West Central Railway Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
West Central Railway - WCR Tender
Civil And Construction
Ireps
Opening Date10 Dec 2024
Closing Date9 Jan 2025
Tender Amount₹ 84,88,982.1
Costs
EMD
₹ 1,69,800Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
JBP-N-TELE-TENDER-2024-19-JABALPUR DIVISION-S AND T/WEST CENTRAL RLYTender No
JBP-N-TELE-TENDER-2024-19Tender Authority
West Central Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply of 80mm GI Pipe medium class B of IS specifications 1239 of 1990. INSPECTION BY CONSIGNEE. 05
150
562
84441
... More
Supply of Ethernet Tester of Stanlay make or better. INSPECTION BY CONSIGNEE.
2
47790
95581.3
... More
Supply of Optical power meter (Type-B) as per TEC Specification No. TEC/GR/TX/OPM- 001/04. NOV.2013 with latest amendments. OEM Test certificate of each item shall be provided by contractor. INSPECTION BY CONSIGNEE.
12
21408
256907.52
... More
Supply of Mini OTDR MTS-5100 or equivalent of reputed make suitable for 1310/1550 07 nm fibre with resolution of 60 cm dynamic range of 31/29 db or better with all accessories, USB drive with a flash ROM of minimum 1Gb, AC adaptor/Charger, Rechargeable battery, Manuals, Hard and Soft carrying case etc. as per TEC specification No TEC/GR/TX/OTD 01/04 APR 2010 with latest amendments in force at the time of tender opening. INSPECTION BY RITES.
3
624915
1874747.79
... More
Supply of automatic fusion splicer fully automatic RTC microprocessor controlled ( ARC fusion type) splicer with VIDEO display, warm image processing, Heat oven, Fibre fixtures, battery 08 backup, high precision fibre cleaver, stripping tool and other compatible accessories of Fuzikura model No. FSM-50S or equivalent of reputed make along with sufficient no. of splice protection sleeves and bottle of isopropyl alcohol to be supplied for test splice. As per TEC specification No GR/OSM/01/03 APR 2005 with latest amendments in force at the time of tender opening. INSPECTION BY RITES.
2
871527
1743055.72
... More
Supply of pocket fault locator of OFC to indicate cable point of lose as per specification attached. INSPECTION BY CONSIGNEE.
1
62252
62252.01
... More
Supply of optical dual LASER source (1550nm/1310nm) as per TEC GR No. GR/SLS- 01/03 Feb-2005 Type C (Dual Wavalength) or latest. INSPECTION BY CONSIGNEE.
1
82170
82170.48
... More
Splicing of 24 fibre OFC from both sides for straight through joint and testing. This includes excavation of pit & backfilling & supply of all type of material and any other equipment of all types.
36
5150
185420.88
... More
Supply, Transportation & installation of prefab RCC OFC chamber (specification as per drawing enclosed) & filling with river sand & termite chemical after jointing work is done. SUPPLY ITEM INSPECTION BY CONSIGNEE.
36
7879
283646.52
... More
Transportation and Laying of HDPE pipe as per approved cable route plan in the 03 excavated trench, taking due care while transporting and laying the same in the trenches or other protective works. Both the ends of the duct should be sealed with end plugs before laying and should remain sealed till blowing is done.
10.5
6568
68968.41
... More
Blowing and drawing of OFC through already buried HDPE duct , taking due care while transporting and sealing both the ends after blowing. The cable should be blown according to the technical instructions of the manufacturer and the instructions of the site in-charge.
10.5
15128
158850.4
... More
Transportation & laying of GI/DWC/RCC Pipes along with collars in trenches at places wherever required as per the instruction of the engineer at site.
144
83
12028.32
... More
Supply & installation of Thermo-Shrinkable jointing kit as per RDSO Specification No.IRS/TC/77/2006 (Rev.-1) with amnd.No.1 or latest amendments for straight through joint & 06 derivation joint suitable for 6 quad/PIJF. Installation includes of Thermo- shrinkable jointing kits for making (a) straight through joints with/without transformer for 6 quad cable, (b) derivation joint with/without transformer for 6 quad cable,© straight through joints with/without transformer for 10/20/50 pair jelly filled cable. As per site requirement. This includes all associate work of jointing required at site. SUPPLY ITEM INSPECTION BY CONSIGNEE.
38
3453
131250.48
... More
Provision/Fixing of 80MM dia G.I.pipe medium grade of IS specn no IS1239of 1990 &1992 or latest with sockets at one end duly perforated and laying fixing on parapet wall of 07 Bridges/Drainage/culverts including masonry work at both ends and bending of pipe at both the ends etc. as per the instructions of engineer at site. The brick masonry at the ends shall be done with well- burnt bricks &cement mixture of 1:3 ratio. directive of Engineer in-charge .Perforation should be done before laying of GI pipes.
150
984
147621
... More
Excavation of trench as per cable route plan, 1.2 mtr deep, 300mm wide at the bottom along main line in normal soil, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by shahabad stone/bricks, clearing 08 of route, bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.
9.8
86303
845770.67
... More
Excavation of trench as per cable route plan, 1 mtr deep, 300mm wide at the bottomalong main line in hard soil / murrum, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately
2.8
123287
345205.81
... More
Excavation of cable trench 1m deep and 300mm wide across the track, for track crossing and refilling after laying of DWC/RCC/GI pipes. The work shall be done as per extant practice on W.C. Rly & instruction of Rly engineer at site.
280
197
55235.6
... More
Cutting of all types of Roads preparatory to trenching & excavation to depth of 1 Mtr X 300 mm wide approximately and refilling, after laying of RCC/GI/DWC pipe and to restore the road to original condition. The work shall be done as per extant
210
326
68609.1
... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches. as per 12 approved cable route plan in the excavated trench, inside GI, DWC Pipes etc. taking due care while transporting and sealing both the ends after laying. The cables are to be laid as per extent practice of WCR and as per the instructions of engineer at site. This includes transportation of cable from the consignee depot to site or as per instruction of engineer incharge.
19.5
9406
183436.11
... More
Supply, transporting & installation of cable route marker at interval of 50 mtr in trenches along the cable route as per drawing attached. The work shall be done as per extant practice on WCR & the instruction of Rly engineer at site. SUPPLY ITEM INSPECTION BY CONSIGNEE.
345
1150
397012.2
... More
Cement concrete work in the ratio of 1:3:6 with contractors own as per instructions of site engineer. Qty unit treated as Cubic Meter.
1
4369
4369.28
... More
Horizontal boring by machine under railway track/road for laying, HDPE pipes/cable at the depth of minimum 2.1 meter form formation level (Level of earth below ballast) and directed by engineer-in- charge by trenchless technology. Note : This does not include supply of HDPE pipe.
700
900
630000
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%