South Eastern Coalfields Limited Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
South Eastern Coalfields Limited - SECL Tender
Civil And Construction
Building Construction
Eprocure
Opening Date26 Jul 2024
Closing Date16 Aug 2024
Tender Amount₹ 5,57,330
Costs
EMD
₹ 7,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_SECL_313488_1Bid Award Id
ViewTender No
SECL/SGP/EnM/eT/24-25/259 Dtd 25.07.2024Tender Authority
South Eastern Coalfields Limited ViewPurchaser Address
-Website
http://http://www.secl-cil.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreader s in existing cubicle panel board including drilling holes in cubicle panel, making connection etc. as required. 200A, 16KA details cost for each.
1
-
-
Wiring for light point / fan point /exhaust fan point /call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core in surface / recessed midium class PVC conduit with piano type switch, phenolic laminated sheet, suitable size MS. box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as reuired 1.8.1 Group A COST FOR 01 POINT
40
-
-
GROUP A ,Wiring for light / power plugwith 2x4 Sq mm FRLS PVC insulated copper conductor single core cable in surface / reccesed medium class PVC conduit alongwith 01 No. 4sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. COST FOR 50 METER
60
-
-
Supplying and fixing suitable size GI box with madular plate and cover in FRL Sonet on surface or in recess, including providing & fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A Modular switch connection etc, as required. COST FOR EACH.
20
-
-
Supplying and fixing suitable size GI box with madular plate and cover in front on surface or in recess, including providing & fixing 3 pin 5/6 A modular socket outlet and 5/6 A switch connection etc, as reqwiured.COST FOR EACH.
8
-
-
Wiring for circuit /submain wiring along with earth wire with following sizes of FRLS PVC insulated copper, conductor single core in surface / recessed medium class conduit as required. 4X4 sq mm + 2X4 sq mm earth wire
50
-
-
Earthing with copper earth plate 600mmX600mmX3mm thick including accessaries and providing masonary enclosure with cover having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salts required. details of cost for 30 meters.
2
-
-
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
2
-
-
Supply, installation, testing and commissioning of 1200mm sweep, BEE 5 star rated, ceilling fan with brushless direct current (BLDC) motor, class of insulation :B, 3 nos. blade, 30cm long down rod, 02 nos. conopies, shackel kit, safety rope, copper winding, power factor not less than 0.9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min, 350rpm (Talrance as per IS: 374-2019), THD less than 10% , remote or electronic regulator unit for speed control and all remaining accessaries including safety pin, nut bolts, washer temparature rese = 75 degree C (Max), insulation rasistance more than 2 mega ohm suitable for 230V, 50Hz, single phase AC safety earthing etc. complete as required.
8
-
-
LT 3 phase 5 Wire Aerial Bunched Cable of Size 3X35+1x16+1x25
0.15
-
-
Straight line Suspension Assembly (Suitable for all size cable)
3
-
-
Dead-end Assembly (Suitable for all size cable)
2
-
-
Piercing connector suitable for 95- 16 sqmm to 50-16 sqmm. cable for Distribution Box.
2
-
-
Part-B - Erection of metalic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size ) fondation including excavation and refilling etc. as required. Erection of pole above 8.0 metre and upto 11.0 metre
Details of cost for one No pole
6
-
-
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
18
-
-
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
6
-
-
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
5
-
-
Erection of cradle guard as required. Details of cost for one No
16
-
-
Earthing with copper earth plate 600mmX600mmX3mm thick including accessaries and providing masonary enclosure with cover having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salts required. details of cost for 30 meters.
6
-
-
Total impact of GST for the purpose of CTC
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements