Raja Ramanna Centre For Advanced Technology Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Raja Ramanna Centre For Advanced Technology - RRCAT Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date4 Mar 2024
Closing Date25 Mar 2024
Tender Amount₹ 48,00,000
Costs
EMD
₹ 96,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_RRCAT_797678_1Bid Award Id
ViewTender No
RRCAT/CSD/3113/W-4271/24-25/23Tender Authority
Raja Ramanna Centre For Advanced Technology ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
including maintaining the log book, giving daily feed back about the performance of pressurised fire line,valves,pumps etc in addition to all the activities /daily, weekly, monthly, quarterly, half yearly,yearly maintenance schedule enlisted in the detailed scope of work including carrying out repairs etc as & when required solely to ensure uninterrupted performance of the system etc all complete as per detailed specifications, standard operating procedures with total adherence to labour laws, contract conditions etc complete job as directed by Engineer in Charge BUT EXCLUDING supply & use of all such major items/ spares /sub systems/major repairs/servicing /painting covered in the scope of other item of this schedule which are payable under relevant item.
-
-
-
Note: 1) The payment shall be based on calendar month whether it is of 31 days or less than 31 days.
-
-
-
2) Contractor shall take all necessary measures including training if any, at his cost to assure uninterrupted performance.
-
-
-
3) Engineer in Charge shall have right to disallow any workmen to work without assigning any reason whatsoever.
-
-
-
4) The Contractor has to deploy 02 (two) nos. skilled person with 01(One) no. supervisor in general shift for any type of fire line maintenance work and 01 (one).no. skilled pump operator in each shift. on regular basis at Fire pump house located in technical area.
-
-
-
Supply & positioning of Control panel Battery 12 Volts 40 Ampere hour for uninterrupted functioning of Kirloskar make 231 hp Diesel Engine Pump set installed at the fire pumping stations including removing the existing battery and staking at division's stores, testing to show proper performance all as per detailed specifications, standard operating procedures with total adherence to labour laws, contract conditions etc and as directed by Engineer in Charge.
1
-
-
Supply & positioning of Spare parts for the Kirloskar make 231 hp Diesel Engine Pump set installed at the fire pumping stations including removing the existing component and staking at division's stores, testing to show proper performance all as per detailed specifications, standard operating procedures with total adherence to labour laws, contract conditions etc and as directed by Engineer in Charge.
-
-
-
Diesel Engine filter & Lubricating oil filter
2
-
-
Engine oil
50
-
-
V belt
1
-
-
Breather Tube
1
-
-
Coolant
50
-
-
Engine Starter (shelf)
1
-
-
Battery 12 V 180 Ah
1
-
-
Dunlop pad
1
-
-
Radiator belt set
1
-
-
Pump coupling
1
-
-
Bearing
1
-
-
12 V Battery Charger
1
-
-
Supply & positioning of Spare parts for the Kirloskar make two 20 hp Jockey Pump sets installed at the fire pumping stations including removing the existing component and staking at division's stores, testing to show proper performance all as per detailed specifications, standard operating procedures with total adherence to labour laws, contract conditions etc and as directed by Engineer in Charge.
-
-
-
Bronze Impeller
1
-
-
Shaft
1
-
-
Copper Motor Rewinding
1
-
-
Gland Plate
1
-
-
Contactor MNS 45
1
-
-
OLR 20-23
1
-
-
Attending break down maintenance on emergency basis by replacing, repairing & servicing of Kirloskar make 231 hp Diesel Engine Pump set installed at the fire pumping stations including supplying, replacing & removing the existing component and staking at division's stores including oiling greasing, replacement of accessories like Cylinder Liner assembly, Piston Assembly, Connecting Rod Bearing ,Lube oil Pump: high discharge, Water pump sub Assembly Valve pair inlet & exhaust, Valve guide, Valve seal, Valve seat insert inlet , Valve seat insert exhaust, Set of Joints, set of rings, Cylinder head gasket, Fuel pipes, leak off pipe assembly, Valve collets pair, Starter ring, connecting rod assembly & testing to show proper performance all as per detailed specifications, standard operating procedures with total adherence to labour laws, contract conditions including cost of material , labours and tolls etc. complete all as directed by Engineer-in-charge
1
-
-
Labour charges for qauterly routine inspection & general servicing of Kirloskar make 231 hp Diesel Engine Pump set, Kirloskar make 28 hp Diesel Engine Pump set & SAME GREAVES make 60 hp Diesel Engine Pump set, installed at the RRCAT pumping stations by kirloskar company certified mechanic/ Engineer including cost of tooles & tacles and testing to show proper performance all as per detailed specifications, standard operating procedures with total adherence to labour laws, contract conditions etc including oiling greasing complete as directed by Engineer-in-charge.
4
-
-
Supply & positioning of Spare parts for Zen Airtech make 5 hp Air Compressor set installed at the fire pumping stations including removing the existing component and staking at division's stores, testing to show proper performance all as per detailed specifications, standard operating procedures with total adherence to labour laws, contract conditions etc and as directed by Engineer in Charge.
-
-
-
Safety valve
2
-
-
V belt
1
-
-
Compressor oil
5
-
-
Air filter
2
-
-
Oil Filter
1
-
-
Fan Pulley
1
-
-
Bearings
1
-
-
Supply & positioning of Spare parts for 8000 Ltr Hydro Pneumatic Tank and accessories installed near fire pumping stations including removing the existing component and staking at division's stores testing to show proper performance all as per detailed specifications, standard operating procedures with total adherence to labour laws, contract conditions etc and as directed by Engineer in Charge.
-
-
-
Pressure gauge
1
-
-
Level Indicator
1
-
-
Level switch
1
-
-
Pressure Safety Valve
1
-
-
Compatible Solenoid valves
1
-
-
Supply & positioning of Spare parts for the fire line headers (suction and discharge), Check/Sluice/Butterfly valves/wheel valve, Strainers etc installed at the fire pumping stations including removing the existing component and staking at division's stores, testing to show proper performance all as per detailed specifications, standard operating procedures with total adherence to labour laws, contract conditions etc and as directed by Engineer in Charge.
-
-
-
Spindle or wheel of CI Gate/Sluice Valve- Φ250 mm
1
-
-
Spindle or wheel of CI Gate/Sluice Valve- Φ200 mm
1
-
-
Spindle or wheel of CI Gate/Sluice Valve- Φ150 mm
1
-
-
Spindle or wheel of CI Gate/Sluice Valve- Φ100 mm
1
-
-
Spindle or wheel of CI Gate/Sluice Valve- Φ80 mm
1
-
-
Bronze gate flap/Flap cover of size ranging from - Φ80 mm to Φ250 mm
1
-
-
S S Screens suitable for units of size ranging from - Φ80 mm to Φ250 mm
1
-
-
Fixing in position the departmentally supplied Sluice valve or wheel valve in the running or new pipe line including cutting of the existing or new pipe line, turning,machining,welding etc including providing & fixing EPDM gasket, distance piece with or without flanges or with pair of flanges complete with nut bolts including testing at working pressure of 10 kg per sq cm to show proper performance including removing the existing worn out valves and other components and staking at division's stores all as per detailed specifications, standard operating procedures with total adherence to labour laws, contract conditions etc and as directed by Engineer in Charge.
-
-
-
CI Gate/Sluice Valve- Φ250 mm with pair of flanges in distant piece
1
-
-
CI Gate/Sluice Valve- Φ200 mm with pair of flanges in distant piece
5
-
-
CI Gate/Sluice Valve- Φ150 mm with pair of flanges in distant piece
1
-
-
CI Gate/Sluice Valve- Φ 80 or Φ 100 mm with flanged distant piece
1
-
-
Repairing at scattered locations, flanged joint of specified diameter for DOUBLE FLANGED CAST IRON PRESSURE PIPES AND SPECIALS for fire water line by opening of defective joint together with one additional joint on either side of defective joint (if required), including re-aligning the disturbed pipes and providing all necessary jointing materials like Neoprene rubber gasket, mm threaded nuts, bolts, spring washers etc. complete and testing the joint for 16 kg/cm2 pressure with clean and potable water with a minimum testing duration of two hours as per drawings, specifications and as directed by Engineer-in-charge
-
-
-
100 mm nb
10
-
-
150 mm nb
20
-
-
200 mm nb
15
-
-
Repair, servicing and maintenance of BUTTER FLY VALVE of specified size including replacement of neoprene rubber gasket, mm threaded nuts, bolts, spring washers and greasing using Castrol or Servo grease @ 50 grammes to 100 gramme per valve etc. complete including testing the valves and joints for 16 kg/cm2 pressure with clean and potable water with a minimum testing duration of two hours etc. complete as per drawing, specifications and as directed by the Engineer-in-charge.
