Public Health Engineering Department Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Public Health Engineering Department - PHED Tender
Civil And Construction
Drainage Work
Eprocure
Opening Date11 Dec 2024
Closing Date26 Dec 2024
Tender Amount₹ 7,19,429
Costs
EMD
₹ 14,389Document Cost
₹ 2,000Tender Fee
₹ 295
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PHED_387580_1Bid Award Id
ViewTender No
114/11.12.2024Tender Authority
Public Health Engineering Department ViewPurchaser Address
-Website
http://https://mptenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Demolishing Brick work in lime or cement mortar in any mix including stacking of serviceable material and disposal of unserviceable material with in 50 meter lead as per direction of engineer-in-charge.
( In cement mortar )
( PHE USOR wef. 01.09.2023 It. No. 15.15 P.No. 258 ) 18x0.785x[((1.60+1.20)/2)²-((1.20+0.80)/2)²]x0.60= 8.14 Cum
8.14
740
6023.6
... More
Brick work with well burnt chimney bricks having crushing strength not less than 25 kg/cm² and water absorption not more than 20 % in foundation & plinth i/c curing etc. complete.
(ii) in cement mortar 1:4
( PHE USOR wef. 01.09.2023 It. No. 15.40.2 P.No. 262 )18x0.785x[((1.60+1.20)/2)²-((1.20+0.80)/2)²]x1.00= 13.56
13.56
6226
84424.56
... More
Replacement of M.S. Foot rests in manhole including dismantling concrete block and fixing with 20x20x10 cm C.C. blocks of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) With 20mm square bar foot rest
( PHE USOR wef. 01.09.2023 It. No. 29.21.1 P.No. 376 )
54
309
16686
... More
12 mm thick cement plaster in single coat finished smooth and curing including cost of form work complete.
(i) in cement mortar 1:3
( PHE USOR wef. 01.09.2023 It. No. 15.46.2 P.No. 262 ) 18x3.14x(1.60+1.20/2)x1.00= 79.13
18x3.14x(1.20+0.80/2)x1.00= 56.52 Total 135.65
135.65
190
25773.5
... More
Providing & fixing of ISI marked pre cast reinforced cement concrete manhole cover including frame and transporting at site, cost of all material etc. 560 mm dia heavy duty.
( PHE USOR 1st Amendment wef. 01.09.2023 It. No. 29.25.5 P.No. 3)
18
2916
52488
... More
Filling available excavated earth in trenches, lead up to 50m and lift up to 1.5m in all kind of soil excluding watering and ramming.
( PHE USOR wef. 01.09.2023 It. No. 15.12 P.No. 258 )
53.22
31
1649.82
... More
Providing and laying mechanically mixed cement concrete with crushed stone aggregate excluding centering and shuttering (with 20mm nominal size graded stone aggregate)
(a) In plinth and foundation (ii) 1:2:4 (M-15)
( PHE USOR wef. 01.09.2023 It. No. 15.31.1.2 P.No. 260 ) For c:c road
18x{(1.60x1.60x0.25)-(0.785x0.85²x0.25)}= 8.97 +
5x{(2.10x2.10x0.25)-(0.785x0.85²x0.25)}=4.80+
for coping 18x0.785x(1.20²-0.80²)x0.05=0.56 Total 14.33
14.33
5363
76851.79
... More
Dismantling of manhole including R.C.C./C.C. top slab, CI / pre cast RCC cover with frame including stacking of useful materials near the site and disposal of unserviceable materials into municipal dumps within 50 m lead.
Manhole 1.50 m dia circular, and 2.65 m deep
( PHE USOR wef. 01.09.2023 It. No.29.19.5 P.No.376 )
5
3506
17530
... More
Pumping out to removed the sewers blockage by using suitable pump sets operated by generators , whole assembly mounted on two/four wheels trailer / pickup van. Including diesel & labour charges etc.
