National Handloom Development Corporation Limited Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
National Handloom Development Corporation Limited - NHDC Tender
Eprocure
Opening Date15 Apr 2020
Closing Date9 Jul 2020
Tender Amount₹ 5,64,000
Costs
EMD
₹ 12,000Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_NHDC_555378_1Bid Award Id
ViewTender No
NHDC/2/C/1268/20/1018-1031 dated 11/04/2020Tender Authority
National Handloom Development Corporation Limited ViewPurchaser Address
-Website
http://https://www.nhdc.org.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
SUPPLY OF LV SWITCHGEAR CONTROL ELEMENTS FOR INDIRA SAGAR POWER STATION, NARMADA NAGAR, DISTRICT- KHANDWA (M.P.)
SUPPLY OF LV SWITCHGEAR CONTROL ELEMENTS FOR INDIRA SAGAR POWER STATION, NARMADA NAGAR, DISTRICT- KHANDWA (M.P.)
BOQ Items
Rotary Switch
2 way with OFF, 4 positions 90 °,
Type: maintained, 10 A/250 V AC
No. of Pole: 4
Indicating Plate Size 75×75 mm
Panel Mounting, Grey F.P and Black Knob
3
-
-
Breaker Control Switch
Spring Return, 4 Electrical Ways,
Pistol Grip Handle, Spring Return
Angle of Throw: 90 °
Breaking Capacity: 32 Amp DC
4
-
-
Rotary Switch
2 way NO OFF, 2 position 90 °
Type: maintained, 16A AC
No. of Pole: 2
Indicating Plate Size 75×75 mm
Panel Mounting, Grey F.P and Black Knob
5
-
-
Industrial power socket board with mcb as a switch of rating 16 A Material : fiber protection: IP-55
10
-
-
Industrial power socket board with mcb as a switch of rating 16 A Material : fiber
10
-
-
Moulded case circuit breaker
No. of Pole: Four
Current rating : 32 Amp
Operating Voltage: 415 V AC, 50 Hz ( or better)
Ics: 50KA ( or better); Ui : 500 V AC (or better); Utilization curve: A
Along with 1 C/O contact
Adjustable thermal setting
3 position toggle ( Open-Trip-Close) and provision for test check Tripping mechanism
1
-
-
Moulded case circuit breaker
No. of Pole: Three
Current rating : 63 Amp
Operating Voltage: 415 V AC, 50 Hz ( or better)
Ics: 70 KA ( or better); Ui : 500 V AC (or better); Utilization curve: A
Adjustable Thermal setting 3 position toggle ( Open-Trip-Close) and provision for test check Tripping mechanism
2
-
-
Moulded case circuit breaker
No. of Pole: Four
Current rating : 100 Amp
Operating Voltage: 415 V AC, 50 Hz ( or better)
Ics:50KA ( or better); Ui : 1000 V AC (or better); Utilization curve: A
Along with spreader
Along with 1 C/O contact
Adjustable Thermal setting
3 position toggle ( Open-Trip-Close) and provision for test check Tripping mechanism
4
-
-
Moulded case circuit breaker
No. of Pole:Four
Current rating : 125Amp
Operating Voltage: 415 V AC, 50 Hz ( or better)
Ics:36KA ( or better); Ui : 500 V AC (or better); Utilization curve: A
Along with spreader
Along with 1 C/O contact
Adjustable Thermal setting
3 position toggle ( Open-Trip-Close) and provision for test check Tripping mechanism
1
-
-
Moulded case circuit breaker
No. of Pole: Four
Current rating : 200 Amp
Operating Voltage: 415 V AC, 50 Hz ( or better)
Ics:50KA ( or better); Ui : 1000 V AC (or better); Utilization curve: A
Along with 1 C/O contact
Adjustable thermal setting
3 position toggle ( Open-Trip-Close) and provision for test check Tripping mechanism
4
-
-
MCB Single Pole
Current Rating: 16 Amp
Voltage rating : 415 V AC/ 230 VAC, 50 Hz
Characteristic Curve: C
Breaking Capacity: 10 KA (atleast)
Mounting: DIN rail 35mm for MCB
30
-
-
MCB Double Pole
Current Rating: 16 Amp
Voltage rating : 415 V AC/ 230 VAC, 50 Hz
Characteristic Curve: B
Breaking Capacity: 10 KA (atleast)
Mounting: DIN rail 35mm for MCB
Along with auxiliary contact: 1NO+1NC
4
-
-
MCB Double Pole
Current Rating: 16 Amp
Voltage rating : 220V DC
Characteristic Curve: C
Breaking Capacity: 10 KA (atleast)
Mounting: DIN rail 35mm for MCB
Along with auxiliary contact: 1NO+1NC
3
-
-
MCB Single Pole
Current Rating: 32 Amp
Voltage rating : 415 V AC/ 230 VAC, 50 Hz
Characteristic Curve: C
Breaking Capacity: 10 KA (atleast)
Mounting: DIN rail 35mm for MCB
3
-
-
MCB Double Pole
Current Rating: 32 Amp
Voltage rating :415 V AC, 50 Hz
Characteristic Curve: C
Breaking Capacity: 10 KA (atleast)
Mounting: DIN rail 35mm for MCB
8
-
-
MCB Three Pole
Current Rating: 32 Amp
Voltage rating : 415 V AC, 50 Hz
Characteristic Curve: C
Breaking Capacity: 10 KA (atleast)
Mounting: DIN rail 35mm for MCB
Along with auxiliary contact: 1NO+1NC
3
-
-
HRC Fuse
Rating: 4 Amp
NS type ; Offset Bladed
Voltage rating (applicable) : 415 V AC / 220 V DC (at least)
Breaking capacity: 70 KA ( or better)
Category: gG
20
-
-
HRC Fuse
Rating: 10 Amp
NS type ; Offset Bladed
Voltage rating (applicable) : 415 V AC / 220 V DC (at least)
Breaking capacity: 70 KA ( or better)
Category: gG
5
-
-
Single Phase Preventor
Electronic type suitable for reverse phasing, unbalance supply
Auto Reset type
Supply Voltage: 415 V AC, 50 Hz
Contact: 1 NO
Contact rating: 5 Amp ( at 230 V AC)
3
-
-
Pump Protection Relay along with cureent sensor
Current Sensor:120A
Protection: Overload, Phase Failure, Unbalancing, Dry Run Auto/Mannual Reset
Supply Voltage: 415 V AC, 50 Hz
Contact: 2 CO
Contact rating: 5 Amp ( at 230 V AC)
1
-
-
Thermal Overload
Range : 2.5-4 Amp
having 1NO+1NC aux contact
Mounting: Contactor Mounting Note: Upper range of current to be included
2
-
-
Thermal Overload
Range : 6-9.3Amp
having 1NO+1NC aux contact
Mounting: Independent Mounting
Note: Upper range of current to be included
1
-
-
Thermal Overload
Range : 10-16 Amp
having 1NO+1NC aux contact
Mounting: Independent Mounting
Note: Upper range of current to be included
2
-
-
Thermal Overload
Range : 18-25 Amp
having 1NO+1NC aux contact
Mounting: Independent
Note: Upper range of current to be included
2
-
-
Power Contactor
No. of Pole: 3
Coil Volatge: 230 to 240 V AC, 50 Hz
Current rating Ie AC 3 at 415 V, 50 Hz : 45 Amp ( at least)
Auxililary Contacts combination to be present apart from power contact pole: 4NO + 4NC
12
-
-
Single door encloser, Size : 500x600x200mm, 1.6mm CRCA sheet steel , powder coated, paint-RAL7032, with inside mounting plate and top and bottom removable gland plate.
5
-
-
Float type level switch with displacer (vertical mounting) contact rating 10A ,230V AC, 50 HZ, cable length : 5 mtr, (suitable for oil)
10
-
-
Moulded case circuit breaker
No. of Pole: Four
Current rating : 630 Amp
Operating Voltage: 415 V AC, 50 Hz ( or better)
Ics:50KA ( or better); Ui : 1000 V AC (or better); Utilization curve: A
Along with 1 C/O contact
Adjustable thermal setting
3 position toggle ( Open-Trip-Close) and provision for test check Tripping mechanism
1
-
-
Thermal Overload
Range : 37.6-60 Amp
having 1NO+1NC aux contact
Mounting:Independent
Note: Upper range of current to be included
1
-
-
Power Contactor
No. of Pole: 3
Coil Volatge:220 V DC
Current rating Ie AC 3 at 415 V, 50 Hz : 25 Amp ( at least)
Auxililary Contacts combination to be present apart from power contact pole: 1NO+1NC With mechanical latch
3
-
-
Power Contactor
No. of Pole: 3
Coil Volatge: 230 to 240 V AC, 50 Hz
Current rating Ie AC 3 at 415 V, 50 Hz : 75 Amp ( at least)
Auxililary Contacts combination to be present apart from power contact pole: 2NO+2NC
4
-
-
Power Contactor Kit for the contactor 3TF48
2
-
-
Power Contactor Kit for the contactor 3TF50
3
-
-
Power Contactor Kit for the contactor MNX70
2
-
-
Power Contactor Kit for the contactor MNX110
2
-
-
Add on Block 1NC, Model-NHD
10
-
-
Add on Block 1NO, Model-3TX4010-2A
20
-
-