MP State Livestock And Poultry Development Corporation Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

MP State Livestock And Poultry Development Corporation - MPLPDC Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date31 May 2022
Closing Date6 Jun 2022
Tender Amount₹ 2,08,36,000 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

  • EMD

    ₹ 2,08,000
  • Document Cost

    ₹ 15,000
  • Tender Fee

    ₹ 1,534

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed.. Ordinary rock

919.28

-

203

... More
Extra for every additional lift of 1.5 m or part thereof in excavation. (No extra lift is payable if work is done by mechanical means), Ordinary or hard rock.

192.76

-

53

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : With 40mm nominal size graded stone aggregateM-10 Nominal (Mix -1 Cement : 3 sand : 6 graded stone aggregate)

243.6

-

3808

... More
Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : M-20 Grade Concrete

416.66

-

5796

... More
Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and upto floor two level excluding cost of centering, shuttering, finishing and reinforcement: M-20 Grade Concrete

223.51

-

5865

... More
Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in beams, suspended floors, roofs having slope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement in concrete grade. M-20 Grade Concrete

31.47

-

6155

... More
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3. Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”) Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786

56037.5

-

62.9

... More
Centering and shuttering in cluding strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for concrete upto plinth level

981.45

-

190.6

... More
Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc.Up to plinth level.

2120.12

-

219

... More
Lintels, beams, girders, bressumers and cantilevers

28.3

-

356

... More
Columns, P i l l a r s , Piers, Abutments, Posts and Struts.

137.94

-

471.2

... More
Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

435.27

-

72

... More
Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete. With hard muram having CBR 12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm)

2291.59

-

300

... More
Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming consolidating in layers not exceeding 20cm in depth and dressing complete

296.59

-

672

... More
Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor II level in : having 50 kg / cm2 average compressive strength, Cement mortar 1:6 (1 cement : 6 sand)

136.21

-

5049

... More
12 mm cement plaster of mix : 1:4 (1 cement : 4 sand)

1941.08

-

149

... More
20 mm cement plaster of mix : 1:4 (1 cement : 4 sand)

1434.69

-

215

... More
Providing and fixing mesh in vertical and horizontal junction of RCC and brick/AAC work including scaffolding and all lead and lift etc. complete - G.I. chicken mesh as per ISI specification and in the required width with 50mm long Bombay nails before plastering upt 10 meter height.

215.21

-

62

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete. Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of APD/Chief Engineer will be required.

1409.08

-

74

... More
Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work

1409.08

-

64

... More
Finishing walls by any mechanical or manual means with water proofing cement paint of required shade: New work (Two or more coats applied @ 3.84 kg/10 sqm).

1434.69

-

48

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.

2141.37

-

53

... More
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. n gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

14266.35

-

85

... More
Steel work in built up M.S. tubular section (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes.

29757

-

126

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

1690.81

-

652

... More
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15- 18 microns using self-drilling/ self- tapping screws complete : Ridges plain (500 - 600mm).

152.6

-

649.8

... More
Gutter. (600 mm over all girth)

305.2

-

781

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This included jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer-in- Charge. External Work: 15 mm nominal outer dia .Pipes.

21

-

122

... More
25 mm nominal outer dia .Pipes.

99

-

185

... More
50 mm nominal outer dia .Pipes.

295

-

498

... More
Providing and fixing CPVC gate valve with knob of approved quality. 25 mm nominal bore

14

-

428

... More
50 mm nominal bore

14

-

749

... More
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gm, 15 mm nominal bore.

14

-

526

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement :5 sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :- With well burnt flyash bricks of 50 kg/sqm compressive strength.

14

-

870

... More
Providing and laying below ground unplasticised PVC pipe to with stand working pressure of 4 kg/cm2 soild waste pipes confirming to IS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving 10mm gap for thermal expansion all necessary fittings etc. complete. Excavation to be paid seperataly. 160 mm diameter OD (min. wall thickness 4.0mm)

70

-

477

... More
Providing and laying cement concrete 1:3:6 (1 cement: 3 sand: 6 graded stone aggregate 20 mm nominal size) all-round PVC. pipes including bed concrete as per standard design: 160 mm diameter PVC. Pipe

70

-

704

... More
Providing and laying non- pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 sand) including testing of joints etc. complete : 300 mm dia. R.C.C. pipe

56

-

480

... More
Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 sand) including 500x450 mm precast R.C.C. horizontal grating with frame complete as per standard design : With fly ash bricks 100 key/cm2 strangth

14

-

7197.3

... More
Boring/drilling bore well of required dia perfectly vertical to receive casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer–in-Charge, upto 90 metre depth below ground level. All types of soil upto 90 metre depth. 200 mm dia.

1.5

-

451

... More
Rocky strata including Boulders.Upto 90 metre depth. 200 mm dia.

88.5

-

690

... More
Rocky strata including Boulders. Beyond 90 metre depth. 200 mm dia

25

-

716

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of Engineer-in-Charge. 200 mm nominal dia(minimum wall thickness 10mm).

63

-

559

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire and labour charges, fittings and accessories etc. All complete, for all depths, as per direction of Engineer-in-Charge. 200 mm nominal size dia.

30

-

878

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed and approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire and labour charges, fittings and accessories, all complete, for all depths, as per direction of Engineer- in-Charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm.

22

-

1611

... More
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level and draw down etc. by step draw down method, collecting water samples and getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire and labour charges of air compressor, tools and accessories etc., all as per requirement and direction of Engineer-in-Charge.

3

-

478

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia

1

-

488

... More
Providing and fixing M.S. clamp of required dia made of 100 x10 mm flat to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts and nuts of required size complete. 200 mm clamp.

1

-

1281

... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. External work : including trenching and refilling etc. 50 mm dia. nominal bore

10

-

492

... More
Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC FRLS insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :- Light point/fan points. Primary short point

46

-

282

... More
Primary medium point

72

-

487

... More
Primary long point

102

-

737

... More
3 Pin 6 Amp socket outlet on separate board Medium point

7

-

637

... More
Long point

7

-

910

... More
Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. Socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board.

28

-

224

... More
Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) of ISI marked suitable size etc. as required as per specification. 2x2.5 Sq.mm.

186

-

69

... More
4x2.5 Sq.mm.

440

-

116

... More
Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :- Light Point/Fan Points. Primary short point

14

-

305

... More
Medium Primary medium point

14

-

532

... More
Primary long point

14

-

816

... More
Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board.

14

-

170

... More
Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size etc. as required as per specification, 2x2.5 Sq.mm.

68

-

83

... More
4x2.5 Sq.mm.

136

-

127

... More
6x2.5 Sq.mm.

136

-

167

... More
Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:- 3 Module metal box

28

-

115

... More
6 Module metal box

14

-

173

... More
12 Module

26

-

274

... More
Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- - 3 Module PVC box

13

-

94

... More
6 Module PVC box

13

-

178

... More
Supplying and fixing PVC conduit ISI marked FRLS along with accessories on surface etc. as required - PVC conduit 25 mm. (MMS)

930

-

33

... More
Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification. - 1.5 sq. mm. wire, 3 X 1.5 sq. mm.

930

-

34

... More
Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- On separate board - Medium point

7

-

1154

... More
Long point

7

-

1678

... More
Extra long-I

14

-

2293

... More
Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)- 6 Way double door IP 43 protection

1

-

835

... More
Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator) - 8 Way double door IP 43 protection

6

-

1048

... More
Supply of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828 - MCCB current rating – upto 63 Amp, 10kA, 3P 415V AC

7

-

743

... More
Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- Single pole - MCB SP 6Amp to 32Amp 10kA rating

54

-

136

... More
Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing board - 100 Watt (1 module)

72

-

296

... More
Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete of approved as required confirming to IS :374/2019 with upto date amendments. - Ceiling Fan (ISI marked)-1200 mm Sweep, with minimum air delivery 210 m³/min and service value ≥ 4.00 as per BEE..

72

-

1668

... More
Supply and fixing Led tube rod comprising of LED tube with non-integral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy 100 lm/Watt. LED driver PF 0.95 & THD 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. - Tube light LED 1 X 18Watt, Integral i/c batten aluminium body, PC diffuser.

110

-

713

... More
Supply and fixing street light with high power LED of 3 to 6 Watt each on existing bracket assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job. - 60Watt, color temp 3000-6500k as required.

28

-

9791

... More
Earthing with copper earth plate 600mm X 600mm X 3mm thick including accessories and providing masonry encloser in cement mortar, cover plate having locking arrangement on the top and G.I. watering pipe 20mm dia 2.7 metre long etc. (but without charcoal or coke and salt) complete as required

13

-

8461

... More
Add extra for using salt and charcoal/coke for G.I. plate or copper plate earth electrode as required including excavation in hard rock and refilling the pit with black soil.

4

-

2365

... More
Providing and fixing 25mm X 5mm copper strip on surface or in recessed for connection etc. as required

70

-

1064

... More
Providing and fixing 4.00mm copper wire on surface or in recessed for loop earthing as required

210

-

91

... More
Supplying and laying 25mm X 5mm G.I. strip at 0.5 Metre below ground level as strip earth electrode including soldering etc. as required.

60

-

83

... More
Providing & fixing 25mm X 5mm copper strip on surface or recessed for connection etc. as required.

20

-

761

... More
Providing and fixing 4.0mm (8 SWG) dia G.I. wire on surface or in recessed for loop earthing as required

60

-

14

... More
Wiring for sub-mains with PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid PVC conduit (MMS) FRLS ISI marked of suitable size (conduit included) including 2mm thick accessories, connection etc, as required as per specification. (Refer General Notes for Classification of Conduit Wiring Point No.11) - 3 Wire sub main - 2.5 sq. mm. cable

120

-

100

... More
Supply and fixing street light with high power LED of 3 to 6 Watt each on existing bracket assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job. - 60Watt, color temp 3000-6500k as required.

18

-

9791

... More
Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor - 3½ core armoured - 25 sq. mm

500

-

137

... More
Supply of steel tubular pole swaged type as per IS:2713-1980 complete with base plate and top Canopy - 410 SP-8 - 7.50 metre

18

-

7462

... More
Supplying and erection of water tight terminal box made of 16 SWG M.S. Sheet (1.6mm thick) i/c rubber gasket of required size suitable for kit kat/MCB/switch including 2 nos. pole clamp of M.S. flat iron size 32x3mm, nut and bolts, 4 Pole epoxy connector nut & bolt type, 30Amp, 500Volt. The box shall be powder coated excluding the cost of the kit kat/MCB/Switch complete as per specification. - 20x15x10 Cms.

18

-

685

... More
Supplying and fixing of 32mm dia. X 2.00 meter long G.I. pipe (medium class) bracket for mounting of fluorescent/S.V/M.H/L.E.D lamp street light fittings on poles including bending the pipe to the required shape and wiring with 1.5sq.mm W.P./PVC wire etc. as required.

18

-

575

... More
Supplying &installation of required capacity of three phase, 50 Hz,415V, deep well submersible pump steel body, as per IS of approved make, suitable upto 6 " tube well with control panel starter suitable for submersible pump with dry run protection, single phase preventer, connections, including clamp, bore cap etc. as required as per specifications but excluding pipe and connection cable. - 1.5 HP with 16-17 stages, head metre 114-33, discharge LPM 15-55

1

-

32255

... More
Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make. - 6.0 sq.mm multi strand

115

-

162

... More
Supplying and laying of approved make HDPE pipe as per IS:4984 and IS:14333 with latest amendment for installation of submersible pump with necessary connection, socket/couplings, tees, etc. as required (PE-63 & working pressure 6 kgf/sq cm) - 50 mm Outer Dia.

105

-

83

... More
Supplying and laying of approved make nylon rope 12 mm thick complete with binding for support of pump and motor.

110

-

76

... More
Supplying & installation of approved make required capacity 3 phase, 50 Hz, 415V, centrifugal mono-block pump, with starter i/c single phase preventer, connections, base channel foundation etc. as required as per specifications but excluding pipe and connection cable. - 10.0 HP head metre 10-36, discharge LPM 2400- 1200

4

-

47000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.