MP State Livestock And Poultry Development Corporation Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
MP State Livestock And Poultry Development Corporation - MPLPDC Tender
Civil Works Others
Coronavirus COVID 19
Eprocure
Opening Date3 Aug 2019
Closing Date24 Aug 2019
Tender Amount₹ 22,32,000 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 22,500Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_MLPDC_43078_1Bid Award Id
ViewTender No
128/120/BMF/FeedGodown/2019-20Tender Authority
MP State Livestock And Poultry Development Corporation ViewPurchaser Address
-Website
http://https://mptenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Extra depth
41.47
-
47.7
... More
PCC M-10 blow footing
23.57
-
3427.2
... More
RCC M-20 upto plinth beam
46.54
-
4581.9
... More
Wall and column
9.47
-
4681.8
... More
Above plinth beam
39.59
-
4755.6
... More
Steel Reinforcement
11955
-
54
... More
Centering Upto plinth beam
126.72
-
156.6
... More
Wall and plinth beam
158.97
-
240.3
... More
Slab
223.21
-
237.6
... More
Lintels and beams
99.72
-
204.3
... More
Column
109.44
-
320.4
... More
Available excavated earth
76.03
-
64.8
... More
Supplying and filling in plinth
209.9
-
270
... More
Crusher stone dust / coarse sand under floors
30
-
604.8
... More
Brick work with well fly ash bricks 200 mm th.
31.4
-
4690.8
... More
Providing half brick masonary
23.22
-
626.4
... More
Extra for providing and placing in position 2 Nos. 8 mm dia M.S. bars at every third course of half brick masonry.
23.22
-
114.3
... More
12 mm thick plaster
144.97
-
110.7
... More
20 mm cement plaster of mix :
359.86
-
157.5
... More
6 mm thick plaster
215.76
-
86.4
... More
Providing and fixing chicken mesh
100.97
-
55.8
... More
Birla white / JK white putty 6mm+12mm plaster qty.
360.73
-
66.6
... More
Wall painting with plastic emulsion paint
360.73
-
57.6
... More
Acrylic smooth exterior paint
359.86
-
78.3
... More
Synthetic enamel
2.16
-
47.7
... More
Kota stone slab flooring over 20 mm Verandah
140.16
-
688.5
... More
Kota stone slabs 20 mm thick in risers of steps
4.84
-
668.7
... More
80 mm thick C.C. paver block of M-35 grade with approved colour, design and pattern.
71.52
-
756
... More
Supplying and fixing rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover.
8.7
-
1664.77
... More
M.S. grills 35 kg. per sqm for windows area.
75.6
-
81.9
... More
Aluminium work for doors, windows, ventilators and partitions. Weight 2 kg. per sqm.
4.32
-
339.3
... More
For shutters of doors, windows and ventilators
6.48
-
382.5
... More
Glazing in aluminium door, window, ventilator
2.16
-
764.1
... More
40 mm thick marble chips flooring.
150
-
449.1
... More
PLUMBING WORK
-
-
-
... More
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work : 15 mm dia nominal work
6
-
169.2
... More
25 mm dia nominal work
20
-
236.7
... More
32 mm dia nominal work
25
-
279
... More
50 mm dia nominal work
30
-
406.8
... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore
2
-
878.4
... More
Providing and fixing gun metal gate valve with brass lever handle of approved quality. 25 mm nominal bore
2
-
306.9
... More
32 mm nominal bore
2
-
377.1
... More
Providing and fixing PTMT bib cock of approved quality and colour. 15 mm nominal bore, 122mm long. Weighing not less than 99 gms.
20
-
187.2
... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement :5 sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 sand) 12mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay bricks of 25 kg /sqcm compressive strength.
4
-
824.4
... More
Providing and laying below ground unplasticised PVC pipe to with stand working pressure of 4 kg/cm2 soild waste pipes confirming to IS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving 10mm gap for thermal expansion all necessary fittings etc. complete. Excavation to be paid seperataly. 110 mm diameter OD
20
-
210.6
... More
160 mm diameter OD
30
-
429.3
... More
Providing and laying cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) all-round PVC. pipes including bed concrete as per standard design: 200 mm diameter PVC. Pipe
30
-
633.6
... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe
30
-
256.5
... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With well burnt bricks
4
-
7197.3
... More
Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 sand ) with precast R.C.C. vertical grating complete as per standard design:With well burnt bricks
4
-
4419
... More
Electric Work
-
-
-
... More
Point wiring (excluding metallic switch box & sheet but including switches,sockes,lamp,holders,ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :- Light Point / Fan Points a) Short Point
6
-
354.6
... More
b) Medium Point
12
-
603.9
... More
c) Long point
18
-
974.7
... More
3 pin 6 amp. socket outlet on separate board c) Long point
2
-
1072.8
... More
Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. Socket outlet point with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board .
2
-
256.5
... More
Wiring for circuit wiring with PVC insulated calbe FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size etc. as required as per specification. a) 2x2.5 sqmm.
25
-
105.3
... More
b) 4x2.5 sqmm.
40
-
158.4
... More
c) 6x2.5 sqmm.
50
-
202.5
... More
Point wiring (excluding metallic switch box & sheet ) for 3 Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Concealed rigid P.V.C Conduit (HMS) ISI Marked of suitable size etc. with 16 Amp. F.T. Switch & Socket / S.S.Combined 6/16 Amp. of ISI Marked and 4 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit as per specification for On separate Baord Long point
1
-
1737
... More
Long point - I
1
-
2370.6
... More
Supplying and fixing PVC conduit ISI marked along with the accessories in concealed system etc. as required PVC . Conduit 25 mm (HMS)
15
-
64.8
... More
Supplying and fixing of approved make modular type metal box with modular frame/ base plate and cover plate including fixing in concealed / surface excluding switch,socket etc. as required for:- 3 Module
4
-
187.2
... More
16 Module
2
-
478.5
... More
Supplying and drawing single core PVC insulated cable FR with copper multi strand conductor ISI marked in existing rigid PVC Casing-N-Capping / conduit in surface or concealed as per specification. 1 X 1.5 sq mm (c) 3 X 1.5 sq mm
50
-
45.9
... More
Supplying of approved make TPN MCB DB Metal Double Door IP 43 protection with provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP MCBs as outgoing inclusive of Bus bar, Neutral bar, Earth bar & two earth terminals etc. complete as per IS:13032( exclusive of MCB & isolator ): 4 way (4+12)
1
-
2375.1
... More
Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS : 8828 : 1996, IEC : 60898 :2002 but without enclosures :- Single Pole (SP) 6 amp. to 32 amp. rating
8
-
184.5
... More
For triple pole & Neutral (TPN) For 40 amps. rating oly.
1
-
1791.5
... More
Fixing of MCB /MCCB/ Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (Labour only ) MCB / Isolator SP/DP
8
-
9.9
... More
MCB /MCCB Isolator TP /TPN/FP
1
-
19.8
... More
Supplying, Fixing and Testing of Compact Fluorescent Lamp (CFL) with inbuilt electronic ballast ISI marked BC / ES cap of approved make as required as per specification 15 Watt
6
-
174.6
... More
Supply of XLPE Insulated power cable (confirming IS-7098 Part-I ) 1100 Volt grade, 1 core /2 core /3½ core/4 core ISI MARKED with Alu. Stranded /solid conductor Armoured 4 Core 16 sqmm. (XLPE)