West Central Railway Tender

... More
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

West Central Railway - WCR Tender

Works
Electrical and Electronics
Ireps
Opening Date10 Feb 2025
Closing Date10 Mar 2025
Tender Amount₹ 9,97,42,033.87 
Notes
Download

Costs

Summary

Supply, Installation, Testing & Commissioning Of Indoor And Outdoor Signalling Equipments, Power Supply Equipments And Associated Works In Connection With The Provision Of Centralized Type Electronic Interlocking At Khajuraho- Barakhera-surajpura, In Panna-khajuraho Section And Balance Work Of Satna-panna & Rewa-sidhi Section In Connection With New Bg Rail Line In Jabalpur Division Of W.c Rly.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of PC/ Laptop based work station(make HP/DELL/IBM/Apple) with necessary software/programmes/ accessories,for Data input & configuration simulation and functional testing, 4 diagnostics and trouble shooting and commissioning of EI system.(Minimum configuration: HP intel core i7-10400 8GB/1000GB HDD/Window 11 professional brand) inspected by consignee. Suitable table and chair & 1KVA UPS with mimimum 30 minute backup and 1 no HP Laserjet P1108 of reputed makeshall be supplied by the contractor. The specifications of the PC/Laptop should be got approved from the Engineer-in-charge before supply. INSPECTION BY CONSIGNEE

2

58218

116436.3

... More
Instruments and Tool Kits required for Trouble shooting and repair of hardware and software for EI system should be supplied for station as required for schedule item 1 above. Details to be submitted by OEM in Annexure form. INSPECTION BY CONSIGNEE.

1

75249

75249.36

... More
Supply and Commissioning of SMPS based Integrated Power Supply System spares and tools as per RDSO specification No. RDSO/SPN/165/2023 Version 4.0 amendment 1 or latest amendment applicable as on date of tender notice and as per WCR drg. No. WCR/N-HQ/IPS/6 6 Line/EI/04 . For connecting IPS to battery bank, 10 meter each of Red and Black colour cable of size as per battery AH 2v/300AH capacity is to be supplied by tenderer, 12 core x 1.5 Sq. mm signaling cable for connecting IPS to status monitoring panel will be supplied by railway free of cost. Supply and commissioning of IPS should be as per RDSO letter no STS/E/IPS/General 03.04.2008. Note:-The firm will supply oneadditional SMR of rating110V, 20A in addition to 6 SMRs that they will supply as per drawing of IPS in this purchase. INSPECTION BY RDSO

2

1614240

3228480

... More
Supply of powder coated Main Cable Termination rack complete with scaffolding, fixtures & accessories including square bars for mounting 8-way terminal / WAGO - make terminal 7 blocks, ladders, string rods, frame, base assembly, insulators, J bolt, nut/bolts & fasteners, etc. Siemens' type & as per extant practice on W. C. Rly. Typical part list as per Annexure-B and rack arrangement shall be as per sketch SK-727. Rack should be made of first class steel powder coated painting and rack manufacturer's certificate should be submitted. All runway for cables / wires shall be provied with PVC sleeve of proper size as per annexure - B. INSPECTION BY RITES

8

33765

270124.08

... More
Supply of Relay, AC Immune, Plug-in type, Style QNA1, DC Neutral line, 24V 8F/8B or 8 12F/4B contacts, front and back contacts metal to carbon with plug board, retaining clips & connectors conforming to BRS:931A, IRS: S- 60, S- 34, S- 23, Interlocking pincode ABDGH. The relays of various contact configuration shall be as desire by consginee . INSPECTION BY RDSO

50

4291

214599.5

... More
Supply of QNA1K (AC immunized) Relay DC 24V, 1000 ohm relay, 6F/6B front and back contact metal to carbon complete with plug board, retaining clip and connectors confirming to IRS: S- 34, S- 23 & BRS: 931A (as applicable), Interlocking pin code CDEKY. INSPECTION BY RDSO

22

3945

86799.02

... More
Supply of Key Lock Relay AC immunized with different ward combinations ( Two extra set of same ward plates for Point Machines to be supplied with each group of points with each relay). 10 Siemens Make working on 24V 4F/4B equivalent(wards to be supplied with the consultation of Engineer in charge of work as per requirement of site and no additional cost will be paid for extra wards) The ward combination shall be A,B,C,D,E,F,G-Z). Before supply the Relay necessary approval to be taken from this office. INSPECTION BY CONSIGNEE.

28

9972

279220.76

... More
Supply of Relay, AC Immune, plug-in-type, Style QNNA1 twin DC neutral line relay 24V, 11 4F-4B,6F-2B contact each for LH & RH front and back contacts metl to carbon complete with plug board & retaining clip and connectors confirming to BRS 960,IRS:S60,S34 & IRS S23.Interlocking pincode ACDHJ.The relays of various contact configuration shall be as desired by consgnee. INSPECTION BY RDSO

26

4348

113055.54

... More
Supply of Time Element Relay (Clock work type) AG timer of Siemens Make (Nos RSSK 30/0052) or functional equivalent with timer range up to 120 seconds. INSPECTED BY RDSO

4

7882

31530.96

... More
Supply of Relay, AC Immune, plug-in-type, Style QSPA1, DC Neutral line, slow to pick 13 up, 24V 8F-4B contacts, front and back contacts metal to carbon complete with plug board, retaining clip & connectors conforming to BRS:933A,IRS:S60,S 34 & S 23. Interlocking pin code ABDEJ. INSPECTION BY RDSO

20

4379

87598.4

... More
Supply of 4 conductor disconnect screw less, spring cage type terminal blocks for test 14 and measurementsuitable for at least 2.5 mm2 conductor similar tomodel No. 280- 874 of WAGO make or model No. ST2.5- QATTRO- MT of PHOENIX or model No. DSDT-2.5 (2x2) of ELMEX make. Material to be suppliedafter approval of engineer in charge.(Wago part no280-874)as per RDSO specification RDSO/SPN/189/2004,Rev 3.0 INSPECTION BY RITES

18000

84

1519560

... More
Supply of End plate compatible to above screwlessterminals. The end plates shall be of different colour than that of disconnect terminal blocks. INSPECTION BY CONSIGNEE

1800

16

29268

... More
Supply of End Stop for above Din 35 Rail of WAGO or PHOENIX or ELMEX make or Similar. INSPECTION BY CONSIGNEE

1000

14

14370

... More
Supply of Din rail of dimension 35mm x 7.5mm, 1mm thickness, 1Mtr length, slotted compatible to above terminals of WAGO or PHOENIX or ELMEX make or Similar . INSPECTION BY CONSIGNEE

500

146

73305

... More
"Supply of Block Proving with Digital Axle Counter as per specification no. IRS:S- 105/2012 with latest amendment using UFSBI & Block Panel suitable for 25 KV AC RE area for single line operation.(a)Universal Fail Safe Block Interface as per RDSO Specification No. RDSO/SPN/ 18 147/2005 [latest amendment]. (b) SM panelRDSO drg. No. RDSO/S/32019 [Tentative]. (c) Relay rack with duel locking & sealing arrangement. Wiring diagram as per RDSO drg. No.RDSO/S/32020 [Tentative]. (d) Block telephone as per RDSO Specification No.RDSO/SPN/ 191/2005 [latest amendment]. (e) Relays for Single Line Section as listed below will be supplied with pre wired relay rack - 62 nos. (f) With each pair a set of user manual will be provided. INSPECTION BY RDSO "

2

954732

1909465.6

... More
Trans receiver, VHF, hand held Walkie-talkies set 5W (turned for rated power of 19 5Watts)Synthesized with 2200 MAH Ni-MH Battery pack,Configuration VH-3 Band 136-174 MHz full band alongwith one spare Battery pack of capacity 2200 MAH capacity and rapid charger as per specification enclosed. The VHF walkie-talkie shall be MIL standred compliance, duly verified by RDSO. INSPECTION BY CONSIGNEE.

