MP State Livestock And Poultry Development Corporation Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
MP State Livestock And Poultry Development Corporation - MPLPDC Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Jul 2023
Closing Date4 Aug 2023
Tender Amount₹ 6,64,302
Costs
EMD
₹ 13,500Document Cost
₹ 2,000Tender Fee
₹ 295
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MLPDC_295249_1Bid Award Id
ViewTender No
214/206/Elec/CBF/Raton/2023-24Tender Authority
MP State Livestock And Poultry Development Corporation ViewPurchaser Address
-Website
http://https://mptenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying and erection of stay set complete with 19/20mm.dia 1.8 metre long stay rod, turn buckle, ancher plate of size 300mm x 300mm x 7.5mm, thimble, stay clamps, bow tightener, 7/4.00 dia G.I. stay wire etc. in cement concrete M-10 (1 Cement : 3 Coarse and : 6 granded stone aggregate 40mm nominal size) foundation including excavation and back refilling etc. as required.(SOR I.No. 42.29)
3
10800
3600
Supply, fabrication and erection of Angle/Chanel/Flat iron fitting for over head line & sub-station etc such as 'D' bracket, cross arms, top clamp, 'V' cross arms, Back/Support clamps or other similar work etc. including nut bolts of required size, making holes, fabrication, welding, cutting, etc. and painting with one coat of red oxide paint & two coat of aluminium paint as required as per specification.(SOR I.No. 42.42)
50
5250
105
Painting of poles Prima coat over new steel and other metallicsurface with red oxide zinc chromide paint complete with supply of material labour etc.including preparation of surface.SOR I.No 34.4.2
50
4800
96
Prima coat with aluminium paint, brushing
complete with material and labour including
preparation of surface SOR I.No 34.4.3
50
3800
76
Supply, laying and fixing of G.I. earth coil
of 4mm dia G.I. wire having 120 turns of
nearly 50mm dia. and 3 mt. long tail in
existing pit duly earthed with pole etc
complete as required as per specification.(SOR I.No. 42.68)
11
3223
293
Supply of XLPE insulated power cable
(conforming IS-7098 Part-I) 1100 Volt
grade, 1 core/2 core/3½ core/4 core ISI
marked with alu. stranded /solid conductor25 sq. mm.3.5 core(SOR I.No. 41.1.8.1)
500
115000
230
Laying of one number armoured /
unarmoured power cable 1:1 KV grade of
size not exceeding 25 sq. mm in the existing
RCC hume/stone ware/G.I. pipe/surface in
existing trench as required.(SOR I.No. 41.45)
500
12500
25
Supplying, erecting and testing of approved make exhaust fanheavy duty with mounting frame, blades AC 230-250complete connection and including, frame bolt/anchor holefasteners etc. complete finished and as required.(SOR I.No. 30.6.4)
2
17404
8702
Supply and fixing of GI sheet 24 SWG exhaust fan louversincluding grouting bolt, nut, & finishing etc. on existing hole tocomplete the job as mentioned below :-(SOR I.No. 32.16.4)
2
5490
2745
Point wiring (excluding metallic switchbox & sheet but including switches,sockets, lamp holders/ceiling roses etc)with 1.5sq. mm. PVC insulated cableFRLS with copper multi strand
conductor ISI marked in surface rigidP.V.C. conduit (MMS) ISI marked ofsuitable size and 1.5sq. mm. PVC FRLSinsulated copper earth continuityconductor of green colour inside conduitetc. as required as per specification for :- Primary short point (SOR I.No. 3.1.1.1)
5
2040
408
Point wiring (excluding metallic switchbox & sheet but including switches,sockets, lamp holders/ceiling roses etc)with 1.5sq. mm. PVC insulated cableFRLS with copper multi strand
conductor ISI marked in surface rigidP.V.C. conduit (MMS) ISI marked ofsuitable size and 1.5sq. mm. PVC FRLSinsulated copper earth continuityconductor of green colour inside conduitetc. as required as per specification for :-Primary medium point (SOR I.No. 3.1.1.2)
2
1458
729
Point wiring (excluding metallic switchbox & sheet but including switches,sockets) for 3 pin 6 Amp. Socket outletpoint with 1.5sq. mm. PVC insulatedcable FRLS with copper multi strand
conductor ISI marked in surface rigidP.V.C. conduit (MMS) ISI marked ofsuitable size and 1.5sq. mm. PVCinsulated copper earth continuityconductor of green colour inside conduitwith required materials as per
specification on same board (SOR I.No. 3.2)
5
1325
265
Wiring for circuit wiring with PVCinsulated cable FRLS with copper multistrand conductor ISI marked in surfacerigid P.V.C. conduit (MMS) of ISImarked suitable size etc. as required as
per specification 2x2.5 Sq.mm.(SOR I.No. 3.3.1)
50
6100
122
Point wiring (excluding metallic switch box & sheet) for 3Pin 16 Amp. socket outlet point with 4sq. mm. PVCinsulated cable FRLS with copper multi strand conductorISI marked in surface rigid P.V.C. conduit (MMS) ISImarked of suitable size etc. with 20/16 Amp. F.T. switch &socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq.
