Public Works Department Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Public Works Department - PWD Tender
Civil And Construction
Road Construction
Eprocure
Opening Date3 Feb 2025
Closing Date24 Feb 2025
Tender Amount₹ 11,16,77,452
Costs
EMD
₹ 10,00,000Document Cost
₹ 30,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PWDRB_398631_1Tender No
08/Gen./2024-25 Dt. 27-01-2025Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://mptenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Crusher Run Macadam Sub Base/Base Course
Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor grader, watering and compacting with a vibratory roller as per clause 410 to form a layer of sub-base/Base in accordance to Table No. 400-14, 400-15 and as per clause of section 407 of specifications
(ii)For 37.5 mm maximum size
20055.92
1157
23204704.07
... More
Wet Mix Macadam
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density in accordance to Table No. 400-12, 400-13 and as per clause of section 406 of specifications.
Construction of Shoulders with approved material/selected soil i/c excavation all lifts & leads i/c grading to required slope & camber of 4% and compacting using vibratory roller of 80 to 100kN static weight to meet requirement as per relevant clause of 400.
15734.25
1493
23491235.25
... More
B Hard Shoulders (CBR value 12) .
22738.13
223
5070602.99
... More
Prime coat
Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.75 kg/sqm using mechanical means as per clause 502 of specifications Providing and applying tack coat with catonic bitumen emulsion (RS-1) using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per relevant clauses of section-503 of specifications.
69930
37
2587410
... More
(ii) @0.30 kg per sqm (dry & hungry bituminous surfaces /granular surfaces treated with primer) Dense Graded Bituminous Macadam
Providing and laying dense bituminous macadam using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per clause 505 of specificat
69930
16
1118880
... More
Open - Graded Premix Surfacing
Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or cut-back or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades all complete as per clause 510 of specification.
(i) Case - I: Mechanical method using Penetration grade Bitumen VG 30 and HMP of appropriate capacity not less than75 tonnes/hour.
69930
117
8181810
... More
Seal Coat
Providing and laying seal coat, sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats, all complete as per clause 511
of Specification.
(ii) Case - II : Type B (Providing and laying of premix sand seal coat using HMP of appropriate capacity not less than 75 tonnes/ hours using crushed stone chipping (aggregate shall pass 2.36mm seal and retained to 180 micron sieve) and penetration bitumen VG 30 of suitable grade all complete as per clause 511 of specification.
69930
49
3426570
... More
Retro- reflectorised Traffic signs
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2012 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table
6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back support frame of 25mmx25mmx3mm angle. 10 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor.
Note:- Manufacture name and date of manufacture is to be printed (Embossed) at the backside of the board.
i) 90 cm equilateral triangle
6
4357
26142
... More
ii) 60 cm equilateral triangle
12
3066
36792
... More
iii) 60 cm circular
6
3911
23466
... More
iv) 80 mm x 60 mm rectangular
6
5222
31332
... More
v) 60 cm x 45 cm rectangular
2
3825
7650
... More
(i) Single Row for one utility service metre
850
1786
1518100
... More
Excavation for Structures
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom as per relevant clauses of section 300 & 2100 in
1.Ordinary soil ( including back filling with approved material)
(i) Depth upto 3 m
4064.13
61
247911.93
... More
Guard Stone Providing and fixing guard stones 220x220x1000mm made of hammer dressed stones or 250 mm (dia) x 1000 mm M-15 concrete and fixed 400mm into the ground in moorum and broken aggregates block of size 500x500x500 mmand given two coats of paints with white and black bands i/c
excavation etc. complete.
On curves or at any other places ad directed by engineer incharge
600
368
220800
... More
vi) 60 cm x 60 cm square
2
4424
8848
... More
vii) 90 cm high octagon
6
6500
39000
... More
Direction and Place Identification signs more than 0.9 sqm size board.
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2012 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause
801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back support frame of 25mmx25mmx3mm angle. 10 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor.
35.1
15506
544260.6
... More
PCC M-15 in Foundation
Plain cement concrete M-15 mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. as per MORT&H Specification 409.
121
4195
507595
... More
Providing P.C.C. M-15 Nominal mix for hume pipe culverts in foundation and sub structure etc. as per drawing and as per relevant clauses of section 1500, 1700, 2100 and 2900.
1703.63
4617
7865659.71
... More
Providing Plain cement concrete M-15 nominal mix in foundation as per relevant clauses of sections 1500, 1700 and 2100.
376.12
4349
1635745.88
... More
(A) Provdiing and laying Plain/Reinforced cement concrete inopen foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with .
PCC GRADE M20
416.91
5162
2152089.42
... More
(A) 1000 mm dia
Laying Reinforced Cement Concrete Pipe NP 4 /prestrssed concrete pipe on first class bedding in double row. Providing and Laying Reinforced cement concrete pipe NP4/prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets.
440
7012
3085280
... More
Kilo Metre Stone Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting andprinting etc
(i) 5th kilometre stone (precast)
2
3275
6550
... More
Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications and as per relevant clauses of section 1600
16.86
80349
1354684.14
... More
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications. B PCC Grade M20
984.83
5727
5640121.41
... More
F RCC Grade M-25
53.28
6235
332200.8
... More
Supplying, fitting and placing HYSD bar reinforcement in substructure complete as per drawing and technical specifications and as per relevant clause of section 1600
16.93
80503
1362915.79
... More
Providing and Placing Reinforced/Prestressed cement concrete in super-structure e/x reinforcement as per drawing and Technical Specification and as per relevant clauses of sections 1500, 1700 and 2300 in B RCC Grade M25
93.63
6034
564963.42
... More
Supplying, fitting and placing HYSD bar reinforcement in super- structure complete as per drawing and technical specifications as per relevant clauses of section 1600 FE 500
4.37
81810
357509.7
... More
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications and as per relevant clauses of sections 1500, 1700 and Clause 2702 of specifications..
15.75
11685
184038.75
... More
A Providing Back filling behind abutment, wing wall and return wall with Granular Material complete as per drawing and Technical specification and as per relevant clauses 305 of specifications and as per appendix 6 of IRC-78
605.93
665
402943.45
... More
Providing weep holes in brick masonry/plain/reinforced comcrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1 V : 20 H towards drawings foce.Complete as per drawing and technical specification.
801.76
185
148325.6
... More
Filler joint
(ii)Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification
90
457
41130
... More
Providing and fixing in position bituminous paper bearing for slabs as per approved drawing and confirming to IS:1398.
52.5
48
2520
... More
Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications and as per relevant clauses of sections 1500, 1600, 1700 and clause 2703 of specifications (as per MoST
specification drawing SD/201 or SD/304)
63.2
1999
126336.8
... More
Providing and Placing Reinforced/Prestressed cement concrete in super-structure e/x reinforcement as per drawing and Technical Specification and as per relevant clauses of sections 1500, 1700 and
2300 in A RCC Grade M 20 (i) Solid Slab 1 Height up to 5 m
58.5
5447
318649.5
... More
Kilo Metre Stone Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc (iii) Ordinary Kilometer stone (Precast)
20
1984
39680
... More
(iii) Hectometer stone (Precast
72
578
41616
... More
Metal Beam Crash Barrier
Type - A, "W" : Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, however 5 spaces of 600mm each between vertical post and 5 spaces of 900mm each between vertical post will be kept adjacent to RCC parapet/ concrete crash barrier in accordance to figure 9.14 of the IRC-SP: 73-2018, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811) and treatment for metal beam cresh barrier on approach shall be modified eccentric loader terminal arrangement as shown in figure 9.12 of IRC- SP : 73-2018 End portion of metal beam crash barrier shall be flared outside by 1.25 mtr. Distance in last section of 8 mtr. Length. Departure side it shall be trailing terminal (TT) arrangement as shown in figure 9.13 of the IRC SP-73- 2018. End portion of metal beam crash barrier shall be flared outside by 0.35 mtr. Distance in last section of 8mtr. length
400
4500
1800000
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%