5

7876

39383.7

... More
Supply of synthesised 25 watts VHF trans receiver set complete consisting of 25W VHF set SMPS power supply 12V/10A 3 db gain antenna,30 Mtr co-axial cable, technical service manual. INSPECTION BY CONSIGNEE.

2

15523

31046.26

... More
Supply of Data logger for monitoring status of important relay, complete with processor module to monitor 1024 digital and 48 anlog inputs as per RDSO spec. IRS -S-99/2006 with 22 latest amendments including power supply for adequate capacity, battery, fault diagnostic for failure analysis and modem card for monitoring DATA LOGGER , complete data logger and processor module ( as per annexure C) shall be placed in precedent rack of suitable size to be supplied by the contractor. INSPECTION BY RDSO

2

648767

1297535.96

... More
Supply of E1 to serial converter as per specification given (for reconfiguring the data logger net works as per RDSO guidelines Nos, STS/E/Data logger/vol. XX dated 12.09.2011) from station to test room at JBP. INSPECTION BY CONSIGNEE

2

30103

60207.08

... More
Supply and installation of cable termination panel with WAGO type disconnecting terminals blocks of size 1500MM x 500MM x 200MM thickness 1.6MM (16SWG) 150 no of 24 disconnecting terminal block with accessories (the box should be divided in two compartmenis 500MM from top with lock and bottom 1000MM closed fully with screws WAGO terminals 280-870 SUITABLE for cable dimensions maximum of 2.5 Sqmm Provision of easy and ensuing aesthetics INSPECTION BY CONSIGNEE

6

31897

191387.58

... More
Supply, installation, testing and commissioning of UL/FM/VDS/LPCB approved 25 Microprocessor based networkable analogue addressable and modular type of Fire alarm control panel with display, in bultcharging facilities and provision of GSM modulesuitable to send SMS to configured moblie no. Thepanel should be equipped with nos. of loopsand provision of expandability as per RDSO specification no RDSO/SPN/217/2021 ver 3.0 or latest (suitable for distributed as well as centralized). The Control panel shall be the central processing unit of the system, receiving and analyzing signals from probe type bimetallic heat detectors, UV&IR flame detectors, heat and smokemulti secsors, LHS/LHSD interface and manual callpoints, providing audible and visual information to the user. The panel shall have provision of connectivity of TCP-IP suitable for parogramming and remotemonitoring. The panel shall have dedicated Rs 232 serial port for direct PC or MODEM connection, for interfacing with existing data logger, optional remoteprinter. ( As per RDSO Specification no. RDSO/SPN/217/2021 ver 3.0 or latest) INSPECTION BY RDSO

10

110606

1106065.9

... More
Supply, installation, testing and commissioning of resettable, addressable multi sensor 26 ( Heat / Smoke) which is fully compatible with analogue addressableprotocol, Electronically addressed. ( As per RDSO Specification no. RDSO/SPN/217/2021 ver 3.0 or latest) .This item includes supply of the essential spares to the extant of 10% of the quantities installed will also be supplied by contractor as spare Qty . ( subject to minimum 1 number). INSPECTION BY RDSO

120

2742

329138.4

... More
Supply, installation, testing and commissioning of addressable, resettable manual call 27 point with integral short circuit isolator, having status LED for alarming & Stand by mode, Electronically addressed. ( As per RDSO Specification no. RDSO/SPN/217/2021 ver 3.0 or latest).This item includes supply of the essential spares to the extant of 10% of the quantities installed will also be supplied by contractor as spare Qty . ( subject to minimum 1 number).. INSPECTION BY RDSO

20

4866

97330.4

... More
Supply, installation, testing and commissioning of analogue type linear heat sensing 28 cable. ( As per RDSO Specification no. RDSO/SPN/217/2021 ver 3.0 or latest).This item includes supply of the essential spares to the extant of 10% of the quantities installed will also be supplied by contractor as spare Qty . INSPECTION BY RDSO

13860

201

2794314.6

... More
Supply, installation and testing and commissioning of module of LHS cable to be 29 integraced on fire alarm panel. ( As per RDSO Specification no. RDSO/SPN/217/2021 ver 3.0 or latest).This item includes supply of the essential spares to the extant of 10% of the quantities installed will also be supplied by contractor as spare Qty ( subject to minimum 1 number). INSPECTION BY RDSO

10

72362

723628.1

... More
Supply, installation and testing and commissioning of addressable Loop powered wall 30 sounder/alarm. ( As per RDSO Specification no. RDSO/SPN/217/2021 ver 3.0 or latest).This item includes supply of the essential spares to the extant of 10% of the quantities installed will also be supplied by contractor as spare Qty ( subject to minimum 1 number). INSPECTION BY RDSO

10

8406

84060.1

... More
Supply, installation, testing and commissioning of FRLS/Fire survival circuit integrity cablesi.e armored cable (2 core ,1.5 sqmm )& Power cable( 3 core multistrand 2.5 sqmm)( with all 31 accessories for connection of all fire alarm devices. ( As per RDSO Specification no. RDSO/SPN/217/2021 ver 3.0 or latest)( (each lot having 200 mtr armored cable and 50 mtr power cable(Additional quantity if required during installation shall be supplied by contractor without additional cost) .This item includes supply of the essential spares to the extant of 10% of the quantities installed will also be supplied by contractor as spare Qty . INSPECTION BY RDSO

10

22120

221208.6

... More
Supply, installation and testing and commissioning of Aspiration Type smoke Detection System complete. ( As per RDSO Specification no. RDSO/SPN/217/2021 ver 3.0 or latest) INSPECTION BY RDSO

10

146695

1466950.9

... More
Supply, Testing & Commissioning of CPVC pipe ( 25 mm dia) with all fixing material for aspiration detection Inspection by Consignee(1Number = 3 Mts). INSPECTION BY CONSIGNEE supply portion 34

800

705

564656

... More
Supply of PVC conduit Pipe having Diameter 25mm INSPECTION BY CONSIGNEE

4320

8

38534.4

... More
Additional input wiring to data logger From Potential Free Contact of Main unit of Automatic Fire Detection and Alarm System. INSPECTION BY CONSIGNEE supply portion

40

298

11952.8

... More
Supply of Steel Stool made of 1" x 1" steel square pipe size 12" x 12" square steel top aapprox. Height of the stool 18" inches approx. with duly powder coated, MAKE-Godrej,GEE-KEN or similar. .INSPECTION BY CONSIGNEE

-

-

36

... More
Supply of Ordinary Chair with out arm Cushion chair CH-1004 make- Godrej GEE-KEN or similar. INSPECTION BY CONSIGNEE

10

1401

14016.6

... More
Supply of office table similar to model T-8 Godrej, GEE-KEN make or similar model. INSPECTION BY CONSIGNEE

6

14183

85103.88

... More
Supply steel almira of size 1980mm height, 915 width & 485 depth of gauge 22 with 5 39 shelves Almira shall be made from CRCA stool sheet of 20 gauge (for panel partion) best brand Almira shall be 100% epoxy powder coated. Godrej, GEE-KEN make or similar model. INSPECTION BY CONSIGNEE

6

18923

113538.12

... More
Supply of Revolving chair for officer with cushioned seat and medium height back 40 made up for black leather and on wooden frame having suitable arrangement for changing the height etc. The revolving chair should have 5 Nos. of nylon wheels. make: GEE-KEN, Premier, Royal Koas, Harlison or similar. INSPECTION BY CONSIGNEE

6

21854

131129.58

... More
Supply of insulation MAT for Electrical purpose 25 mm thick size 2mx1m suitable for 3.3 KV to 11 KV (Class B) confirming to IS-15652-2006. INSPECTION BY CONSIGNEE

80

1633

130680.8

... More
Supply of VF Tapping transformer as per IRS/TC/22/76 with impedance ratio of 600:470 INSPECTION BY CONSIGNEE 43

10

583

5836.9

... More
Supply of tool box complete .as per annexure D INSPECTION BY CONSIGNEE

2

77042

154085.94

... More
Supply of Phenolic Laminated sheet, resin bonded 10mm thick, grade P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1974. INSPECTION BY RITES.

100

3952

395215

... More
Supply of Main Signal Post 140 mm outer dia 3.6 Mtr Length as per spec No IRS S 6/81 with latest amendments. INSPECTION BY CONSIGNEE

16

7645

122332.16

... More
Supply of Main Signal Post 140 mm outer dia 4.6 Mtr Length as per spec No IRS S 6/81 with latest amendments. INSPECTION BY CONSIGNEE

4

7721

30887.84

... More
Supply of Main Signal Post 140 mmouter dia 5.6 Mtr Length as per spec NoIRS S 6/81 with latest amendments. INSPECTION BY CONSIGNEE

4

9119

36476.76

... More
Supply of Shunt Signal Post with Base(GI Pipe of 80 mm Dia. Medium class In specification IS:1239 Pt-1/1990).INSPECTION BY CONSIGNEE

12

2834

34018.56

... More
Supply of Cast Iron Main signal surfacebase 140mm as per spec No IRS S 10and Drg No 49 2011/M with latestamendments, with CLS Ladder assemblycomplete for CLS signal 5.5 Mtrs long asper RDSO Drg. No. SA-23156. & signalfront staging complete assembly for CLSunit as per Drg. No RST/11413 & signal back staging as per extent W. C. Rlypractice. INSPECTION BY RITES

24

10922

262140.72

... More
Supply of CLS Unit 2 Aspect as per RDSO No. SA23003/A/M complete without lenses CLS signal transformer, MECR & Lamp holder, suitable for LED signal confirming to specification IRS S26/64.INSPECTION BY RITES

12

15586

187033.44

... More
Supply of CLS Unit 3 Aspect as per RDSO No. SA23002/A/M complete without lenses CLS signal transformer, MECR & Lamp holder, suitable for LED signal confirming to specification IRS S26/64. INSPECTION BY RITES

12

19558

234701.04

... More
Supply of position light LED based shunt signal Unit. as per RDSO No. SA23840. INSPECTION BY CONSIGNEE

12

9895

118740

... More
Supply of Calling-on Unit suitable for LED signal as per RDSO Drg no 24351(Adv.) Alt1 complete alongwith its base & clamping arrangement. INSPECTION BY RITES

6

2784

16706.7

... More
Supply of Offset bracket 5 - 1/2" suitable for 140mm outer dia of main signal. INSPECTION BY CONSIGNEE 55

8

1035

8281.36

... More
Supply of Offset bracket 3-1/2" for shunt signal unit. INSPECTION BY CONSIGNEE

8

506

4050.8

... More
Supply of 1 Way Junction Type Route Indicator unit as per RDSO No.SA23401-6 as per IRS:S-66/84amendment -1 or latest INSPECTION BY CONSIGNEE

4

23514

94058.04

... More
Supply of 2Way Junction Type RouteIndicator unit as per RDSO No.SA 23401-6 as per IRS:S-66/84amendment -1 or latest INSPECTION BY CONSIGNEE

7

32657

228601.59

... More
Supply of A/AG/C/P/G board as per RDSO Drg. No. SA 23455-56 RST-11445 & SA 23476-77 as applicable. With Clamp, nut & bolt etc. INSPECTION BY CONSIGNEE

12

590

7081.8

... More
Supply of Signal No. plates. as per Drg. enclosed. With Clamp, nut & bolt etc. INSPECTION BY CONSIGNEE

42

539

22648.08

... More
Supply of Hand Cuff Locks / Godrej Navtal lock with common key. INSPECTION BY CONSIGNEE

100

253

25384

... More
Supply of low maintenance Lead Acid Secondary Cells 2V/80 AH as per spec. IRS: S- 61 88/2004 with latest amendment. Cells will be supplied with microporousvent plug cum sealed floats, lead coatedinter cell connectors, lead coated brassnut bolts & washers in dry anduncharged condition. INSPECTION BY RDSO

180

2078

374205.6

... More
Supply of adjustable Track Feed Resistance disc type 30 ohms as per RDSO Drg. No. SA 20161-66/M (Adv)with latest amendments (with Phenolicmoulded base). INSPECTION BY CONSIGNEE

50

1344

67201

... More
Supply of B type choke tospecn.Nos.IRS.S.65/83 with latest amendments. INSPECTION BY CONSIGNEE

60

3810

228626.4

... More
Supply of Track feed battery chargers,110V AC as perSpecn.No.IRS:S.89/2013 ver 1.0 or lates. Charger shall be of 10 A outputcapacity . Charger shall be suitable forcharging 80 AH battery and no of cells2,3,4. INSPECTION BY RDSO

50

2401

120053

... More
Supply of track lead junction boxes asper Drg. Nos. RST11509 made from fiberglass along with terminal blocks. TheTLJB should be BLACK in colour.INSPECTED BY CONSIGNEE

150

1093

164091

... More
Supply of Relay, AC immune, Plug- in type, style QTA2 relay, DC Neutral track, Relay 9 66 Ohms, 2F/1B contacts, metal to carbon, complete with plug board, retaining clip and connectors conforming to BRS: 939A, BRS: 966 (Appendix F2) IRS: S- 34 & IRS: S- 23 as applicable. Inter locking pin code FGHKX. Inspected by RDSO

50

4644

232239

... More
Supply of Relay,AC immune, plug-in-type, Style QBAT DC biased track, 9ohms, 2F-2B 67 contacts,complete frontand back contacts metal to carboncomplete with plug board, retaining clip& connectors conforming to RDSO/SPN/84-88,IRS S 34 & IRS S23 Interlocking pin code ABEJX. INSPECTEDBY RDSO

5

3498

17490.95

... More
Supply of main LED signal UNIT 110V/AC as per RDSO specification No. RDSO/SPN/199/2010 Rev.1.1or latest. Suitable for existing CLS housing unit . RED Aspect INSPECTED BY RDSO

45

8009

360415.35

... More
Supply of main LED signal UNIT 110V/AC as per RDSO specification No. RDSO/SPN/199/2010 Rev.1.1 or latest. Suitable for existing CLS housing unit . YELLOW Aspect INSPECTED BY RDSO

60

8508

510503.4

... More
Supply of main LED signal UNIT 110V/AC as per RDSO specification No. RDSO/SPN/199/2010 Rev.1.1 or latest. Suitable for existing CLS housing unit. GREEN Aspect INSPECTED BY RDSO

45

9586

431375.4

... More
Route LED Signal Lighting 110 V Ac in existing CLShousing and compatable with AC LED ECR as per RDSO Spec RDSO/SPN/153/2023 REV 5.0 with Latest ver. INSPECTED BY RDSO

100

4419

441910

... More
Shunt LED Signal Lighting 110 V Ac in existing CLShousing and compatable with AC LED ECR as per RDSO Spec RDSO/SPN/153/2023 REV 5.0 with Latest ver. INSPECTED BY RDSO

75

4419

331432.5

... More
Calling on signal LED Signal Lighting unit 110 V AC in existing CLS Shousing and compatable with AC LED ECR as per RDSO Spec RDSO/SPN/153/2023 REV 5.0 with Latest ver. INSPECTED BY RDSO

10

5302

53029.2

... More
Supply of electrical point machine IRS make 110V DC operation(AC immunity 160V) 74 NONTRAIBLE, complete with lock,detector,cable termination box and slides for lock and detector(Rotary locking) as specification no. IRS : S-24/2002 amendment 1 or latest, requirement of point machine is 143 mm throw only as per RDSO drg. no. RDSO/S-10800. INSPECTED BY RDSO

20

53913

1078260.4

... More
Supply of non-deteriorating type lowvoltage cartridge fuse rate current 2Amp / 4A/6A/10/16 Amp round head type as per specification No.IRS/S/78/92 with latest amendment.The qty various rating supply shall be as desire by consignee INSPECTED BY CONSIGNEE

700

60

42343

... More
Supply of cartridge fuse block made of PBT as per RDSO Drg. No. SA - 23748Alt. 4 and Spec. No. IRS-S-75/2006 withlatest ammendment. Fuse block shall besuitable for round head type fuses. INSPECTED BY RDSO

700

169

118706

... More
Supply of PVC flexible cable multistrandwire copper conductor crossection 25 sq mm as per spec No IS 694/1990 withlatest amendment INSPECTED BY CONSIGNEE

2

354576

709152.94

... More
Supply of PVC flexible cable multistrandwire copper conductor crossection 16 sqmm as per spec No IS 694/1990 withlatest amendment INSPECTED BY CONSIGNEE

2

231244

462489.02

... More
Supply of PVC flexible cable multistrandwire copper conductor crossection 6 sqmm as per spec No IS 694/1990 withlatest amendment INSPECTED BYCONSIGNEE

2

99340

198681.34

... More
Supply of PVC flexible cable multistrandwire copper conductor crossection 10 sqmm as per spec No IS 694/1990 withlatest amendment INSPECTED BYCONSIGNEE

2

156363

312727.5

... More
Supply of PVC indoor cable 1 x 60 x 0.6 mm dia colour code for insulation of inner core shall be in six colour ,Blue ,Red, Green ,Brown and Black confirming to Spec No IRS-S-76/89 Amendment-3 Inspected by RDSO

5

145181

725907.05

... More
Supply of PVC indoor cable 1 x 40x o.6 mm dia colour code for insulation of inner core shall be in six colour ,Blue ,Red, Green ,Brown and Black confirming to Spec No IRS-S-76/89 Amendment-3 Inspected by RDSO

5

101220

506104.25

... More
Supply of PVC indoor cable 1 x 24 x 1 mm dia colour code for insulation of inner core shall be in six colour ,Blue ,Red, Grey, Green ,Brown and Black confirming to Spec No IRS-S-76/89 Amendment-3 or latest. Inspected by RDSO

3

146267

438803.67

... More
Supply of flexible multistrand copper wire size 16/0.2 to IS 694 of 3 Red and 3 black colour will be supplied. Inspected by CONSIGNEE.

5

6090

30454.4

... More
Supply of Ground connections, completeset suitable for IRS Make point Machinefor 85 ordinary turnout with tongue attachment insulation and other insulation No as per RDSO Drg. No.RDSO/S 3361/ 62/63 with latestamendment. This includes supply ofAcetyl bushes as per site requirement.(Ground connections for 52/60 Kgs. Railsas per RDSO drg. No. S-3362) INSPECTED BY CONSIGNEE

30

8511

255358.2

... More
Supply of "S" shape GI bend pipeMedium class, 50 mm dia. and of 1.2mtr length, for cable entry in pointmachines. GI pipe shall be as per spec.IS:1239 (Pt. I) - 2004 or latest. INSPECTED BY CONSIGNEE

30

308

9256.8

... More
Fixing , Supply of Pre-wired Crank Handle cum key lock relay box alongwith LEDs, TEKNIC/SIEMENS make push buttons, 8-way terminal strips / Wago Terminal, string rod, etc. as per Drawing No.RST.C.111A INSPECTED BY CONSIGNEE

4

11107

44431.28

... More
Supply of Tongue attachment nyloninsulation set to suit IRS point fitting complete consisting of one insulating plate & Insulating bush 3 Nos. Supplied As per RDSO Specn & Drg No RST- 10692.INSPECTED BY CONSIGNEE

-

-

88

... More
Supply of ARA/M6 Terminal Blocks withlinks made of PBT specn. No. IRS75/2006 (Rev.2) with latest amendments and RDSO Drg. No. SA-23741A INSPECTED BY RDSO

15000

76

1142550

... More
Supply of Apparatus cases with miniature E Type Locks with keys as per spec. No IRS S 30/64 & RDSO Drg. No.SA 3376/M with latest amendments.INSPECTED BY RITES

-

-

1725006

... More
Supply of Double Walled Corrugated pipe fire resistant and anti-rodent made up of 91 Polyethylene of Size 103.5 mm inner dia and 120mm outer dia in 6M straight length as per RDSO specification no. RDSO/SPN/204/ 2011 with latest amendment along with one coupler per every 6 meters. INSPECTED BY RITES

