Raja Ramanna Centre For Advanced Technology Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Raja Ramanna Centre For Advanced Technology - RRCAT Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date6 Mar 2024
Closing Date1 Apr 2024
Tender Amount₹ 43,00,000
Costs
EMD
₹ 86,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_RRCAT_799136_1Bid Award Id
ViewTender No
RRCAT/CSD/C/3121/W-4262/24/33Tender Authority
Raja Ramanna Centre For Advanced Technology ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Demolishing Reinforced cement concrete works by chiselling at all levels including scaffolding, cutting of reinforcement bars by gas cutting, straightening & stacking of steel bars and disposal of unserviceable materials within 50 metres lead etc. complete.
1
-
-
Earthwork excavation in foundations in all soils other than soft and hard rock by manual means upto a depth not exceeding 1.5 m. including shoring and dewatering, if necessary and refilling around foundations and in plinth with selected excavated earth, in layers not exceeding 250mm thick, consolidating etc., and disposing surplus earth within a distance of 50 metre lead. (Depth of excavation shall be measured from the existing average ground level.)
-
-
-
0.00 metre to 1.50 metre below average G.L
4
-
-
1.50 metre to 3.00 metre below average G.L
4
-
-
Earthwork excavation in foundations in soft rock by manual means upto a depth specified below including shoring and dewatering, if necessary and refilling around foundations and in plinth with selected excavated earth, in layers not exceeding 250mm thick, consolidating etc., and disposing of surplus earth within a distance of 50 metre lead as per drawings, specifications and as directed by the Engineer-in-Charge. (Depth of excavation shall be measured from the existing average ground level.)
-
-
-
0.00 metre to 1.50 metre below average G.L
4
-
-
1.50 metre to 3.00 metre below average G.L
4
-
-
Cement concrete 1:3:6 using graded stone aggregate 40 mm max. size including consolidating, finishing, curing etc. complete excluding formwork as per specifications.
1
-
-
REINFORCED CEMENT CONCRETE of M-25 grade at all levels using graded stone aggregate of 20mm max. size including machine mixing,, mechanical vibration, consolidation, finishing, curing etc. complete as per specifications but including shuttering, formwork and excluding steel reinforcement.
-
-
-
In foundations, footings, plinth beams & flooring.
5
-
-
In columns, mullions, pillars, posts, struts at all heights
5
-
-
In beams, slabs, lintels, bed blocks, chajjas, canopies, shelves, walls and window cills, Staircase etc. at all heights
11
-
-
Providing centering and shuttering using timber planks/steel plates including strutting and propping etc. at all heights and removal of the same for in situ reinforced concrete and in plain concrete work
-
-
-
Foundations, footings, base of columns plinth beams, flooring, machine foundations, bed blocks, window cills, copings and mass concrete
8
-
-
Columns, pillars, posts, struts, mullions etc. at all heights
54
-
-
Sides and soffits of beams, beam haunchings lintels, cantilever, girders, bressumers, soffits of suspended floors, roofs, balconies, chajjas etc. at all heights
78
-
-
Providing and placing in position REINFORCEMENT using TMT BARS of brand as specified in note no.(1) having minimum yield strength of grade Fe 500 confirming to IS 1786 for reinforced cement concrete work at all levels, including cutting, bending, fixing, tieing in position with 1.6 mm dia. soft drawn annealed binding wire, with chairs, legs, supports, rebaring of bars of 16# bars up to 300 mm depth in existing column with approved epoxy grout for bonding and welding with existing bars as per requirement etc. complete including cost of transporting the bars from factory to required location at work site, cost of 1.6mm dia soft drawn annealed binding wire, watch & ward, insurance etc complete all as per drawing , specifications and as directed by Engineer-in-charge.
2.5
-
-
Note : 1.The steel reinforcement bars shall be brought by the contractore at terms & conditions specified.Fe 500D grade TMT bars manufactured in the brand name of preferred make/brand shall be permitted subject to furnishing of challans,valid test report issued by the manufacturer ,pertaining to elongation,yield strength,Bend rebend test etc.
-
-
-
Note: 2. Binding wire required for the work will have to be supplied by the contractor at their own cost and will not be measured for payment.
-
-
-
Note : 3. The contractor shall be solely respossible all the time for watch & ward of bars/binding wires etc at their own cost.
-
-
-
Note : 4. The contractor shall supply copy of Documentary evidence of purchase of steel, test certificate from the firms and also testing from third party if required to be arranged at no extra cost.
-
-
-
Brick work in cement mortar 1:6 using table moulded chimney bricks having a compressive strength not less than 40kg/cm² in superstructure at all levels including double scaffolding, raking out joints, curing etc. complete as per specifications,
11
-
-
Sand faced plaster 20mm thick in 2 coats over exterior masonry and concrete surfaces at all heights with base coat in cement mortar 1:4, 12mm thick and finishing coat in cement mortar 1:3, 8mm thick final rendering, double scaffolding wherever necessary, hacking of concrete surfaces, curing etc. complete and addition of waterproofing compound @ 2% of weight of cement for the base coat etc. complete.