mm. PVC insulated FRLS copper earth continuityconductor of green colour inside conduit, screwlessconnector for joints as per specification for :-Short point(SOR I.No. 8.1.1.1)
5
4225
845
Supply and erection of approved make safe
earthing electrode consisting pipe-in-pipe
technology as per IS 3043-1987 made of
corrosion free G.I. pipes with constant
ohmic value surrounded by highlyconductive compound with high chargedissipation suitable for effective andmaintenance free earthing in earth pit ofminimum bore dia. 150mm size, asmentioned below :With 2 metre G.I. pipes having outer pipedia of 50mm having 80-200 microngalvanizing, Inner pipe dia. of 25mm having200-250 micron galvanizing, connection
terminal dia. of 12mm in nominal soil with25 kg (one Bag) back filling bentonitecompound UL listed and confirm to relevantInternational/Indian standards around electrode upto ground level.(SOR I.No. 37.40.1)
2
17944
8972
Supply of ISI marked and accepted standard of miniaturecircuit breaker (MCB) of 'C' series with short circuitindication, suitable for 240/415 Volts,50 Cycle, 10kA/15 kA Value AC supply conforming to IS : 8828 :1996, IEC : 60898 :2002 & 60947-2 but withoutenclosures :-Four pole MCB FP 50Amp to 63 Amp 10kA rating(sor-27.8.4.4)
5
13975
2795
Supplying and fixing of approved make modular type PVCbox minimum depth 40mm and minimum thickness 2mmwith modular base and cover plate including fixing onsurface etc. as required for:-6 Module PVC box(SOR I.No. 18.3.4)
2
508
254
Supply of ISI marked and accepted standard of miniaturecircuit breaker (MCB) of 'C' series with short circuitindication, suitable for 240/415 Volts,50 Cycle, 10kA/15 kA Value AC supply conforming to IS : 8828 :1996, IEC : 60898 :2002 & 60947-2 but withoutenclosures :-spn MCB DP 6Amp to 32Amp 10kA rating1ating(sor-27.8.2.2)
4
3548
887
Supply of ISI marked and accepted standard of miniaturecircuit breaker (MCB) of 'C' series with short circuitindication, suitable for 240/415 Volts,50 Cycle, 10kA/15 kA Value AC supply conforming to IS : 8828 :1996, IEC : 60898 :2002 & 60947-2 but withoutenclosures :-SP 6Amp to 32Amp 10kA rating (sor-28.8.1.2)
5
1315
263
Supply of approved make powder coated sheet steelencloser SPN MCB DB inclusive of busbar, neutral bar,earth bar, connection copper wire not less than 16 sq.mm& two earth terminals etc. complete as perIS:13032(exclusive of MCB & isolator)-8 Way double door IP 43 protection (sor-27.11.5)
1
2127
2127
Supplying of approved make TPN MCB DB metal
double door IP 43 protection with provision for FPMCB/ Isolator/ RCCB/ RCBO as incomer and SP MCBsas outgoing inclusive of busbar, neutral bar, earth bar,connection copper wire not less than 16 sq.mm & twoearth terminals etc. complete as per IS:13032(exclusiveof MCB & isolator):4 Way (4+12) (sor-27.12.1))
2
10252
5126
Supply of ISI marked and approved make of mouldedcase circuit breaker (MCCB) suitable for 3 phase,3 pole,50 Hz, 415 Volts, AC supply with respective interruptingcapacity (KA) at 415 Volts cited against their rangestandard conforming to IS – 8828 MCCB 25kA current rating, 3P -25 to 100Amp & 80% -100% adjustable (sor-27.1.3)
1
7369
7369
Supplying and fixing flood light with high power LED of 3 to 6 Watteach assembled on single MCPCB and additional unique peanut lens
on each LED, system lumens output withefficacy120 lm/Watt.luminiare having color temp upto 6500K & 50000 hrs. burning life
with minimum @ L 70, The colour rendering index of LED lightshould be more than 70. Luminiare comprises of driver, PF 0.95 &
surge protection 10KV. Housing made of pressure die castaluminium with heat resistant flat glass, IP65 protection. SubmissionLM 79-08/IS16106 (2012),IEC60598,IEC61347i/c connection wire,testing etc. to complete the job.60Watt, color temp 3000-6500k as required. (sor-31.14.3)
4
31488
7872
Supplying and fixing flood light with high power LED of 3 to 6 Watteach assembled on single MCPCB and additional unique peanut lens
on each LED, system lumens output withefficacy120 lm/Watt.luminiare having color temp upto 6500K & 50000 hrs. burning life
with minimum @ L 70, The colour rendering index of LED lightshould be more than 70. Luminiare comprises of driver, PF 0.95 &
surge protection 10KV. Housing made of pressure die castaluminium with heat resistant flat glass, IP65 protection. SubmissionLM 79-08/IS16106 (2012),IEC60598,IEC61347i/c connection wire,testing etc. to complete the job.150Watt, color temp 3000-6500k as required. (sor-31.14.6)
6
129432
21572
Industrial hooter: Providing & fixing of industrial
hooter speaker horn type ABS body with
working AC Voltage 220V A.C./24V D.C.
current consumption, sound output 120 DB,
material M.S. sheet. (sor-50.9)
4
8032
2008
Supply and fixing street light with high power LED of 3 to 6 Watteach on existing bracket assembled on single MCPCB and additional
unique peanut lens on each LED, system lumens output withefficacy120 lm/Watt. luminiare having color temp upto 6500K &
50000 hrs. burning life with minimum @ L 70, The colour renderingindex of LED light should be more than 70. Luminiare comprises of
driver, PF 0.95 & surge protection 10KV. Housing made of pressuredie cast aluminium with heat resistant flat glass, IP65 protection.
Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347 i/cconnection wire, testing etc. to complete the job.60Watt, color temp 3000-6500k as required.(sor-31.13.2)
5
48955
9791
Supplying, erection and testing of approved make electricCeiling fan of double ball bearing complete with standarddown rod, canopy, hanging shackle, Aluminium blades,without regulator, A.C. 230-250 volts including connectionswith all necessary material complete of approved as requiredconfirming to IS :374/2019 with upto date amendmentsCeiling Fan (ISI marked)-1200 mm Sweep, with minimum airdelivery 210 m³/min and service value
≥4.00 as per BEE..(sor-30.1.2)
5
11460
2292
Supply and fixing of approved make step type modularelectronic fan regulator including connection etc. as required on existing board 100 Watt(2 module) (sor-29.25.2)
5
2420
484
Supply and fixing Led tube rod comprising of LED tube with nonintegral/integral driver, upto 6500K color temp having 40000 burninghrs life with minimum @ L 70, system lumen output should beminimum with system efficacy 100 lm/Watt. LED driver PF 0.95& THD 20%. The colour rendering index of LED light should be
more than 70. Submission LM 79-08/IS16106 (2012), IEC60598,IEC61347i/c connection wire, testing etc. to complete the job. (SOR I.No. 31.3.4)
5
3910
782
Supply, installation, testing and
commissioning of astro-time switch based on
astro program i.e. calculation of sunrise and
sunset times through date, time and Indian
PIN codes. It shall have an option of astro ON
period override by time switch and Offset
function which allows programming of
switching times offset from the astronomic
time. The 230 V AC operated astro time
switch shall have an operating range of
96…253V AC with 1 NO, 16 A, AgSnO2
contact material with starting current of 120A
and 1 CO cadmium free contacts, it shall have
LCD status indication with back light display
along with internal easily replaceable battery
on the front side for set-up and programming.
The electrical life at rated load AC1 shall be 1
lakh cycles and shall work at an ambient
temperature of -20 to +50 deg C. It shall have
a dielectric strength between supply and open
contacts of 4000V AC, between open contacts
1000V AC respectively and rated impulse to complete the job. (SOR I.No. 52.3.1)
2
19048
9524
Supply, installation, testing and
commissioning of 230 V AC operated LDR
shall have an operating range of 96…253V
AC with 1 NO, 16 A, AgSnO2 contact
material with starting current of 120A and
light dependent relay with a lux sensitivity
adjustment of 1 to 80 lux shall operate on 230
V AC with an operating voltage range of 0.8
to 1.1 times that of nominal voltage. The
contacts shall be rated for 16 Amp, cadmium
free along with the cadmium free light sensor
and shall operate at an ambient temperature of
-30 deg C to + 70 deg C. The electrical
service life of LDR shall be 1 lakh switching
cycles at full load. The dielectric strength
between open contacts should be 1000 V AC
and conducted disturbance immunity i.e.
surge (1.2/50μs) on L and N (differential
mode) of 4 kV. The LDR shall have necessary
approvals like CE, GOST and IMQ and shall
be IP 54 protected and able to switch phase
and neutral lines for LED lamp load of 400 (SOR I.No. 52.1.1)
2
14278
7139
Point wiring (excluding metallic switchbox & sheet but including switches,sockets) for 3 pin 6 Amp. Socket outletpoint with 1.5sq. mm. PVC insulatedcable FRLS with copper multi strand
conductor ISI marked in surface rigidP.V.C. conduit (MMS) ISI marked ofsuitable size and 1.5sq. mm. PVCinsulated copper earth continuityconductor of green colour inside conduitwith required materials as per
specification on same board (SOR I.No. 3.2)
5
1325
265
Supplying of pre stressed cement concrete (PCC) poleconforming to IS: 785 at work site including required transportation.PCC pole 9.1 meter Long 280 kg (SOR I.No. 42.4.2)
5
25495
5099
Erection of R.C.C./P.C.C. pole of length 8 meters butnot exceeding 11 meters in brick ballast and ramming the foundation including excavation and refilling etc.as required.(SOR I.No. 42.21)
5
11410
2282