2000

395

791760

... More
Supply of GI pipe screwed and socketted100 mm dia. Medium Class, Nominal weight 12.5Kg per Meter as per spec. No. IS 1239 PT. 1/1990 INSPECTED BY RITES

600

1081

649056

... More
Supply of earth electrode assembly as per drg No CR/SK/-753 INSPECTED BY CONSIGNEE

150

1121

168228

... More
"Supply of Cable route locator/tracer set suitable for Detecting underground armoured optic fiber cable (OFC] and signaling cables with LCD Graphic. Display active/passive modes and depth range. 10M. Make CSCOPE DXL4 or equivalent. Inspection by Consignee"

2

450192

900385.16

... More
"Supply of HASSDAC Tool kit. Each setwill consists of i) Portable data analyzer(Downloading Event Logger Data foranalysis and report generation) =1 No.ii) Pure sine wave digital multimeterFluke Make (model -187) or Rishab Make(Model - 28S) =1 No. iii) 95 TrainsimulatorModel (TS267P) =1 No. iv) Card = 1 No.v) Dummy wheel = 1 No. vi) RingSpanner (17- 19, 24- 26) = 1 No. eachvii) Open end spanner ( 17-19, 24-26=1 No. each viii) Socket spanner withhandle = 1No. ix) Torque Wrench(Jaicom JPR 65 or equivalent 88NM) = 1No. x) Screw Driver no. 902 = 1 No. xi)Screw Driver no. 935 = 1 No. xii)Marking Jig for drilling (Drg No. F008300on D29 & D29A) = 1 No. xiii) Dummy load to check power supply (Resistive) =1 No" INSPECTED BY CONSIGNEE

1

65735

65735.34

... More
" Supply of Desk type Electronic Magneto Telephone as per spec No IRS TC 79/2000 or with latest Amendments. INSPECTED BY CONSIGNEE "

16

3252

52036.64

... More
Supply of automatic media changeover for UFSBI working on redundant channels for 97 data transmission on OFC/Quad. THE DTE side connects to UFSBI supplied under item No AII -79 and the line side connects RS-232,V24 ports of integrated multiplexer supplied under item no 93.it also includes supply of modem suitable for automatic media changeover. Inspected by CONSIGNEE

6

38684

232106.04

... More
Supply of Earth Leakage detector 8 channel card ( 4 channel card for monitoring 110V AC and 3 channel card for monitoring 24 V DC and one for 110V DC as per RDSO Spec No RDSO/SPN/256/2002 with latest amendment. INSPECTED BY RDSO

4

115569

462279.56

... More
Fuse auto changeover system for used in Railway Signaling system as per 99 RDSO/SPN/209/2012 rev.2 with latest amendments. One Autometic changeover unit comprise 32 nos. of external Non Deteriorating type or 'G' type fuse from 0.6 Amp to 4 Amp capacities which are in signaling circuits. System shall type 8 cards with monitoring arragngement of 4 fuses in one card. INSPECTED BY RDSO

50

25059

1252966

... More
Fuse auto changeover system for used in Railway Signaling system as per 100 RDSO/SPN/209/2012 rev.2 with latest amendments. One Autometic changeover unit comprise 24 nos. of external Non Deteriorating type or 'G' type fuse from 4 Amp to 10 Amp capacities which are in signaling circuits. System shall type 6 cards with monitoring arragngement of 4 fuses in one card. INSPECTED BY RDSO

10

41328

413281.6

... More
Supply of Resettable fuse, type Polymeric Positive Temperature Coefficient (PPTC) fuse of make Littlefuse/Fuzetec/Tyco/Bourn/Raychem, suitable fuses with trip current shall be supplied as per requirement given below. INSPECTED BYCONSIGNEE

-

-

10103.1

... More
Supply of G type PBT fuse holder with insert 1.6 Amp INSPECTED BY CONSIGNEE 103

220

72

15840

... More
Supply of G type PBT fuse holder with insert 0.6 Amp INSPECTED BY CONSIGNEE 104

180

72

12960

... More
Supply of PPTC type fuse thrsistor fuse. INSPECTED BY CONSIGNEE

-

-

9000

... More
Supply of rubber mating 10 mm thickness and width 0.8 Meter INSPECTED BY CONSIGNEE

160

89

14240

... More
Supply of fire extinguisher 4.5 Kgs CO2 gas ISI make CANEX,MINIMAX or vINTAX or Similar INSPECTED BY CONSIGNEE

10

5689

56890

... More
Supply of 230V, 10 KVA, 50Hz, single phase Silent type DG set comprising of Kirloskar make engine With Crompton Greeves make alternator Specification as per annexure-R. INSPECTED BY CONSIGNEE

10

287109

2871090

... More
Supply of Multiport Front end processor with one modem as per RDSO Spec. IRS.S.99/2006 or latest

-

-

722415

... More
Supply of Modem (E1-RS232)Compatible with existing UFSBI system to work on backup 109 media OFC (Viaunframed E1-2 mbps from STM interface)working voltage 24V DC(+/-20%).The Modem shall be compatible with UFSBI/Existing block system as per RDSO Spec .IRS-S: 105-2012 or latest suitable to existing UFSBI.(Warrenty perios 30 Months from date of supply.)

6

66080

396480

... More
Supply of off line UPS 2KVA with battery of backup time 60 minutes. INSPECTED BY CONSIGNEE

3

36119

108357.15

... More
Supply, Instalation, Testing and Commissioning with OEM certification of modular power supply arrangement for VDU ( 42" - 85" ) and embedded PC with input and output redundancy arrangement and hot pluggable modules having voltage & load current digital display on each module. Each set consisting of :- 1. Isolated inverters (master / slave with auto changeover )-2 Nos. 111 input : 110V DC , Output : 110V AC , 500VA (as per RDSO TAN No. STS/E/TAN/3012 Version 3.0 Dated 03.11.2022 ) 2. Isolated DC-DC converters - 02 Nos. connected in parallel with built in O-ring diode, active current sharing as per RDSO/SPN/165/2023 version 4.0 or latest (input: 110V DC, output : 24 VDC/10A ) 3. Input (redundancy) O-ring diode module with two input sources and one output supply along with potential free contacts, alarm and acknowledgment switch. 4. 3U stainless steel rack with back panel, mother board and front panel power connectors, power card for VDU panel. INSPECTION BY RITES.

9

230100

2070900

... More
Supply of VDU 55" PC based VDU Control terminal as per RDSO specification No 112 RDSO/SPN/192/2005 with latest amendments and RDSO TAN No. STS/E/TAN/3007 version 1 dated 02.11.2012.The display size of VDU shall be 55 inch. as per latest and guidelines NOTE: Technical requirements are attached herewith.. INSPECTION BY CONSIGNEE

3

325580

976742.31

... More
Installation, Wiring, testing, and commissioning of EI system with Hot standby architecture as supplied under item no 1 . It includes transportation of material from depot of consignee to the site.Erection and grouting of EI Relay Racks, fixing and wiring of all interfacing relays 1 (Vital and Non vital) installation and wiring of Microprocessor equipments, interface equipments, power supply equipments, and all other associated accessories to make complete EI system to be functional. NOTE: (i) Technical requirements are attached herewith. (ii) Contractor has to arrange simulator /simulation testing panel for testing and commissioning by selection table and square sheet for each Signalling function. (iii) Installation, Wiring, testing, and commissioning of EI system will be done by OEM after following all the guidelines/directives issued by RDSO from time to time.

