Raja Ramanna Centre For Advanced Technology Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Raja Ramanna Centre For Advanced Technology - RRCAT Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 Jan 2023
Closing Date4 Feb 2023
Tender Amount₹ 4,83,40,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
a) Capacity : 15 TR b) Air Flow Rate : 34500 CFM (1-Tier) c) St. Pressure : 150 mm of WC

3

-

-

... More
a) Capacity : 15 TR b) Air Flow Rate : 34500 CFM (2- Tier) c) St. Pressure : 150 mm of WC

2

-

-

... More
Supply, fabrication, installation, testing and commissioning of Anodized Aluminium ducts fabricated out of following thickness sheets for clean room systems. The ducting shall be complete with bends, elbows, turning vanes (if required), reducers/transition pieces, MS flanged joints, 6 mm thick neoprene gasket, SS hardware, silicon sealant etc. as per drawings and item no. 3 of technical specification.

-

-

-

... More
2.0 mm thick anodised aluminium sheet ducting

50

-

-

... More
1.5 mm thick anodised aluminium sheet ducting

50

-

-

... More
Supply and installation of 19 mm (min.) thick closed cell class '0' zero nitrile rubber insulation with 0.5 mm thick aluminium cladding complete with other accessories such as adhesive, jointing tap, SS/GI hardware etc. as per item no. 04 of technical specification.

100

-

-

... More
Supply and installation of manually operated, multilouvered, opposed aerofoil blade volume control damper with outer body frame and blades fabricated out of extruded aluminium section complete with other accessories such as locking arrangement, gear train, handle, position indicator etc. as per Item no. 5 of technical specification.

5

-

-

... More
Supply and installation of motorised fire cum smoke control damper of following sizes complete with fire & smoke sensors, actuator, control panel and other accessories as per Item no. 6 of technical specification.

-

-

-

... More
1200x1000

1

-

-

... More
1600x1500

1

-

-

... More
1250x1050

1

-

-

... More
2600x1100

1

-

-

... More
2850x1100

1

-

-

... More
2400x1100

1

-

-

... More
1650x1400

1

-

-

... More
1200x1050

1

-

-

... More
900x800

1

-

-

... More
1200x1200

1

-

-

... More
1850x1600

1

-

-

... More
1150x1400

1

-

-

... More
2400x1200

1

-

-

... More
2600x1200

1

-

-

... More
2300x1200

1

-

-

... More
2100x1350

1

-

-

... More
1250x1200

1

-

-

... More
Supply and installation of Air Grilles fabricated out of aluminium extruded section duly powder coated along with volume control damper as per Item no. 7 of technical specification.

1

-

-

... More
Supply and installation of multilouvered heavy duty gravity type 'Back Draft' damper with outer body frame and blades fabricated out of extruded Aluminium section section respectively as per Item no. 8 of technical specification.

15

-

-

... More
Supply and installation of Sound Attenuator with aluminium casing, splitters, acoustic material, fibber glass tissue paper, Aluminium perforated sheet etc. suitable for clean room as per Item no. 9 of technical specification

-

-

-

... More
1200(w)x1000(h)x1500(l)

1

-

-

... More
1850(w)x1600(h)x1500(l)

1

-

-

... More
1250(w)x1050(h)x1500(l)

1

-

-

... More
2600(w)x1100(h)x1500(l)

1

-

-

... More
2850(w)x1100(h)x1500(l)

1

-

-

... More
2400(w)x1100(h)x1500(l)

1

-

-

... More
1650(w)x1400(h)x1500(l)

1

-

-

... More
1200(w)x1050(h)x1500(l)

1

-

-

... More
Supply, installation, testing and commissioning of GI piping of following sizes & thickness / class for chilled water system complete with all required flanges, fittings, gaskets, fasteners, Nitrile rubber insulation covered with Aluminium Cladding etc. as per Item no. 10 of technical specification.

-

-

-

... More
NB 150 mm class C

20

-

-

... More
NB 125 mm class C

36

-

-

... More
NB 100 mm class C

16

-

-

... More
NB 80 mm class C

36

-

-

... More
NB 65 mm class C

45

-

-

... More
NB 50 mm class C

100

-

-

... More
NB 40 mm class C

36

-

-

... More
NB 25 mm class C

20

-

-

... More
Supply, installation, testing and commissioning of flanged end, non rising spindle, PN-16, CI gate valves of following sizes for chilled water system complete with all required counter flanges, fittings, gaskets, fasteners, Nitrile rubber insulation covered with aluminium cladding etc. as per Item no. 11 of technical specification.

-

-

-

... More
DN 100 mm

5

-

-

... More
DN 50 mm

25

-

-

... More
DN 40 mm

18

-

-

... More
Supply, installation, testing and commissioning of flanged end, PN-16, CI balancing valves of following sizes for chilled water system complete with all required counter flanges, fittings, gaskets, fasteners, Nitrile rubber insulation covered with aluminium cladding etc. as per Item no. 12 of technical specification.

-

-

-

... More
DN 100 mm

1

-

-

... More
DN 50 mm

5

-

-

... More
DN 40 mm

3

-

-

... More
Supply, installation, testing and commissioning of flanged end, PN-16, CI Y-strainers of following sizes for chilled water system complete with all required counter flanges, fittings, gaskets, fasteners, Nitrile rubber insulation covered with aluminium cladding etc. as per Item no. 13 of technical specification.

-

-

-

... More
DN 100 mm

1

-

-

... More
DN 50 mm

5

-

-

... More
DN 40 mm

3

-

-

... More
Supply, installation, testing and commissioning of flanged end, PN-16, DI/SS motorised 3-way modulating valves of following sizes for chilled water system complete with BMS compatibility and all required counter flanges and/ fittings, gaskets, fasteners, Nitrile rubber insulation covered with aluminium cladding etc. as per Item no. 14 of technical specification.

-

-

-

... More
DN 100 mm DI valves

1

-

-

... More
DN 50 mm SS valves

5

-

-

... More
DN 40 mm SS valves

3

-

-

... More
Supply, installation, testing and commissioning of threaded end, PN 16/class-150, SS ball valves of following sizes for chilled water system complete with all required nipples, fittings, Nitrile rubber insulation covered with aluminium cladding etc. as per Item no. 15 of technical specification.

-

-

-

... More
40 mm NB

5

-

-

... More
25 mm NB

10

-

-

... More
Supply, installation, testing and commissioning of threaded end, PN 16/class-150 CI auto air vent having SS ball of 25 mm dia suitable for chilled water system complete with all required nipples, fittings, Nitrile rubber insulation covered with aluminium cladding etc. as per Item no. 16 of technical specification

9

-

-

... More
Supply, installation, testing and commissioning of duct heater, control cum power panel box fabricated out of GSS sheet of appropriate thickness with tubular finned heater of following capacity internal lined with 6 mm thick asbestos sheet, complete with thermostat, terminal box, FRLS wires, MCCBs(incomer)/MCB(outgoing), indicator, contactors, control and power cabling, control logic etc. as per Item no. 17 of technical specification.

-

-

-

... More
10 kw

1

-

-

... More
18 kw

1

-

-

... More
50 kw

1

-

-

... More
24 kw

1

-

-

... More
Supply, installation, testing and commissioning of following BMS compatible instruments for measurement and control of various parameters as per Item no. 18 of technical specification.

-

-

-

... More
Humidistat with sensors for measuring & control of relative humidity and suitable for on-off operation of heaters of AHUs.

4

-

-

... More
Airstat/air flow switch suitable for on-off operation of heaters of AHUs.

9

-

-

... More
BMS compatible Thermostat with sensor for measuring & control of temperature and suitable for on-off operation of 3-way mixing valves of AHUs.

9

-

-

... More
0 to 50 deg C range stem type thermometers having 100 mm dia dial with suitable stainless steel thermo wells for measurement of water temperature.

18

-

-

... More
0 to 5 kg/sq. cm. range bourden tube type pressure gauge having 100 mm dia dial, U syphon and cock in stainless steel construction for measurement of water pressure.

18

-

-

... More
Differential Pressure Switch with transmitter

20

-

-

... More
Differential Pressure Sensor with Transmitter (0-60 Pa)

18

-

-

... More
BMS Compatible Smoke Duct Sensor with transmitter

9

-

-

... More
Room Temp & RH Sensor with Transmitter

18

-

-

... More
Temperature, RH and dew point meter at the outlet of MAU

1

-

-

... More
Air flow sensor with Transmitter for MAU

1

-

-

... More
Duct type Temp & RH Sensor with Transmitter

9

-

-

... More
Supply, installation, testing and commissioning of Electromagnetic flow meter of following details for measurement of water flow in pipe lines as per Item no. 19 of technical specification.

-

-

-

... More
0 to 1500 lpm in 100 mm dia. pipe line

1

-

-

... More
0 to 200 lpm in 50 mm dia. pipe line

5

-

-

... More
0 to 200 lpm in 40 mm dia. pipe line

3

-

-

... More
Supply, fabrication, installation and painting of MS structure required for support, flanges etc. required at site as per Item no. 20 of technical specification.

300

-

-

... More
Supply and installation of BMS cables of following sizes as per relevant technical specifications.

-

-

-

... More
2 pair of 4CX 1 sqmm copper armoured multi-stranded FRLS twisted cable.

3600

-

-

... More
1CX 1 sqmm copper unarmoured multi-stranded twisted FRLS cable.

600

-

-

... More
3 pair or 6CX1 sqmm copper unarmoured multi-stranded twisted FRLS cable.

1700

-

-

... More
Modbus cable

300

-

-

... More
Supply and Installation of heavy gauge 25 mm dia PVC conduit .

300

-

-

... More
Design, Fabrication, Supply, Installation, Testing & Commissioning of 3-phase, CRCA fabricated, duly powder coated power control Centre (PCC)/motor control centre (MCC). Motor/Power Control Centre shall be as per item no 23 of technical specification, attached GA drawing /single line diagram & having following configurations:

-

-

-

... More
MCC-1 (For AHU-4,5&6) Incomer:400A, FP, Automatic, On-Load Tap Changer (ATS) with 400A FP MCCB (Ics≥50 kA) with Microprocessor trip release for O/L & S/C & E/F protection (LSIG) having individually adjustable current & time settings Outgoings: 22 kW VFD Feeders:63A, TP MCCB (Ics≥36 kA) with Microprocessor trip release for O/L & S/C & E/F protection (LSIG) having individually adjustable current & time settings) fed 22 kW VVVF Drive along with 63A, AC-3 class, TP contactor & all required switchgears/ equipments & accessories for local & remote operation- 07 Nos.

1

-

-

... More
MCC-2 (For AHU -1,3&8) Incomer: 800A FP MCCB (Ics≥50 kA) with Microprocessor trip release for O/L & S/C & E/F protection (LSIG) having individually adjustable current & time settings Outgoing: 1) 22 kW VFD Feeders: 63A, TP MCCB (Ics≥36 kA) with Microprocessor trip release for O/L & S/C & E/F protection (LSIG) having individually adjustable current & time settings) fed 22 kW VVVF Drive along with 63A, AC-3 class, TP contactor & all required switchgears/equipments & accessories for local & remote operation- 04 Nos. 2) 50 kW Heater Feeders: 125A, TP MCCB (Ics≥36 kA) with Microprocessor trip release for O/L & S/C & E/F protection (LSIG) having individually adjustable current & time settings) fed 125A AC-3 class, TP contactor with overload relay & all required switchgears/equipments & accessories for local & remote operation- 02 Nos. 3) 250A MCCB Feeders: 250A,TP MCCB(Ics≥36kA) with Microprocessor trip release for O/L&S/C&E/F protection (LSIG) having individually adjustable current &time settings- 02 Nos. 4) 10/15/18/24 kW Heater Feeders: 63A, FP MCB (10 kA, D-curve) fed 63A AC-3 class, TP contactor with overload relay & all required switchgears/equipments & accessories for local & remote operation- 04 Nos.

1

-

-

... More
MCC-3 (For AHU-2&7): Incomer: 400A FP MCCB (Ics≥50 kA) with Microprocessor trip release for O/L & S/C & E/F protection (LSIG) having individually adjustable current & time settings Outgoing: 1) 22 kW VFD Feeders: 63A, TP MCCB (Ics≥36 kA) with Microprocessor trip release for O/L & S/C & E/F protection (LSIG) having individually adjustable current & time settings) fed 22 kW VVVF Drive along with 63A, AC-3 class, TP contactor & all required switchgears/equipments & accessories for local & remote operation- 05 Nos.

1

-

-

... More
MCC-4 (For MAU) Incomer: 630A FP MCCB (Ics≥50 kA) with Microprocessor trip release for O/L & S/C & E/F protection (LSIG) having individually adjustable current & time settings Outgoing: 1) 11 kW VFD Feeders: 63A, TP MCCB (Ics≥36 kA) with Microprocessor trip release for O/L & S/C & E/F protection (LSIG) having individually adjustable current & time settings) fed 11 kW VVVF Drive along with 32A, AC-3 class, TP contactor & all required switchgears/equipments & accessories for local & remote operation- 02 Nos. 2) 50 kW Re-heater/Pre-heater Feeders: 125A, TP MCCB (Ics≥36 kA) with Microprocessor trip release for O/L & S/C & E/F protection (LSIG) having individually adjustable current & time settings) fed 125A AC-3 class, TP contactor with overload relay & all required switchgears/equipments & accessories for local & remote operation- 02 Nos. 3) 70 kW Heater Feeders: 160A, TP MCCB (Ics≥36 kA) with Microprocessor trip release for O/L & S/C & E/F protection (LSIG) having individually adjustable current & time settings) fed 160A AC-3 class, TP contactor with overload relay & all required switchgears/equipments & accessories for local & remote operation- 02 Nos. 4) Spare Feeders: 63A, FP MCB (10 kA, D-curve) fed 63A, AC-3 class, TP contactor with overload relay & all required switchgears/equipments & accessories for local & remote operation- 02 Nos.

1

-

-

... More
Fabrication, Supply and installation of Electrozinc perforated type cable trays on wall/metallic structure with standard mounting supports & all required accessories i.e. couplers, nuts & bolts etc as per item no 24 of technical specifications.

-

-

-

... More
300x54mm

40

-

-

... More
150x54mm

80

-

-

... More
Supply, Installation, Testing & Commissioning of 1.1 kV grade, XLPE insulated, FRLS PVC outer sheathed, GI armored, EC grade Copper starnded conductor power cable of the following sizes as per item no 25 of technical specification:

-

-

-

... More
4 core x 16 sq mm

200

-

-

... More
4 core x 50 sq mm

100

-

-

... More
Supply, Installation, Testing & Commissioning of 1.1 kV grade, 3Cx1.5sq. mm, PVC insulated, FRLS PVC outer sheathed, EC grade flexible Copper conductor power cable as per item no 26 of technical specifications.

200

-

-

... More
Supply and installation of end termination for following sizes, LT, XLPE insulated, FRLS PVC outer sheathed, GI armored, EC grade Copper stranded conductor power cable using Heavy duty, Double compression, Brass gland with tinned copper lugs suitable for cable connecting terminals by proper crimping, fixing etc as per site requirement and as per item no 27 of technical specification.

-

-

-

... More
4 core x 16 sq mm Cu Armoured Cable

40

-

-

... More
4 core x 50 sq mm Cu Armoured Cable

12

-

-

... More
Supply and laying GI earthing strip / wire with accessories on/at/in cable tray/MS structure/ wall/trench.

100

-

-

... More
Supply and laying GI earthing strip / wire with accessories in cable tray / wall.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.