Public Works Department Tender
... More
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Public Works Department - PWD Tender
Civil And Construction
Road Construction
Eprocure
Opening Date25 Mar 2025
Closing Date12 Apr 2025
Tender Amount₹ 2,85,98,000
Costs
EMD
₹ 2,85,980Document Cost
₹ 15,000Tender Fee
₹ 1,534
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PWDRB_410305_1Tender No
24/etendering/date 18/03/2025Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://mptenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Embankment Construction with Material Obtained from Borrow Pits
3.13 Embankment Construction with Material Obtained from Borrow Pits Construction of embankment with approved material having CBR7 obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-1, 300-2 and as per relevent clauses of section-300.
12779.71
155
1980855.05
... More
5.21 20 mm thick open-grade premix carpet using Bituminous Binder mixing with processed waste plastic by replacing 8% Bitumen binder by weight. (as per 1RC; SP;98-2013). Providing laying and rolling of 20 mm thick open-graded premix carpet (thickness not less than 20 mm at any place) conposed of 13.2 mn graded aggregate size @ 0. 18 cum per 10 sqm &11.2 mm graded size 0.09 cum per 10 sqm using with bituminous binder @ 13.43 kg per 10 Sqm (i.e 92% of standard bitumen) and 8 % waste processed plastic by weight shall be used for coating aggregate after its heating as per IRC:SP:98- 2013, laying to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in s suitable plant, laying and rolling with a three wheel 8 to 10 ton static roller capacity, finished to required level and grades as per technical specification clause 508 to be seal coat of either type A, type B or type C as per technical specification
Note- The above shall be included in the DPR and executed with prior written permission from the E-IN-C MPPWD. (ii) Bitumen ( VG-30)
13190.63
121
1596066.23
... More
Cable Duct Across the Road
Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98- 1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997 and approved drawings.
(i)Single Row for one utility service
50
1786
89300
... More
Crusher Run Macadam Sub Base/Base Course
Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor grader, watering and compacting with a vibratory roller to clause 410 to form a layer of sub-base/Base in accordance to Table No. 400-14, 400-15 and as per clause of section 407 of specifications.
(ii)For 37.5 mm maximum size
3853.42
1157
4458408.1
... More
Wet Mix Macadam
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density in accordance to Table No. 400-12, 400-13and as per clause of section 406 of specifications.
at Carriageway
2967.89
1493
4431060.67
... More
Prime coat
Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.75 kg/sqm using mechanical means as per clause 502 of specifications.
13190.63
37
488053.31
... More
Tack coat
Providing and applying tack coat with catonic bitumen emulsion (RS-1) using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per relevant clauses of section-503 of specifications.
(i) @ 0.25 kg per sqm (normal bituminous surfaces)
13190.63
14
184668.82
... More
Bituminous Macadam
Providing and laying bituminous macadam using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with Electronic Sensor paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and
501.7 to achieve the desired compaction and as per clause 504 of specifications.
b) Using Drum Mix Plant of appropriate capacity.
(ii) for GradingII(19 mm nominal size) bitumen content
3.5% with bitumen 60/70 (VG 30)
659.53
5298
3494195.24
... More
8.25 Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beeds on Bituminous surface. Providing and applying (Cleaning of Bituminous surface) thermoplastic compound having composition of binder (Regin) minimum 18 %, titanium dioxide minimum 10 % and intermixed glass beed, minimum 30% of brand like Asian, Burger or equivalent make of 2.5 mm thick including drop down reflectorizing, glass beeds @ 250 gms per sqm area thickness of
2.5 mm is exclusive of surface applied glass beeds as per IRC:35.The finished surface to be level, uniform and free from streaks and holes, all complete as per clause 803 of specifications.
Note:- The guarantee of Thermoplastic should be minimum 3 Years.
670
636
426120
... More
Seal Coat
Providing and laying seal coat, sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats, all complete as per clause 511
of Specification.
(ii) Case - II : Type B (Providing and laying of premix sand seal coat using HMP of appropriate capacity not less than 75 tonnes/ hours using crushed stone chipping (aggregate shall pass 2.36mm seal and retained to 180 micron sieve) and penetration bitumen VG 30 of suitable grade all complete as per clause 511 of specification.
13190.63
49
646340.87
... More
Hard Shoulders (CBR value 12)
Construction of Shoulders with approved material/selected soil i/c excavation all lifts & leads i/c grading to required slope & camber of 4% and compacting using vibratory roller of 80 to 100 kN static weight to meet requirement as per relevant clause of 400.
(B) Average Width of Hard Shoulder = (2.465 + 1.875)/2 = 2.17
4759.68
223
1061408.64
... More
Kilo Metre Stone
Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting andprinting etc
(ii) Ordinary Kilometer stone (Precast)
4
1984
7936
... More
(iii) Hectometer stone (Precast)
13
578
7514
... More
Guard Stone Providing and fixing guard stones 220x220x1000mm made of hammer dressed stones or 250 mm (dia) x 1000 mm M-15 concrete and fixed 400mm into the ground in moorum and broken aggregates block of size 500x500x500 mmand given two coats of paints with white and black bands i/c
excavation etc. complete.