2

544384

1088769.72

... More
Modification/alteration/augmentation of existing electronic interlocking (EI) system as per RDSO SPN No RDSO/SPN/192/2019 Ver 2.0 with latest arrangement as per approved signalling plans and selection table/locking table of stations( For phase working/ modification,LC removal etc) 2 technical specification as per special condition of contract.This also include necessary supplies for alteration/ modificationin VDU's software.This also include necessary alteration in earthing,data logger wiring,programming,software modification,,preparation of ST/LT/RSP/PD/YDU diagram and necessary wiring ,testing and commissioning of the system.

1

1539000

1539000

... More
Supply, Installation, Wiring, testing, and commissioning of embedded fanless PC based 3 Maintenance terminal as per RDSO specification No RDSO/SPN/192/2019 Ver 2.0 with latest arrangement and RDSO TAN No. STS/E/TAN/3007 version 1 dated 02.11.2012.The display size of VDU shall be 48 inch. as per latest and guidelines. INSPECTION BY CONSIGNEE.

2

406975

813951.88

... More
Supply, Installation, Wiring, testing, and commissioning of embedded fanless PC based 4 VDU Control terminal as per RDSO specification No RDSO/SPN/192/2019 Ver 2.0 with latest amendments and RDSO TAN No. STS/E/TAN/3007 version 1 dated 02.11.2012.The display size of VDU shall be 55 inch. INSPECTION BY CONSIGNEE

4

406975

1627903.88

... More
Manufacture and supply of DUAL VDU counter table with fixing provision for 55" inch display on each side, with two numbers of block counter table . Table is as per RVNL drawing No RVNL/S&T/SC/14/A/2018 attached in annexure. (Inspection by consignee)

5

182728

913642.5

... More
Earthing of EI Parimetric ring earth equipments, for covering SM office, Relay/Room, 6 IPS Room, Battery/Room Duty Room etc. to be done along with the supply of all requsite materials as per specifications recommended by manufacturer & latest RDSO guideline for covering of complete S & T service building as per instruction of site engineer.

2

89808

179617.86

... More
Training for Rly JE/SE/SSE/ Technicians, in Installation, Testing, Commissioing , Maintenace, Repair and Troubleshooting of EI system complete including supply of hard/soft copies of course module for each trainee.

4

10533

42132.96

... More
Training for Rly officers in Installation, Testing, Commissioning of EI system complete including supply of hard/soft copies of course module for each trainee.

2

10533

21066.48

... More
Installation of Cable Termination rack/Relay Racks Assembly complete including wall 9 supports, scaffolding, 8 way/ARA terminal/Wago terminal & other necessary accessories etc. The work shall be done as per approved plan, extant practice on W. C. Railways & the instruction of Rly. engineer at site(.All fixing material to be supplied by contractor) as per typical rack arrangement WCR DRG No S&T EQPT.BLDG/2013/Pt.1/4 The sting rod shall be fixed on phenolic laminated sheet.

8

1299

10396

... More
Termination of cable cores on ARA terminal/ on 8 way terminals/wago terminal in the cable termination rack,location boxes and else where . This includes all associated works of pulling 11 out the cable from under ground, peeling off insulation, dressing of cable,wiring tree with contractor lacing & threading material etc.This includes soldering of armour tree/ring of cables and connecting to Earth bus bar, The work shall be done as per approved plan, extent practice on WCR and instructions of Rly engineer at site.

34000

9

310420

... More
Installation, Wiring and testing of Integrated Power Supply System including Connection to change-over unit. This includes transportation, loading and unloading of IPS system complete and batteries from depot to the site of installation. The all supplies shall be wired right from IPS to power supply distribution board / rack with contractor's own wiring materials except 25sq mm wire (which is included in supply of IPS). The wiring shall be done with single core multistrand flexible copper wire of 6 Sq mm, 10 Sq mm, 16 Sq mm, 25 sq mm etc. as per IS:694 of 1990 or latest as per RDSO recommendation of IPS installation. This also includes instaliation of CT rack in IPS Room,fixing ofARA/Wago terminals. with connections suitable for 32 A. The 25 sq mm wire shall be used for connecting Batteries from IPS, 16 sq. mm power cable is to be used for wiring of 110V DC, 110V AC & 60V DC (internal) and for balance power supply 6 Sq mm, 10 sq mm power cable is to be used. All types of PVC wires, connectors, wiring material, ladders, DWC pipes etc as per site requirement are to be arranged by contractor as per instructions of railway engineer at site.

-

-

13

... More
Fabrication, supply & screen printing of SWRD/RSP/Laminated board/System 14 information board/ failure information board on white formica of 1200x600x3mm as per instruction of site engineer. Proportion payment will be made if size of board get increased or decreased. (INSPECTION BY CONSIGNEE)

2

1979

3958.46

... More
Data logger wiring: Fixing ,wiring,testing and networking of data logger complete along with accessories with contractors own materials . This includes programming of data logger for fault diagnostic in suitable structured language in consultation with railway.

2

22177

44354.04

... More
Lettering & Numbering of detail and description writing of particulars of terminations & equipments on relay rack, relays, cable termination rack, battery & power equipments, IPS, operating 16 panel, axle counter etc constituting entire system with contractor's own paint and writing material ("Asian" make or similar enamel paints or similar paint only to be used). This includes supply and fixing of teflon strips 3mm thick and 25 mm wide for each row of relays and cable terminations. The work shall be done as per extant practice on W.C.Rly & instruction of Rly engineer at site. 17

2

3840

7681.4

... More
Supply and installation of 20 pair CT box.

4

2341

9366.92

... More
Installation/shifting wiring and testing of control and other communication equipment like control phone, group phone, magneto phone, Auto phone, DTMF,VHF,PA system etc in panel room.

2

8270

16540.76

... More
Installation ,wiring, testing of control cum Indication panel, UFSBI KLR boxes, test board, fuse indication system, ELD, KLCR box and emergency key box etc. This includes laying & termination of of cable, if any from panel room to relay room in GI/HDPE pipe.

2

12313

24626.7

... More
Preparation of Cable Route Plan, Cable Coreage Plan, Location Particulars, Cable Meggering Report, Earth resistance particulars, Track Circuit jumper/bonding Diagram, Traction Bonding diagram, and any other drawing on Auto- CAD in A2/A3/A4, etc. size (as per instruction of engineer incharge). The basic rough sheets shall be prepared by Site Engineer of contractor in 20 consultation with Railway Supervisor for preparation of above mentioned plans/reports. Thereafter the contractor shall prepare the same in Auto- CAD in A2/A3/A4, etc. size (as per instruction of engineer incharge). Initially contractor shall supply 2 sets of documents complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/ corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects alongwith its soft copies and 4 sets of final completion drawings properly bound in steel clip jaw with cushion cover to railways.