-
-
-
100 mm nb
1
-
-
150 mm nb
1
-
-
200 mm nb
1
-
-
Repair, servicing and maintenance of CAST IRON SLUICE VALVES of specified size including replacement of Neoprene rubber gasket, gland rope, nut bolts, washers and greasing to the spindle and sheet etc. using Castrol or Servo grease @ 100 gramme to 200 gramme per valve complete including testing the valves and joints for 16 kg/cm2 pressure with clean and potable water with a minimum testing duration of two hours etc. complete as per drawing, specifications and as directed by the Engineer-in-charge.
-
-
-
100 mm nb
30
-
-
150 mm nb
20
-
-
200 mm nb
15
-
-
Servicing and overall maintenance of LANDING VALVES of 65 mm dia including replacement of rubber gasket, Silicon/Nylone diaphragm washer, nut bolts, gland rope, diaphragm disc etc including greasing to the spindle and sheet @ 100 gramme per valve etc. complete to keep in good running condition as directed by the Engineer-in-charge. Note: The scope of this item does not include replacement of 25 mm dia & 175 mm long brass spindle.
354
-
-
Servicing and overall maintenance of LANDING VALVES of 65 mm dia including replacement of rubber gasket, Silicon/Nylone diaphragm washer, nut bolts, gland rope, diaphragm disc etc including providing & fixing new 25 mm dia & 175 mm long brass spindle including greasing to the spindle and sheet @ 100 gramme per valve etc. complete to keep in good running condition as directed by the Engineer-in-charge.
5
-
-
Servicing and maintenance of NON RETURN VALVE of 200 mm dia including replacement of rubber gasket, nut bolts, washers and greasing using Castrol or Servo grease @ 50 gramme per valve etc. complete to keep in good running condition as directed by the Engineer- in-charge.
2
-
-
Supply, installation and testing of 80 mm dia BUTTERFLY VALVE gear type of one of the reputed make like Normex,Marsh,Afcon,Omkar,Virgo,Maxflow,Challenger etc conforming to I S 13095 including making necessary joints, providing all jointing materials, greasing using Castrol or Servo grease @ 50 gramme per valve, testing the valves and joints for 16 kg/cm2 pressure with clean and potable water with a minimum testing duration of two hours etc. complete as per drawing, specifications and as directed by the Engineer-in-charge.
2
-
-
Repair ,servicing and maintenance of AIR RELEASE VALVE of 25 mm dia including replacement of balls, rubber gasket, nuts, bolts, washers etc. complete to keep in good running condition as directed by the Engineer- in-charge.
4
-
-
Polishing of 65 mm landing valves at scattered locations, using Brasso, Cotton waste, oil and greases etc to produce a shining surface including taking up the job after a general survey to identify valves where polishing is permitted by the department all complete as per specifications and as directed by Engineer in Charge.
472
-
-
Demolishing Reinforced cement concrete works by chiselling at all levels including scaffolding, cutting of reinforcement bars by gas cutting, straightening & stacking of steel bars and disposal of unserviceable materials within 50 metres lead etc. complete.
1
-
-
Labour only for fixing of water monitors on existing fire water line including transporting the monitors safely up to worksite, cutting of pipes/opening of blind flanges and providing all necessary jointing materials like Neoprene rubber gasket, mm threaded nut bolts, washers etc. complete and testing the joints for 10 kg/cm2 pressure with clean and potable water with a minimum testing duration of two hours etc. complete as per drawing, specification and as directed by the Engineer-in-charge.
1
-
-
Providing, laying, jointing, fixing and testing of expansion joint suitable for fixing in specified size of MS/CI line manufactured by fabrication using Class ‘C’ heavy variety M.S. non galvanized pipes of Preferred make as per I.S. 1239-1979 of dimensions as shown in drawing no. 1410/1 including providing & welding front & rear flanges having uniformly spaced eight nos 22 nb holes for providing & fixing large nut bolts including cutting the pipes at site for proper fixing, turning of expansion joint, as required for proper fixing complete as per the code of practice of water supply in building of IS: 2065-1972, including testing the pipes and fittings for 16 kg/cm2 pressure with a minimum period of 2 hrs. duration, including laying at all levels including cost of all hoisting mechanism, tools & tacles,painting 2 coats with synthetic enamel paint over a coat of primer on all exposed portion of expansion joint etc complete generally as per drawing, specifications and as directed by the Engineer-in-Charge.
-
-
-
a)Expansion joint suitable for fixing in 200 mm nb MS/CI line manufactured by fabrication as described above including two nos flanges as specified with lengthy nut bolts etc.
2
-
-
b)Expansion joint suitable for fixing in 150 mm nb MS/CI line manufactured by fabrication as described above including two nos flanges as specified with lengthy nut bolts etc.
2
-
-
c)Expansion joint suitable for fixing in 100 mm nb MS/CI line manufactured by fabrication as described above including two nos flanges as specified with lengthy nut bolts etc.
1
-
-
Providing, laying, jointing, fixing and testing of double flanged distance pieces of total length ranging from 80 mm to 100 mm as per site conditions suitable for fixing in 150 mm nb MS/CI line manufactured by fabrication using Class ‘C’ heavy variety M.S. non galvanized pipes of Preferred make as per I.S. 1239-1979 including providing & welding front & rear flanges having uniformly spaced eight nos 22 nb holes for providing & fixing large nut bolts including turning of old/new pipes as required for proper fixing of butter fly valves or other fitments complete as per the code of practice of water supply in building of IS: 2065-1972, including testing the pipes and fittings for 16 kg/cm2 pressure with a minimum period of 2 hrs. duration, including laying at all levels including cost of all hoisting mechanism, tools & tacles,painting 2 coats with synthetic enamel paint over a coat of primer on all exposed portion of distance piece with double flanges etc complete as per drawing, specifications and as directed by the Engineer-in-Charge.
4
-
-
Providing, laying, jointing, fixing and testing of double flanged distance pieces of total length ranging from 80 mm to 100 mm as per site conditions suitable for fixing in 200 mm nb MS/CI line manufactured by fabrication using Class ‘C’ heavy variety M.S. non galvanized pipes of Preferred make as per I.S. 1239-1979 including providing & welding front & rear flanges having uniformly spaced eight nos 22 nb holes for providing & fixing large nut bolts including turning of old/new pipes as required for proper fixing of butter fly valves or other fitments complete as per the code of practice of water supply in building of IS: 2065-1972, including testing the pipes and fittings for 16 kg/cm2 pressure with a minimum period of 2 hrs. duration, including laying at all levels including cost of all hoisting mechanism, tools & tacles,painting 2 coats with synthetic enamel paint over a coat of primer on all exposed portion of distance piece with double flanges etc complete as per drawing, specifications and as directed by the Engineer-in-Charge.
4
-
-
Providing, laying, jointing, fixing and testing of blind flanges of following sizes suitable for fixing in MS/CI manufactured by fabrication using specified thickness of M S plate including making holes for providing & fixing large nut bolts, 3 mm thick neoprene gasket, all complete as per the code of practice of water supply in building of IS: 2065-1972, including testing the pipes and fittings for 16 kg/cm2 pressure with a minimum period of 2 hrs. duration, including laying at all levels including cost of all hoisting mechanism, tools & tacles,removal of old worn out flange or other fitment, painting 2 coats with synthetic enamel paint over a coat of primer on all exposed portion of flanges etc complete as per drawing, specifications and as directed by the Engineer-in-Charge.
-
-
-
16 mm thick, 200 mm dia blind flange for fixing in 80 mm n b pipe with gasket and 8 nos large nut bolts of 16 mm dia in machine made suitable holes.
2
-
-
16 mm thick, 220 mm dia blind flange for fixing in 100 mm n b pipe with gasket and 8 nos large nut bolts of 18 mm dia in machine made suitable holes.
2
-
-
20 mm thick, 280 mm dia blind flange for fixing in 150 mm n b pipe with gasket and 10 nos large nut bolts of 18 mm dia in machine made suitable holes.
2
-
-
22 mm thick, 350 mm dia blind flange for fixing in 200 mm n b pipe with gasket and 12 nos large nut bolts of 20 mm dia in machine made suitable holes.
2
-
-
32 mm thick, 550 mm dia blind flange for fixing in 350 mm n b pipe with gasket and 16 nos large nut bolts of 25 mm dia in machine made suitable holes.
2
-
-
Collecting fire water samples as directed, from fire hydrants or fire sumps at scattered locations in RRCAT, carefully in containers disinfected as per I S 1622-1987 for arranging testing on specified parameters as per IS 3025 part 1 to 60 to ascertain suitability of water for intended use, complete as per following notes and as directed by the Engineer-in- Charge.
1
-
-
Repainting of old painted surfaces with two coats of Enamel PU paint of Preferred make of approved post office red color/black flat oil paint on all fire pipe line headers /valve /h.p.tank /Diesel tank/pumps/Air compressor /supports etc within pumping station premises including preparing the surfaces, removal of old paint, if any, sand papering, filling with putty as required complete as per specifications and as directed by Engineer in Charge.
50
-
-
Earthwork excavation in foundations in all soils other than soft and hard rock up to a depth specified below, including shoring and dewatering, if necessary, and refilling around foundations and plinth with selected excavated earth, in layers not exceeding 250mm thick, watering, consolidating etc., and disposing of surplus earth within a distance of 50 metre as per drawings, specifications and as directed by the Engineer-in-charge (depth of excavation shall be measured from the existing average ground level after over area excavation).
-
-
-
0.00 metre to 1.50 metre below average G.L
5
-
-
Excavation in trenches for pipes & sewers in all soils except soft & hard rock up to a depth of 1.50m including shoring & dewatering and refilling in trenches with selected excavated materials in layers not exceeding 250mm, consolidation and disposing surplus material within a distance of 50m etc. complete as directed by Engineer-in-Charge.
5
-
-
Lead charges by mechanical transport for lead exceeding 2 Kms but not exceeding 3 Kms including loading, unloading, stacking, levelling etc.
-
-
-
All soils
10
-
-
Demolishing brick work in cement mortar including scaffolding, stacking of serviceable material and disposal of unserviceable material within 50 mtr. lead as per drawings, specifications and as directed by the Engineer-in-Charge.
2
-
-
DEMOLISHING PLAIN CEMENT CONCRETE WORKS BY CHISELLING at all levels including scaffolding, disposal of materials within 50 m lead as per drawings, specifications and as directed by Engineer-in-charge.
2
-
-
Demolishing brick work in cement mortar at all levels including scaffolding, stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead etc. complete.
1
-
-
Plain cement concrete 1:3:6 using graded stone aggregate 40 mm max. size including hand mixing,consolidating, finishing, curing ,etc complete but excluding formwork and as per drawings, specifications and as directed by the Engineer-in-charge.
2
-
-
REINFORCED cement concrete at all levels in M-20 grade using graded stone aggregate of 20 mm max. size including machine mixing, consolidation, finishing, curing, etc., complete at all height as per drawings, specifications and as directed by Engineer-in-charge but excluding shuttering, formwork and steel reinforcement.
-
-
-
In foundations, footings, plinth beams, base of columns, flooring.
2
-
-
Providing and placing in position REINFORCEMENT using TMT BARS of Preferred make having minimum yield strength of Fe 500 conforming to IS 1786, for reinforced cement concrete work at all levels, including cutting, bending, fixing, tying in position with 1.6 mm dia. soft drawn annealed binding wire, with chairs, legs, supports etc. complete including cost of transporting the bars from factory to required location at work site, cost of 1.6 mm dia. soft drawn annealed binding wire, watch & ward, insurance etc complete all as per drawing, specifications and as directed by Engineer-in-charge. (The contractor has to submit the test report & Challan of the reinforcement, procured by him.)
0.1
-
-
NOTE: Binding wire required for the work will have to be supplied by the contractor at their own cost and will not be measured for payment.
-
-
-
Providing centering and shuttering at all heights using timber planks/steel plates including strutting and propping etc. and removal of the same for in situ reinforced concrete and in plain concrete work as per drawings, specifications and as directed by Engineer-in-charge.
-
-
-
Foundations, footings, base of columns, plinth beams, flooring, machine foundations, bed blocks, windows cills, copings and mass concrete.
3
-
-
Providing, fabricating, cutting, erecting, and fixing in position structural steel works of any shape using ISMBs, Joists, channels, angles, flats, Tees etc. of minimum grade Fe 250, at all levels including welding, two coat painting with a primary coat of approved steel primer and transportation etc. complete as per specifications and as directed by Engineer-in-Charge. (The welding weights shall not be measured for payments but cost of same shall be included in the rate.)
0.25
-
-
Note: Only standard weight as per I S tables or actual weight of prefabricated sections whichever is less shall be considered for payment and welding weight shall not be considered for payment.
-
-
-
Providing & fixing in position Two piece/three piece full bore gear operated cast steel Ball Valves with flanged ends conforming to BS: 5351/ANSI B16.34, grade WCB, making necessary flanged joints, providing all jointing materials, testing the valves & joints and joints for 16 kg/cm2 pressure with clean and potable water with a minimum testing duration of two hours including cost of removing of old existing valve etc. complete as per drawing, specifications and as directed by the Engineer-in-charge.
-
-
-
80mm n.b.
1
-
-
100mm n.b.
1
-
-
150mm n.b.
4
-
-
Making LEAD CAULKED JOINTS to cast iron socket and spigot or double socket pressure pipes and specials for water supply including cost of lead, spun(jute)yarn, fuel, labour, including making socket pits for lead pouring and caulking and testing the joints with clean and potable water for 10kg/cm2 pressure with a minimum testing duration of two hours as per specification and as directed by the Engineer-In-Charge.
-
-
-
150mm dia
5
-
-
100mm dia
5
-
-
80mm dia
5
-
-
Providing , laying and jointing cast iron specials/fittings for pressure pipes for water supply like tees, bends , collars, reducers, enlargers of all sockets, socket and spigot or double end flanged conforming to IS -1538 (Part I to XXIII)-1976 to correct alignment and levels including testing the specials to 10kg/cm2 pressure with minimum period of testing of two hours clean and potable water, complete as per drawing and specifications and as directed by Engineer-In-Charge.
50
-
-
Providing & fixing best Indian make C.I.GATE VALVE with flanged ends conforming to IS 780, along with a pair of C.I.tail pieces conforming to IS-1538, making necessary flanged joints, providing all jointing materials, testing the valves and joints for 10kg/cm2 pressure with clean and potable water with a minimum testing duration of two hours etc.,as per specification and as directed by the Engineer-In-Charge.
-
-
-
80 mm dia
3
-
-
100 mm dia
3
-
-
150 mm dia
3
-
-
200 mm dia
3
-
-
Providing , jointing and fixing HEAVY QUALITY G.I. FLANGES in pair for m.s. galvanized pipes conforming to I.S.: 778 including bolts, nuts, rubber insertion , including testing the joints for 16kg/cm2 pressure with clean and potable water with a minimum period of two hours duration & removing of old damaged flanges etc. ,as per specification and as directed by the Engineer-In-Charge.
-
-
-
80 mm dia
3
-
-
100 mm dia
4
-
-
150 mm dia
5
-
-
200 mm dia
5
-
-
Providing, laying, jointing & fixing in position Mild Steel ERW pipes ’ conforming to IS: 1239 having minimum specified thickness manufactured by Preferred make , Electrodes including providing & fixing all required M.S. fittings & specials of grade ‘C’, cost of transportation to site, welding, testing at a pressure of 24 kg per sq cm for 30 minutes duration and a coat of approved epoxy primer etc. complete as per drawing, specifications and as directed by Engineer-in-charge.
-
-
-
150 mm (5.40 mm Minimum thickness)
95
-
-
100 mm (5.40 mm Minimum thickness)
20
-
-
80 mm (4.80 mm Minimum thickness)
15
-
-
Providing and laying in trenches socket and spigot centrifugally cast (SPUN) DUCTILE IRON PRESSURE PIPES FOR WATER SUPPLY CLASS K-9, PN 10, conforming to IS: 8329, externally bituminous painted over zinc coating and internally cement lined, including lowering and keeping them in position to correct alignment and levelling, including cutting to waste of pipes wherever necessary, testing the pipes after making necessary joints (joints measured and paid for separately) to 10kg/cm² pressure with minimum duration of testing for two hours with clean and potable water etc. complete.
-
-
-
100mm n.b.
5
-
-
150mm n.b.
5
-
-
200mm n.b.
5
-
-
Note: The measurement shall be taken along the centre line of pipes in between the fittings or specials.
-
-
-
Providing, fixing and laying Ductile Iron fittngs and specials of class K12 suitable for push on jointing externally and internally coated and testing the same as per IS 9523 etc complete as per specifications and as directed by engineer-in charge.
100
-
-
Providing and fixing in position rising spindle type preferred make gate valve for presure rating PN 1.6 confirming to IS: 14846/BS5163 with flanged ends confirming to IS 1538, fixing to existing flanged ends , providing all jointing materials ,neoprene gaskets, nuts, bolts, washers & removing of old existing valve etc. testing the valves and joints for 16Kg/cm2 pressure with clean and potable water with a minimum testing duration of 2 hrs etc. complete as per drawing, specifications and as directed by Engineer-in- charge.
-
-
-
200 mm
4
-
-
150 mm
4
-
-
100 mm
4
-
-
80 mm
4
-
-
Providing and fixing Gun metal Landing Valve consisting of stop valve and check nut valve, spindle,hand wheel, instantaneous female outlet fixed at 90 degree off to vertical axis of valve with blank cap fixed to outlet etc. confirming to IS 5290 including testing at 10 Kg/sqcm. for a period of 2 hours with clean water including making necessary flange joints with rubber insertion, bolts and nuts, painted with two coats of paint of approved shade over a coat of primer & remving of old damaged existing Landing Valve etc. complete all as per specification, drawings and as directed by Engineer in charge.
5
-
-
Supply and erection of 20/25 mm GM air release cock, with necessary GI coupling to be fitted on top of Air vessel or on wet riser including removing of old existing air release cock all as per drawings, specifications and as directed by Engineer in Charge.
4
-
-
Welding of M.S. Pipe line or any other member of any size any-where in RRCAT premises at all heights including scraping of existing worn out joint welding of joints using approved electrodes to achieve 3mm weld thickness of required weld length including removing flux, debris etc., painting one coat of steel primer touch up, grinding of joint before painting including safe removing & refixing of glass if necessary etc. complete as per drawing, specifications and as directed by Engineer-in-charge.
700
-
-
Supplying & Installation of best Indian make Pressure gauge for fire line including making joints, supplying all jointing materials including providing & fixing 3/8 " S S ball valve, 3/8 " brass,elblow nipple,bush & remving of old / damaged existing Pressure gauge etc complete including testing the pressure gauge & joints to 16 kg per Sq cm pressure with clean & potable water with minimum testing period of two hours duration, all as complete as per drawing and specifications and as directed by Engineer-In-Charge.
10
-
-
Repainting of old painted surfaces of C I /M S water line of specified diameter with two coats of compatible synthetic enamel/flat oil paint of approved shade & preferred make including preparing the surfaces, including removal of old paint, if any, sand papering, filling hair cracks with putty and other cracks with 'Roffe' repair mortar, primer as required, scaffolding & cleaning, cost of all materials, labour, all complete as per drawing, specifications and as directed by Engineer-in-charge.
-
-
-
100 mm dia
120
-
-
150 mm dia
160
-
-
200 mm dia
310
-
-