West Central Railway Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

West Central Railway - WCR Tender

Works
Telecommunication Services
Ireps
Opening Date16 Dec 2024
Closing Soon13 Jan 2025
Tender Amount₹ 1,04,67,529.39 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of low maintenance Lead Acid Secondary Cells 2V/ 80 Amp Hr. as per spec. IRS 88/93 with latest amendments. INSPECTION BY RDSO 05

16

2059

32946.56

... More
Supply of earth electrode assembly as per WCR drawing. INSPECTION BY CONSIGNEE

30

902

27075.6

... More
Supply of Apparatus Case with miniature 'E' type locks with keys (1 key per 5 location 06 boxes) of ward Nos. 41 (E type lock & key as per spec. Nos IRS S 30 & RDSO Drg.Nos. SA 3376/M & 3377/M respectively with latest Amendment) on both the doors, duly painted with red oxide.Single case as per Drg Nos WS- 8842/A with latest alteration. INSPECTION BY CONSIGNEE

16

13324

213194.72

... More
Supply of Apparatus Case with miniature 'E' type locks with keys (1 key per 5 location 07 boxes) of ward Nos. 41 (E type lock & key as per spec. Nos IRS S 30 & RDSO Drg.Nos. SA 3376/M & 3377/M respectively with latest Amendment) on both the doors, duly painted with red oxide.Half case as per Drg Nos WS- 8842/A with latest alteration. INSPECTION BY CONSIGNEE

4

12173

48692.2

... More
Supply of Phenolic Laminated sheet, resin bonded 10mm thick, grade P3 in standardsize of 1.22X1.22 Mtr as per spec. Nos IS 2036 of 1974. INSPECTION BY CONSIGNEE

22

4144

91182.52

... More
Supply of lamp holders , switches, two pin (Backellite type) and bulbs(230V/110V) for location boxes (Anchor make or ISI mark) INSPECTION BY CONSIGNEE

20

84

1683.8

... More
Supply of two in two out (4 conductor) Knife edge disconnect terminal block set as per RDSO/SPN/189/2004 with latest amendment. INSPECTION BY RITES 11

6000

83

502200

... More
Supply of end plate suitable for disconnect terminal. INSPECTION BY CONSIGNEE

250

12

3125

... More
Supply of steel carrier Din rail suitable for fixing disconnect terminal 1 meter long of dimension 35mm X 7.5 mm, 1mm thickness, unslotted. INSPECTION BY CONSIGNEE 13

160

148

23729.6

... More
Supply of end stop suitable for disconnect terminal block INSPECTION BY CONSIGNEE

500

10

5470

... More
Supply of cartridge fuse block made of PBT as per RDSO Drg. Nos. SA - 23748 Alt. 4 and Spec. Nos. IRS-S-75/2006 with latest ammendment. Fuse block shall be suitable for round head type fuses. INSPECTION BY RDSO

200

186

37320

... More
Supply of non deterioting type low voltage cartridge fuse r current 2Amp/4Amp in equal proportion round head type as per spec No IRS/S/78/92 with latest amendment. INSPECTION BY RDSO

200

80

16156

... More
Supply of GI pipe as per Specn. No. IS 1239 (Part-1)/1990 medium class normal bore of 100 mm, nominal mass of Tube 12.5 Kg (+/-) 10% per meter and complying parameters of specification. (INSPECTION BY CONSIGNEE

360

1203

433328.4

... More
Supply of Main Signal Post 140 mm outer dia 4.5 Mtr Length as per spec Nos IRS S 6/81 with latest amendments. INSPECTION BY CONSIGNEE

2

7504

15009.68

... More
Supply of Main Signal Post 140 mm outer dia 3.6 Mtr Length as per spec Nos IRS S 6/81 with latest amendments. INSPECTION BY CONSIGNEE

3

6655

19967.49

... More
Supply of Shunt Signal Post with Base (GI Pipe of 80 mm Dia. Medium class 49 IS Specification IS:1239 Pt-1/1990). INSPECTION BY CONSIGNEE

2

2218

4436.48

... More
Supply of Cast Iron Main signal surface base 140mm as per spec Nos IRS S 10 and Drg 20 Nos 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5 50 Mtrs long as per RDSO Drg. Nos. SA- 23156. & signal front staging complete assembly. INSPECTION BY CONSIGNEE 21

5

9742

48712.25

... More
Supply of Signal Nos. plates. as per Drg enclosed. INSPECTION BY CONSIGNEE

5

480

2404.25

... More
Supply of A/AG/C/P/G board as per RDSO Drg. Nos. SA 23455-56 RST- 52 11445 & SA 23476-77 as applicable INSPECTION BY CONSIGNEE

5

525

2628.5

... More
Supply of Hand Cuff Locks / Godrej Navtal lock with common key. INSPECTION BY CONSIGNEE

26

262

6834.36

... More
Non Metallic (FRP) colour light signal housing multi unit type for railway signalling 24 suitable for RE area TWO Aspects. Complete without lenses,lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Ver. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest INSPECTION BY CONSIGNEE

3

26983

80949.18

... More
Non Metallic (FRP) colour light signal housing multi unit type for railway signaling 25 suitable for RE area THREE Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M (Adv.) and as per SPEC. No. RDSO/SPN/194/2006 Rev.2.0 or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. INSPECTION BY CONSIGNEE

2

28267

56535.92

... More
Supply of Offset bracket 5 1/2" suitable for 140mm outer diaof main signal. INSPECTION BY CONSIGNEE

5

972

4863.95

... More
Supply of Offset Bracket 3-1/2" for shunt signal. INSPECTION BY CONSIGNEE

-

-

27

... More
Supply of position light shunt signal Unit. as per RDSO Nos. SA23840. INSPECTION BY CONSIGNEE

2

7744

15488.46

... More
Supply of 3 way Junction route indicator unit as per Drg. No. RDSO SA 23401-6 as IRS:S-66/84 amndt-1 or latest. INSPECTION BY CONSIGNEE

1

42130

42130.84

... More
Supply of Calling-on Unit as per RDSO Drg Nos 24351(Adv.) Alt1 INSPECTION BY CONSIGNEE

5

2078

10392.55

... More
Supply of Track feed battery chargers of 10A rating to spec. nos. IRS:S.89/93 with latest amendment. Charger shall be suitable for charging 80 AH battery. INSPECTION BY RDSO

6

1879

11274.42

... More
Supply of track lead junction boxes as per Drg. Nos. RST11509 made from fiber glass along with terminal blocks. The TLJB should be BLACK in colour. INSPECTION BY CONSIGNEE

56

856

47940.48

... More
Supply of B type choke to specn.Nos.IRS.S.65/83 with latest amendments. INSPECTION BY CONSIGNEE

6

2971

17830.5

... More
Supply of adjustable Track Feed Resistance, 30 ohms as per RDSO Drg. Nos. SA- 20161-66M/M with latest amendments (with Phenolic moulded base). INSPECTION BY CONSIGNEE

6

1051

6308.7

... More
Supply of PVC jacketed wire rope for Track Lead connections. PVC jacketed wirerope 35 should be of Galvanised steel wire rope 6 mm dia (6x19 stranded wire withsteel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1970. Reclaimed or recycled material should Nst be used. INSPECTION BY CONSIGNEE

1000

56

56370

... More
Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes. Consignee inspection under manufacturer certificate. INSPECTION BY CONSIGNEE

10

234

2340.2

... More
Supply o f Double Walled Corrugated pipe fire resistant and anti- rodent made up of 37 Polyethylene o f Size 103.5 mm inner dia and 120mm outer dia in 6M straight length as per RDSO specification Nos. RDSO/SPN/204/ 2011 with latest amendment along with one coupler per every 6 meters. INSPECTION BY CONSIGNEE

240

326

78355.2

... More
Supply of Electric Point Machine (Rotary locking Type) , 110VDC operation (AC 38 immunity 160V) NONTRAILABLE, complete with Lock detector, cable termination box and slides for lock and detector as per RDSO specification No.IRS:S-24/2002 with amendment 1 or latest. Requirement of point machine is 143mm throw only as per RDSO Drg. RDSO/S-10800. Make- Siemensas per Site. INSPECTION BY RDSO

