West Central Railway Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

West Central Railway - WCR Tender

Works
Telecommunication Services
Ireps
Opening Date6 Jan 2025
Closing Date4 Feb 2025
Tender Amount₹ 2,03,83,084.54 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of end stop suitable for disconnect terminal block INSPECTION BY CONSIGNEE

2620

16

43858.8

... More
Supply of Earth Electrode assembly as per WCR Drawing S&T/CON/KOTA/Earthing/01. INSPECTION BY CONSIGNEE

38

1637

62232.22

... More
Supply of Apparatus cases with miniature E Type Locks with keys. (E Type Locks & keys as per spec. No IRS: S-30/64 & RDSO Drg. No. SA 3376/M & SA 3377/M with latest amendments). Single case as per Drg No. WCR/DY.CSTE(Con)/KOTA/3 with latest alteration. INSPECTION BY RITES

38

24955

948294.56

... More
Supply of cartridge fuse block made of PBT as per RDSO Drg.Nos. SA - 23748 Alt. 4 and Spec.Nos. IRS-S-75/2006 with INSPECTION BY RDSO

100

243

24369

... More
Supply of Non-deteriorating type low voltage cartridge fuse rate current 2 Amp / 4 Amp in equal proportion round head type as per specification Nos. IRS/S/78/92 with latest amendment. INSPECTION BY RDSO

100

105

10550

... More
Supply of PVC indoor cable 1x24x1 mm dia having colour coading of insulation of inner core shall be six colours viz. Blue, Red, Grey, Green, Brown & Black and shall be confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY RDSO

1

254095

254095.48

... More
Supply of PVC insulated railway signalling indoor single core [ tinned jumper wire] 1X 0 . 6 mm dia as per RDSO spec. Nos. IRS:S-76/89 with latest amendments of various colours INSPECTION BY CONSIGNEE

1

2907

2907.13

... More
Supply of PVC insulated flexible wire 16/ 0.2 mm dia as per RDSO spec. Nos. IRS:S- 76/89 with latest amendments of various colours INSPECTION BY CONSIGNEE

3

8159

24479.31

... More
Supply of Jumper wire 1X1mm dia as per RDSO spec, IRS:S-76/89 with latest amendments of various colours INSPECTION BY CONSIGNEE

5

8807

44038.15

... More
Supply of flexible cable single core multistrend copper conductors, 1x6 sq.mm confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY CONSIGNEE

1

83304

83304.13

... More
Supply of flexible cable single core multistrend copper conductors, 1x2.5 sq.mm confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY CONSIGNEE

1

22272

22272.93

... More
Supply of Handheld Digital Earth Clamp Tester for clamp on earth/ground resistance 15 measurement up to 1000 ohms. Accuracy 0.1 - 0.99: 1%, 1 -49: 1.5% Also measure current leakage up to 20A. No spines required for measurement. Model - CET 500 or equivalent / higher version make: Stanlay or equivalent. Inspection: INSPECTION BY RITES

28

89012

2492345.24

... More
Supply of Phenolic Laminated sheet, resin bonded 10mm thick, grade P3 in standard size of 1.22 x 1.22 Mtr as per spec. No IS 2036 of 1974 . Inspection by Consignee INSPECTION BY CONSIGNEE

122

4993

609205.78

... More
Supply of Cable route locator/tracer set suitable for Detecting underground armoured 18 optic fiber cable (OFC] and signaling cables with LCD Graphic. Display active/passive modes and depth range. 3m to 10m. Make- RD8200G or Rycom Pathfinder ST LOC10 GPS equivalent. INSPECTION BY RITES.

3

417182

1251547.2

... More
Supply of Electrically operated lifting barrier assembly as per RDSO spec. no. RDSO/SPN/208/2012 (Ver 2.0) with Amendment-1 or latest. Each consisting of 2 nos. electrically operated lifting barriers, 2 Pedestals, 2Nos. of 8 contract circuit controller with limit switch, hand cranks,2 electric motors 110 VAC 0.5 HP without centrifugal switch, 2 G.I Octagonal booms as per RDSO Drawing RDSO/S-11600 in 4 section of 8 feet long each, with 2 stop boards, boom light boxes, 19 MS. counter weights & 2 nos. of boom support for resting boom & boom resting assembly along with Gate Control Panel, indication panel on sheet metal fabricated box with switches and buttons to operate the gate as per Spec except (a) motor current is max. 5 Amps. for 0.5 HP motor & motor confirms as per spec (b) Wago terminal to be used instead of Elmex or M-5 terminals. (c) Circuit Controller should have CAM operated Siemens or Similar limit switches instead of wiping type contacts. Crank handle arrangement will be as per Rly. Requirement. The movement of the boom over 85 degrees to be restricted mechanically.. INSPECTION BY RDSO

1

408384

408384.76

... More
Supply of basic material to construct Unit Maintenance Free Earth consisting as per RDSO Spec No. RDSO/ SPN/ 197/2008 (or with latest Amend) consisting of : a) Copper bonded steel 21 electrodes of 3.0 m long, 17.2 mm dia with copper bonding thickness of min 250 micron and UL listed and marked - 1 No. b) Earth Enhancement compound of approved brand supplied in sealed bags of min 10 Kgs - 3 Nos. c) Copper Strip of 150 x 25 x 6mm to terminate Earth Rod - 2 No. d) Copper Strip of 300 x 25 x 6mm (MEEB) - 1 No. Procurement should be done by RDSO approved source. INSPECTION BY CONSIGNEE.

2

18729

37459.76

... More
Supply of Digital insulation and continuity tester as per technical specifications attached INSPECTION BY CONSIGNEE.

38

8761

332937

... More
Supply of digital multi meter digital type, three & three forth digit (3&3/4 digit) Make Stanlay SMM 606/Fluke 179/Metravi Metrasafe-20 or equivalent or better. NSPECTION BY RITES.

20

46203

924076.8

... More
Supply of GI pipe as per Specn. No. IS 1239 (Part-1)/1990 medium class normal bore of 100 mm, nominal mass of Tube 12.5 Kg (+/-) 10% per meter and complying parameters of specification. INSPECTION BY RITES.

720

1203

866656.8

... More
Termination of cable cores on ARA terminal/8-way/Fuse Block/Wago/Phoenix terminals on the cable termination rack. This includes all associated works of pulling out the cable from 01 underground, dressing of cable, making wiring tree with contractor lacing & threading material etc. This includes soldering of armour tree/ring of cables and connecting to Earth Bus bar. The work shall be done as per approved plan, extant practice on West Central Railways Railway & the instruction of Rly engineer at site. The termination of both ends of the cable core shall be counted as one No

200

13

2664

... More
Soldering of tag block, fixing and wiring of G type fuse, bus bar wiring per tag block as per approved plan, extant practice of WCR & as per instruction of site engineer (Solder wire, resin core, etc. material will be supplied by contractor) Unit- Tag block

67

210

14078.71

... More
Circuit wiring/Jumpering as per circuit diagrams in the relay rack /IDF rack tag block. Material required for jumpering will be provided by the contractor.

3200

15

48192

... More
Fixing of ARA /WAGO Terminals and fuse blocks with provision of holes on hylem sheets and fixing by galvanised nuts & bolts.This includes provision of two additional holes on the hylam board on either side for cable conductor entry. The work shall be done as per Engg. at site.

5300

24

127412

... More
Termination of cable cores on ARA/ disconnecting type terminal, fuse blocks, 8 way terminals block in the apparatus cases/point machine. This includes all associated works of pulling out the cable from underground, dressing of cable, making wiring tree etc. This includes soldering of armour tree/ring of cables and connecting to copper plate through GI wire bus bar in location boxes. The work shall be done as per location plans and instructions of Rly engineer at site.

-

-

9

... More
Excavation of trench as per cable route plan, 1.2 mtr deep, 300mm wide at the bottom along main line in normal soil, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by shahabad stone/bricks, clearing of route, 10 bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.

5.6

92718

519221.81

... More
Excavation of trench as per cable route plan, 1 mtr deep, 300mm wide at the bottom along main line in hard soil / murrum, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by bricks.

1.2

132451

158942.36

... More
Excavation of cable trench 1m deep and 300mm wide across the track, for track crossing and refilling after laying of DWC/RCC/GI pipes. The work shall be done as per extant practice on W.C. Rly & instruction of Rly engineer at site.

696

211

147503.28

... More
Cutting of all types of Roads prepratory to trenching & excavation to depth of 1 Mtr X 300 mm wide approximately and refilling, after laying of RCC/GI/DWC pipe and to restore the road to original condition. The work shall be done as per extant practice

684

351

240084

... More
Preparation of Cable way 150 mm wide at the bottom and 300 mm deep in rocky area & refilling the same (after cable-laying) with concrete mixture of proportion 1:3:6 and grouting the ends at either side of the rocky portion using concrete mixture with Contractors own material.

1420

913

1297738

... More
Supply & laying of well burnt bricks of size 225x100x75mm inside the trench (with the brick length being perpendicular to cable route) after laying of cable in station area from Outermost to Outermost signal or at any other location as per instruction of Engineer at site.

49000

6

322910

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches. as per 16 approved cable route plan in the excavated trench, inside GI, DWC Pipes etc. taking due care while transporting and sealing both the ends after laying. The cables are to be laid as per extent practice of WCR and as per the instructions of engineer at site. This includes transportation of cable from the consignee depot to site or as per instruction of engineer incharge.

65

10106

656903.65

... More
Transportation & Laying of GI/DWC/RCC pipes along with collars in trenches at places wherever required as per the instruction of the engineer at site.

1080

83

90212.4

... More
Transporting & Supply and installation of cable route indicator at interval of 50 mtrs. in trenches along the cable route as per specification. The work shall be done as per extant practice on WCR & the instruction of Rly engineer at site.

180

1236

222534

... More
Excavation, casting and plastering (above ground level) of Apparatus case foundation with contractors own Metal Sheet frame, cement, anchor bolts and other materials. Single case as per Drg No JBP/S&T/C/084

38

14331

544603.84

... More
Erection of apparatus cases. This includes filling of location foundation with river bed sand and plastering on top of the sand. Single case

38

1637

62231.84

... More
Fabrication and fixing of phenolic board in location box by providing all fixtures as per 21 Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. Lasing and dressing of cables/wires terminated with contractors own supply of lasing thread. The work shall be done as per instructions of Rly engineer at site. Single case

38

2315

87976.08

... More
Installation of Eqpt. (Relays, resistance, chargers & batteries etc.) & wiring of the same in apparatus cases as per location & circuit diagrams with contractor's own PVC wires and wiring material. The work shall be done as per instruction of Rly engineer at site and approval of wiring material ( from RDSO approved firms) being used and extant practice in W.C. Rly). Wiring of relays should be with 16/0.2mm wire and all other equipments wiring by 2.5 sq mm multi strand wire of IS 394 of 1990 or latest. Single case

-

-

22

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following 23 items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per WCR practice. Appratus case full size

38

663

25200.84

... More
Lettering numbering termination particulars, equipments names etc legibly and neatly inside location boxes. Single case.

38

402

15293.48

... More
Installation & fixing of earth electrode assembly including earth wire connected 25 through GI wire 8 SWG supported on M.S. flat of size 6mm x 40mm to earth electrode for signaling Equipment. Contractor will bring Earth enclosure and all other material required for provision of earthing.

40

3925

157035.6

... More
Dismantling and releasing of Colour light signal, Location Box. Which includes dismantling of signal fittings complete & location box fitting complete. All dismantelled materials to be transported and stacked in the store of consignee or any other store of JBP Div as per consignee.

28

1175

32908.12

... More
Dismantling and releasing of lifting barriers and its fitting etc. This includes complete removal & transport of lifting barrier and sliding boom. All dismantelled materials to be transported and stacked in the store of consignee or any other store of WC railway as per consignee.

14

3050

42710.5

... More
Installation, testing and commissioning of electrically operated lifting barrier, complete 28 with Casting of cement concrete foundation for pedestal and boom rest post, cabling power supply connection & wiring with complete outdoor work.The work shall be done as per approved plan, extant practice on W.C. Railway & the instructions of Rly. Engineer at site.Testing and commissioning is to be done by OEM Engineer.

1

13468

13468.13

... More
All work pertaining to Horizontal Dirctional Drilling (HDD)/Boring and trenchless cabling in hard/rocky soil by machine. It includes supply. transportation and insertion of self lubricated HDPE 29 Pipe and laying of cables in boring under the track road plateform circulating area by using self lubricated HDPE Pipe of 120mm outer dia and 103.5mm inner dia in the bore. The depth of horizontal boring should he minimum 2 mtr upto 3 mtr, from rail flange road level ground level as per site requirement and as per instructions of Railway Engineer incharge. Thickness 3.5 to 4.1 mm as per specification no. IS 4984:1995 with latest amendment, Material Grade PE 63

2110

900

1899000

... More
Preparation & submission of cable route plan of main & tail cables, cable corage plan, location particulars, CT rack particulars, meggering report, earth resistance particulars, traction bonding diagram and any other drawing / particular required in Auto CAD in minimum A3 size Each 31 sheet should have a block for signature of Railway Officials as well as block for signature of the firm, where signature shall be put up by the authorized signatory of the firm. The name of the work as given by the Railways shall be written on every sheet under the WORK column. One complete set of tracings and four sets of copies of complete above detailed particulars / drawings along with one CD to be supplied by the contractor in thick plastic folder. UNIT- PER station

2

26490

52981.5

... More
Excavation, casting and plastering (above ground level) of main signal foundation as per Drg.No.WCR/S&T/SIG/01 with contractor's own materials including cement and galvanised anchor bolts of standard size. The hole for cable entry should be kept as per site requirement and instruction of Rly engineer at site. The required scaffolding Ferma etc. for casting of foundation will have to be brought by the contractor at his own cost.

8

10131

81052.56

... More
Erection of CLS Post with Surface base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates and A/AG/C/P/G marker board 33 , protective screen, blanking of ladder (0.6mm MS sheet) if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. Wooden white cross- arms (1000x100 mm) to be provided by the contractor till the signals are commissioned with contractor's own material.

8

3860

30886.4

... More
Termination of tail cable on main & auxiliary signal units and wiring with contractor 34 own material, fixing of LED signal units etc. Flexible Single core copper wire 2.5 sq.mm (50/0.25) conforming to IS-694:1990 (as per aspect colour) and lugs etc. will be supplied by the contractor. This includes insertion of tail cables from ground to signal unit. The work shall be done as per instruction of Rly engineer at site.

8

1212

9699.92

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian 35 paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per instructions of Rly engineer at site and extant practice on W.C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases also Termination particulars, equipment names etc. legibly and neatly inside location boxes etc.Appratus case Half size

8

349

2794.16

... More
Installation of maintenance free earth includes:Digging/auguring/boring of single earth pit of 100 mm to 125 mmdiameter to the depth of approximately 2.8 meters. Insertion of three meters electrode and penetrating it atleast 0.2 meters by pushing gently with sledge hammer where the neutral soil is assumed. Filling of earth pit with earth enhancement compound (EEC) in slurry form and back filling. Carrying out exothermic weld connection of single earth electrode to a copper tape of 36 150 mm X 25 mm X 600 mm. Carrying out exothermal weld connection on the copper tape of 150 mm X 25 mm X 6 mm on earth electrode for connecting two 35 mm2 cable for redundancy. The exothermal welding material for bonding the earth system shall be procured from RDSO approved firms which includes graphite moulds, clamps, weld metal powder. 300 mm X 300 mm X 300 mm(inside dimension) concrete earth pit with a concrete lid approximately 50 mm thick with pulling hooks shall be provided to cover the pit. Back side of the cover will be painted in black and date of testing and average earth resistance value shall be written.

6

9116

54698.88

... More
Installation of Track device of SSDAC/MSDAC (Double rail contact of digital Axle counter) including digging of trench, track crossing, laying of double walled antirodent corrugated pipe from track device to location box /terminations, Fixing of deflector plates.(Double Walled 37 antirodent corrugated pipe made up of high density Polyethelene of required dia and all other accessories as per site requirement to be supplied by the firm).Casting of foundation for track side housing & erection of track side housing.Installation & Wiring & commissioniing of EJB, Reset box, track side electronic inside the track side housing including supply of wires and other accessories for complete instalation.INSPECTION BY CONSIGNEE

8

12963

103708.24

... More
Supply & installation of maintenance free earth consisting as per RDSO specification No. RDSO/SPN/197/2008 consisting of single earth pit which includes supply of 35 mm2/16 mm2/10 mm2 multistrand single core PVC insulated copper cable as per IS 694 for connecting main earth electrode to MEEB in the equipment room in duplicate as per manufacturers recommendations and as 38 per RDSO specifications as follow: (1) Copper bonded steel electrode of 3.0 meters long, 17 mm diameter with copper bonding thickness of minimum 250 microns and UL listed and marked: 1 No. (2) Earth enhancement compound of RDSO approved brand supplied in sealed bag of minimum 10 KG: 3 Nos. (3) Copper strip of 150mm X 25 mm X 6 mm to terminate earth rod: 1 No. (4) Copper strip of 300mm X 25 mm X 6 mm (MEEB): 1 No. (5) Copper strip of 150mm X 25 mm X 6 mm (MEEB): 1 No. SUPPLY PORTION INSPECTION BY CONSIGNEE

6

36242

217454.28

... More
Supply of Digital Axle CounterSingle section type to cater for 4 detection points. monitoring 3 track sections Suitable for working with straight and continuous track section on straight 01 line and suitable for IBS application. This item shall include Supply of final track clearance relay as well as resetrelays for each section with accessories like detection points.track side electronics. deflector plates housing for track side electronics etc. This should include supply of LV boxes and Reset Boxes at the adjacent stations as per requirement of IBS stem. The Axle countersystem should be as per RDSO specifications no. RDSO/SPN 177/2003 with latest amendmentand latest version for Digital Axlecounters & Manufacture's Specification and approved byRDSO/cross approved by RDSO. INSPECTION BY RDSO

2

1214393

2428786



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.