On curves or at any other places ad directed by engineer incharge
185
368
68080
... More
8.6 Retro- reflectorised Traffic signs
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over IRC Accredited board made of Advance polymer composite. The board shall be of min. 2.5 mm sheet thickness with specially designed edges to make it tamper proof. Specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table
6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on an IRC Accredited triangular sign post of size 75mm x 60 mm x60 mm (4 MM wall thickness) made of advance polymer composite of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum number breakaway bolts. & supported with a back support frame of 25mmx25mmx3mm angle. 10 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor. ii) 60 cm equilateral triangle
8
2926
23408
... More
iii) 60 cm circular
4
3556
14224
... More
iv) 80 mm x 60 mm rectangular
5
4533
22665
... More
vi) 60 cm x 60 cm square
2
3938
7876
... More
vii) 90 cm high octagon
4
5486
21944
... More
12.10 Sand filling in wells complete as per drawing and technical specifications as per clause 1210.
143.98
1193
171768.14
... More
8.10 Direction and Place Identification signs upto 0.9 sqm size board Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over IRC Accredited board made of Advance polymer composite. The board shall be of min. 2.5 mm sheet thickness with specially designed edges to make it tamper proof. Specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on
6.3
12937
81503.1
... More
Metal Beam Crash Barrier A Type - A, "W" : Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, however 5 spaces of 600mm each between vertical post and 5 spaces of 900mm each between vertical post will be kept adjacent to RCC parapet/ concrete crash barrier in accordance to figure 9.14 of the IRC-SP: 73-2018, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811) and treatment for metal beam cresh barrier on approach shall be modified eccentric loader terminal arrangement as shown in figure 9.12 of IRC- SP : 73-2018 End portion of metal beam crash barrier shall be flared outside by
1.25 mtr. Distance in last section of 8 mtr. Length. Departure side it shall be trailing terminal (TT) arrangement as shown in figure 9.13 of the IRC SP-73- 2018. End portion of metal beam crash barrier shall be flared outside by 0.35 mtr. Distance in last section of 8
mtr. length
20
4500
90000
... More
Excavation for Structures
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. as per relevant clauses of section 300 & 2100 in I Ordinary soil ( including back filling with approved material)
(i) Depth upto 3 m
1190.54
61
72623.06
... More
PCC M-15 in Foundation
Plain cement concrete M-15 mix with crushed stone aggregate40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. as per
MORT&H Specification 409.
28.22
4195
118399.68
... More
Providing P.C.C. M-15 Nominal mix for hume pipe culverts in foundation and sub structure etc. as per drawing and as perrelevant clauses of section 1500, 1700, 2100 and 2900.
246.68
4617
1138907.71
... More
Providing and Laying Reinforced Cement Concrete Pipe NP4/prestrssed concrete pipe on first class bedding in single row. Providing and Laying Reinforced cement concrete pipe NP4/prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. A 1000 mm dia
90
7012
631080
... More
Providing and Laying Reinforced Cement Concrete Pipe NP 4
/prestrssed concrete pipe on first class bedding in double row. Providing and Laying Reinforced cement concrete pipe NP4
/prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry
works in head walls and parapets A 1000 mm dia
10
14168
141680
... More
Supplying, fitting and placing HYSD bar reinforcement in sub- structure complete as per drawing and technical specifications and as per relevant clause of section 1600.
FE 500
6.68
80503
537510.48
... More
12.6 Providing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with .
A PCC Grade M15
44.25
4617
204302.25
... More
Providing Plain cement concrete M-15 nominal mix in foundation as per relevant clauses of sections 1500, 1700 and 2100.
87.67
4349
381285.53
... More
Providing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with .
B PCC Grade M20
334.64
5162
1727422
... More
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications
B PCC Grade M20
482.31
5727
2762200.82
... More
F RCC Grade M25
1 Height up to 5 m
21.31
6235
132867.85
... More
Providing and Placing Reinforced/Prestressed cement concrete in super-structure e/x reinforcement as per drawing and Technical Specification and as per relevant clauses of sections 1500, 1700 and
2300 in
B RCC Grade M25 (i) Solid Slab
1 Height up to 5 m
86.69
6034
523093.49
... More
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications and as per relevant clauses of sections 1500, 1700 and Clause 2702 of specifications.
12.29
11685
143608.65
... More
Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and
technical specifications and as per relevant clauses of section
1600.
0.93
80349
75045.97
... More
Supplying, fitting and placing HYSD bar reinforcement in super- structure complete as per drawing and technical specifications as per relevant clauses of section 1600 FE 500
3.52
81810
288216.63
... More
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification and as per relevant clauses 305 of specifications and as per appendix 6 of IRC-78. A Granular material
182.58
665
121415.7
... More
Filler joint
(ii) Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.
22.5
457
10282.5
... More
Providing and fixing in position bituminous paper bearing for slabs as per approved drawing and confirming to IS:1398.
34.2
48
1641.6
... More
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications
303.76
185
56195.6
... More
Construction of RCC railing with precast rails and cast in situ vertical post of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post at expansion joints of superstructure for expansion, complete as per approved drawings and technical specifications and as per relevant clauses of sections 1500, 1600, 1700 and clause 2703 of specifications (as per MoST specification drawing SD/201 or SD/304)
31.2
1999
62368.8
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%