Raja Ramanna Centre For Advanced Technology Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Raja Ramanna Centre For Advanced Technology - RRCAT Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date29 Jan 2024
Closing Date19 Feb 2024
Tender Amount₹ 23,07,000
Costs
EMD
₹ 46,140Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_RRCAT_792495_1Bid Award Id
ViewTender No
RRCAT/CSD/88/3126/W-4269Tender Authority
Raja Ramanna Centre For Advanced Technology ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Demolishing plain cement concrete works by chiselling at all levels including scaffolding, disposal of materials within 50 metres lead etc. complete as per drawings, specifications and as directed by EIC.
3
-
-
Demolishing Reinforced cement concrete works by chiselling at all levels including scaffolding, cutting of reinforcement bars by gas cutting, straightening & stacking of steel bars and disposal of unserviceable materials within 50 metres lead etc. complete as per drawings, specifications and as directed by EIC.
3
-
-
Dismantling the existing structural steel work at all levels in M.S. channels, plates, angles, flats, R.S. joists, bolts etc. including scaffolding, cutting of structural steel members by gas cutting, removing the nuts, bolts etc. complete and shifting the dismantled material by mechanical transport to departmental stores etc. complete as per drawings, specifications and as directed by EIC.
0.1
-
-
Demolishing brick work in cement mortar at all levels including scaffolding, stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead etc. complete as per drawings, specifications and as directed by EIC.
2
-
-
Lead charges, by mechanical transport to anywhere in RRCAT CAMPUS, including loading, unloading, stacking/levelling etc. complete as per drawings, specifications and as directed by EIC.
-
-
-
For soil
25
-
-
for debris up to 3.0 km
10
-
-
Cement concrete 1:3:6 using graded stone aggregate 40 mm max. size including consolidating, finishing, curing etc. complete excluding formwork etc. complete as per drawings, specifications and as directed by EIC.
5
-
-
Construction of Granular sub base by providing coarse graded material as per specified grading, spreading in uniform layers on the prepared surface, mixing at optimum moisture content and compacting with vibratory roller/mechanical earth rammer to achieve the desired density etc. complete as per drawings, specifications and as directed by EIC.
-
-
-
For grading - I material (with 75mm and down size aggregates)
5
-
-
For grading - II material (with 53mm and down size aggregates)
5
-
-
REINFORCED CEMENT CONRETE of M-25 grade using graded stone aggregate of 20mm max. size including machine mixing, weigh batching mechanical vibration, consolidation, finishing, curing and cost of labour, machinery, and materials etc. complete specifications but excluding shuttering, formwork and steel reinforcement. (Minimum Cement content shall not be less than 388kg/cum of concrete.) etc. complete as per drawings, specifications and as directed by EIC.
-
-
-
In foundations, footings, plinth beams, base of columns, flooring.
15
-
-
Providing, centering and shuttering using timber planks/steel plates including strutting and propping etc. upto first floor (not exceeding 4 mtr. height) and removal of the same for in situ reinforced concrete and in plain concrete work etc. complete as per drawings, specifications and as directed by EIC.
-
-
-
Foundations, footings, base of columns plinth beams, flooring, machine foundations, bed blocks, window cills, copings and mass concrete
35
-
-
Providing and fixing reinforcement for reinforced cement concrete using TMT bars, at all levels including supplying, cutting, bending, fixing, tying in position with 1.6mm dia soft drawn annealed binding wire etc. complete including cost of binding wire etc. complete as per drawings, specifications and as directed by EIC.
0.5
-
-
Note: 1.The steel reinforcement bars shall be brought by the contractor at terms & conditions specified.TMT bars shall only be permitted subject to furnishing of challans, valid test report issued by the manufacturer, pertaining to elongation,yield strength,Bend rebend test etc.
-
-
-
Note : 2. Random testing of sample collected at site shall be arranged by the contractor at their own cost.One sample comprisin of three specimens shall be collected for every 25MT of bars brought at site .The representive of department shall associate with the engineer of contractore at each satge right from sampling of testing .All charges ,transport taxes etc shall be borne by the contractor.
-
-
-
Note : 3. the contractor shall be solely respossible all the time for watch & ward of bars/binding wires etc at their own cost.
-
-
-
Note : 4. 1.60mm dia . Soft drawn annealed BINDING WIRE required for the work will have to be procured by the contractore at their own cost and will not be measured for payment .
-
-
-
Note : 5. Other condtion as stipulated in general condition, special conditions, additional conditions and specification shall also be applicable and no claim whatsoever on account of enforcing these provisions shall be entertained .
-
-
-
Providing, fabricating, cutting, erecting, and fixing in position structural steel works of any shape using ISMBs, Joists, channels, angles, flats, Tees etc. at all levels including welding, painting with a primary coat of approved steel primer and transportation etc. complete as per specifications and as directed by Engineer-in-Charge. (The welding weights shall not be measured for payments but cost of same shall be included in the rate.)
0.5
-
-
Providing, fabricating, cutting, erecting, and fixing in position structural steel works of any shape using RHS, SHS & circular hollow sections of Grade Yst 310 as per IS: 4923 at all levels including welding, painting with a primary coat of approved steel primer and transportation etc. complete as per specifications and as directed by Engineer-in-Charge. (The welding weights shall not be measured for payments but cost of same shall be included in the rate.)
3
-
-
Providing, fabricating, cutting, erecting, and fixing in position structural steel works of any shape using Structural steel M.S. plain & chequered plates at all levels including welding, painting with a primary coat of approved steel primer and transportation etc. complete as per specifications and as directed by Engineer-in-Charge. (The welding weights shall not be measured for payments but cost of same shall be included in the rate.)
0.1
-
-
Note:
-
-
-
1. Structural steel conforming to IS: 2062
-
-
-
2. The contractor shall supply copy of Documentary evidence of purchase of steel, test certificates from these firms and also testing from third party, if required to be arranged at no extra cost.
-
-
-
3. Welding weights, connections, bolts and nuts shall not be measured for payment but the cost of which shall be deemed to have been included in the rate.
-
-
-
4. All holes will be made by drilling only. Gas cutting of holes will not be permitted.
-
-
-
5. Electrodes only shall be used.
-
-
-
Brick work in cement mortar 1:6 using table moulded chimney bricks having a compressive strength not less than 40kg/cm² in foundation, plinth upto FFL and compound wall pillars including curing, raking out joints above ground level, simultaneous pointing below G.L. etc. complete as per drawings, specifications and as directed by EIC.
1
-
-
Brick work in cement mortar 1:6 using table moulded chimney bricks having a compressive strength not less than 40kg/cm² in foundation, plinth upto FFL and compound wall pillars including curing, raking out joints above ground level, simultaneous pointing below G.L. etc. complete as per drawings, specifications and as directed by EIC.
1
-
-
Supplying and filling in plinth with screened selected sand under floors, including watering, ramming, consolidating, finishing to level and dressing etc. complete.
1
-
-
Providing and laying rubber moulded reflective type factory made chamfered edge Cement Concrete interlocking paver blocks of following thicknesses in footpath, parks, lawns, drive ways or light traffic parking etc, of M-35 grade strength, of approved size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. Note :- The cost of sand shall be paid separately under relavant item.
-
-
-
80mm thick interlocking paver blocks
20
-
-
Sand faced plaster 20mm thick in 2 coats over exterior masonry and concrete surfaces at all heights with base coat in cement mortar 1:4, 12mm thick and finishing coat in cement mortar 1:3, 8mm thick final rendering, double scaffolding wherever necessary, hacking of concrete surfaces, curing etc. etc. complete as per drawings, specifications and as directed by EIC. and addition of waterproofing compound @ 2% of weight of cement for the base coat etc. etc. complete as per drawings, specifications and as directed by EIC. as per drawings, specifications and as directed by EIC.
10
-
-
Waterproof cement plaster in cement mortar 1:3, with waterproofing compound @ 2% by weight of cement including double scaffolding, curing, hacking of concrete surfaces etc. etc. complete as per drawings, specifications and as directed by EIC..
-
-
-
12mm thick
5
-
-
20mm thick
5
-
-
Painting plastered surfaces with two/three coats of Acrylic emulsion paint of approved shade and make over one coat of approved cement primer including preparing the surfaces, filling with full wall putty, scaffolding and cleaning etc. etc. complete as per drawings, specifications and as directed by EIC.
-
-
-
Two finishing coats over a coat of primer
20
-
-
Repainting of old painted surfaces with two coats of paint of approved shade and make including preparing the surfaces, removal of old paint, if any, sand papering, filling with putty as required, scaffolding and cleaning etc. etc. complete as per drawings, specifications and as directed by EIC..
-
-
-
On plastered surface:
-
-
-
Using ACRYLIC EMULSION paint
10
-
-
Painting the old exterior walls and roof with two coats of acrylic emulsion of approved shade including preparing the surface by removing loose dust and dirt with stiff brush and washing the surface with clean water, treating the surface with antifungal chemical wherever required, filling with putty, scaffolding and cleaning etc. etc. complete as per drawings, specifications and as directed by EIC..
20
-
-
Painting New exterior walls with two coats of Waterproof cement paint of approved shade including preparing the surfaces, filling with putty wherever required, scaffolding and cleaning etc. etc. complete as per drawings, specifications and as directed by EIC..
-
-
-
ON SANDFACED PLASTER SURFACES
-
-
-
Using Waterproof cement paint
20
-
-
Supplying, lowering, laying, RCC Socket & Spigot (S&S) spun pipes (Class NP2) of IS : 458 with necessary collars, laid to correct grade and levels at all depths including cutting to length, jointing with hemp yarn and C.M. 1:1, caulking the joints and finishing, curing, testing etc. etc. complete as per drawings, specifications and as directed by EIC..
-
-
-
150mm n.b
2
-
-
300mm n.b.
2
-
-
Providing and fixing in position 9 mm thick first class double charged vitrified porcelain tiles conforming to IS:15622, of approved manufacturer of size 600mmx 600mm of approved color, pattern and design for flooring, skirting or dado laid in floor, wall of existing concrete or plastered surface over 20 mm thick cement mortar 1:3 bedding close jointed and pointed with matching slurry @ 3.30 kg/sqm using white cement with pigments finished to levels, slope or plumb as required including cement mortar bedding, cutting of tiles to required size and curing, acid washing etc. etc. complete as per drawings, specifications and as directed by EIC..
10
-
-
Preparing the surface and etching with 10% commercial hydrochloric acid wherever necessary, neutralising the etched areas by washing with 5% solution of soda ash, applying one coat of pigmented epoxy based primer followed by one coat of epoxy based trowelling compound, cutting and grinding the surfaces wherever necessary using waterproof quality emery paper and applying three finishing coats of epoxy based polyamine/polyamide cured special acid and alkali resistant paint of approved make & tint including preparing surfaces, scrapping, filling holes, cracks, joints, wherever necessary with epoxy based trowelling compound, cost of all materials, scaffolding and labour and as per manufacturer's recommendations.etc. complete as per drawings, specifications and as directed by EIC.
-
-
-
With POLYAMIDE cured epoxy paint
25
-
-
Providing and fixing 2mm thick epoxy based joint less flooring over existing flooring such as concrete floor, tiles, wood, metal etc. formulated out to required levels, thickness slopes and finished smooth or rough including curing, preparing the surfaces such as filling holes, cracks, joints, wherever necessary by epoxy based trowelling compound, including providing and applying one coat of two component epoxy based primer including cost of materials and labours etc. complete as per manufacturer's recommendation.
25
-
-
Providing, laying jointing and fixing in position Mild steel ERW pipes confirming to IS 1239 having minimum specified thickness Electrodes including providing and fixing all required M.S. Fittings & specials of grade 'C' , cost of transportation to site, welding, testing and a cost of approved steel primer etc. complete as per drawing, specifications and as directed by Engineer-in- charge.
-
-
-
80 mm dia.
50
-
-
100 mm dia.
170
-
-
Supply, Installation and Testing of BUTTERFLY VALVE gear type of one of the etc. conforming to IS 13095 including making necessary joints, providing all jointing materials, greasing using Castrol or Servo grease @ 50 gramme per valve, testing the valves and joints for 16 kg/sqcm pressure with clean and potable water with a minimum testing duration of two hours etc. complete as per drawing, specifications and as directed by Engineer-in- charge.
-
-
-
80 mm dia.
4
-
-
Providing and fixing best Indian make C.I. flanged NON-RETURN VALVE along with a pair of C.I. tail pieces conforming to IS: 5312 (part - I), making necessary flanged joints, providing all jointing materials, testing the valves and joints for 10kg/cm² pressure with clean and potable water for minimum testing duration of two hours etc. complete.
1
-
-
Supplying and installation of best Indian make pressure gauge for water line including making joints, supplying all jointing materials including providing and fixing 3/8” SS ball valve, 3/8” brass, elbow nipple, bush etc. complete including testing the pressure gauge and joints to 16 kg per sq cm pressure with clean and potable water with minimum testing period of two hours duration, all as complete as per drawing and specifications and as directed by Engineer-in-charge.
2
-
-
Providing, jointing and fixing HEAVY QUALITY G.I. FLANGES for m.s. galvanised pipes conforming to IS:778 including bolts, nuts, rubber insertion including testing the joints for 10 kg/cm2 pressure with clean and potable water with a minimum period of two hours duration etc. complete as per specifications and as directed by Engineer-in-charge.
-
-
-
(A) Joint with pair of Flanges
-
-
-
80 mm dia.
4
-
-
(B) Joint with Single Flange.
-
-
-
80 mm dia.
4
-
-
Painting of fire line surfaces with two coats of DECO (AUTOMOTIVE) paint with a coat of primer of approved post office red color/black Deco paint on all fire pipe line headers /flanges/valve /h.p.tank /Diesel tank/pumps/Air compressor /supports etc. including preparing the surfaces, sand papering, filling with putty as required & Spray painting etc. complete as per specifications and as directed by Engineer in Charge. Note: The rate includes cost of all materials, labour, GST & all other taxes, scaffold, tools & tackles, safety appliances etc.
-
-
-
80 mm dia.
50
-
-
100 mm dia.
170
-
-
Providing , installation , testing & commissioning of electric motor driven 30HP centrifugall pump set for Fire Line with a flow capacity of 28 lps at total head of 35 m, with CI casing , standard fitting , CI impeller, mechanical seal ,along with all accessories, suitably rated energy effient inductoin motor F class as electrical drive with synchronous speed not exceeding 2900 rpm , IP-55 rated to operate at 415 v+/- 10%, 50 Hz +/- ,3 phase AC supply , including installing pump, with footvalve in sump, with making suitable arrangment of fitting etc. complete as per specification , drawing and instructions of Engineer in charge , The pump offered shall be of heavy duty and its characteristic shall be as per IS 12469 -1988 or its latest edition including Cost of transportation, footvalve, accessories , tool and tackles , packing etc required to put pumping system into service . NOTE :i) The minimum horse power of electrical operated pump under above item in any case shall not be less than 30 HP or designed horse power whichever is more.
1
-
-
Providing and fixing in position Non-Percolating Flexible Fire Fighting Delivery Hose-63 mm, 15 M long with SS coupling , Type-B conforming to IS-636-2018, ISI marked , including cost of transportation to site and testing etc. complete as per drawing, specifications and as directed by Engineer-in- charge.
8
-
-
Providing and fixing in position Short branch (SS) with 20 mm diameter nozzle conforming to IS- 903, ISI marked , including cost of transportation to site and testing etc. complete as per drawing, specifications and as directed by Engineer-in- charge.
4
-
-
Providing and fixing in position MS Hose box of standard size of 750x600x250 mm, having double door made of FRP with transparent window having transparent acrylic glass -- 3 mm thick & lock, finishing Coats of enamel paint of PO red from outside and white color from inside. , including cost of transportation to site and testing etc. complete as per drawing, specifications and as directed by Engineer-in- charge. (Suitabl to accommodate two nos. of 15 m hoses and one no. branch pipe with nozzle.)
4
-
-