Urban Administration And Development Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Urban Administration And Development Tender
Electrical and Electronics
Eprocure
Opening Date31 May 2022
Closing Date14 Jun 2022
Tender AmountRefer Documents
Costs
EMD
₹ 22,543Document Cost
₹ 5,000Tender Fee
₹ 355
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_UAD_199842_2Tender No
2020206216Tender Authority
Urban Administration And Development ViewPurchaser Address
-Website
http://https://mptenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
3000014143-Same board switch & socket 16 Amp
Same board switch & socket 16
Amp./S.S. combined 20/16/6 Amp(AS PER PWD SOR - 2020)
9
-
-
3000014145- Short point
Point wiring (excluding metallic switch box & sheet) for 3 Pin 16
Amp.
socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper
multi strand conductor ISI marked in concealed rigid P.V.C. conduit
(HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch
&
socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC
insulated FRLS copper earth continuity conductor of green colour inside
conduit, screwless connector for joints as per specification for :-
Short point
5
-
-
3000014146-Medium point
Point wiring (excluding metallic switch box & sheet) for 3 Pin 16
Amp.
socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper
multi strand conductor ISI marked in concealed rigid P.V.C. conduit
(HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch
&
socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC
insulated FRLS copper earth continuity conductor of green colour inside
conduit, screwless connector for joints as per specification for :-
Medium point (AS PER PWD SOR - 2020)
5
-
-
3000014148-Long point
Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper
multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside
conduit, screwless connector for joints as per specification for :- Long point (AS PER PWD SOR - 2020)
15
-
-
3000014149- Extra long-I
Point wiring (excluding metallic switch box & sheet) for 3 Pin 16
Amp.
socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper
multi strand conductor ISI marked in concealed rigid P.V.C. conduit
(HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch
&
socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC
insulated FRLS copper earth continuity conductor of green colour inside
conduit, screwless connector for joints as per specification for :-
Extra long-I (AS PER PWD SOR - 2020)
15
-
-
3000014150-1.0 TR star rating 3 star
Split AC (non inverter) :- Supply installation testing and
commissioning of split type wall mounted air conditioning unit of
following capacity including indoor, outdoor unit fitted
with rotary compressor, copper condenser and first charge refrigerant
R410A. The condensing unit working range should be capable of providing
cooling between +/-5deg.C to 50 deg. C including connection of copper
pipe of required size upto 3 mtr., insulation, cordless
remote control, auto air swing louvers, wall stand for outdoor unit,
connection copper lead wire, condense water outlet pipe 2 mtr. complete
etc as required. Outdoor/indoor units should be of same make (brand).
1.0 TR star rating 3 star (AS PER PWD SOR - 2020)
6
-
-
3000014153-1.5 TR star rating 3 star
Split AC (non inverter) :- Supply installation testing and commissioning
of split type wall mounted air conditioning unit of following capacity
including indoor, outdoor unit fitted with rotary compressor, copper
condenser and first charge refrigerant R410A. The condensing
unit working range should be capable of providing cooling between +/-
5deg.C to 50 deg. C including connection of copper pipe of required size
upto 3 mtr., insulation, cordless emote control, auto air swing louvers,
wall stand for outdoor unit, connection copper lead
wire, condense water outlet pipe 2 mtr. complete etc as required.
Outdoor/indoor units should be of same make (brand). 1.5 TR star rating
3 star (AS PER PWD SOR - 2020)
8
-
-
3000014156-Telephone wire 0.5 mm, 4 Pair
Supplying and drawing following pair, 0.5 mm PVC insulated copper
conductor unarmoured telephone cable in existing surface/concealed,
steel/PVC conduit as required. Telephone wire 0.5 mm, 4 Pair (AS
PER PWD SOR - 2020)
200
-
-
3000014159-4 Pair un-shielded twisted pair (UTP) Supplying and drawing 4 pair un-shielded twisted pair (UTP), 0.5 mm PVC
insulated copper conductor un-armoured Cat-6 computer cable FRLS in
existing surface/concealed, steel/PVC. conduit/
casing-n-capping as required.(AS PER PWD SOR - 2020)
200
-
-
3000014160-30 minute backup, min. 6000 VAH
Supply, installation, testing and commissioning of UPS with isolation transformer & battery for backup, having three phase input with ground
(R-Y-B-N-G), Voltage range 190v AC-478v AC (based on load %), line low transformer (0-50% :190v/51-100% : 305v ± 3% VAC), line low comeback +25 - 35 VAC ( ± 3%), line high transfer 478 VAC (± 3%), line high comeback
461 VAC (± 3%), frequency range 46 - 54 Hz, power factor 0.99, Total harmonic distortion (current)-THDi (()5% with full load, having
output voltage 220 VAC/230 VAC/240 VAC, voltage regulation ± 1%, frequency 50
Hz ± 0.1 Hz, Synchronization range 46 -54 Hz, voltage distortion ≤2 % (linear load) & ≤5 % (nonlinear load), having pure sine wave
output waveform, crest factor 3 : 1, efficiency (AC -AC) 94%, power factor 0.9, having inbuilt isolation transformer, over load 101 - 109% : 5 Min, 110 - 129% : 1 Min, 130 - 150% : 10 sec, having SMF/VRLA battery type, transfer time line mode to battery mode 0 ms, inverter to bypass, ECO mode 0 ms, bypass to inverter 0 ms, ECO to inverter mode () 10 ms, when
bypass voltage of frequency is out of range, having features Eco mode, Fan speed control, EPO function, frequency converter mode &
parallel function (optional) up to 4 units. Operating temperature 0 - 45°C, noise level () 55 db @ 1 meter having display & indication features i.e. user friendly dot matrix LCD display, input : voltage & frequency, battery : voltage & level in %, internal DC bus voltage z frequency,
current, power& load level in %), UPS status (operating mode/warning/fault/codes
(fault & warnings), UPS settings (output voltage/ frequency/ bypass enable/disable/special function., UPS/CVCF/ECO. LED status (normal
mode/load on battery/load on bypass/system fault), Audible alarm (main failure alarm, low battery alarm, UPS warning, overload, fault &
bypass mode etc.), protections (advance electronic protection for device, safety backed with MCBs, fast acting fuses, high speed pulse blanking, electronic overvoltage/under voltage), connections (terminal block for input/bypass/battery & output), static bypass,
communication interface RS 232/USB port for software interface,
intelligent slot for SNMP (optional). UPS installation with all required
material arrangements as required as per IS specification. 7.5 KVA (3 phase input & 1 phase output) For 30 minute backup, min. 6000 VAH
(AS
PER PWD SOR - 2020)
1
-
-
3000014161- Projector and projector screen
Supply and installation of Projector and projector screen etc. (as per
specifications enclosed)
1
-
-
3000014162-Air Curtain
Supply and installation of Air Curtain (as per specifications enclosed)
MAKE- Almonard/Mitsubishi/Technocrats
3
-
-
4000000753-1.8 TR/2.0 TR single phase
Cassette AC :- Supply installation testing and commissioning of split
type ceiling cassette Slim line/floor standing air conditioning unit of
capacity including indoor, outdoor unit fitted with rotary compressor,
copper condenser and first charge refrigerant R410A/ecofriendly green
gas only, cordless remote control, auto air swing louvers, connection
copper lead wire between outdoor and indoor unit, connection copper
lead wire upto 1.5 mtr., excluding connection copper pipe of required
size, insulation, floor stand for outdoor unit, condense water outlet
complete etc as required. Outdoor/indoor units should be of same make
(brand).Ceiling suspended/mounted cassette type 4 way unit with inbuilt
drain pump & decorative
panels. 1.8 TR/2.0 TR single phase (AS PER PWD SOR - 2020)
2
-
-
4000000755-2.7/3.0 TR three phase
Cassette AC :- Supply installation testing and commissioning of split
type ceiling cassette Slim line/floor standing air conditioning unit of
capacity including indoor, outdoor unit fitted with rotary compressor,
copper condenser and first charge refrigerant R410A/ecofriendly green
gas only, cordless remote control, auto air swing louvers, connection
copper lead wire between outdoor and indoor unit, connection copper
lead wire upto 1.5 mtr., excluding connection copper pipe of required
size, insulation, floor stand for outdoor unit, condense water outlet
complete etc as required. Outdoor/indoor units should be of same make
(brand).Ceiling suspended/mounted cassette type 4 way unit with inbuilt
drain pump & decorative panels. 2.7/3.0 TR three phase (AS PER
PWD
SOR - 2020)
6
-
-
3000014172-Full comprehensive Maintenance for 3rd
Full comprehensive Maintenance for 3rd year
1
-
-
3000014173-Full comprehensive maintenance for 4th
Full comprehensive maintenance for 4th year
1
-
-
3000014174-Full comprehensive maintenance for 5th
Full comprehensive maintenance for 5th year