Public Works Department Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Public Works Department - PWD Tender
Bridge Construction
Civil And Construction
Eprocure
Opening Date11 Jul 2024
Closing Date2 Aug 2024
Tender Amount₹ 14,29,68,000
Costs
EMD
₹ 10,00,000Document Cost
₹ 30,000Tender Fee
₹ 1,180
Summary
Construction Of Bridges On State Highways And Major District Roads In The State Of Madhya Pradesh Pwd Bridge Division Ujjain.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWDRB_356961_1Bid Award Id
ViewTender No
07/2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://mptenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Mechanical Means
-
-
-
... More
up to 3 m depth
219.56
-
-
... More
3 m to 6m.depth
10.25
-
-
... More
Add extra as follows in the rates of the above items if dewatering is resorted to
-
-
-
... More
up to 3 m depth
219.56
-
-
... More
3 m to 6m.depth
10.25
-
-
... More
Providing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1703 & 2100 with .
-
-
-
... More
RCC Grade M30
111.22
-
-
... More
Pile load test on single vertical pile in accordance with IS:2911(Part-IV)
1050
-
-
... More
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification and as per relevant clauses of sections 1100, 1500 & 1700.
-
-
-
... More
RCC Grade M30
784.45
-
-
... More
Levelling course for Pile cap PCC in M-15 below Pile cap as per drawing and as per section 1100 and 1700.
52.7
-
-
... More
Supplying , fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications and as per relevant clauses of section 1600
95.13
-
-
... More
SUB-STRUCTURE
-
-
-
... More
Plain/reinforced cement concrete in sub-structure complete as per drawing and technical specifications.
-
-
-
... More
RCC grade M30
1074.5
-
-
... More
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications and as per relevant clauses of sections 1600.
161.18
-
-
... More
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC/PVC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications
80.1
-
-
... More
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification and as per relevant clauses 305 of specifications and as per appendix
6 of IRC-78.
-
-
-
... More
Granular material
1634.96
-
-
... More
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
708464
-
-
... More
Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, completre assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per IRC: 83 part-I & II respectively and other parts conforming to BS: 5400, section 9.1 & 9.2 and clause 2006 of MoRTH Specifications complete asper drawing and approved technical specifications.
8236.08
-
-
... More
SUPER STRUCTURE
-
-
-
... More
Furnishing & placing reinforced/presteressed cement concrete in super-structure as per drawing and technical specification and as per relevant clauses of section 1500, 1700 and 2300 in
-
-
-
... More
RCC Grade M30
1846.54
-
-
... More
RCC/PSC Grade M35
1931.39
-
-
... More
a) Supplying, fitting and placing HYSD babar reinforcement in super-structure completes as per drawing and technical specification as per relevant clauses of section 1600 of specification
566.69
-
-
... More
High tensile steel wires/strands including all accessories for stressing, stressing operations and grouting complete as per drawing and Technical Specifications and as per relevant clauses of section 1800.
55.8
-
-
... More
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and technical specifications and as per relevant clauses of section 1500,1700 and clauses 2702 of specifications
461.56
-
-
... More
Drainage Spouts complete as per drawing and Technical specification and as per clause 2705 of specifications
202
-
-
... More
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification and as per relevant clauses of section 1700.
43.63
-
-
... More
Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification and as per relevant clauses of section 1500, 1600,1700 and clause 2704 of specifications.
126
-
-
... More
Strip seal expansion joint catering to maximum horizontal movement up to 70 mm complete as per approved drawings and standard specifications to be installed by the manufacturer/ supplier or their authorized representative ensuring compliance to the manufacturer's instructions for installation.
324
-
-
... More
Testing of span of bridge for deflection due to live load with platforms for loading arrangements apparatus for meaurement including unloading etc. complete as per approved drawing.
327
-
-
... More
Providing and fixing in position Marble Plates of size 0.9 m. x 1.2 m. with inscribed details as per detailed drawings.
16
-
-
... More
Painting Two Coats on New Concrete Surfaces Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces
3220.5
-
-
... More
ROAD WORK
-
-
-
... More
Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. as per relevant clauses of section 300 & 2100 in
-
-
-
... More
Depth upto 3 m
269.28
-
-
... More
Excavation in Soil using Hydraulic Excavator and Tippers withdisposal upto 1000 metres. Excavation for roadwork in soil with ydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location with all lifts and lead upto 1000m as per relevent clauses of section-300 of specification
307.99
-
-
... More
Embankment Construction with Material Obtained from Borrow Pits Construction of embankment with approved material having CBR7 obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-1, 300-2 and as per relevent clauses of section-300.
40405.24
-
-
... More
Crusher Run Macadam Sub Base/Base Course Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor grader, watering and compacting with a vibratory roller to clause 410 to form a layer of sub-base/Base in accordance to Table No. 400-14, 400-15 and as per clause of section 407 of specifications.
-
-
-
... More
For 53 mm maximume Size
2331
-
-
... More
Construction of Shoulders with approved material/selected soil i/c excavation all lifts & leads i/c grading to required slope & camber of 4% and compacting using vibratory roller of 80 to 100 kN static weight to meet requirement as per relevant clause of 400.
-
-
-
... More
Hard Shoulders (CBR value 12)
1833.53
-
-
... More
Dry Lean Cement Concrete Sub- base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 810 tonnes vibratory roller, finishing and curing as per clause 601 of specification complete in all respect.
932.4
-
-
... More
Cement Concrete Pavement Construction of un-reinforced, dowel jointed, plain cement concrete pavement M-40 grade concrete over a prepared sub base with cement , coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures as approved, curing compound, finishing to lines and grades as per drawing as per IRC 15 2011 and as per relevant clauses of section 602 of specifications complete but excluding cost of steel in dowel bar and tie rods etc.
2797.2
-
-
... More
Add extra in Item No.6.3, 6.4, 6.6 & 6.10 above for the cost of steel in dowel bar and tie rod including craddle, laps etc. complete required as per design.
-
-
-
... More
Mild steel
13.25
-
-
... More
Tor steel
1.26
-
-
... More
Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2010 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide clause 801.3.3 fixed over Aluminium composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminium with overall thickness of 4mm and aluminium skin of thickness 0.3 on both side, the ACM shall conform to Table 800-1 of specification and High Intensity Micro Prismatck Grade Sheeting shall conform to Table 800-3 of specification. The printing on the high intensity grade sheeting shall conform to Clause 801.3.7 with water based latex optimized transparent ink as specified by the sheeting manufacturer, supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to ground by means of properly designed foundation with M15 grade concrete 450x450x600mm The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts.
-
-
-
... More
90 cm equilateral triangle
8
-
-
... More
60 cm circular
6
-
-
... More
80 mm x 60 mm rectangular
6
-
-
... More
60 cm x 45 cm rectangular
4
-
-
... More
Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2010 made of high intensity Micro -Prismatic Grade Sheeting (Type IV) vide clause 801.3.3 fixed over Aluminium composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/ sheets of aluminium with overall thickness of 4mm and aluminium skin of thickness 0.3 on both side, the ACM shall conform to Table 800-1 of specification and High Intensity Micro Prismatck Grade Sheeting shall conform to Table 800-3 of specification. The printing on the high intensity grade sheeting shall conform to Clause 801.3.7 with water based latex optimized transparent ink as specified by the sheeting manufacturer, supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to ground by means of properly designed foundation with M15 grade concrete 4500x4500x600 The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts.
-
-
-
... More
90 cm equilateral triangle
2
-
-
... More
60 cm circular
2
-
-
... More
80 mm x 60 mm rectangular
2
-
-
... More
60 cm x 45 cm rectangular
2
-
-
... More
Direction and Place Identification signs with size more than 0.9 sqm size board. (Providing and erecting direction and place identification retroreflectorised sign asper IRC:67 made of high intensity MicroPrismatic Grade Sheeting (Type XI) vide clause 801.3.3 fixed over Aluminium composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminium with overall thickness of 4mm and aluminium skin of thickness 0.3 on both side, the ACM shall conform to Table 800-1 of specification and High Intensity Micro Prismatck Grade Sheeting shall conform to Table 800-3 of specification. The printing on the high intensity grade sheeting shall conform to Clause 801.3.7 with water based latex optimized transparent ink as specified by the sheeting manufacturer, supported on composite sign post of size 75mmx33.55mmx34.99 mm (5mm thick) made of Aluminium composite material in accordance to IRC 67-2010 fixed to ground by means of properly designed foundation with M15 grade concrete 450x450x600mm. The ACM sheet shall be fixed to the post with minimum two number breakaway bolts.
2.4
-
-
... More
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes all complete as per clause 803 of specifications.
180
-
-
... More
Metal Beam Crash Barrier
-
-
-
... More
Type - A, "W" : Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811)
360
-
-
... More
Dismantling of Flexible Pavements
-
-
-
... More
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres.
-
-
-
... More
Prestressed / Reinforced cement concrete grade M-20 & above
378.76
-
-
... More
PROTECTION WORK
-
-
-
... More
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, steping as necessary, removal of stumps and other deleterious matter. Dressing of sides and bottom and backfilling with approved material) etc. and as per relevant clauses of section 300&2100 in
-
-
-
... More
Ordinary soil
-
-
-
... More
Mechanical Means
-
-
-
... More
up to 3 m depth
634.26
-
-
... More
Providing Plain cement concrete M-15 nominal mix in foundation as per relevant clauses of sections 1500, 1700 and 2100.
49.52
-
-
... More
Provdiing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1703 & 2100 with .
-
-
-
... More
RCC Grade M25
176.18
-
-
... More
Supplying , fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications and as per relevant clauses of section 1600
13.21
-
-
... More
Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification
119.01
-
-
... More
Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications
-
-
-
... More
Cement Concrete blocks of size 0.3x0.3 x0.3 m cast in cement concrete of Grade M15
129.46
-
-
... More
DIVERSION WORK
-
-
-
... More
CULVERT
-
-
-
... More
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, steping as necessary, removal of stumps and other deleterious matter. Dressing of sides and bottom and backfilling with approved material) etc. and as per relevant clauses of section 300&2100 in
-
-
-
... More
Ordinary soil
-
-
-
... More
Mechanical Means
-
-
-
... More
up to 3 m depth
206.08
-
-
... More
PCC M-15 in Foundation Plain cement concrete M-15 mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. as per MORT&H Specification 409.
22.01
-
-
... More
Providing P.C.C. M-15 Nominal mix for hume pipe culverts in foundation and sub structure etc. as per drawing and as per relevant clauses of section 1500, 1700, 2100 and 2900.
416.56
-
-
... More
Providing and Laying Reinforced cement concrete pipe NP4 / prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in triple row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets and as per relevant clauses of section-2900.
-
-
-
... More
1200 mm dia
46
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements