West Central Railway Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

West Central Railway - WCR Tender

Works
Telecommunication Services
Ireps
Opening Date10 Jan 2025
Closing Date10 Feb 2025
Tender Amount₹ 1,71,50,803.4 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of flexible cable single core multistrend copper conductors, 1x2.5 sq.mm confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY CONSIGNEE

11

22272

245002.34

... More
Supply of Phenolic Laminated sheet, resin bonded 10mm thick, grade P3 in standard size of 1.22 x 1.22 Mtr as per spec. No IS 2036 of 1974 . INSPECTION BY CONSIGNEE

30

3409

102271.8

... More
Supply of B type choke to specn.Nos.IRS.S.65/83 with latest amendments. INSPECTION BY CONSIGNEE

54

856

46228.32

... More
Supply of adjustable Track Feed Resistance, 30 ohms as per RDSO Drg. Nos. SA- 20161-66M/M with latest amendments (with Phenolic moulded base). INSPECTION BY CONSIGNEE

62

2971

184248.5

... More
Supply of Track feed battery chargers of 10A rating to spec. nos. IRS:S.89/93 with latest amendment. Charger shall be suitable for charging 80 AH battery. INSPECTION BY RDSO

59

1051

62035.55

... More
Supply of PVC jacketed wire rope for Track Lead connections. PVC jacketed wirerope 09 should be of Galvanised steel wire rope 6 mm dia (6x19 stranded wire withsteel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1970. Reclaimed or recycled material should Nst be used. INSPECTION BY CONSIGNEE

639

56

36020.43

... More
Supply of clamp meter digital type with AC/DC clamp, three & three forth digit (3&3/4 digit) Make Metravi 4673, stanly SCM 222 or Equivalent INSPECTION BY CONSIGNEE

9

24682

222143.76

... More
Supply of Tag Blocks 200 way with cover as per IRS: S- 77/2006 (Rev. 1) with latest amendment. INSPECTION BY CONSIGNEE

40

1391

55678.4

... More
Supply of PVC Indoor Cable 1x60x0.6mm dia. Colour coding of insulation of inner core shall be in six colour viz Blue, Red, Green, Grey, Brown & Black .IRS:S-76/89 INSPECTION BY RDSO

1

195984

195984.85

... More
Supply of PVC Indoor Cable 1x 40x0.6mm dia. Colour coding of insulation of inner core shall be in four colour viz Yellow, white, pink & violet.IRS:S-76/89 INSPECTION BY RDSO

1

142663

142663.44

... More
Supply Relay Non AC Immune, Plug In type, DC Neutral Line 60 V , 4F/4B , 5F/3B , 14 6F/2B contacts, front and back contact metal to metal , confirming to IRS: S46 and firms specification. The relay housing shall contain two miniature identical relays in mini group housing complete with base plate Siemens make ( RSSK 30/0011) or functional equivalent. INSPECTION BY RDSO

100

11260

1126004

... More
Supply of Time Element Relay (Clock work type) AG timer of Siemens Make (Nos RSSK 30/0052) or functional equivalent with timer range up to 120 seconds. INSPECTION BY CONSIGNEE

35

11431

400089.2

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. With holder 1.6 A (System, Rapid or Malnad Make). INSPECTION BY CONSIGNEE

100

76

7645

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. With holder 0.6 A (System, Rapid or Malnad Make). INSPECTION BY CONSIGNEE

70

73

5133.8

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. Without holder 1.6 A (System, Rapid or Malnad Make). INSPECTION BY CONSIGNEE

100

22

2216

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. Without holder 0.6 A (System, Rapid or Malnad Make). INSPECTION BY CONSIGNEE

70

22

1551.2

... More
Supply of ARA Terminal Block made of PBT as per Drg No SA 23741 alt 3 & spec. No IRS S 75/91 with latest amendments with disconnecting links as per Drg no. RST/11336. INSPECTION BY RDSO

800

129

103880

... More
Supply of lamp holders and switches, two pin (Bakelite type) for location boxes (Anchor make or ISI mark) INSPECTION BY CONSIGNEE

30

79

2391.9

... More
Supply of Apparatus Case with miniature 'E' type locks with keys of ward no. 41 (E 22 type lock & key as per spec. No IRS S 30 & RDSO Drg.No. SA 3376/M & 3377/M respectively with latest Amendment) on both the doors, duly painted with red oxide. Half Case as per Drg No WS-8842/A with latest alteration.. INSPECTION BY CONSIGNEE

20

12553

251063.6

... More
Supply of GI pipes with collars (screwed and socket) as per spec. No. IS 1239 part-1 (2004 or latest), medium class, nominal bore of 100 mm, nominal mass of tube 12.5Kg ± 10% per meter and complying parameters of specification. INSPECTION BY CONSIGNEE

240

994

238783.2

... More
Supply of Concrete Cable Marker as per drawing SDO/Cable Laying/020 INSPECTION BY CONSIGNEE

1380

263

363547.2

... More
Supply of Heat shrinkable straight through joint for UG cables with all accessories as per RDSO spec. no."IRS /TC/77/2012 (rev-3) with amend.-1 &2 or latest for 6 quad cable 0.9mm dia (TSF-2)joint suitable for 6 quad cable. INSPECTION BY RDSO 26

26

2024

52632.06

... More
End Plug INSPECTION BY CONSIGNEE 27

-

-

26

... More
Cable Sealing Plug INSPECTION BY CONSIGNEE 28

11

55

611.27

... More
Plastic Coupler INSPECTION BY CONSIGNEE

59

55

3278.63

... More
Cabinet with wiring arrangement of DC-DC converter for 08 Nos. suitable for statcon make IPS (Material to be inspected by RDSO). INSPECTION BY RDSO

15

46151

692277.9

... More
Preparation of cable route plan ,cable corage plan ,location particulars,CTR particulars,maggering report,earth resistance particulars & any other drowing particular required in connection with IBS in AUTOCAD in A3 size. This includes plans for IBH and adjacent stations.The contractor shall initially two sets of documents for approval of Rlys.will return one set to the 01 contractor duly approved wwith alterations/correction,if any.The contractor shall incorporate Rlys.alterations/corrections/comments in the tracing and CD without any deviation and submit all tracings and final CD complete in all respects to the Rlys.along with 2 sets of printed documents.He shall insure that each sheet has a block for signature of Rly. officials as well as a block for signature of the firm duly signed by the autherised signatory of the firm.The name of the work as given by the Rly shall be written onevery sheet under the WORK column.(The contractor will design the corage plan based upon the I.P provided by railways and present for approval.)

5

19933

99669

... More
Design and supply of Detailed Signalling Circuits including panel diagram (if required), SWRD, Control table, Route section plan , Selection Table, Fuse & Negative Tag Analysis, Contact Analysis , Relay Rack Arrangement and wire count sheet etc. in A3 size, Completion circuit shall be plotted in Autocad. The contractor shall initially supply 2 Sets of circuits duly signed by the circuit designer having substantial experience on design side for making such circuits , complete for 02 approval of Railways. Railway will return one set of circuit to the contractor duly approved with alterations/ corrections, if any. The contractor shall incorporated Railway's alterations/corrections in the original tracings & CD without any deviation and submit two copies of the modified circuits. Original tracings so modified & final CD complete in all respects alongwith 4 sets of final approved circuits (out of which one set shall be supplied in transparent polythene bags. Only two sheets of cicuits shall be placed in one polythene bag/cover each) shall be submitted to the Railways in case there are no further alteration suggested by Railways. Complete sheets of circuit to be design for the station & to be submitted.

5

53911

269559.1

... More
Fixing of ARA /WAGO Terminals and fuse blocks with provision of holes on hylem sheets and fixing by galvanised nuts & bolts.This includes provision of two additional holes on the hylam board on either side for cable conductor entry. The work shall be done as per Engg. at site.

750

21

16432.5

... More
Termination of cable cores on ARA/ disconnecting type terminal, fuse blocks, 8 way 04 terminals block in the apparatus cases/point machine. This includes all associated works of pulling out the cable from underground, dressing of cable, making wiring tree etc. This includes soldering of armour tree/ring of cables and connecting to copper plate through GI wire bus bar in location boxes. The work shall be done as per location plans and instructions of Rly engineer at site.

2000

32840

32840

... More
All work pertaining to Horizontal Dirctional Drilling (HDD)/Boring and trenchless cabling in hard/rocky soil by machine. It includes supply. transportation and insertion of self lubricated HDPE 05 Pipe and laying of cables in boring under the track road plateform circulating area by using self lubricated HDPE Pipe of 120mm outer dia and 103.5mm inner dia in the bore. The depth of horizontal boring should he minimum 2 mtr upto 3 mtr, from rail flange road level ground level as per site requirement and as per instructions of Railway Engineer incharge. Thickness 3.5 to 4.1 mm as per specification no. IS 4984:1995 with latest amendment, Material Grade PE 63

250

3510

877695

... More
Excavation of trench as per cable route plan, 1.2 mtr deep, 300mm wide at the bottom along main line in normal soil, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by shahabad stone/bricks, clearing of route, 06 bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.

58.8

60208

3540259.8

... More
Excavation of trench as per cable route plan, 1 mtr deep, 300mm wide at the bottom along main line in hard soil / murrum, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by bricks.

4.71

86010

405107.1

... More
Excavation of cable trench 1m deep and 300mm wide across the track, for track crossing and refilling after laying of DWC/RCC/GI pipes. The work shall be done as per extant practice on W.C. Rly & instruction of Rly engineer at site.

234

137

32200.74

... More
Cutting of all types of Roads prepratory to trenching & excavation to depth of 1 Mtr X 300 mm wide approximately and refilling, after laying of RCC/GI/DWC pipe and to restore the road to original condition. The work shall be done as per extant practice

394

227

89796.54

... More
Preparation of Cable way 150 mm wide at the bottom and 300 mm deep in rocky area & refilling the same (after cable-laying) with concrete mixture of proportion 1:3:6 and grouting the ends at either side of the rocky portion using concrete mixture with Contractors own material.

1356

593

804365.64

... More
Supply & laying of well burnt bricks of size 225x100x75mm inside the trench (with the brick length being perpendicular to cable route) after laying of cable in station area from Outermost to Outermost signal or at any other location as per instruction of Engineer at site.

598686

3

2275006.8

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches. as per 12 approved cable route plan in the excavated trench, inside GI, DWC Pipes etc. taking due care while transporting and sealing both the ends after laying. The cables are to be laid as per extent practice of WCR and as per the instructions of engineer at site. This includes transportation of cable from the consignee depot to site or as per instruction of engineer incharge.

35.7

6562

234269.47

... More
Transportation & Laying of GI/DWC/RCC pipes along with collars in trenches at places wherever required as per the instruction of the engineer at site.

162

71

11508.48

... More
Splicing of 24 fibre OFC from both sides for straight through joint and testing. This includes excavation of pit & backfilling & supply of all type of material and any other equipment of all types.

31

5437

168568.39

... More
Supply, Transportation & installation of prefab RCC OFC chamber (specification as per drawing attached No RAILTEL/2002 /PFB/0487 enclosed) & filling with river sand & termite chemical after jointing work is done. SUPPLY PORTION INSPECTION BY CONSIGNEE

35

8318

291139.45

... More
Transportation and Laying of HDPE pipe as per approved cable route plan in the 16 excavated trench, taking due care while transporting and laying the same in the trenches or other protective works. Both the ends of the duct should be sealed with end plugs before laying and should remain sealed till blowing is done.

71.71

6432

461288.2

... More
Blowing and drawing of OFC through already buried HDPE duct , taking due care while 17 transporting and sealing both the ends after blowing. The cable should be blown according to the technical instructions of the manufacturer and the instructions of the site in-charge.manufacturer and the instructions of the site in-charge.

71.93

15641

1125121.15

... More
Cement concrete work in the ratio of 1:3:6 with contractors own as per instructions of site engineer.

6

3992

23957.22

... More
All Panel room works involving alteration, wiring and testing of control cum indication 19 panel, SPT, Group phones, test boards etc. in connection with Relay interlocking/IBS at existing station. This includes laying and termination of cable, if any from panel room to relay room in GI/HDPE pipe.

1

8634

8634.06

... More
Fixing of GI pipes for crossing the culverts, stone bridges etc. and concreting the ends with brick masonry at both ends as per the instructions of Rly. Engineer at site with Contractor's 20 materials. The brick masonry at the ends shall be done with well-burnt bricks & cement mixture of 1:3 ratios. (Supply of GI pipes is not covered in this item).This includes drilling of 3 nos. of 6 mm holes per meter on the periphery of GI pipe as per instruction of engineer at site. This also includes fixing of GI pipe with contractors own MS Chanel, clamps of proper size etc as per instructions of engineer at site.

360

88

31734

... More
Cutting of all types of platforms, trenching & excavation to depth of 300 mm x 300mm 21 wide approx. and refilling after laying of RCC/DWC/GI pipes and repairing the platform to restore to original condition. This also includes transportation and laying of RCC/DWC/GI pipes and to its restore the platform to its original condition. The work shall be done as per extant practice on W.C.Rly and as per instructions of Rly. Engineer at site.

450

227

102559.5

... More
Excavation, casting and plastering (above ground level) of Apparatus case foundation with contractors own Metal Sheet frame, cement, anchor bolts and other materials. Half case as per Drg No JBP/S&T/C/085

30

8766

262989.6

... More
Erection of apparatus cases.This includes filling of location foundation with river bed sand and plastering on top of the sand. Half case

30

789

23674.8

... More
Fabrication and fixing of phenolic board in location box by providing all fixtures as per 24 Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. Lasing and dressing of cables/wires terminated with contractors own supply of lasing thread. The work shall be done as per instructions of Rly engineer at site. Half Case.

30

1314

39427.8

... More
Installation of Eqpt. (Relays, resistance, chargers & batteries etc.) & wiring of the same in apparatus cases as per location & circuit diagrams with contractor's own PVC wires and wiring 25 material. The work shall be done as per instruction of Rly engineer at site and approval of wiring material ( from RDSO approved firms) being used and extant practice in W.C. Rly). Wiring of relays should be with 16/0.2mm wire and all other equipments wiring by 2.5 sq mm multi strand wire of IS 694 of 1990 or latest. Half Case.

30

958

28745.1

... More
Placing and securing of cable route marker in trenches at the specified interval and at diversion joint etc .along the cable route The work shall be done as per extant practice on WCR & the instruction of Rly engineer at site.

1380

15

20755.2

... More
Making of straight through joint for under ground cable jelly filled cable/6 Quad cable with joint ing kits supplied against supply item and construction of bricks chamber for protection of joints with all contractor materials.

21

833

17493.84

... More
Installation,wiring and testing of track device (double rail contact) including digging of trench, track crossing , laying of Double walled antirodent corrugated pipe or other pipe required for completed installation of system from track device to location box and making its terminations. Fixing 28 of deflector plates. (Double walled antirodent corrugated pipe made up of High Density Polyethylene of required dia and all other accessories as per site requirement to be supplied by the firm) & Installation of EJB / Track side Electronics inside the track side housing (if required) including supply of wires and other accessories. This includes installation including wiring of reset box as required for system.

36

13887

499944.24

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints Asian paints 29 / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per instructions of Rly engineer at site and extant practice on W.C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases also Termination particulars, equipment names etc. legibly and neatlyinside location boxes etc.

30

312

9371.7

... More
Lettering numbering termination particulars, equipments names etc legibly and neatly inside location boxes. a) Half case

30

143

4305

... More
Installation of cable termination panel rack, mounting of isolation transformers, termination of under ground jelly filled cables on the screw type terminals, supply of wiring material and wiring of circuitry as per instructions of engineer at site.

14

5114

71609.58

... More
Writing work of cable termination details of 6-quad, OFC, PIJF cables & equipments details at OFC Room/Cable hut & Station Building and wherever necessary as per direction of Engineer in-charge.

15

1220

18302.85

... More
Splicing , Termination , Testing & Commissionig of 24 fibre cable in fibber management system with all installation material, connectors , fittings etc. As per instructions of site engineer. FMS with splicing materials supplied.

35

10625

371875

... More
Supply connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40mm to earth electrode forand Installation & fixing of earth electrode assembly including earth wire signaling Equipment. Contractor will bring Earth enclosure and all other material required for provision of earthing. SUPPLY PORTION INSPECTION BY CONSIGNEE

30

3578

107362.5

... More
Supply & installation of SPD for digital axle counters specification of 5V SPD for axle counter. SUPPLY PORTION INSPECTION BY RDSO

20

5068

101378.2

... More
Supply & installation of SPD for 24 V SPD for power supply cum data ,line.for axle counter. SUPPLY PORTION INSPECTION BY RDSO

20

3335

66710.6



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.