2

39090

78180.6

... More
Excavation, casting and plastering (above ground level) of main signal foundation as 21 per Drg.No.WCR/S&T/SIG/01 with contractor's own materials including cement and galvanised anchor bolts of standard size. The hole for cable entry should be kept as per site requirement and instruction of Rly engineer at site. The required scaffolding Ferma etc for casting of foundation will have to be brought by the contractor at his own cost.

24

9984

239631.12

... More
Excavation, casting and plastering (above ground level) of Shunt Signal foundation as 22 per Drg.No.WCR/S&T/SIG/01 with Contractor's own materials including Cement and galvanised Anchor Bolts of Standard Size. The hole for cable entry should be kept as per site requirement and instruction of Rly engineer at site. The required scaffolding, Ferma etc for casting of foundation will have to be brought by the Contractor at his own cost.

12

3001

36022.2

... More
Erection of CLS Post with Surface base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates and A/AG/C/P/G marker board, blanking of ladder (0.6mm MS sheet) if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. Wooden white cross-arms (1000x100 mm) to be provided by the contractor till the signals are commissioned with contractor's own material.

24

3566

85588.32

... More
Erection of shunt signal with Surface Base, Post, Signal unit and fixing of No. plates. 24 The work shall be done as per instructions of Rly engineer at site. Wooden white cross-arms (1000x100 mm) to be provided by the contractor till the signals are commissioned with contractor's own material.

12

494

5935.68

... More
Termination of tail cable on main & auxiliary signal units and wiring with contractor 25 own wiring material, fixing of LED signal units etc. Flexible Single core copper wire 2.5 sq.mm (50/0.25) conforming to IS-694:1990 (as per aspect colour) and lugs etc. will be supplied by the contractor. This includes insertion of tail cables from ground to signal unit. The work shall be done as per instruction of Rly engineer at site.

24

1120

26884.08

... More
Termination of tail cable on Shunt signal units and wiring with contractor own wiring 26 material, fixing of LED signal unit etc. Flexible Single core copper wire 2.5 sq.mm (50/0.25) conforming to IS-694:1990 copper wire as per Rly. Standard and lugs etc. will be supplied by the contractor. This includes insertion of tail cables from ground to signal unit. The work shall be done as per instruction of Rly engineer at site.

12

365

4385.52

... More
Fixing of junction type route indicator 1way/2way on the top of the signal post. This also include fixing of LED signal etc.

11

770

8470.11

... More
Fixing & supply of stop board/GBD/SLB/BSLB with contactor's own fixing materials.The work shall be done as per instructions of Railway engineer at site

12

4148

49786.8

... More
Excavation, casting and plastering (above ground level) of Apparatus case foundation 29 with contractors own Metal Sheet frame, cement, anchor bolts with nuts & washers and other materials. The items also include additional earth work if required as per instruction of Rly. Engineer at site.

-

-

1109213.3

... More
Erection of apparatus cases.This includes filling of location foundation with river bed sand and plastering on top of the sand.

-

-

111549.55

... More
Fabrication and fixing of phenolic board/shelf in location box by providing all fixtures 31 and insulators as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. Lasing and dressing of cables/wires terminated with contractors own supply of lasing thread. The work shall be done as per instructions of Rly engineer at site.

-

-

192651.55

... More
Installation of Eqpt. (Relays, resistance, chargers & batteries etc.) & wiring of the same in apparatus cases as per location & circuit diagrams with contractor's own PVC wires and wiring 32 material. The work shall be done as per instruction of Rly engineer at site and approval of wiring material ( from RDSO approved firms) being used and extant practice in W.C. Rly). Wiring of relays should be with 16/0.2mm wire and all other equipments wiring by 2.5 sq mm multi strand wire of IS 694 of 1990 or latest.

-

-

114591.9

... More
Fixing of ARA /WAGO Terminals and fuse blocks with provision of holes on hylem sheets and fixing by galvanised nuts & bolts.This includes provision of two additional holes on the hylam board on either side for cable conductor entry. The work shall be done as per Engg. at site.

34000

8

290360

... More
Supply, fixing and wiring of lamp holders , switches, two pin (Backellite type) and bulbs(230V/110V) with contractor own material for location boxes (Anchor make or ISI mark) INSPECTED BY CONSIGNEE

65

69

4529.85

... More
Supply & Installation of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes. Consignee inspection under manufacturer certificate. INSPECTED BY CONSIGNEE

60

282

16930.2

... More
Fixing of relay base & wiring of cutting relays with contactor's own wiring and fixing materials in location boxes as per the instruction of site engineer.

-

-

36

... More
Digging and fixing of earth Electrode assembly as per Drg. No. S&T/CON/KOTA/Earthing/01 ALT-01 and connecting through stainless steel wire 8 SWG supported on MS flat of size 5mm x 40mm to earth electrode as per drg. No. T/2014/1 for signals and T 2014/5 for location boxes/ Apparatus cases. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. Supervisors. It should be documented and painted 37 on earth enclosure made of concrete. Only earth electrode will be supplied by Railway. All other material required for provision of earthing will be brought by the contractor. This earth can be provided for DPs block instruments & ELD etc. also, so as to achieve the desired earth resistance value. Earth enclosure to be manufactured & supplied by contractors own material of ratio 1:3:6, without cover. Additional connection of earth pipe including parallel connection with other earth pipes with the function shall be done using left over pieces of signaling cable. Laying of cable pieces shall be covered in laying of cable item and cable shall be supplied by Railways.

150

2133

319987.5

... More
Fixing and supply of maintenance free earth. This includes supply as per RDSO specification No.RDSO/SPN/197/2008 consisting of single earth pit which includes supply of 35 sq.mm / 16 sq.mm / 10 sq.mm multistrand single core PVC insulated copper cable as per IS 694 for connecting main earth electrode to MEEB in the equipment room in duplicate as per manufacturers recommendation and as per RDSO specification as follows: a) Copper bonded steel electrode of 3.0 Meter long, 17mm dia with copper bonding thickness of minimum 250 microns and UL listed and marked - 1 No. b) Earth enhancement compound of RDSO approved brand supplied in sealed bag of minimum 10 kg - 3 Nos. c) Copper strip of 150 x 25 x 6 mm to terminate earth rod - 1 No. d) Copper strip of 300 x 25 x 6mm (MEEB) - 1 No. e ) Copper strip of 150 x 25 x 6mm (SEEB) - 1 No. f) 38 Digging/Auguring/Boring of single earth pit of 100mm to 125mm dia to the depth of approximate 2.8M g) Insertion of 3 Mtr. Electrode and penetrating it at least 0.2 Mtr. By pushing gently with sledge hammer where the neutral soil is assumed. h) Filling of earth pit with earth enhancement compound (EEC) in slurry form and back filling. I) Carrying out exothermic weld connection of single earth electrode to a copper tape of 150 x 25 x 6mm. j) Carrying out exothermal weld connection on the copper tape of 150 x 25 x 6mm on earth electrode for connecting two 35 sq.mm. Cable for redundancy.. k) The exothermal welding material for bonding the earth system shall be procured from RDSO approved firms which includes graphite moulds, clamps, weld metal powder. l) 300 x300 x 300 mm (inside dimensions) concrete earth pit with a concrete lid approximately 50mm thick with pulling hooks shall be provided to cover the pit. Back side of the cover will be painted in black and date of testing and average resistance value shall be written.

12

33231

398783.28

... More
Erection, Fitting and Rail connection of Track Lead Junction Box with contractor's fixing material and jacketed wire rope including 7mm single groove galvanized channel pin for track lead connection including two vertical angle of size 40 x 40 x 5 mm 1200 mm length. This will include 40 drilling of holes in rails for track lead connections as per instructions of Rly engineer at site.PVC jacketed galvanized steel wire ropes of 6mm dia (7 x 19 strands) sheathed with PVC of 2mm wall thickness and over all thickness of 10mm for connection between the TLJB and the rails are to be used and to be supplied by the contractor. PVC sheath should be made of type 6 compound as per IS 5831 of 1970. Double wire ropes are to be connected between each rail and TLJB.

150

1148

172231.5

... More
Provision of bonding with contractor's materials including 7mm single groove 41 galvanized channel pin. This will include drilling of 7.2 mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own materials and tools as per instruction of Rly engineer at site.GI wires of 4mm dia (8 SWG) are to be used for jumpers across fish plates which should be supplied by the contractor free of cost.

800

130

104704

... More
Excavation of trench as per cable route plan, 1.2 mtr deep, 300mm wide at the bottom along main line in normal soil, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by shahabad stone/bricks, clearing of route, 43 bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.

12

53706

644482.56

... More
Excavation of trench as per cable route plan, 1 mtr deep, 300mm wide at the bottom along main line in hard soil / murum, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by Shahabad stone/bricks, clearing of 44 route, bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.

6000

74

446640

... More
Excavation of cable trench 1m deep and 300mm wide across the track, for track crossing and refilling after laying of DWC/ RCC/ /GI pipes and restore the track to its original condition. . The work shall be done as per extant practice on W.C. Rly & instruction of Rly engineer at site.

600

122

73224

... More
Cutting of all types of Roads/platform preparatory to trenching & excavation to depth 46 of 1 Mtr X 300 mm wide approximately and refilling, after laying of GI pipe and to restore the road to original condition. The work shall be done as per extant practice on W.C.Rly & instruction of Rly engineer at site.

400

161

64592

... More
Preparation of Cable way 150 mm wide at the bottom and 500 mm deep in rocky area 47 & refilling the same (after cable-laying in DWC pipe) with concrete mixture of proportion 1:3:6 and grouting the ends at either side of the rocky portion using concrete mixture with Contractor's own cement & other materials.

2000

606

1213660

... More
Supply & laying of Fly Ash bricks of size 225x100x75mm as per specificationconfirming to IS 12894-2002 inside the trench (with the brick length being perpendicular to cable route) after 48 laying of cable in station area from Outermost to Outermost signal or at any other location as per instruction of Site Engineer. Note: - Size of bricks to be got approved by Site Engineer. In case brick size is in variance with the size given in the tender schedule then proportionate payment on volumetric basis shall be paid to contractor subject to a maximum limit of schedule rate.

160000

6

1036800

... More
Fixing of GI pipes for crossing the culverts, stone bridges etc. and concreting the ends with brick masonry at both ends as per the instructions of Rly. Engineer at site with Contractor's 49 materials. The brick masonry at the ends shall be done with well-burnt bricks & cement mixture of 1:3 ratios. (Supply of GI pipes is not covered in this item). 3 perforation of 0.6mm dia per meter shall be made on the GI pipe as per the instructions of Engineer at site. This includes fixing with contractors own MS Chanel, clamps of proper size etc as per instructions of engineer at site.

600

62

37224

... More
Supply of Concrete Cable Marker as per drawing SDO/Cable Laying/020. Placing and 50 securing of cable route marker in trenches at the specified interval and at diversion joint etc .along the cable route The work shall be done as per extant practice on WCR & the instruction of Rly engineer at site. INSPECTED BY CONSIGNEE

360

271

97603.2

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches. The work shall be done as per extant practice followed on W.C.Railway and as per the instructions of Railway Engineer at site.

250

6083

1520895

... More
Laying of DWC/GI.RCC pipes alongwith collars in trenches where ever required as per extant practice on WC Rly and instruction of Rly engineer at site

2600

41

107874

... More
Jointing of 4/6 quad cable/RE main cable with heat shrinkable jointing kit for shifting of IBS,Block,Axle counter circuits or any other requirement.

-

-

53

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both ISI paint 54 is to be supplied by Contractor. The work shall be done as per instructions of rly engineer at site and extant practice on W.C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases also. Termination particulars, equipment names etc. legibly and neatly inside location boxes etc.

-

-

75444.52

... More
Lettering, numbering of signals point machine, track lead junction box, block joints, apparatus case.(The work shall be done as per instruction of site engineer.( Each item to be taken as one unit)

350

31

11105.5

... More
Lettering numbering termination particulars, equipments names etc legibly and neatly inside location boxes. 57

-

-

20724.4

... More
Supply of SWR diagram

2

2028

4056

... More
Providing brick masonary in the ratio of 1:6 cement and sand including plastering 20mm thick on eachside with contactor own 2nd class bricks

20

1822

36440

... More
Cement ,concrete work in the ratio of 1:3:6 with contactor own material as per instruction of site engineer

20

1993

39860

... More
Supply, Installation. Testing and commissioning of Class A type Surge protection system consisting of :- (a) Active ESE Lightening conductor as per NFC17-102 (b)Should provide radius of protection of 146 m Model no LAP-DX-250 or or equavalente, tested from international HV test laboratory certificate for the same.(c) Issued to OEM of lightening conductor should be attached with 61 the tender (d) CE certificate.(e) Authorisation letter from OEM should be attached with tender.(f) Stainless steel material with pointed tip. (g) Delta T should be greater and equal to 96 micro second. (h) Inhouse certificate from manufacturer should be provided with material.(i) It should be testable by means of external tester.(j)GI mast 5m with adopter head and base plate for connecting ESE lightening conductor.(k) Lightening counter testable of 6 digits non restable type of stainless steel of material having IP 65 protection manufacturer of 6 digit non restable type of stainless steel material having IP 65 protection.

2

107135

214270.92

... More
Shifting of Existing apparatus case with foundation by crane or by other means upto 2- 63 20 Mtr decided as per site engineer. (During shifting of location boxes signalling gears disconnection by railway representative). This includes all type of labours charges and filling of locations foundation with river bed sand and plastering on top of the sand.

6

6539

39239.88

... More
Transportation of material by 15MT capacity truck 66

5000

115

575000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.