4

105017

420070.56

... More
Supply of "S" shape GI bend pipe Medium class, 50 mm dia. and of 1 mtr length, for cable entry in point machines as per spec. IS:1239 (Pt. I) - 2004 or latest. INSPECTION BY CONSIGNEE

4

257

1030.48

... More
Supply of Ground connections, complete set suitable for Siemens Make point Machine 40 for ordinary turnout with tongue attachment insulation as per RDSO Drg. Nos. RDSO/S 3361-62 with latest amendment. This includes supply of Acetyl bushes as per site requirement. INSPECTION BY CONSIGNEE

4

7794

31179.64

... More
Supply of William stretcher nylon insulation set suitable for ground connections suitable ground connection of seimens point machines & as per spec IRS S 23 & 40/84 with latest amendment. INSPECTION BY CONSIGNEE

4

572

2289.48

... More
Supply Gauge Tie plate nylon insulation to suit IRS point fitting as per RDSO drg. to suit siemens point fitting complete consisting of insulating plate ,insulation bush & washer etc. INSPECTION BY CONSIGNEE

4

278

1112.04

... More
Supply of tool box complete with megger as per Annexure attached. INSPECTION BY CONSIGNEE

2

45489

90978.9

... More
Supply of hand Held digital multimeter, True RMS, rechargeable battery Model: SMM 606 or equivalent. INSPECTION BY CONSIGNEE

4

40335

161343.8

... More
Supply of Digital Insulation Tester 100V/250V/500V range of Model Rish insu 20 Make : RISHABH or MECO or equivalent INSPECTION BY CONSIGNEE

2

8829

17658

... More
Supply of straight joint enclosure (SJC) complete with all accessories as per TEC Specification TEC/GR/TX/OJC-002/03/APR/2010 or latest of reputed make like Raychem, Birla VXL, 3M, shakti or equivalent. INSPECTION BY CONSIGNEE

4

3653

14615.72

... More
Supply of permanently lubricated HDPE Telecom Duct, 40/33 mm, as per TEC GR/CDS/08-02 NOV-04 , along with accessories as below: (to be procured from RCIL approved sources) INSPECTION BY CONSIGNEE 49

1

52433

52433.9

... More
Supply of End Plug INSPECTION BY CONSIGNEE 50

4

38

155.52

... More
Supply of Cable Sealing Plug. INSPECTION BY CONSIGNEE 51

4

52

210.56

... More
Supply of Plastic Coupler. INSPECTION BY CONSIGNEE

4

52

210.56

... More
Supply of Heat shrinkable straight through joint for UG cables with all accessories as per RDSO spec. no."IRS /TC/77/2012 (rev-3) with amend.-1 &2 or latest for 6 quad cable 0.9mm dia (TSF-2)joint suitable for 6 quad cable. INSPECTION BY RDSO

6

1917

11504.58

... More
Termination of cable cores on ARA terminal/8-way/Fuse Block/Wago/Phoenix terminals on the cable termination rack. This includes all associated works of pulling out the cable from 01 underground, dressing of cable, making wiring tree with contractor lacing & threading material etc. This includes soldering of armour tree/ring of cables and connecting to Earth Bus bar. The work shall be done as per approved plan, extant practice on West Central Railways Railway & the instruction of Rly engineer at site. The termination of both ends of the cable core shall be counted as one No

1600

13

21312

... More
Excavation of trench as per cable route plan, 1.2 mtr deep, 300mm wide at the bottom along main line in normal soil, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by Shahabad stone/bricks, clearing of route, 02 bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.

1

92718

92718.18

... More
Excavation of trench as per cable route plan, 1 mtr deep, 300mm wide at the bottom along main line in hard soil / murum, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by Shahabad stone/bricks, clearing 03 of route, bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.

0.5

-

66225.99

... More
Preparation & submission of cable route plan of main & tail cables, cable corage plan, location particulars, CT rack particulars, meggering report, earth resistance particulars, traction bonding diagram and any other drawing / particular required in Auto CAD in minimum A3 size Each 04 sheet should have a block for signature of Railway Officials as well as block for signature of the firm, where signature shall be put up by the authorized signatory of the firm. The name of the work as given by the Railways shall be written on every sheet under the WORK column. One complete set of tracings and four sets of copies of complete above detailed particulars / drawings along with one CD to be supplied by the contractor in thick plastic folder. UNIT- PER station

1

26490

26490.75

... More
Preparation of cable duct 150mm x 300mm deep for laying of cable in rocky area and refilling the duct (after cable laying) with concrete mixture of proportion 1:3:6 and grouting the ends at either side of the rocky portion using concrete mixture with contractors own cement and other materials.

1000

800

800930

... More
Excavation of cable trench 1m deep and 300mm wide across the track, for track crossing and refilling after laying of DWC/RCC/GI pipes. The work shall be done as per extant practice on W.C. Rly & instruction of Rly engineer at site.

240

185

44575.2

... More
Cutting of all types of platforms, trenching & excavation to depth of 300 mm x 300mm 07 wide approx. and refilling after lying of GI pipes and repairing the platform to restore to original condition. The work shall be done as per extant practice on W.C.Rly and as per instructions of Rly. Engineer at site.

300

268

80448

... More
Cutting of all types of Roads preparatory to trenching & excavation to depth of 1 Mtr X 08 300 mm wide approximately and refilling, after laying of GI pipe and to restore the road to original condition. The work shall be done as per extant practice on W.C.Rly& instruction of Rly engineer at site.

96

307

29530.56

... More
Supply & laying of well burnt bricks of size 225x100x75mm inside the trench (with the brick length being perpendicular to cable route) after laying of cable in station area from Outermost 09 to Outermost signal or at any other location as per instruction of Site Engineer. Note: - Size of bricks to be got approved by Site Engineer. In case brick size is in variance with the size given in the tender schedule then proportionate payment on volumetric basis shall be paid to contractor subject to a maximum limit of schedule rate.

8500

5

49130

... More
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item 10 includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P. (Cables will be maggered before and after its laying by contractor under supervision of Railway Representative and he will submit the maggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. This includes transportation of cable to site from depot. 11

36000

9

356400

... More
Removal of PRC Sleeper in the way of cable route.

100

99

9990

... More
Patching work in old location box consisting 1) Digging of pit, cleaning of earth from all sides, breaking of seal of location boxes removal sand from location, marking of new cable holes 2) 12 insertion of cable from ground 3) making place for cable termination in old location, shifting & termination of ARA/Two in two out terminal, fuse etc, after removal and termination including fixing of ARATwo in two out terminal, . 4) Termination of cable in old location 5) Filling of sand and plastering to all sides upto 50mm below ground level.

10

6044

60444

... More
Transportation & Laying of GI/DWC/RCC pipes along with collars in trenches at places wherever required as per the instruction of the engineer at site.

240

73

17568

... More
Cement ,concrete work in the ratio of 1:3:6 with contactor's own material as per instruction of site engineer.

20

4113

82276.4

... More
Fixing of ARA /WAGO Terminals and fuse blocks with provision of holes on hylem sheets and fixing by galvanised nuts &bolts.This includes provision of two additional holes on the hylam board on either side for cable conductor entry. The work shall be done as per Engg. at site.

3000

21

63180

... More
Termination of cable cores on ARA/ disconnecting type terminal, fuse blocks, 8 way 16 terminals block in the apparatus cases. This includes all associated works of pulling out the cable from underground, dressing of cable, making wiring tree etc. This includes soldering of armour tree/ring of cables and connecting to copper plate through GI wire bus bar in location boxes. The work shall be done as per location plans and instructions of Rly engineer at site.

6000

15

94740

... More
Excavation, casting and plastering (above ground level) of Apparatus case foundation with contractors own Metal Sheet frame, cement, anchor bolts and other materials. Single case as per Drg No JBP/S&T/C/084

16

12560

200962.24

... More
Excavation, casting and plastering (above ground level) of Apparatus case foundation with contractors own Metal Sheet frame, cement, anchor bolts and other materials. Half case as per Drg No JBP/S&T/C/085

4

12196

48785.32

... More
Erection of apparatus cases.This includes filling of location foundation with river bed sand and plastering on top of the sand. Single case

16

1435

22964

... More
Erection of apparatus cases.This includes filling of location foundation with river bed sand and plastering on top of the sand. Half Case.

4

1098

4392.16

... More
Fabrication and fixing of phenolic board in location box by providing all fixtures as per 21 Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. Lasing and dressing of cables/wires terminated with contractors own supply of lasing thread. The work shall be done as per instructions of Rly engineer at site. Single case

16

2028

32463.84

... More
Fabrication and fixing of phenolic board in location box by providing all fixtures as per 22 Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. Lasing and dressing of cables/wires terminated with contractors own supply of lasing thread. The work shall be done as per instructions of Rly engineer at site. Half Case.

4

1828

7314.04

... More
Installation of Eqpt. (Relays, resistance, chargers & batteries etc.) & wiring of the same in apparatus cases as per location & circuit diagrams with contractor's own PVC wires and wiring 23 material. The work shall be done as per instruction of Rly engineer at site and approval of wiring material ( from RDSO approved firms) being used and extant practice in W.C. Rly). Wiring of relays should be with 16/0.2mm wire and all other equipments wiring by 2.5 sq mm multi strand wire of IS 394 of 1990 or latest. Single case

16

1916

30666.08

... More
Installation of Eqpt. (Relays, resistance, chargers & batteries etc.) & wiring of the same in apparatus cases as per location & circuit diagrams with contractor's own PVC wires and wiring 24 material. The work shall be done as per instruction of Rly engineer at site and approval of wiring material ( from RDSO approved firms) being used and extant practice in W.C. Rly). Wiring of relays should be with 16/0.2mm wire and all other equipments wiring by 2.5 sq mm multi strand wire of IS 394 of 1990 or latest. Half case

4

1333

5332.76

... More
Excavation, casting and plastering (above ground level) of main signal foundation as 25 per Drg.No.WCR/S&T/SIG/01 with contractor's own materials including cement and galvanised anchor bolts of standard size. The hole for cable entry should be kept as per site requirement and instruction of Rly engineer at site. The required scaffolding Ferma etc. for casting of foundation will have to be brought by the contractor at his own cost.

5

10131

50657.85

... More
Erection of CLS Post with Surface base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates and A/AG/C/P/G marker board 26 , protective screen, blanking of ladder (0.6mm MS sheet) if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. Wooden white cross- arms (1000x100 mm) to be provided by the contractor till the signals are commissioned with contractor's own material.

5

3860

19304

... More
Excavation and Casting of shunt signal foundation as per Drg.No. SK 749 based on 27 drawing no .RST-11173 with contractor's own materials including cement and anchor bolts of standard size. The hole for cable entry should be kept as per site requirement & instruction of railway engineer at site. The required scaffolding, Ferma, etc for Casting of foundation will have to be brought by the contractor at his own cast.

2

3553

7107.52

... More
Erection of shunt signal with Surface Base, Post, Signal unit and fixing of No. plates. 28 The work shall be done as per instructions of Rly engineer at site. Wooden white cross-arms (1000x100 mm) to be provided by the contractor till the signals are commissioned with contractor's own material.

5

632

3161.1

... More
Termination of tail cable on Shunt signal units and wiring with contractor own material, 29 fixing of LED signal unit etc. Flexible Single core copper wire 2.5 sq.mm (50/0.25) conforming to IS- 694:1990 copper wire as per Rly. Standard and lugs etc. will be supplied by the contractor. This includes insertion of tail cables from ground to signal unit. The work shall be done as per instruction of Rly engineer at site.

2

468

936.1

... More
Termination of tail cable on main & auxiliary signal units and wiring with contractor 30 own material, fixing of LED signal units etc. Flexible Single core copper wire 2.5 sq.mm (50/0.25) conforming to IS-694:1990 (as per aspect colour) and lugs etc. will be supplied by the contractor. This includes insertion of tail cables from ground to signal unit. The work shall be done as per instruction of Rly engineer at site.

