NHDC Limited Tender
... More
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
NHDC Limited - NHDC Tender
Eprocure
Opening Date4 Aug 2018
Closing Date4 Oct 2018
Tender Amount₹ 5,48,09,851
Costs
EMD
₹ 10,96,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_NHDC_368002_1Bid Award Id
ViewTender No
NIT No. 11/1128/2018-19 Dated 26/07/2018Tender Authority
NHDC Limited ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Up-gradation and Underground cabling work for Electrical HT/LT Power Distribution system of NHDC Residential Premises of Indira Sagar Power Station, Narmada Nagar, Distt Khandwa (M.P.)
BOQ Items
... More
Supply of 70 sq.mm, 4 core, 1.1 KV, aluminium conductor, Flame retardent cables with reduced halogen evolution and smoke (FR-LSH), PVC insulated, PVC sheathed armoured cables confirming to IS: 1554 (Part-I).
4505
-
-
... More
Supply of 95 sq.mm, 4 core, 1.1 KV, aluminium conductor,Flame retardent cables with reduced halogen evolution and smoke (FR-LSH), PVC insulated, PVC sheathed armoured cables confirming to IS: 1554 (Part-I).
3271
-
-
... More
Supply of 185 sq.mm, 4 core, 1.1 KV, aluminium conductor, Flame retardent cables with reduced halogen evolution and smoke (FR-LSH), PVC insulated, PVC sheathed armoured cables confirming to IS: 1554 (Part-I).
1216
-
-
... More
Supply of 300 sq.mm single core, 1.1 KV, aluminium conductor, Flame retardent cables with reduced halogen evolution and smoke (FR-LSH), PVC insulated, PVC sheathed armoured cables confirming to IS: 1554 (Part-I).
480
-
-
... More
Supply of 300 sq.mm, 4 core, 1.1 KV, aluminium conductor, Flame retardent cables with reduced halogen evolution and smoke (FR-LSH), PVC insulated, PVC sheathed armoured cables confirming to IS: 1554 (Part-I).
1318
-
-
... More
Supply of 400 sq.mm single core, 1.1 KV, aluminium conductor, Flame retardent cables with reduced halogen evolution and smoke (FR-LSH), PVC insulated, PVC sheathed armoured cables confirming to IS: 1554 (Part-I).
320
-
-
... More
Supplying and installing double wall corrugated pipes (DWC) of HDPE (IS-14930 Part-II marked) for cable laid under ground with necessary material and at required depth upto 90 cm below road/ground surcafe, including excavation, back filling with excavated material, ramming and making the surface good : 50.00 mm outside dia.
5401
-
-
... More
Supplying and installing double wall corrugated pipes (DWC) of HDPE (IS-14930 Part-II marked) for cable laid under ground with necessary material and at required depth upto 90 cm below road/ground surcafe, including excavation, back filling with excavated material, ramming and making the surface good : 90.00 mm outside dia.
12310
-
-
... More
Supplying and installing double wall corrugated pipes (DWC) of HDPE (IS-14930 Part-II marked) for cable laid under ground with necessary material and at required depth upto 90 cm below road/ground surcafe, including excavation, back filling with excavated material, ramming and making the surface good : 110.00 mm outside dia.
1216
-
-
... More
Supplying and installing double wall corrugated pipes (DWC) of HDPE (IS-14930 Part-II marked) for cable laid under ground with necessary material and at required depth upto 90 cm below road/ground surcafe, including excavation, back filling with excavated material, ramming and making the surface good : 180.00 mm outside dia.
1248
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required : Upto 35 sq. mm
5401
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required : Above 35 sq. mm and upto 95 sq. mm.
3337
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required : Above 95 sq. mm and upto 185 sq. mm.
608
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required : Above 185 sq. mm and upto 400 sq. mm.
684
-
-
... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushnioning, protective covering and refilling the trench etc as required : Above 35 sq. mm and upto 95 sq. mm.
8333
-
-
... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushnioning, protective covering and refilling the trench etc as required : Above 95 sq. mm and upto 185 sq. mm.
608
-
-
... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushnioning, protective covering and refilling the trench etc as required : Above 185 sq. mm and upto 400 sq. mm.
1204
-
-
... More
Supply, installation, testing & commissioning of 11 KV Under-Ground XLPE armoured cable 3x185 sq.mm.
2665
-
-
... More
Providing & making cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 11 KV 3 core XLPE aluminium conductor cable as required as per specification and as per accepted standard including connection testing complete. Heat shrinkable jointing kit 11 KV XLPE, 3 core cable O.D. termination for 3 x 120-185 sq. mm.
2
-
-
... More
Providing & making cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 11 KV 3 core XLPE aluminium conductor cable as required as per specification and as per accepted standard including connection testing complete. Heat shrinkable jointing kit 11 KV XLPE, 3 core cable I.D. termination for 3 x 120-185 sq. mm.
14
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm.
2665
-
-
... More
Distribution Transformer (DTR) Fencing : Fencing of DTR Urban Area
3
-
-
... More
Concreting of structures & foundation (1:3:6) for transformer
19
-
-
... More
Supply, installation, testing & commissioning of Distribution Transformer, 630 KVA - 11/0.433 KV rating copper wound BIS level-I
1
-
-
... More
Supply, installation, testing & commissioning of Distribution Transformer (DTR) 11/0.4 KV Conventional 3 Star Rating 315 KVA (Copper Wound)
2
-
-
... More
Supply, Installation, Testing & Commissioning of 11 KV, 1250-630Amp, 26.3 KA for 3 sec. indoor type VCB panel with all protection relay, C.Ts, P.Ts, Meters etc. 1250 Amp. VCB as incommer - 2 Nos., Bus PT - 2 Nos., 630 Amp VCB as outgoing - 6 Nos. and as per technical specifications mentioned in tender document
1
-
-
... More
Supply, installation, testing & commissioning of 30 Volts 100 AH Lead Acid Battery
1
-
-
... More
Supply, installation, testing & commissioning of Battery charger 230 V AC input 20 Amp., 30 V DC output solid state type
1
-
-
... More
Supply, Installation, Testing & Commissioning of outdoor type energy meter panel with following arrangement and technical specifications as mentioned in tender document (For H-type quarters). Incomer: 32 Amp 4 pole 36 KA Outgoing Feeders: 32 Amp 4 pole 25 KA - 05 Nos.
46
-
-
... More
Supply, Installation, Testing & Commissioning of outdoor type energy meter panel with following arrangement and technical specifications as mentioned in tender document (For G-type quarters). Incomer: 63 Amp 4 pole 36 KA Outgoing Feeders: 40 Amp 4 pole 25 KA - 05 Nos.
24
-
-
... More
Supply, Installation, Testing & Commissioning of outdoor type energy meter panel with following arrangement and technical specifications as mentioned in tender document (For F-type double story quarters). Incomer: 100 Amp 4 pole 36 KA Outgoing Feeders: 63 Amp 4 pole 25 KA - 05 Nos.
10
-
-
... More
Supply, Installation, Testing & Commissioning of outdoor type Feeder panel with following arrangement and technical specifications as mentioned in tender document (Near H-type qtrs from H-269 to H-348). Incomer: 400 Amp 4 pole 50 KA Outgoing Feeders: 63 Amp 4 pole 36 KA - 22 Nos.
1
-
-
... More
Supply, Installation, Testing & Commissioning of outdoor type Feeder panel with following arrangement and technical specifications as mentioned in tender document (Near H-type qtrs from H-349 to H-412 & H-445 to H-452).Incomer: 400 Amp 4 pole 50 KAOutgoing Feeders: 63 Amp 4 pole 36 KA - 20 Nos.
1
-
-
... More
Supply, Installation, Testing & Commissioning of outdoor type Feeder panel with following arrangement and technical specifications as mentioned in tender document (Near H-type from H-413 to H-444). Incomer: 250 Amp 4 pole 50 KA Outgoing Feeders: 63 Amp 4 pole 36 KA - 10 Nos.
1
-
-
... More
Supply, Installation, Testing & Commissioning of outdoor type transformer feeder panel with following arrangement and technical specifications as mentioned in tender document (Near H-type). Incomer: 630 Amp 4 pole 50 KA Outgoing Feeders: 400 Amp 4 pole 36 KA - 02 Nos. & 250 Amp 4 pole 36 KA - 01 No
1
-
-
... More
Supply, Installation, Testing & Commissioning of outdoor type Feeder panel with following arrangement and technical specifications as mentioned in tender document (Near G-type from G-191 to G-262). Incomer: 630 Amp 4 pole 50 KA Outgoing Feeders: 100 Amp 4 pole 36 KA - 20 Nos.
1
-
-
... More
Supply, Installation, Testing & Commissioning of outdoor type Feeder panel with following arrangement and technical specifications as mentioned in tender document (Near G-type from G-263 to G-286, VIP GH). Incomer: 250 Amp 4 pole 50 KA Outgoing Feeders: 100 Amp 4 pole 36 KA - 08 Nos.
3
-
-
... More
Supply, Installation, Testing & Commissioning of outdoor type transformer feeder panel with arrangement and technical specifications mentioned in tender document (Near G-type). Incomer: 630 Amp 4 pole 50 KA Outgoing Feeders: 630 Amp 4 pole 36 KA - 01 No & 250 Amp 4 pole 36 KA - 01 No
1
-
-
... More
Supply, Installation, Testing & Commissioning of outdoor type Feeder panel with following arrangement and technical specifications as mentioned in tender document (Near proposed F-type, Admin Building, Punasa Field Hostel). Incomer: 400 Amp 4 pole 50 KA Outgoing Feeders: 100 Amp 4 pole 36 KA - 08 Nos.
