MP State Agro Industries Corporation Limited Tender

... More
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

MP State Agro Industries Corporation Limited Tender

Goods
Civil And Construction
Building Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date24 Jan 2025
Closing Soon13 Feb 2025
Tender Amount₹ 2,29,00,000 
Notes
Download

Costs

  • EMD

    ₹ 2,29,000
  • Document Cost

    ₹ 17,700
  • Tender Fee

    ₹ 1,534

Summary

Construction Of Composite Building And Godown Boundry Wall, Road Work Including Water Supply And Internal Electrification At District Office Campus

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Extra for every additional lift of 1.5 m or part thereof in excavation. (No extra lift is payable if work is done by mechanical means) All kinds of soil. SOR Item No. 2.25.1

682.96

30

20488.8

... More
Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing complete. Note: - Maximum thickness of this layer shall be 20 cm. SOR Item No. 2.26

55.31

672

37168.32

... More
Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete. With hard muram having CBR 12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm). SOR Item No. 2.27.1

246.29

393

96791.97

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level :With 20mm nominal size graded stone aggregate.M-20 – Grade concrete. SOR Item No. 4.1.1.2

48.56

4933

239546.48

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : With 40mm nominal size graded stone aggregate.Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate (M -7.5) .SOR Item No. 4.1.2.3

66.7

3474

231715.8

... More
Centering and shuttering including strutting, propping etc. and removal of form work for : Upto plinth: Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth. SOR Item No. 4.3.1

286.42

169

48404.98

... More
Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : M-20 Grade Concrete SOR Item No. 5.1.1

191.41

6153

1177745.73

... More
Centering and shuttering in cluding strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for concrete upto plinth level SOR Item No.5.9.1

225.91

190

43058.45

... More
Centering and shuttering in cluding strutting, propping etc. and removal of form for:Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. SOR Item No. 5.9.2

191.67

219

41975.73

... More
Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. Upto plinth level. SOR ITEM No 5.9.2.1

457.75

219

100247.25

... More
Centering and shuttering in cluding strutting, propping etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform.SOR Item No. 5.9.3

779.79

439

342795.68

... More
Centering and shuttering in cluding strutting, propping etc. and removal of form for:Lintels, beams, girders, bressumers and cantilevers.SOR Item No. 5.9.5

621.3

356

221182.8

... More
Centering and shuttering in cluding strutting, propping etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts.SOR Item No. 5.9.6

783.98

471

369411.38

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks of required colour strength, thickness pattern, surface texture (smooth/rough) and size/shape, conforming to 15658-2006 IS marked made by table vibratory method using PU mould, laid in required colour and pattern over 50mm thick compacted bed of stone dust, compacting and proper embedding/laying of inter locking paver blocks into the bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand including locking edges in 0.30 mm with courtyards, porch with M 15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturer's specifications and direction of Engineer-in- Charge.80 mm thick C.C. paver block of M-35 grade. SOR Item No. 11.72

125.34

805

100898.7

... More
Centering and shuttering in cluding strutting, propping etc. and removal of form for: Stairs, (excluding landings) except spiral-Staircases. SOR Item No. 5.9.7

48.24

435

21018.17

... More
Centering and shuttering in cluding strutting, propping etc. and removal of form for:Small lintels not exceeding 1.5m clear span, mouldingas incornices, window, sills, courses, bands, copings, bed plates, anchor blocks and the like. SOR Item No. 5.9.16

41.7

191

7964.7

... More
Centering and shuttering in cluding strutting, propping etc. and removal of form for:Weather shade, Chajjas, corbels etc., including Edges.SOR Item No. 5.9.19

61.52

534

32863.98

... More
Providing, hoisting and fixing up to floor two level precast reinforced cement concrete in lintels, manhole cover, shelves and like including setting in cement mortar 1:3 (1 cement : 3 sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement with M 15 –Grade Concrete.SOR ITEM No 5.11