5

1212

6062.45

... More
Installation & fixing of earth electrode assembly as per drg. No. CR/SK-753 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40mm to earth 31 electrode for signaling Equipment such as lever frames, apparatus cases, signals, relay racks, block instruments etc. as per RE manual. The earth value should be less than 10 ohms including the lead wire. It should be documented and painted on earth enclosure made of concrete (only earth electrodes will be supplied by Rly.) Contractor will bring Earth enclosure and all other material required for provision of

30

3440

103218.3

... More
Erection, Fitting and Rail connection of Track Lead Junction Box with contractor's fixing material and jacketed wire rope including 7mm single groove galvanized channel pin for track lead connection including angle of size 40 x 40 x 5 mm 1200 mm length. This will include drilling of holes 33 in rails for track lead connections as per instructions of Rly engineer at site. PVC jacketed galvanized steel wire ropes of 6mm dia (7 x 19 strands) sheathed with PVC of 2mm wall thickness and over all thickness of 10mm for connection between the TLJB and the rails are to be used and to be supplied by the contractor. PVC sheath should be made of type 6 compound as per IS 5831 of 1970. Double wire ropes are to be connected between each rail and TLJB.

50

1710

85516

... More
Provision of bonding with contractor's materials including 7mm single groove 34 galvanized channel pin. This will include drilling of 7.2 mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own materials and tools as per instruction of Rly engineer at site GI wires of 4mm dia (8 SWG) are to be used for jumpers across fish plates which should be supplied by the contractor free of cost.

100

226

22627

... More
Fixing of point machine on newly laid turnout on Wooden/MBC/Steel sleepers & fixing of ground connections. Adjustment and testing with crank handle operations. This will include fixing of bend pipes with welded frame for cable entry to machine. This will also includes necessary adjustment and smithy work, drilling of Holes to tongue rails, gauge plate & steel sleeper, fitting of 35 insulation for tongue attachment, gauge plate & William stretcher. This also includes cable entry to the point machine and termination of tail cable in point machine on ARA terminals and wiring of point machine (Necessary wiring modification for independent detection) using 2.5 sq mm insulated copper wire as per IS 696 of 1990 with suitable lugs. ARA terminals are to be suitably fixed on channels inside point machine .Supply& filling of SAE 30 lubricating oil (500ml approx). The work shall be done as per extant practice on W.C. Rly & the instruction of Rly engineer at site. Per Unit = Per Turnout

6

4676

28057.38

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian 36 paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per instructions of Rly engineer at site and extant practice on W.C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases also Termination particulars, equipment names etc. legibly and neatly inside location boxes etc.Appratus case full size

16

466

7471.68

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian 37 paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per instructions of Rly engineer at site and extant practice on W.C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases also Termination particulars, equipment names etc. legibly and neatly inside location boxes etc.Appratus case Half size

4

349

1397.08

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per instructions of Rly engineer at site and extant practice on W.C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases also Termination particulars, equipment names etc. legibly and neatly inside location boxes etc. Main Signal post with signal unit, surface base and complete fittings as per W.C.Rly. Standard practice.

-

-

38

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian 39 paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per instructions of Rly engineer at site and extant practice on W.C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases also Termination particulars, equipment names etc. legibly and neatly inside location boxes etc. Shunt Signal post with signal unit, surface base as per W.C. Rly.Standard practice.

2

189

378.12

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian 40 paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per instructions of Rly engineer at site and extant practice on W.C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases also Termination particulars, equipment names etc. legibly and neatly inside location boxes etc. Point machine with ground connection complete. Track lead junction box. ( Black enamel out side only)

50

92

4627

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per instructions 41 of Rly engineer at site and extant practice on W.C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases also Termination particulars, equipment names etc. legibly and neatly inside location boxes etc. Point machine with ground connection complete. ( Point machine with black enamel only out side and ground connection with red oxide)

6

163

983.94

... More
Lettering numbering of signals, point machine, track lead junction boxes, block joint, appratas cases etc ( each item to be taken as one unit )

20

60

1219.2

... More
Lettering numbering termination particulars, equipments names etc legibly and neatly inside location boxes. Single case

16

283

4529.44

... More
Lettering numbering termination particulars, equipments names etc legibly and neatly inside location boxes. Half case

4

160

641.76

... More
Dismantling and releasing of Colour light signal, Location Box. Which includes 49 dismantling of signal fittings complete & location box fitting complete. All dismantelled materials to be transported and stacked in the store of respective section or as nominated of JBP Div as per consignee.

