Public Works Department Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Public Works Department - PWD Tender
Civil And Construction
Bridge Construction
Eprocure
Opening Date6 Feb 2023
Closing Date22 Feb 2023
Tender Amount₹ 28,86,000
Costs
EMD
₹ 50,000Document Cost
₹ 5,000Tender Fee
₹ 341
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_PWDRB_248118_1Bid Award Id
ViewTender No
NIT 13 /SIDHI / 2022-23 /DT 30-01-23Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://mptenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Strengthning work of Agdal Majhiyar Road L- 1.00 Km, Under Sub. Dn. cHURHAT Distt. Sidhi PWD Road AND Bridges SOR w.e.f 25-03-2022
Strengthning work of Agdal Majhiyar Road L- 1.00 Km, Under Sub. Dn. cHURHAT Distt. Sidhi PWD Road AND Bridges SOR w.e.f 25-03-2022
Strengthning work of Agdal Majhiyar Road L- 1.00 Km, Under Sub. Dn. cHURHAT Distt. Sidhi PWD Road AND Bridges SOR w.e.f 25-03-2022
BOQ Items
... More
Filling Pot- holes and Patch Repairs with open - graded Premix surfacing, 20mm. Removal of all failed material, trimming of completed excavation to provide firm vertical faces, cleaning of surface, painting of tack coat on the sides and base of excavation as per clause 503, back filling the pot holes with hot bituminous material as per clause 510, compacting, trimming and finishing the surface to form a smooth continuous surface, all as per clause 3004.2
150
-
134
... More
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with roller to achieve the desired density in accordance to Table No. 400-12, 400 13and as per clause of section 406 of specifications.
11.25
-
1493
... More
Hard Shoulders Construction of Shoulders with approved material/selected soil i/c excavation all lifts & leads i/c grading to required slope & camber of 4% and compacting using vibratory roller of 80 to 100 kN static weight to meet requirement as per relevant clause of 400
(B) Hard Shoulders (CBR value 12)
395
-
223
... More
Prime coat Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.75 kg/sqm using mechanical means as per clause 502 of specifications.
150
-
37
... More
Tack coat Providing and applying tack coat with catonic bitumen emulsion (RS-1) using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per relevant clauses of section-503 of specifications.
(ii) 0.30 kg per sqm (dry & hungry bituminous surfaces /granular surfaces treated with primer)
150
-
16
... More
Tack coat Providing and applying tack coat with catonic bitumen emulsion (RS-1) using emulsion pressure distributor on the prepared ituminous/granular surface cleaned with mechanical broom and as per relevant clauses of section-503 of specifications.
(i) @ 0.25 kg per sqm (normal bituminous surfaces)
3150
-
14
... More
Bituminous Concrete Providing and laying bituminous concrete using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per clause 507 of specification
b) Using Drum Mix Plant of appropriate capacity.
(v) for Grading-II ( 30-45 mm thickness ) Bitumen Content minimum 5.4% with 60/70bitumen(VG-30)
94.5
-
9482
... More
Kilo Metre Stone Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc
(ii) Ordinary Kilometer stone (Precast)
2
-
1984
... More
Kilo Metre Stone Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc
(iii) Hectometer stone (Precast)
5
-
578
... More
Retro- reflectorised Traffic signs Providing and fixing of retro- flectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of highv intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over IRC Accredited board made of dvance polymer composite. The board shall be of min. 2.5 mm sheet thickness with specially designed edges to make it tamper proof. Specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on an IRC Accredited triangular sign post of size 75mm x 60 mm x60 mm (4 MM wall thickness) made of advance polymer composite of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 50x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum number breakaway bolts. & supported with a back support frame of 5mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for out door exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor. ii) 60 cm equilateral triangle (Turning)
8
-
2737
... More
Retro- reflectorised Traffic signs Providing and fixing of retro- flectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of highv intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over IRC Accredited board made of dvance polymer composite. The board shall be of min. 2.5 mm sheet thickness with specially designed edges to make it tamper proof. Specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on an IRC Accredited triangular sign post of size 75mm x 60 mm x60 mm (4 MM wall thickness) made of advance polymer composite of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 50x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum number breakaway bolts. & supported with a back support frame of 5mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for out door exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor. iii) 60 cm circular (Speed Limit & delenator)
2
-
3214
... More
Retro- reflectorised Traffic signs Providing and fixing of retro- flectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of highv intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over IRC Accredited board made of dvance polymer composite. The board shall be of min. 2.5 mm sheet thickness with specially designed edges to make it tamper proof. Specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on an IRC Accredited triangular sign post of size 75mm x 60 mm x60 mm (4 MM wall thickness) made of advance polymer composite of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 50x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum number breakaway bolts. & supported with a back support frame of 5mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for out door exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor. iv) 80 mm x 60 mm rectangular
(Village & School)
2
-
3952
... More
Retro- reflectorised Traffic signs Providing and fixing of retro- flectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of highv intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over IRC Accredited board made of dvance polymer composite. The board shall be of min. 2.5 mm sheet thickness with specially designed edges to make it tamper proof. Specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on an IRC Accredited triangular sign post of size 75mm x 60 mm x60 mm (4 MM wall thickness) made of advance polymer composite of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 50x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum number breakaway bolts. & supported with a back support frame of 5mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for out door exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor. v) 60 cm x 45 cm rectangular
(Hospel & Petrol Pump)
2
-
3165
... More
Retro- reflectorised Traffic signs Providing and fixing of retro- flectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of highv intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over IRC Accredited board made of dvance polymer composite. The board shall be of min. 2.5 mm sheet thickness with specially designed edges to make it tamper proof. Specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on an IRC Accredited triangular sign post of size 75mm x 60 mm x60 mm (4 MM wall thickness) made of advance polymer composite of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 50x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum number breakaway bolts. & supported with a back support frame of 5mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for out door exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor. vi) 60 cm x 60 cm square
(Speed Breaker)
2
-
3502
... More
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beeds on Bituminous surface. Providing and applying (Cleaning of Bituminous surface) thermoplastic compound having composition of binder (Regin) minimum 18 %, titanium dioxide minimum 10 % and intermixed glass beed, minimum 30% of brand like Asian, Burger or equivalent make of 2.5 mm thick including drop down reflectorizing, glass beeds @ 250 gms per sqm area thickness of 2.5 mm is exclusive of surface applied glass beeds as per IRC:35.The finished surface to be level, uniform and free from streaks and holes, all complete as per clause 803 of specifications.
40
-
636
... More
Providing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with .
B PCC Grade M20
70.5
-
5162
... More
A Type - A, "W" : Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, however 5 paces of 600mm each between vertical post and 5 spaces of 900mm each between vertical post will be kept adjacent to RCC parapet/ concrete crash barrier in accordance to figure 9.14 of the IRC-SP: 73-2018, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811) and treatment for metal beam cresh barrier on approach shall be modified eccentric (For Ex VCW Culvert)
230
-
4500
... More
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications and as per relevant clauses of sections 1500, 1700 and Clause 2702 of specifications..
16.88
-
11685
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements