Public Works Department Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Public Works Department - PWD Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date5 Dec 2022
Closing Date20 Dec 2022
Tender Amount₹ 2,99,49,000 
Notes
Download

Costs

  • EMD

    ₹ 2,99,490
  • Document Cost

    ₹ 15,000
  • Tender Fee

    ₹ 1,534

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
B Above 600 mm to 900 mm dia

22.5

-

252

... More
Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 metres. Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting suitable earth to the embankment location and disposing off unsuitable earth with all lifts and lead upto 1000m as per relevent clauses of section-300 of specification..

2286

-

55

... More
Construction of Embankment with Material Deposited from Roadway Cutting Construction of embankment with approved materials having CBR7 deposited at site from roadway cutting and excavation from drain or foundation of structures graded and compacted to meet requirement of table 300-1, 300-2 and as per relevent clauses of section-300.

453.6

-

60

... More
Embankment Construction with Material Obtained from Borrow Pits Construction of embankment with approved material having CBR7 obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-1, 300-2 and as per relevent clauses of section-300.

20245.4

-

155

... More
(i) For 37.5 mm maximum size

4266.44

-

1157

... More
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density in accordance to Table No. 400-12, 400-13 and as per clause of section 406 of specifications.

3302.23

-

1493

... More
Construction of Shoulders with approved material/selected soil i/c excavation all lifts & leads i/c grading to required slope & camber of 4% and compacting using vibratory roller of 80 to 100kN static weight to meet requirement as per relevant clause of 400.B Hard Shoulders (CBR value 12)

4956.16

-

223

... More
Prime coat Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.75 kg/sqm using mechanical means as per clause 502 of specifications.

14676.56

-

37

... More
Providing and applying tack coat with catonic bitumen emulsion (RS-1) using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per relevant clauses of section-503 of specifications.(ii) @0.30 kg per sqm (dry & hungry bituminous surfaces /granular surfaces treated with primer)

14676.56

-

16

... More
Open - Graded Premix Surfacing Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or cut-back or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades all complete as per clause 510 of specification(i) Case - I: Mechanical method using Penetration grade Bitumen VG 30 and HMP of appropriate capacity not less than 75 tonnes/hour.

14676.56

-

117

... More
Seal Coat Providing and laying seal coat, sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats, all complete as per clause 511 of Specification.(ii) Case - II : Type B (Providing and laying of premix sand seal coat using HMP of appropriate capacity not less than 75 tonnes/ hours using crushed stone chipping (aggregate shall pass 2.36mm seal and retained to 180 micron sieve) and penetration bitumen VG 30 of suitable grade all complete as per clause 511 of specification.

14676.56

-

49

... More
Dry Lean Cement Concrete Sub- base Construction of dry lean cement concrete Sub- base over a prepared sub-grade or drainage layer with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver finisher with electronic sensor, compacting with 8- 10 tonnes vibratory roller, finishing and curing as per clause 601 of specification complete in all respect.

33

-

2767

... More
Deduct from Item No.6.1 above if paver finisher with electronic sensor, vibratory roller are not used and laying, compaction is done by any other method.

33

-

150

... More
Cement Concrete Pavement Construction of un-reinforced, dowel jointed, plain cement concrete pavement with M-30 grade concrete over a prepared sub base with cement , coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with electronic sensor slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures as approved, curing compound, finishing to lines and grades as per drawing as per IRC 15 2011 and as per relevant clauses of section 602 of specifications complete but excluding cost of steel in dowel bar and tie rods etc.

412.5

-

6103

... More
Deduct from Item No.6.3 & 6.4 above if slip from paver with electronic sensor is not used and laying, compaction is done by any other method

412.5

-

350

... More
Add extra in Item No.6.3, 6.4, 6.6 & 6.10 above for the cost of steel in dowel bar and tie rod including craddle, laps etc. complete required as per design I) Mild steel 32mm dia @4.5 m C/C 450 mm in langth

4.97

-

63587

... More
ii) Tor steel

0.42

-

68297

... More
Providing and laying reinforced cement concrete pipe NP-4 for service ducts below concrete pavement.(a) 300 mm Dia

30

-

713

... More
(b) 600 mm Dia

20

-

1950

... More
Cable Duct Across the Road Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills,constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts,joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997 and approved drawings. Single Row for One utility Service Metre

100

-

1786

... More
Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2012 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall onform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on an IRC Accredited triangular sign post of size 75mm x 60 mm x60 mm (4 MM wall thickness) made of advance polymer composite of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum number breakaway bolts. & supported with a back support frame of 25mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for out door exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor. 90 cm equilateral triangle

4

-

4357

... More
60 cm equilateral triangle

3

-

3066

... More
60 cm circular

3

-

3911

... More
80 mm x 60 mm rectangular

4

-

5222

... More
Direction and Place Identification signs upto 0.9 sqm size board. Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2012 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back support frame of 25mmx25mmx3mm angle. 10 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor.

2.16

-

8893

... More
Kilo Metre Stone Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc 5th kilometre stone (precast) Ordinary Kilometer stone (Precast)

4

-

1984

... More
Hectometer stone (Precast)

15

-

578

... More
Metal Beam Crash Barrier Type - A, "W" : Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, however 5 spaces of 600mm each between vertical post and 5 spaces of 900mm each between vertical post will be kept adjacent to RCC parapet/ concrete crash barrier in accordance to figure 9.14 of the IRC-SP: 73-2018, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811) and treatment for metal beam cresh barrier on approach shall be modified eccentric loader terminal arrangement as shown in figure 9.12 of IRC- SP : 73-2018 End portion of metal beam crash barrier shall be flared outside by 1.25 mtr. Distance in last section of 8 mtr. Length. Departure side it shall be trailing terminal (TT) arrangement as shown in figure 9.13 of the IRC SP-73-2018. End portion of metal beam crash barrier shall be flared outside by 0.35 mtr. Distance in last section of 8 mtr. length

60

-

4500

... More
Boundary pillar Reinforced cement concrete M15 grade boundary pillars of standard design as per IRC:25-1967, fixed in position including finishing and lettering but excluding painting

60

-

546

... More
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and applying (Cleaning of Bituminous surface) thermoplastic compound having composition of binder (Regin) minimum 18 %, titanium dioxide minimum 10 % and intermixed glass beed, minimum 30% of brand like Asian, Burger or equivalent make of 2.5 mm thick including drop down reflectorizing, glass beeds @ 250 gms per sqm area thickness of 2.5 mm is exclusive of surface applied glass beeds as per IRC:35.The finished surface to be level, uniform and free from streaks and holes, all complete as per clause 803 of specifications.

155

-

636

... More
Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom as per relevant clauses of section 300 & 2100 in 1.Ordinary soil ( including back filling with approved material) (i) Depth upto 3 m

744.07

-

61

... More
(II) Ordinary Rock (ii) Depth upto 3 m

128.33

-

77

... More
Add extra as follows in the rates of the above items if dewatering is resorted to (II) Ordinary Rock (ii) Depth upto 3 m

431.51

-

92

... More
III Ordinary Rock (not requiring blasting ) (ii) Depth upto 3 m

128.33

-

116

... More
PCC M-15 in Foundation Plain cement concrete M-15 mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. as per MORT&H Specification 409.

22.32

-

4195

... More
Providing P.C.C. M-15 Nominal mix for hume pipe culverts in foundation and sub structure etc. as per drawing and as per relevant clauses of section 1500, 1700, 2100 and 2900.

213.47

-

4617

... More
Providing Plain cement concrete M-15 nominal mix in foundation as per relevant clauses of sections 1500, 1700 and 2100.

42.28

-

4349

... More
(A) Provdiing and laying Plain/Reinforced cement concrete inopen foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with .PCC GRADE M20

294.56

-

5162

... More
PCC GRADE M15

67.84

-

4617

... More
Providing and Laying Reinforced Cement Concrete Pipe NP4/prestrssed concrete pipe on first class bedding in single row. Providing and Laying Reinforced cement concrete pipe NP4/prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. (A) 1000 mm dia

100

-

7012

... More
Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications and as per relevant clauses of section 1600

1.23

-

81349

... More
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications. B PCC Grade M20

299.33

-

5727

... More
Supplying, fitting and placing HYSD bar reinforcement in substructure complete as per drawing and technical specifications and as per relevant clause of section 1600

0.14

-

80503

... More
FE 500D/ FE 550/ FE 550D

4.01

-

81530

... More
Providing and Placing Reinforced/Prestressed cement concrete in super-structure e/x reinforcement as per drawing and Technical Specification and as per relevant clauses of sections 1500, 1700 and 2300 in B RCC Grade M25

56.29

-

6034

... More
RCC Grade M 30

25.58

-

6386

... More
Supplying, fitting and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications as per relevant clauses of section 1600

13.9

-

82810

... More
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications and as per relevant clauses of sections 1500, 1700 and Clause 2702 of specifications..

17.29

-

11685

... More
A Providing Back filling behind abutment, wing wall and return wall with Granular Material complete as per drawing and Technical specification and as per relevant clauses 305 of specifications and as per appendix 6 of IRC-78

294.82

-

1193

... More
Providing and laying of Filter media with granularmaterials/stone crushed aggregates satisfying the requirementslaid down in clause 2504.2.2 of MoRTH specifications to athickness of not less than 600 mm with smaller size towards thesoil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the fullheight compacted to a firm condition complete as per drawingand technical specification

207.9

-

750

... More
Providing weep holes in brick masonry/plain/reinforced comcrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1 V : 20 H towards drawings foce.Complete as per drawing and technical specification.

249.28

-

185

... More
Filler joint (ii)Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification

73.92

-

457

... More
Providing and fixing in position bituminous paper bearing for slabs as per approved drawing and confirming to IS:1398.

15.12

-

48

... More
Crash Barriers for Bridge provision of an Reinforced cement concrete M40 crash barrier at the bridge decks & approaches to bridge structures, constructed with Reinforced Cement concrete with HYSD reinforcement Conforming MoRT&H Specification and as per details given IRC-S including dowel bars, excluding reinforcement expansion joints filled with pre- moulded asphalt filler board etc. and approved drawing and at locations directed by the Engineer, all as specified.

26.67

-

7031

... More
Drainage Spouts complete as per drawing and Technical specification and as per clause 2705 of specifications.

10

-

1311

... More
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification and as per relevant clauses of section 1700.

17.64

-

4664

... More
Reinforced cement concrete approach slab (Gard of concrere M 30) including reinforcement and formwork complete as per drawing and Technical specification and as per relevant clauses of section 1500, 1600, 1700 and clause 2704 of specifications.

35.28

-

9683

... More
Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification.(A) Boulder laid dry without wire crates.

43.2

-

2211



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.