10

1175

11752.9

... More
Supply and installation of earthing arrangement for axle counter DPs/signal location boxes. set consist of (i) SS angle of 3X30X200 mm grade 304(ii) SS wire rope of 1X19X12 mm dia SS 51 grade of 2.5 Mtr( Nominal) 316. (iii) SS nut bolt, Washer with check nut (iv) SS lug for crimping 2 nos. (v) Earthing compound as per RDSO specification no. RDSO/SPN/197/2008 Weight 25 KG. (vi) Precast RCC chamber with cover with pulling hook size approx. 300X300X50 mm thik.(Circular or rectangular section) SUPPLY PORTION INSPECTION BY CONSIGNEE

10

5783

57831.1

... More
All work pertaining to Horizontal Directional Drilling (HDD)/Boring and trenchless cabling in hard/rocky soil by machine. It includes supply. transportation and insertion of self 52 lubricated HDPE Pipe and laying of cables in boring under the track road plateform circulating area byusing self lubricated HDPE Pipe of 120mm outer dia and 103.5mm inner dia in the bore. The depth of horizontal boring should he minimum 2 mtrupto 3 mtr, from rail flange road level ground level as per site requirement and as per instructions of Railway Engineer incharge. Thickness 3.5 to 4.1 mm as per specification no. IS 4984:1995 with latest amendment, Material Grade PE 63

1200

1617

1941120

... More
Making of straight through joint for under ground cable jelly filled cable/6 Quad cable with joint ing kits supplied against supply item and construction of bricks chamber for protection of joints with all contractor materials.

4

789

3156.24

... More
Blowing and drawing of OFC through already buried HDPE duct , taking due care while transporting and sealing both the ends after blowing. The cable should be blown according to the technical instructions of the manufacturer and the instructions of the site in-charge.

1

14816

14816

... More
Transportation and Laying of HDPE pipe as per approved cable route plan in the 55 excavated trench, taking due care while transporting and laying the same in the trenches or other protective works. Both the ends of the duct should be sealed with end plugs before laying and should remain sealed till blowing is done.

1

6093

6093.04

... More
Splicing of 24 fibre OFC from both sides for straight through joint and testing. This includes excavation of pit & backfilling & supply of all type of material and any other equipment of all types.

6

5150

30903.48

... More
Splicing , Termination , Testing & Commissioning of 24 fibre cable in fibber management system with all installation material, connectors , fittings etc. As per instructions of site engineer. FMS with splicing materials supplied.

6

10064

60384

... More
Supply, Transportation & installation of prefab RCC OFC chamber (specification as per drawing enclosed) & filling with river sand & termite chemical after jointing work is done. (SUPPLY PORTION INSPECTION BY CONSIGNEE

4

7879

31516.28

... More
Supply of main LED signal UNIT 110V/AC as per RDSO specification No. RDSO/SPN/199/2010 Rev.1.0 or latest. Suitable for existing CLS housing unit . RED Aspect SUPPLY PORTION INSPECTION BY RDSO

5

8009

40046.15

... More
Supply of main LED signal UNIT 110V/AC as per RDSO specification No. RDSO/SPN/199/2010 Rev.1.0 or latest. Suitable for existing CLS housing unit . YELLOW Aspect SUPPLY PORTION INSPECTION BY RDSO

10

8508

85083.9

... More
Supply of main LED signal UNIT 110V/AC as per RDSO specification No. RDSO/SPN/199/2010 Rev.1.0 or latest. Suitable for existing CLS housing unit. GREEN Aspect SUPPLY PORTION INSPECTION BY RDSO

5

9586

47930.6

... More
Supply of Route LED Signal Lighting 110 V Ac in existing CLShousing and compatible with AC LED ECR as per RDSO Spec RDSO/SPN/153/2011 REV 4.1 OR LATEST SUPPLY PORTION INSPECTION BY RDSO

20

5728

114579.6

... More
Supply of Shunt LED Signal Lighting 110 V Ac in existing CLShousing and compatible with AC LED ECR as per RDSO Spec RDSO/SPN/153/2011 REV 4.1 OR LATEST SUPPLY PORTION INSPECTION BY RDSO

12

5614

67372.8



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.