120
-
-
Providing, fabricating, cutting, erecting, and fixing in position structural steel works of any shape using RHS, SHS, foundation bolts & circular hollow sections of Grade Yst 250 as per IS: 4923 at all levels including welding, painting with a primary coat of approved steel primer and transportation etc. complete as per specifications and as directed by Engineer-in-Charge. (The welding weights shall not be measured for payments but cost of same shall be included in the rate.)
13.5
-
-
1. Structural steel conforming to IS: 2062
-
-
-
2. The contractor shall supply copy of Documentary evidence of purchase of steel, test certificates from the manufacturing firms and also testing from third party, if required to be arranged at no extra cost.
-
-
-
3. Welding weights, connections, bolts and nuts shall not be measured for payment but the cost of which shall be deemed to have been included in the rate.
-
-
-
4. All holes will be made by drilling only. Gas cutting of holes will not be permitted.
-
-
-
5. Electrodes manufactured by preferred only shall be used.
-
-
-
6. The contractor shall provide and erect necessary scaffolding system to carryout the work at requisit height as per drawing along with working plateform/ chadies.
-
-
-
7. The Contractor shall also provide safety net and safety equipment over entire work area for safety of work man carring out the work at height.
-
-
-
Providing, fabricating, cutting, erecting, and fixing in position structural steel works of any shape using Structural steel M.S. plain & chequered plates at all levels including welding, painting with a primary coat of approved steel primer and transportation etc. complete as per specifications and as directed by Engineer-in-Charge. (The welding weights shall not be measured for payments but cost of same shall be included in the rate.)
3
-
-
1. Structural steel conforming to IS: 2062
-
-
-
2. The contractor shall supply copy of Documentary evidence of purchase of steel, test certificates from the manufacturing firms and also testing from third party, if required to be arranged at no extra cost.
-
-
-
3. Welding weights, connections, bolts and nuts shall not be measured for payment but the cost of which shall be deemed to have been included in the rate.
-
-
-
4. All holes will be made by drilling only. Gas cutting of holes will not be permitted.
-
-
-
5. Electrodes manufactured by preferred only shall be used.
-
-
-
Providing and fixing 0.50 mm TCT color coated galvalume sheet AZ 150 ( 150 gm. Per sqm.) (Color Star Profile) sheets of preferred make, in roof of desired profile, facia including all overlaps metring,including profile ridge, supplying and fixing sheet using self drilling/self tapping screws of size (5.5x55 mm) with EPDM seal or with polymer coated 'J' hooks, bolts & nuts 8 mm dia. with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete including the cost of scaffolding, work at all heights etc. complete all as per drawing, specifications and as directed by Engineer-in-charge.
700
-
-
Providing and fixing Welded wire mesh (25 x 25 x 3mm) of best quality and approved make to existing frame, including cutting, making holes, etc. fixed in proper line and level etc. complete.
40
-
-
Painting the steel surfaces at all heights like windows, doors, structural steel members, frames, space frame with two coats of two component air drying acrylic aliphatic Polyurethane coatings of (Fosroc/BSAF/Asian/ Jenson Nicholson/Berger/ICI) of approved shade including applying one coat of Zinc Phosphate primer and preparing the surfaces by removing loose dust, rust and dirt with stiff brush and washing the surface with clean water, treating surface with anti-fungus chemical wherever required, filling with putty, scaffolding, tools & tackles, safety appliances etc. complete.
700
-
-
Painting the exterior walls and roof with two coats of Snowcryl XT acrylic emulsion/APEX Ultima of approved shade including preparing the surface by removing loose dust and dirt with stiff brush and washing the surface with clean water, treating the surface with antifungal chemical wherever required, filling holes with putty, scaffolding and cleaning, tools & tackles, safety appliances etc. complete as per specification.
150
-
-
Providing and fixing in position 2mm thick aluminum composite panels of required size over aluminum framework for ceiling, masking and cladding consisting of aluminum section of size 50x25x2 mm thick rectangle tubes for frames including cutting the members to required size, fixing by aluminum angle cleats of size 50x50x2mm thick to horizontal and vertical members placed @600mm and 1200mm respectively as per design requirement, fixing the aluminum frame secured to walls, ceiling and floor to existing framework . The frame members shall be cladded on single exposed side using 2.0mm thick prime quality aluminum composite panels manufactured by Durabuild, Alstone, Armstrong etc. Providing and fixing 5.5mm thick clear glass flush with surface. Using 3 M - VHB tape and sealent for fixing aluminum panels, glass, necessary filling up of gaps at junctions, top, bottom and all sides by glass sealent (No. 789 of Dow Corning or equivalent),
30
-
-
Imp. Note - a) The bidder must possess valid EPF & ESIC registration. The bidders need to deposit EPF & ESIC with appropriate authority. The reimbursement for EPF & ESIC deposit shall not be made. b) The payment of wages to labourers should be made through bank. c) The bidder must possess sufficient manpower & other resources (as detailed in SGF ) required for the timely completion of work. d) The minimum amount of bill to be paid shall be Rs. 5.00 lakhs.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements