Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Public Works Department - PWD Tender

Works
Civil And Construction
Eprocure
Opening Date28 Dec 2024
Closing Date15 Jan 2025
Tender Amount₹ 1,54,34,000 
Notes
Download

Costs

  • EMD

    ₹ 1,54,340
  • Document Cost

    ₹ 12,500
  • Tender Fee

    ₹ 1,534

Summary

Construction Of Vinod Shah House To Parasdehi Shivbahoran Kamlesh Shahu House Road Length 1.50 Km. At Waidhan, Distt- Singrauli (m.p.)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
3.14 Construction of Embankment with Material Deposited from Roadway Cutting Construction of embankment with approved materials CBR7 deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-1, 300-2 and as per relevant clauses of section-300. Usabel qty 70% of cutting qty

2285.41

60

137124.6

... More
Construction of embankment with approved material having CBR7 obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-1, 300-2 and as per relevent clauses of section-300.

7136.12

155

1106098.6

... More
6.15 Providing and laying reinforced cement concrete pipe NP-4 for service ducts below concrete pavement. a) 300 mm Dia

80

713

57040

... More
4.12 Crusher Run Macadam Sub Base/Base Course Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor grader, watering and compacting with a vibratory roller to clause 410 to form a layer of sub-base/Base in accordance to Table No. 400-14, 400-15 and as per clause of section 407 of specifications. (ii) For 37.5 mm maximum size

1305.68

1157

1510665.98

... More
4.11 Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying inuniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density in accordance to Table No. 400-12, 400-13 and as per clause of section 406 of specifications.

1328.91

1493

1984058.15

... More
5.1 Prime coat Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including cleaning of road surface and spraying primer at the rate of 0.75 kg/sqm using mechanical means as per clause 502 of specifications.

5906.25

37

218531.25

... More
5.2 Providing and applying tack coat with catonic bitumen emulsion using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per relevant clauses of section-503 of specifications. (i) @ 0.25 kg per sqm (normal bituminous surfaces)

5906.25

14

82687.56

... More
5.4 Bituminous Macadam Providing and laying bituminous macadam using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with Electronic Sensor paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction and as per clause 504 of specifications. (ii) for GradingII(19 mm nominal size) bitumen content 3.5% with bitumen 60/70 (VG 30)

295.31

5298

1564566.15

... More
5.21 20 mm thick open-grade premix carpet using Bituminous Binder mixing with processed waste plastic by replacing 8% Bitumen binder by weight. (as per 1RC; SP;98-2013). Providing laying and rolling of 20 mm thick open-graded premix carpet (thickness not less than 20 mm at any place) conposed of 13.2 mn graded aggregate size @ 0. 18 cum per 10 sqm &11.2 mm graded size 0.09 cum per 10 sqm using with bituminous binder @ 13.43 kg per 10 Sqm (i.e 92% of standard bitumen) and 8 % waste processed plastic by weight shall be used for coating aggregate after its heating as per IRC:SP:98- 2013, laying to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in s suitable plant, laying and rolling with a three wheel 8 to 10 ton static roller capacity, finished to required level and grades as per technical specification clause 508 to be seal coat of either type A, type B or type C as per technical specification Note- The above shall be included in the DPR and executed with prior written permission from the E-IN-C MPPWD. (i) Bitumen ( VG-10)

5906.25

121

714656.25

... More
5.11 Seal Coat Providing and laying seal coat, sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats, all complete as per clause 511 of Specification. (ii) Case - II : Type B (Providing and laying of premix sand seal coat using HMP of appropriate capacity not less than 75 tonnes/ hours using crushed stone chipping (aggregate shall pass 2.36mm seal and retained to 180 micron sieve) and penetration bitumen VG 30 of suitable grade all complete as per clause 511 of specification.

5906.25

49

289406.25

... More
4.13 Hard Shoulders (CBR value 12 Construction of Shoulders with approved material/selected soil i/c excavation all lifts & leads i/c grading to required slope & camber of 4% and compacting using vibratory roller of 80 to 100 kN static weight to meet requirement as per relevant clause of 400. (B) Average Width of Hard Shoulder = (2.465 + 1.875)/2 = 2.17

2336.25

223

520983.75

... More
8.23 Kilo Metre Stone Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting andprinting etc (ii) Ordinary Kilometer stone (Precast)

1

1984

1984

... More
(iii) Hectometer stone (Precast)

7

578

4046

... More
8.43 Guard Stone Providing and fixing guard stones 220x220x1000mm made of hammer dressed stones or 250 mm (dia) x 1000 mm M-15 concrete and fixed 400mm into the ground in moorum and broken aggregates block of size 500x500x500 mmand given two coats of paints with white and black bands i/c excavation etc. complete.

40

368

14720

... More
8.6 Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over IRC Accredited board made of Advance polymer composite. The board shall be of min. 2.5 mm sheet thickness with specially designed edges to make it tamper proof. Specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on an IRC Accredited triangular sign post of size 75mm x 60 mm x60 mm (4 MM wall thickness) made of advance polymer composite of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum number breakaway bolts. & supported with a back support frame of 25mmx25mmx3mm angle. 10 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor. Note:- Manufacture name and date of manufacture is to be printed (Embossed) at the backside of the board. i) 90cm equilateral triangle

1

3888

3888

... More
ii) 60cm equilateral triangle

4

2926

11704

... More
iii) 60 cm circular

2

3556

7112

... More
iv) 80 mm x 60 mm rectangular

1

4533

4533

... More
vi) 60 cm x 60 cm square

1

3938

3938

... More
vii) 90 cm high octagon

1

5486

5486

... More
8.10 Direction and Place Identification signs upto 0.9 sqm size board Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over IRC Accredited board made of Advance polymer composite. The board shall be of min. 2.5 mm sheet thickness with specially designed edges to make it tamper proof. Specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on

8.1

12937

104789.7

... More
8.16 Metal Beam Crash Barrier Type - A, "W" : Metal Beam Crash Barrier Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811.

90

4500

405000

... More
8.25 Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beeds on Bituminous surface. Providing and applying (Cleaning of Bituminous surface) thermoplastic compound having composition of binder (Regin) minimum 18 %, titanium dioxide minimum 10 % and intermixed glass beed, minimum 30% of brand like Asian, Burger or equivalent make of 2.5 mm thick including drop down

300

636

190800

... More
8.26 Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beeds on Concrete surface. Providing and applying (Cleaning of concrete surface and after applying Concrete primer) thermoplastic compound having composition of binder (Regin) minimum 18 %, titanium dioxide minimum 10 % and intermixed glass beed, minimum 30% of brand like Asian, Burger or equivalent make of 2.5 mm thick including drop down reflectorizing, glass beeds @ 250 gms per sqm area thickness of 2.5 mm is exclusive of surface applied glass beeds as per IRC:35 along with concrete primer. The finished surface to be level, uniform and free from streaks and holes, all complete as per clause 803 of specifications.

300

661

198300

... More
12.1 Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. as per relevant clauses of section 300 & 2100 in I Ordinary soil ( including back filling with approved material) (i) Depth upto 3 m

583.38

61

35586.18

... More
iv) Hard rock (blasting Prohibited )

87.31

1037

90540.47

... More
(Recovery) Rubble available from excavation of hard rock, shall be used to the contractor shall be charged @Rs.100 per cubic meter of rock excavated.

87.31

-100

-8731

... More
9.1 PCC M-15 in Foundation Plain cement concrete M-15 mix with crushed stone aggregate40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. as per MORT&H Specification 409.

16.51

4195

69242.67

... More
9.8 Providing P.C.C. M-15 Nominal mix for hume pipe culverts in foundation and sub structure etc. as per drawing and as perrelevant clauses of section 1500, 1700, 2100 and 2900.

145

4617

669474.23

... More
12.6 Providing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with . A PCC Grade M15

177

4617

817209

... More
9.2 Providing and Laying Reinforced Cement Concrete Pipe NP4/prestrssed concrete pipe on first class bedding in single row. Providing and Laying Reinforced cement concrete pipe NP4/prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. A 1000 mm dia

60

7012

420720

... More
13.2 Supplying, fitting and placing HYSD bar reinforcement in sub- structure complete as per drawing and technical specifications and as per relevant clause of section 1600. FE 500

2.4

80503

193013.99

... More
12.3 Providing Plain cement concrete M-15 nominal mix in foundation as per relevant clauses of sections 1500, 1700 and 2100.

58.32

4349

253620.63

... More
12.6 Providing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with . B PCC Grade M20

97.66

5162

504144.67

... More
13.1 Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications B PCC Grade M20

332.13

5727

1902089.04

... More
F RCC Grade M25 1 Height up to 5 m

12.57

6235

78380.19

... More
14.1 Providing and Placing Reinforced/Prestressed cement concrete in super-structure e/x reinforcement as per drawing and Technical Specification and as per relevant clauses of sections 1500, 1700 and 2300 in B RCC Grade M25 (i) Solid Slab 1 Height up to 5 m

33.18

6034

200208.12

... More
14.6 Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications and as per relevant clauses of sections 1500, 1700 and Clause 2702 of specifications..

4.5

11685

52582.5

... More
12.30 Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications and as per relevant clauses of section 1600. FE 500

0.77

80349

61600.36

... More
14.4 Supplying, fitting and placing HYSD bar reinforcement in super- structure complete as per drawing and technical specifications as per relevant clauses of section 1600 FE 500

5.23

81810

427784.49

... More
13.10 Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification and as per relevant clauses 305 of specifications and as per appendix 6 of IRC-78.

182.58

665

121415.7

... More
13.16 Providing and fixing in position bituminous paper bearing for slabs as per approved drawing and confirming to IS:1398.

30

48

1440

... More
14.19 Filler joint (ii) Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

15

457

6855

... More
14.19 (ii) Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

16.26

4947

80438.22

... More
13.9 Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications

212.76

185

39360.6

... More
14.9 Construction of RCC railing with precast rails and cast in situ vertical post of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post at expansion joints of superstructure for expansion, complete as per approved drawings and technical specifications and as per relevant clauses of sections 1500, 1600, 1700 and clause 2703 of specifications (as per MoST specification drawing SD/201 or SD/304)

17.2

1999

34382.8



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.