3
-
-
... More
Supply, Installation, Testing & Commissioning of outdoor type Feeder panel with following arrangement and technical specifications as mentioned in tender document (Near double story F-type). Incomer: 250 Amp 4 pole 50 KA Outgoing Feeders: 100 Amp 4 pole 36 KA - 06 Nos.
1
-
-
... More
Supply, Installation, Testing & Commissioning of outdoor type Feeder panel with following arrangement and technical specifications as mentioned in tender document (For proposed field hostel & Punasa field hostel). Incomer: 400 Amp 4 pole 50 KA Outgoing Feeders: 100 Amp 4 pole 36 KA - 06 Nos.
2
-
-
... More
Supply, Installation, Testing & Commissioning of outdoor type feeder & energy meter panel with following arrangement and technical specifications as mentioned in tender document (For F-type single story quarters, VIP GH, Punasa & Ajnal FH). Incomer: 125 Amp 4 pole 36 KA Outgoing Feeders: 63 Amp 4 pole 25 KA - 06 Nos.
13
-
-
... More
Supply, Installation, Testing & Commissioning of outdoor type feeder & energy meter panel with following arrangement and technical specifications as mentioned in tender document (For Hospital & community hall). Incomer: 125 Amp 4 pole 36 KA Outgoing Feeders: 100 Amp 4 pole 25 KA - 03 Nos.
1
-
-
... More
Supply, Installation, Testing & Commissioning of outdoor type feeder & energy meter panel with arrangement and technical specifications mentioned in tender document (For E-3, E-4, E-5 & E-6). Incomer: 250 Amp 4 pole 36 KA Outgoing Feeders: 63 Amp 4 pole 25 KA - 05 Nos.
1
-
-
... More
Supply, Installation, Testing & Commissioning of outdoor type feeder & energy meter panel with following arrangement and technical specifications as mentioned in tender document (For VIP, E-1, E-2 & D-1). Incomer: 400 Amp 4 pole 50 KA Outgoing Feeders: 125 Amp 4 pole 36 KA - 06 Nos.
1
-
-
... More
Supply, Installation, Testing & Commissioning of outdoor type transformer feeder panel with following arrangement and technical specifications as mentioned in tender document (Near D-type). Incomer: 800 Amp 4 pole 50 KA Outgoing Feeders: 400 Amp 4 pole 36 KA - 05 Nos., 250 Amp 4 pole 36 KA - 03 Nos. & 125 Amp 4 pole 36 KA - 04 Nos.
1
-
-
... More
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal / coke and salt as required.
387
-
-
... More
Providing & fixing 25mm x 5mm G.I. strip in 40mm dia G.I. pipe FRL Som earth electrode including connection with G.I. nut, bolt, spring washer, excavation and re-filling etc. as required.
929
-
-
... More
Supplying and laying 25mm x 5mm G.I. strip at 0.50 meter below ground as strip earth electrode including connection / terminating with G.I. nut, bolt, spring washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
1930
-
-
... More
Providing and fixing 25mm x 5mm G.I. strip on surface or in recess for connections etc. as required.
1003
-
-
... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
1712
-
-
... More
Supplying and fixing cable route marker round / square size 100mm, 5mm thick G.I. plate duly bolted / welded on 35mm x 35mm x 5mm angle iron 60cm long including excavation, grouting in cement concrete 1:2:4 (1 cement and 2 coarse sand & 4 graded stone aggregate 20mm nominal size) foundation of size 20cm x 20cm x 30cm duly embedded in ground 30cm depth or as required.
523
-
-
... More
Supplying & fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V, 15 A kit kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2 core, 16 sqmm PVC aluminium cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.
137
-
-
... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) : 4 way (4 + 12), Double door.
330
-
-
... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. : 40 Amps
330
-
-
... More
CIVIL WORKS
-
-
-
... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge : All kinds of soil
52.84
-
-
... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
65.96
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : "1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size).
13.57
-
-
... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
43.34
-
-
... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
2.88
-
-
... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
21.89
-
-
... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. : Thermo-Mechanically Treated bars of grade Fe-500D or more.
6811.2
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete
16.8
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts
62.4
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers
48.56
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform
119.27
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
86.88
-
-
... More
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
5.66
-
-
... More
Brick work with bricks of kumhar bricks in super structure above plinth level upto floor five level in 1:6 ( 1Cement : 6 Coarse) etc. all works complete as per works specification and in accordance with the direction of Engineer-In-Charge.
15.95
-
-
... More
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
119.27
-
-
... More
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
93.94
-
-
... More
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
214.44
-
-
... More
Neat cement punning.
52.8
-
-
... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
57
-
-
... More
Providing and fixing factory made ISI marked steel glazed doors, windows and vintilators, side/top/centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. Complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming cost of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment.)
73.74
-
-
... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes.
6
-
-
... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required : In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
1625
-
-
... More
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
214.44
-
-
... More
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour : Two coats
213.21
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
43
-
-
... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
120.41
-
-
... More
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
205.2
-
-
Evaluation Notes How It Works ?