( PHE USOR wef. 01.09.2023 It. No. 15.22 P.No. 376 )
54
364
19656
... More
Constructing Brick Masonry Circular Man Hole 1500 mm internal dia at bottom & 560 mm dia at top in cement Mortar 1:4 (1 cement: 4 fine sand), inside Cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement, foundation concrete 20 cm thick in 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement etc. all complete. For one manhole 2650 mm deep with fixing of 560 mm dia ISI marked reinforcement cement concrete cover & frame heavy duty including transportation etc. in cement concrete 1:2:4 all complete. ( Excavation, foot rests & cement plaster at the external surface shall be paid for separately )
( PHE USOR 1st Amendment wef. 01.09.2023 It. No.29.10.1 P.No.2 )
5
27395
136975
... More
Providing MS foot rests i/c fixing in manhole with 20x20x10cm CC blocks of 1:3:6 (1 cement:3 coarse sand : 6 graded stone aggregate 20mm nominal size ) With 20mm square bar foot rest
( PHE USOR wef. 01.09.2023 It. No.29.14.1 P.No.374 )
15
317
4755
... More
Making connection of drain or sewer line with existing service lines Manhole including breaking into and making good the walls, floors etc. with cement concrete 1 :2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), cement plastered with CM 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels etc. complete.
For 100 to 200 mm dia pipes.
( PHE USOR wef. 01.09.2023 It. No.29.15.1 P.No.375 )
10
384
3840
... More
Providing & fixing of ISI marked pre cast reinforced cement concrete manhole cover without frame and transporting at site, cost of all material etc.
560 mm dia heavy duty
( PHE USOR 1st Amendment wef. 01.09.2023 It. No.29.26.5 P.No.3 )
10
2090
20900
... More
Lifting & Placing of manhole cover during cleaning of chocked sewer line & manhole.
(ii) SFRC 560 mm dia size
( PHE USOR wef. 01.09.2023 It. No.29.27 P.No.377 )
45
41
1845
... More
Making arrangement for dat (plugging of sewer) including all required material such as steel plate, manila rope, gunny bags, earth etc. or by and other plugging device with all required T & P and safety equipment including dewatering.
Depth up to 1.5 m
( PHE USOR wef. 01.09.2023 It. No. 29.31.1.3 to 29.31.1.4 and 29.31.5.3 P.No.378-379 )
200 mm dia
54
994
53676
... More
250 mm dia
28
999
27972
... More
300 mm dia
16
1004
16064
... More
450 mm dia
14
1389
19446
... More
Cleaning of Silt, sludge brick bats, polythene bags, garbage etc. from chocked sewer manholes / sewer drains & Nallahs/ wet well of SPH/ Anaerobic & Facultative Pond of STP with all required T&P such as bucket, manila rope, and all required safety equipment such as safety belt, gas mask, oxygen cylinder etc. including disposal of silt/ sludge upto 50 mtr lead & 1.5 mtr. lift as directed by Engineer-in-Charge including dewatering but excluding dat (plugging of sewer pipe line) Depth up to 1.50 m
( PHE USOR wef. 01.09.2023 It. No. 29.32 P.No.380 )
45x0.785x1.20x1.20x0.75=38.15
38.15
550
20982.5
... More
Cleaning of Silt, sludge brick bats, polythene bags, garbage etc. from chocked sewer line with all required T&P and Safety equipment such as bucket, manila rope, safety belt, gas mask, oxygen cylinder etc. including disposal of silt, sludge upto 50m lead & lift up to 1.5mtr. as directed by Engineer-in- Charge including dewatering but excluding dat (plugging of sewer pipe line)
( PHE USOR wef. 01.09.2023 It. No.29.33 P.No.380 )
200 mm dia
412
62
25544
... More
250 mm dia
280
73
20440
... More
300 mm dia
185
87
16095
... More
450 mm dia
65
427
27755
... More
Carriage of desilted sludge & other material from sewage components by mechanical transport including loading unloading & stacking etc. Distance 5 Km.
( PHE USOR 1st Amendment wef. 01.09.2023 It. No.29.35.5 P.No.3 )
(-) 20% of 38.15 for air voids = 30.52
30.52
218
6653.36
Evaluation Notes How It Works ?