telecom cables - Orangecolor as per TEC Spec. No- TEC /GR/TX/TIE-07/02 MAR2014 Make-3M & Model 1421XRiD or equivalent.SUPPLY PORTIONINSPECTION BY CONSIGNEE

40

2744

109787.6

... More
Modification, Alteration, Augmentation, Design, Manufacture, Supply, Installation, Testing & Commissioning in Existing HotStand By Electronic Interlocking (EI) System of with Electronic Interlocking (EI) as 42 per RDSO specification No. RDSO/SPN/192/2005 with latest amendment, as per Technical Requirement & Approved Signalling Plans & Diagrams. All materials related to alteration will be supplied by contractor. This item includes supply of necessary documents in the form of Tracings and 6 sets of Paper Print. This also includes 12 months warranty period of all supplied equipment. 10% spares to be kept after alteration as per RDSO guidelines. LC 25 KYOSAN, LC 262 WESTRACE

2

3682738

7365477.18

... More
S&T room: Wall panelling of room Supply and fixing on wall/roof. As per specification attached at Annexure D. PER UNIT = SQ FT

260

1834

476938.8

... More
Pre-surface preparation of S&T room: minor repairing & roof work. As per specification attached at Annexure E. PER UNIT = PER SQ FT

1540

248

382536

... More
Splicing of 24 fibre OFC from both sides for straight through joint and testing. This includes excavation of pit & backfilling & supply of all type of material and any other equipment of all types.

22

5150

113312.76

... More
Supply, Transportation & installation of prefab RCC OFC chamber (specification as per drawing attached No RAILTEL/2002 /PFB/0487 enclosed) & filling with river sand & termite chemical after jointing work is done.SUPPLY PORTIONINSPECTION BY CONSIGNEE

30

7879

236372.1

... More
Transportation and Laying of HDPE pipe as per approved cable route plan in the excavated trench, taking due care while transporting and laying the same in the trenches or other protective works. Both the ends of the duct should be sealed with end plugs before laying and should remain sealed till blowing is done.

7.8

6568

51233.68

... More
Blowing and drawing of OFC through already buried HDPE duct , taking due care while transporting and sealing both the ends after blowing. The cable should be blown according to the technical instructions of the manufacturer and the instructions of the site in-chargemanufacturer and the instructions of the site in-charge.

8.4

15128

127080.32

... More
Supply & installation of Thermo-Shrinkable jointing kit as per RDSO Specification No.IRS/TC/77/2006 (Rev.-1) with amnd.No.1 or latest amendments for straight through joint & derivation joint 49 suitable for 6 quad/PIJF.Installation includes of Thermo- shrinkable jointing kits for making (a) straight through joints with/without transformer for 6 quad cable, (b) derivation joint with/without transformer for 6 quad cable,© straight through joints with/without transformer for 10/20/50 pair jelly filled cable. As per site requirement.This includes all associate work of jointing required at site. SUPPLY PORTIONINSPECTION BY RDSO

24

3453

82895.04

... More
Provision/Fixing of 80MM dia G.I.pipe medium grade of IS specnno IS1239of 1990 &1992 orlatest with sockets at one endduly perforated and laying fixingon parapet wall of Briges/Drainage/culvertsincluding 50 masonry work at bothends and bending of pipe at boththe ends etc. as per enclosedDRG no. SK/CSTE/C/97/05 (GIpipe should have ISI Mak on it and contractor should submitmanufacturers certificate of GIpipe) as per the instructions ofengineer at site. The brickmasonry at the ends shall bedone with well-burnt bricks &cement mixture of 1:3 ratiodirective of Engineer in-charge.Perforation should be donebefore laying of GI pipes.

120

984

118096.8

... More
Horizontal boring by machine under railway track/road with laying of 120mm dia, HDPE/DWC pipes at the depth of minimum 2.1 meter form formation level(Level of earth below ballast) as directed by engineer-in- charge by trenchless technology. This includes supply laying of required HDPE/DWC pipe.

70

900

63000

... More
Making of straight through joint for under ground cable jelly filled cable/6 Quad cable with joint ing kits supplied against supply item and construction of bricks chamber for protection of joints with all contractor materials.

2

789

1578.12

... More
Placing and securing of cable route marker in trenches at the specified interval and at diversion 53 joint etc .along the cable route The work shall be done as per extant practice on WCR & the instruction of Rly engineer at site.

12

14

171

... More
Installation & testing of sliding boom. This includes Releasing (for alreaedy installed Sliding boom) , Excavation, erection, plastering, painting o f p it and concreting foundations fo r resting stand/meeting stand of mechanical type sliding boom arrangement. (approx 10 nos. stands).

1

44336

44336.17

... More
"Splicing, Termination, Testing &Commissioning of 24 fiber cablein fiber management systemwith all installation material,connectors, fittings, etc. as perinstructions of site engineer. FMSwith splicing materials suppliedas per schedule

4

11655

46622.52

... More
Cement concrete work in the ratio of 1:3:6 with contractors own as per instructions of site engineer.CU MTR=PER UNIT

1

4369

4369.28



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.