Raja Ramanna Centre For Advanced Technology Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Raja Ramanna Centre For Advanced Technology - RRCAT Tender
Electrical and Electronics
Eprocure
Opening Date8 Feb 2024
Closing Date29 Feb 2024
Tender Amount₹ 89,70,000
Costs
EMD
₹ 1,79,400Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_RRCAT_794294_1Bid Award Id
ViewTender No
RRCAT/E/2024/W-4268/01Tender Authority
Raja Ramanna Centre For Advanced Technology ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Maintenance/Replacement of luminaire suitable for 150/250/400 watt MH/HPSV/160wat LED over High bay area (13 Mtr 17 Mtr height) and replacement of components viz. lamp/ballast / ignitor /Holder/LED luminaire etc. Replacing the components and testing of the luminaire including repairing in wiring etc., if needed. Refix the luminaire over pole with proper tightening of clamps and bolts. Test it again after fixing.
100
-
-
Maintenance/Replacement of luminaire suitable for 150/250/400 watt MH/HPSV/160wat LED over court yard area (13 Mtr 17 Mtr height) and replacement of components viz. lamp/ballast / ignitor /Holder/LED luminaire etc. Replacing the components and testing of the luminaire including repairing in wiring etc., if needed. Refix the luminaire over pole with proper tightening of clamps and bolts. Test it again after fixing.
100
-
-
Maintenance/Replacement of luminaire suitable for 150/250/400 watt MH/HPSV/ upto 160wat LED over parapet and replacement of components viz. lamp/ballast / ignitor /Holder/LED luminaire etc. Replacing the components and testing of the luminaire including repairing in wiring etc., if needed. Refix the luminaire over pole/roof/parapet wall etc.with proper tightening of clamps and bolts. Test it again after fixing.
230
-
-
Control Terminal box :-Replacement/Supply , installation , testing & commissioning of powder coated sheet steel enclosure (size-375x175x75mm) made out of 1.5mm GI sheet fitted with insulators SP-MCB and clamps this includes disconnection, reconnection use glands and lugs if required, dismantling of existing boxes and stacking within a RRCAT campus.
120
-
-
Repairing / Replacement of LED luminaire driver:
-
-
-
Replacement of LED driver from upto watt to 35 watt in exiting luminaire.
95
-
-
Replacement of LED driver from 36watt to 40 watt in exiting luminaire.
60
-
-
Replacement of LED driver from 41watt to 80 watt in exiting luminaire.
50
-
-
Replacement of LED driver from 81watt to 120 watt in exiting luminaire.
25
-
-
Replacement of LED driver from 121watt to 160 watt in exiting luminaire.
15
-
-
Replacement of LED driver from 161 watt to 320 watt in exiting luminaire.
20
-
-
Repairing / Replacement of LED luminaire PCB :
-
-
-
Replacement of PCB fitted upto to 35 watt.
50
-
-
Replacement of PCB fitted with 36 watt to 40 watt.
40
-
-
Replacement of PCB fitted with 41 watt to 80 watt.
10
-
-
Replacement of PCB fitted with 81 watt to 120 watt.
15
-
-
Replacement of PCB fitted with 121 watt to 160 watt.
10
-
-
Replacement of PCB fitted with 161 watt to 320 watt.
20
-
-
Driven rod:- Supply, installation and testing of 25 mm dia , 1.5 meter long driven rod for earthing including welding of 6mm X 25mm long M.S. bolt on existing pole and termination of 10 SWG G.I.wire as directed.
20
-
-
Attending/maintenance of the street light cable end termination box and replacement of existing MS clamps with new 15x5mm aluminium clamps (02 Nos) or components if required.
500
-
-
Excavation: Only excavation and backfilling of all types of soil soft /hard murrum/ boulders etc.
15
-
-
Power Cabling
-
-
-
Power Cabling :- (In Ground)
Only Installation, testing and commissioning of XLPE/PVC (FRLS) heavy duty power cable 1100V grade aluminium/copper conductor installed 900 mm below in ground by using over burnt bricks including excavation , sand cushioning, protective covering and refilling the trench compacting including watering , leveling the trench, removing the excess soil etc.
Size of cable - up to 3/4 core 35 sq.mm
1700
-
-
Power Cabling :- (On Wall/Trench)
Only Installation, testing and commissioning of XLPE/PVC(FRLS) heavy duty power cable 1100V grade aluminium/copper conductor installed on wall/trench. Size of cable - up to 3/4 core 35 sq.mm
700
-
-
Power Cabling :- (On Wall/Trench)
Only Installation, testing and commissioning of XLPE/PVC(FRLS) heavy duty power cable 1100V grade aluminium conductor installed on wall/trench. Size of cable - 3½ X 120/150/240 sqmm Al armoured XLPE cable.
100
-
-
Power Cabling :- (In Existing Hume pipe/GI pipe)
Only Installation, testing and commissioning of XLPE/PVC (FRLS) heavy duty power cable 1100V grade aluminium/copper conductor installed in existing hume/GI pipe. Size of cable - up to 3/4 core 35 sq.mm
200
-
-
Power Cable End Termination:- Supply , installation , testing & commissioning of end jointing for electrical aluminium armoured PVC/XLPE insulated (AYFY/A2XFY) cable 1100V grade by using double compression Nickle Plated Brass Gland and Aluminium lugs.
-
-
-
4 core 10 sq.mm
50
-
-
4 core 16 sq.mm
50
-
-
4core 25 sq.mm
60
-
-
3½ core 35/50 sq.mm
20
-
-
3½ core 120/150/240 sq.mm
10
-
-
SITC of straight through Joints by using push on termination kit
-
-
-
SITC of straight through Joints by using push on termination kit sizes of LT power cables - 4core X 6/10 Sqmm
10
-
-
SITC of straight through Joints by using push on termination kit sizes of LT power cables - 4core X 16/25 Sqmm
10
-
-
Preventive Maintenance including overhauling and rectification of faults if any of "Lighting High Masts" system having 12 Nos 2x400W Luminaires of metal halide on 07 nos high masts and 06 nos of LED high masts.
39
-
-
Supply and installation of 600mm long cable route marker made out of ISA(50x50x5mm) with masonary work and embossing LT cable on tag.
100
-
-
PCC WORK:-Cement concrete 1:4:8 using graded stone aggregate 40 mm maximum size including machine mixing,consolidating,finishing,curing etc complete including form work.
10
-
-
Structural steel work at all levels including supply, cutting, fabricating, welding including necessary scaffolding erecting & fixing in position, including painting with primer coat of approved steel primer MS pipe/clamps for street light pole or trench cover as per site requirement )
500
-
-
Supply, fabrication (by using CRCA sheet steel) and installation of sheet steel bus duct,cable trays,panel and MS boxes with complete chemical and mechanical process on MS sheet, powder coated, rubber gasket,locking arrangement,earthing bolt etc will be provided on the fabricated item as per requirement and specifications.
500
-
-
10 Watt LED endural bulk head IP:66, high effuciency luminaire.
50
-
-
Supply, installation, testing and commissioning/Replacement of 240 volts LED street light Luminaires having IP-65 protection with optical system,heat sink,driver in to one compact housing with lumen output ≥ 2500
50
-
-
Supply, installation, testing and commissioning/Replacement of 240 volts LED street light Luminaires having IP-65 protection with optical system,heat sink,driver into one compact housing with lumen output ≥ 4000
10
-
-
Supply, installation, testing and commissioning/Replacement of 240 volts LED street light Luminaires having IP-65 protection with optical system,heat sink,driver in to one compact housing with lumen output ≥ 11500
20
-
-
Suitable for outdoor surface mounting LED 70 watt, lumen output 7000 lumen, IP65, CRI70 in compact housing with driver. Scope shall include removal of existing luminaire with all accessories. and stored in within RRCAT campus.
30
-
-
Suitable for highbay surface mounting with all accessories, nominal wattage 100 to 105 Watt and lumen output 13000 lumen, IP65, CRI70. Removal of existing luminaire with all accessories. and stored in within RRCAT campus.
160
-
-
Suitable for outdoor installation of LED integral flood light with driver in one compact housing. Luminaire should have nominal efficacy ≥ 130 lm/watt, nominal output as 23400 lumen, Colour temperature : 5700K, CRI ≥ 70, IP/IK: 66/8, THDi: 10% at full load, 4 kV surge protection minimum, Optics: exposed lens optics policarbonate, Life Class: L70 @ 50K hrs. & complete with all accessories and driver. Removal of existing luminair with all accessories and storing within RRCAT campuss is also in the scope of this item.
60
-
-
Suitable for outdoor installation of LED integral flood light with driver in one compact housing. Luminaire should have nominal efficacy ≥ 120 lm/watt, nominal output as 42000 lumen, Colour temperature : 5700K, CRI ≥ 70, IP/IK: 66/8, THDi: 10% at full load, 4 kV surge protection minimum, Optics: exposed lens optics policarbonate, Life Class: L70 @ 50K hrs. & complete with all accessories and driver. Removal of existing luminair with all accessories and storing within RRCAT campuss is also in the scope of this item.
48
-
-
Supply, installation, testing and commissioning of 160A,three pole MCCBs fitted with thermal and magnetic release and having service breaking capacity- Ics ≥ 36KA
2
-
-
Supply, installation, testing and commissioning/Replacement of 3HP/2.2kW to 15HP/11 kW motor starter with enclosure.
6
-
-
Astonimical/Nature switch timer for street light control : Supply, installation, testing and commissioning of astronimical timer of rating single phase 16 ampere, 230 volts, 50 Hz, IP:54, manually settable with over voltage and under voltage protection.
50
-
-
Painting of Street light Poles : Painting steel work in two coats of Aluminium paint of approved shade and make over one coat of steel primer including preparing surfaces, scaffolding and cleaning, tools & tackles, safety appliances etc. complete.
250
-
-
Painting of Street light Foundtion : Painting the old exterior walls and roof with two coats of Snowcryl XT acrylic emulsion/APEX Ultima over one coat primer, of approved shade including preparing the surface by removing loose dust and dirt with stiff brush and washing the surface with clean water, treating the surface with antifungal chemical wherever required, filling with putty, scaffolding and cleaning etc. complete.
130
-
-
Hire charges for deploying hydraulic elevating/eccess plateform with (fitted onto SCV/LCV chassis) operator for works pertaining to trimming/pruning of tree branches and replacement of street light/coarts luminaires.
300
-
-
Hire charges for chain saw machine/brush cutter (non electric) with cost towards fuel/oil etc. with operator and helper for carrying out trimming/chopping of tree branches.
150
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements