Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Urban Administration And Development Tender

Works
Electrical and Electronics
Eprocure
Opening Date31 May 2022
Closing Date14 Jun 2022
Tender AmountRefer Documents 
Notes
Download

Costs

  • EMD

    ₹ 22,543
  • Document Cost

    ₹ 5,000
  • Tender Fee

    ₹ 355

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
3000014143-Same board switch & socket 16 Amp Same board switch & socket 16 Amp./S.S. combined 20/16/6 Amp(AS PER PWD SOR - 2020)

9

-

-

... More
3000014145- Short point Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- Short point

5

-

-

... More
3000014146-Medium point Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- Medium point (AS PER PWD SOR - 2020)

5

-

-

... More
3000014148-Long point Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- Long point (AS PER PWD SOR - 2020)

15

-

-

... More
3000014149- Extra long-I Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- Extra long-I (AS PER PWD SOR - 2020)

15

-

-

... More
3000014150-1.0 TR star rating 3 star Split AC (non inverter) :- Supply installation testing and commissioning of split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A. The condensing unit working range should be capable of providing cooling between +/-5deg.C to 50 deg. C including connection of copper pipe of required size upto 3 mtr., insulation, cordless remote control, auto air swing louvers, wall stand for outdoor unit, connection copper lead wire, condense water outlet pipe 2 mtr. complete etc as required. Outdoor/indoor units should be of same make (brand). 1.0 TR star rating 3 star (AS PER PWD SOR - 2020)

6

-

-

... More
3000014153-1.5 TR star rating 3 star Split AC (non inverter) :- Supply installation testing and commissioning of split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A. The condensing unit working range should be capable of providing cooling between +/- 5deg.C to 50 deg. C including connection of copper pipe of required size upto 3 mtr., insulation, cordless emote control, auto air swing louvers, wall stand for outdoor unit, connection copper lead wire, condense water outlet pipe 2 mtr. complete etc as required. Outdoor/indoor units should be of same make (brand). 1.5 TR star rating 3 star (AS PER PWD SOR - 2020)

8

-

-

... More
3000014156-Telephone wire 0.5 mm, 4 Pair Supplying and drawing following pair, 0.5 mm PVC insulated copper conductor unarmoured telephone cable in existing surface/concealed, steel/PVC conduit as required. Telephone wire 0.5 mm, 4 Pair (AS PER PWD SOR - 2020)

200

-

-

... More
3000014159-4 Pair un-shielded twisted pair (UTP) Supplying and drawing 4 pair un-shielded twisted pair (UTP), 0.5 mm PVC insulated copper conductor un-armoured Cat-6 computer cable FRLS in existing surface/concealed, steel/PVC. conduit/ casing-n-capping as required.(AS PER PWD SOR - 2020)

200

-

-

... More
3000014160-30 minute backup, min. 6000 VAH Supply, installation, testing and commissioning of UPS with isolation transformer & battery for backup, having three phase input with ground (R-Y-B-N-G), Voltage range 190v AC-478v AC (based on load %), line low transformer (0-50% :190v/51-100% : 305v ± 3% VAC), line low comeback +25 - 35 VAC ( ± 3%), line high transfer 478 VAC (± 3%), line high comeback 461 VAC (± 3%), frequency range 46 - 54 Hz, power factor 0.99, Total harmonic distortion (current)-THDi (()5% with full load, having output voltage 220 VAC/230 VAC/240 VAC, voltage regulation ± 1%, frequency 50 Hz ± 0.1 Hz, Synchronization range 46 -54 Hz, voltage distortion ≤2 % (linear load) & ≤5 % (nonlinear load), having pure sine wave output waveform, crest factor 3 : 1, efficiency (AC -AC) 94%, power factor 0.9, having inbuilt isolation transformer, over load 101 - 109% : 5 Min, 110 - 129% : 1 Min, 130 - 150% : 10 sec, having SMF/VRLA battery type, transfer time line mode to battery mode 0 ms, inverter to bypass, ECO mode 0 ms, bypass to inverter 0 ms, ECO to inverter mode () 10 ms, when bypass voltage of frequency is out of range, having features Eco mode, Fan speed control, EPO function, frequency converter mode & parallel function (optional) up to 4 units. Operating temperature 0 - 45°C, noise level () 55 db @ 1 meter having display & indication features i.e. user friendly dot matrix LCD display, input : voltage & frequency, battery : voltage & level in %, internal DC bus voltage z frequency, current, power& load level in %), UPS status (operating mode/warning/fault/codes (fault & warnings), UPS settings (output voltage/ frequency/ bypass enable/disable/special function., UPS/CVCF/ECO. LED status (normal mode/load on battery/load on bypass/system fault), Audible alarm (main failure alarm, low battery alarm, UPS warning, overload, fault & bypass mode etc.), protections (advance electronic protection for device, safety backed with MCBs, fast acting fuses, high speed pulse blanking, electronic overvoltage/under voltage), connections (terminal block for input/bypass/battery & output), static bypass, communication interface RS 232/USB port for software interface, intelligent slot for SNMP (optional). UPS installation with all required material arrangements as required as per IS specification. 7.5 KVA (3 phase input & 1 phase output) For 30 minute backup, min. 6000 VAH (AS PER PWD SOR - 2020)

1

-

-

... More
3000014161- Projector and projector screen Supply and installation of Projector and projector screen etc. (as per specifications enclosed)

1

-

-

... More
3000014162-Air Curtain Supply and installation of Air Curtain (as per specifications enclosed) MAKE- Almonard/Mitsubishi/Technocrats

3

-

-

... More
4000000753-1.8 TR/2.0 TR single phase Cassette AC :- Supply installation testing and commissioning of split type ceiling cassette Slim line/floor standing air conditioning unit of capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A/ecofriendly green gas only, cordless remote control, auto air swing louvers, connection copper lead wire between outdoor and indoor unit, connection copper lead wire upto 1.5 mtr., excluding connection copper pipe of required size, insulation, floor stand for outdoor unit, condense water outlet complete etc as required. Outdoor/indoor units should be of same make (brand).Ceiling suspended/mounted cassette type 4 way unit with inbuilt drain pump & decorative panels. 1.8 TR/2.0 TR single phase (AS PER PWD SOR - 2020)

2

-

-

... More
4000000755-2.7/3.0 TR three phase Cassette AC :- Supply installation testing and commissioning of split type ceiling cassette Slim line/floor standing air conditioning unit of capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A/ecofriendly green gas only, cordless remote control, auto air swing louvers, connection copper lead wire between outdoor and indoor unit, connection copper lead wire upto 1.5 mtr., excluding connection copper pipe of required size, insulation, floor stand for outdoor unit, condense water outlet complete etc as required. Outdoor/indoor units should be of same make (brand).Ceiling suspended/mounted cassette type 4 way unit with inbuilt drain pump & decorative panels. 2.7/3.0 TR three phase (AS PER PWD SOR - 2020)

6

-

-

... More
3000014172-Full comprehensive Maintenance for 3rd Full comprehensive Maintenance for 3rd year

1

-

-

... More
3000014173-Full comprehensive maintenance for 4th Full comprehensive maintenance for 4th year

1

-

-

... More
3000014174-Full comprehensive maintenance for 5th Full comprehensive maintenance for 5th year

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.