0.15

7830

1174.5

... More
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3.Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”) Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786 SOR Item No. 5.16.6

47993.55

77

3695503.35

... More
Add extra for providing reinforcement above Floor two level for every additional floor or part thereof. SOR Item No. 5.17Add extra for providing reinforcement above Floor two level for every additional floor or part thereof. SOR Item No. 5.17

-

-

-

... More
On First Floor Level

7871.94

-

1574.39

... More
On Second & Third Floor Level

14051

-

5620.4

... More
On Mumty Floor Level

2228.94

-

1337.36

... More
Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 (1 cement: 3 sand).SOR ITEM No 5.34

83.38

96

8004.48

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-Charge). SOR Item No. 11.73

7.03

6097

42861.91

... More
Brick work with well burnt chimney bricks in bulls pattern trench kiln, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level i/c curing etc. complete. Cement Mortar 1:6 (1 cement:6 sand).SOR Item. No. 6.4.2

151.71

5255

797236.05

... More
Extra for brick work in superstructure above floor two levels for each additional floor or part thereof respective item.SOR Item No. 6.11

-

-

-

... More
For FF

42.01

105

4415.25

... More
For SF TO TF

84.34

210

17728.27

... More
For FF

30.18

315

9515.75

... More
Providing half brick masonry with well burnt chimney bricks in bull pattern trench kiln crushing strength not less than 25 kg /cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level.Cement mortar 1 : 4 (1 cement : 4 sand) SOR Item No. 6.13.2

380.69

615

234124.35

... More
Extra for half brick masonry in superstructure, above floor two level for every floor or part thereof respective item. SOR Item No. 6.16

-

-

-

218.08

11

2398.88

... More
SF TO TF

210.34

22

4627.48

... More
Extra for providing and placing in position 2 Nos. 8mm dia. M.S. bars at every third course of in half brick masonry. SOR Item No. 6.17

380.69

127

48347.63

... More
Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor two level in : Having 75 kg / cm2 average compressive strength. Cement mortar 1:6 (1 cement : 6 sand) SOR ITEM No 6.7.2.2

45.21

5049

228265.29

... More
Extra for brick work in superstructure above floor two levels for each additional floor or part thereof respective item. SOR ITEM No 6.11

3.33

100

336.26

... More
Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and upto floor two level excluding cost of centering, shuttering, finishing and reinforcement: SOR Item No. 5.2.1

92.93

6231

579046.83

... More
Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in beams, suspended floors, roofs having slope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement in concrete grade. SOR Item No. 5.3.1

184.15

6541

1204525.15

... More
Extra for R.C.C. work above floor two level for each floors or part thereof.Extra for R.C.C. work above floor two level for each floors or part thereof. (except items 5.26 and 5.29) SOR Item No. 5.31

-

-

-

... More
On First Floor Level For Item 5.2.1

11.18

62

696.63

... More
On Second Floor & Third Floor Level For Item 5.2.2

22.36

124

2786.5

... More
On Mumty Floor Level For Item 5.2.1

8.12

186

1517.87

... More
On First Floor Level For Item 5.3.1

45.27

65

2961.11

... More
On second Floor & Third Floor Level For Item 5.3.2

85.15

130

11139.32

... More
On Mumty Floor Level For Item 5.3.1

7.8

196

1530.59

... More
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.6 m, for every additional height of 1 metre or part thereof (Plan area to be measured) SOR Item No. 5.10.1

281.25

212

59625

... More
Providing for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. SOR ITEM No 5.24

224

18

4144

... More
Providing and placing in position precast reinforced cement concrete waffle units square or rectangular as per design and shape for floors and roofs in M-20 –Grade Concrete (with graded stone aggregate 10mm nominal size) including flush or deep ruled pointing at joints in Cement mortar 1:2 (1 Cement : 2 sand), making necessary holes of required sizes for carrying through service lines etc. including provision of steel hooks for lifting and form work, handling, hoisting, centering and erection complete for all floor levels but excluding the cost of reinforcement.. SOR ITEM No 5.29

10.36

13479

139642.44

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. SOR Item No. 9.43.1

1150.5

119

136909.5

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion. Powder coated aluminium (minimum thickness of powder coating 50 micron) SOR Item No. 21.1.1.2

600.25

416

249704

... More
For shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron) . SOR Item No. 21.1.2.2

773.2

484

374228.8

... More
Filling the gap in between aluminium frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width. SOR Item No. 21.9

364

53

19292

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item) :With float glass panes of 5 mm thickness.SOR Item No. 21.3.2

120.05

948

113807.4

... More
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 12 mm mild steel U beading. SOR Item No. 9.124.2

60.21

1370

82487.7

... More
Providing and fixing pressed steel door frames made of 1.6 mm thick steel profile conforming to IS: 4351 manufactured from commercial mild steel sheet including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.60 mm pressed mild steel welded or rigidly fixed together by mechanical means, including 2.5mm thick M.S. pressed butt hinges, with mortar guards, lock strike-plate and shock absorbers as specified filling the frame with Cement Concrete 1:3:6 at site before fixing (cost of concrete to be paid separately) fixing with adjustable lugs (200 mm long & 1.0 mm thick) and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in- charge:

-

-

-

... More
Profile C of 1.60mm thick single rebate of size 100mmx50mm Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). .SOR Item No. 10.12.2.2

10.2

424

4324.8

... More
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. SOR Item No. 10.22.2

1250

105

131250

... More
Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame, concrete/ masonry, etc. as per direction of Engineer-in-charge. .10 x120 mm. SOR ITEM No. 10.24.3

40

78

3120

... More
Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid door/window/ceosetory windows and other frames/chowkhat comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice .husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed S.S. screws having minimum density of 750 kg/m3 and screw withdrawal strength of 2200 N (Face) & 900 N (Edge), minimum compressive strength 58 N/mm2, modulus of elasticity 900 N/ mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S. hold fast/lugs/S.S.dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/lugs or S.S. dash fasteners shall be paid separately). Single rebate (75 mm X 50 mm). Single rebate (100 mm X50 mm). SOR Item No. 9.169.2

113.05

720

81396

... More
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. SOR it no. 9.19.1

3.38

1870

6320.6

... More
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. SOR Itgem No. 9.19.2

38.83

1696

65855.68

... More
25mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. SOR Item No. 9.19.3

5

1623

8115

... More
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). SOR Item No. 9.24

9.46

93

879.78

... More
6 mm cement plaster of mix : 1:3 (1 cement : 3 sand) SOR Item No. 13.8

1210.42

144

174300.48

... More
12 mm cement plaster of mix : 1:6 (1 cement : 6 sand) . SOR Item No. 13.1.2

1203.3

160

192528

... More
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement : 6 sand). SOR Item No. 13.2.2

2175.47

168

365478.96

... More
Neat cement punning SOR ITEM No 13.10

199.15

30

5974.5

... More
Providing and fixing mesh in vertical and horizontal junction of RCC and brick/AAC work including scaffolding and all lead and lift etc. complete. G.I. chicken mesh as per ISI specification and in the required width with 50mm long Bombay nails before plastering upt 10 meter height. SOR Item No. 13.27.1

383.68

62

23788.16

... More
12 mm thick plain cement mortar band in cement mortar 1:4 (1cement: 4 sand): Raised Band. SOR Item No. 13.28.3

550

2

1100

... More
12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 sand) : Flush Band. SOR Item No. 13.28.1

1000

2

2000

... More
18 mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 sand): Flush Band SOR ITEM No 13. 29.1

50

2

100

... More
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) SOR Item No. 22.14.1

10.92

6569

71733.48

... More
Grading roof for water proofing treatment with Cement mortar 1:3 (1 cement : 3 sand). SOR ITEM No 22.14.2

0.06

9308

558.48

... More
Providing and fixing ISI marked stainless steel sliding door bolts with nuts and screws etc. complete :300x16 mm SOR it no. 9.65.1

4

389

1556

... More
Providing and fixing ISI marked stainless steel sliding door bolts with nuts and screws etc. complete :250x16mm. SOR Item No. 9.65.2

23

326

7498

... More
Providing and fixing ISI marked stainless steel tower bolt black finish, (Barrel type) with necessary screws etc. complete : 250x10 mm.SOR it no. 9.66.1

4

148

592

... More
Providing and fixing ISI marked stainless steel door latches with screws etc. complete :250x20x6 mm.SOR Item No. 9.68.2

63

173

10899

... More
Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete : 125 mm. SOR Item No. 9.69.1

54

60

3240

... More
Providing and fixing Stainless steel hanging type floor door stopper with necessary screws, etc. complete.SOR Item No. 9.76

22

103

2266

... More
Providing and fixing bright finished brass 100 mm mortice latch and lock ISI marked with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles with necessary screws etc. complete (Best make of approved quality). SOR Item No. 9.84

10

820

8200

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x 40x5mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6mm for diagonal braces. SOR Item No. 10.5.1

1.89

2604

4921.56

... More
Providing and laying vitrified floor tiles Multi/Double charged (Minimum top layer thickness 2.0mm) Neno Polished self design, in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, quality/ premium quality in flooring laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete. In light shade glossy/ rustic /stain finished. Size 800X800mm thickness 11-12mm SOR Item No. 11.78.1.2

560.94

1223

686029.62

... More
Providing and laying vitrified floor tiles Multi/Double charged (Minimum top layer thickness 2.0mm) Neno Polished self design, in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in skirting laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete. In light shade glossy/ rustic /stain finished (b) Size 800X800mm thickness 11-12mm. SOR Item No. 11.79.1.2

44.44

1212

53861.28

... More
Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1cement : 4sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish wherever required etc. complete at all levels. samples approved by Engineer-in-charge. Raj Nagar plain/ White Marble/ Udaipur Green Marble/ Zebra black. SOR Item No. 11.22.1

6.91

1797

12417.27

... More
Granite of any colour and shadeGranite coarse grained light black/ light red/white with crystal of other colours and various patterns SOR Item No. 11.22.3

92.1

2113

194607.3

... More
Providing edge moulding to 18mm thick marble stone counters, Vanities, window sills etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work. SOR Item No. 11.40.2

240.32

269

64646.08

... More
Extra for providing opening of required size and shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. SOR Item No. 11.42

1

232

232

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1: 4 (1cement : 4sand) 25mm thick.(Area of slab to be over 0.25 sqm). SOR Item No. 11.36

262.03

1174

307623.22

... More
Kota stone slabs in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 10-12 mm thick. SOR Item No. 11.38.1

50.44

1177

59367.88

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to I.S. 4454- part-1 and M.S. top cover of required thickness for rolling shutters. 80x1.25mm M.S. laths with 1.25 mm thick top cover. SOR Item No. 10.6.1

26.13

2200

57486

... More
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. (For payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).SOR Item No. 10.25

80

582

46560

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete. Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of APD/Chief Engineer will be required. SOR Item No. 13.41

4872.46

74

360562.04

... More
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: SOR Item No. 13.46

3024.59

64

193573.76

... More
Finishing walls by only mechanical or manual means with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. SOR Item No. 13.51

1466.76

132

193612.32

... More
Providing and Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality. 1.0 mm thick. SOR Item No. 9.134.2

134.13

691

92683.83

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. SOR Item No. 13.64

122.64

53

6499.92

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. SOR Item No. 22.5

63.82

207

13210.74

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25mm wide x 1.6 mm thick with flanges of 27mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high

-

-

-

... More
Providing and fixing false ceiling atall height including providing andfixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mmcentre to centre, one flange fixed tothe ceiling with dash fastener 12.5 mmdia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in adirection perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with Plain board conforming to IS: 2095- Part I : 2011 (Board with BIS certification marks).SOR Item No. 12.58.2.1

125.79

750

94342.5

... More
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre- painted with polyester paint, allcomplete for all heightsas per specifications, drawings and as directed by Engineer-in-charge.

-

-

-

... More
12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. SOR ITEM NO. - 12.59.4

80.36

1164

93539.04

... More
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer -in- Charge (Door handle, lock and stopper etc.to be paid separately). SOR Item No. 21.18

19.09

4958

94648.22

... More
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel (ACP) Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including: a) Structural analysis and design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades.The aluminium composite panel cladding sheet shall be coil coated, with kynar 500 based PVDF / fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.

-

-

-

... More
c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material and labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. upto two decimal places. 4 mm thick alumminium composite pannel material consisting of 3 mm thick FR grade mineral core sandwiched between two alumminium sheets (each 0.5mm thick). SOR Item No.8.7.1

230.16

3800

874608

... More
Steel work in built up M.S. tubular section (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes SOR ITEM No 10.14.1

3411.6

117

399157.2

... More
Providing and fixing PUF insulated continueous sandwich panels for wall of total thickness not less than 40 mm and width 1.0m made out from continue line method on automatic plant.panel shall have 0.35 mm thick pre coated GI sheet on both side of Polyurethane foam confirming to IS 12436:1988. The precoated sheet shall be of minimum 240 mpa steel grade confirming to IS 14246:1995 and shall have zinc coating of minimum 120 gsm as per IS:277:1992 , 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 micron. The PPGI Sheet shall have plastic protective guard film of minimum 25 microns to avoid scratches during trasportation. The panels shall be vertically joined together by tongue and groove joints. The PU foam shall be self extinguishing, fire retardant type having minimum density of 40 kg/Cum. ( ±2 Kgs) including 0.25 mm thick craft paper edging on both edges. The panels shall be fixed to the steel frame structure with minimum 5mm thick self tapping Gi screws of required length and nos. with minimum spacing of 300 mm c/c. PPGI sheet 0.5mm thick skin on both sides. SOR it 24.15.1.1

88.4

2566

226834.4

... More
Providing and fixing PUF insulated continuous sandwich panels for roofs of total thickness not less than 30 mm made out from continue line method panel shall have pre coated GI sheet on both side of Polyurethane foam with external face being corrugated in shape for GI and PU foam both material. The crest height of the panel shall be of 35 mm minimum wiht 250mm c/c pitch. The Precoated sheet shall be of minimum 240mpa steel grade confirming to IS 14245:1995 and shall have zinc coating of 120 gsm as per IS:277, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 micron. The PPGI Sheet shall have protective guard film of minimum 25 microns to avoid scratches wihile trasportation. The roof panels are laid over a frame work of trusses, columns and purlins fixed using 90 mm self drilling bolt with rubber washer including all types of flashings. PU Foam must be self extinguishing. Fire reterdant type having minimum density of 40 Kg/ Cum.(±2 Kgs) including 0.25 mm craft paper edging, self tapping screws of required length and nos. etc complete as per structural design and direction of Engineer-in-charge. PPGI sheet 0.5mm thick skin on both sides. SOR it 24.14.1

99.75

2555

254861.25

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittingsi/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in Charge. Concealed work including cutting chases and making good the walls etc.,

-

-

-

... More
20 mm nominal outer dia. Pipes. SOR Item No. 18.6.2.2

75

234

17550

... More
25 mm nominal outer dia. Pipes. SOR Item No. 18.6.2.3

75

288

21600

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall

-

-

-

... More
20 mm dia. nominal bore. SOR Item No. 18.6.1.2

65

153

9945

... More
25 mm dia. nominal bore. SOR Item No. 18.6.1.3

65

177

11505

... More
40 mm dia. nominal bore. SOR Item No. 18.6.1.5

65

354

23010

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931, 15 mm nominal bore. SOR Item No. 18.31

9

840

7560

... More
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gm, 15 mm nominal bore. SOR Item No. 18.32

1

1258

1258

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore. SOR Item No. 18.14.2

1

431

431

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : With C.I. wheel of approved quality (screwed end).

-

-

-

... More
25 mm nominal bore SOR Item No. 18.12.1.1

2

486

972

... More
40 mm nominal bore SOR Item No. 18.12.1.3

2

677

1354

... More
Cutting holes upto 30x30 cm in walls including making good the same :With common burnt clay bricks of 25 kg /sqcmor flyash bricks of 50 kg/cm2 compressive strength. SOR Item No. 18.56

10

154

1540

... More
Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. SOR Item No. 18.57

10

129

1290

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or S trap, UPVC P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.SOR Item No. 17.1.1

2

2995

5990

... More
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid. SOR Item No. 17.2.1

9

3036

27324

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. SOR Item No. 17.11.1

10

2460

24600

... More
Providing and fixing UPVC trap of self cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet SOR Item No. 17.61

17

517

8789

... More
Providing and fixing C.P. brass grating of approved quality and make conforming to IS:specification. 100 mm dia. SOR Item No. 17.78.1

17

74

1258

... More
Providing and fixing in position best Indian Health Faucet with 8mm dia 1 meter long Flexible Tube and wall bracket with N. R. V. (non-return wall).(Premium Range Sanitary Ware). . SOR Item No. 25.37

9

1818

16362

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250mm. SOR Item No. 17.14.1.1

1

8074

8074

... More
Providing and fixing toilet paper holder: SOR Item No. 17.70.1

9

340

3060

... More
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. SOR Item No. 17.6.1

6

2754

16524

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia. SOR Item No. 17.64.1.1

10

87

870

... More
Providing and fixing bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. SOR Item No. 17.67

10

2440

24400

... More
Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Soap Dish Holder. (Premium Range). SOR Item No. 25.53

10

1191

11910

... More
Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Toilet paper holder with Flap. (Premium Range) SOR Item No. 25.56

9

1888

16992

... More
Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Single Towel Rail 600 mm long. (Premium Range) SOR Item No. 25.50

9

2631

23679

... More
Providing and laying below ground unplasticised PVC pipe to with stand working pressure of 4 kg/cm2 soild waste pipes confirming to IS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving 10mm gap for thermal expansion all necessary fittings etc complete. Excavation to be paid seperataly. 160 mm diameter OD (min. wall thickness 4.0mm). SOR Item No. 19.4.2

60

477

28620

... More
Providing and laying cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) all-round PVC. pipes including bed concrete as per standard design: 160 mm diameter PVC. Pipe .SOR Item No. 19.5.2

60

704

42240

... More
Providing and fixing square-mouth S.W. gully trap class SP1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design : 180 x 150 mm size P type. With well burnt bricks SOR Item No. 19.7.3.1

8

1913

15304

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With well burnt bricks SOR Item No. 19.9.1.1

8

7997

63976

... More
Making khurras 45x45 cm (sunk area) with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 sand) and a coat of neat cement rounding the edge and making and finishing the outlet complete so as to receive rain water/ spillage water on roof in a sunk area and completely rain out in a near perfect strain meter motion into rain water pipe. SOR Item No. 12.27

6

156

936

... More
Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum wall thickness 3.2mm)

-

-

-

... More
75 mm diameter (minimum wall thickness 3.2mm) SOR Item No. 17.58.1

60

136

8160

... More
110 mm diameter (minimum wall thickness 3.2mm) .SOR Item No. 17.58.2

60

238

14280

... More
Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.

-

-

-

... More
Coupler 75 mm SOR Item No. 17.59.1.1

18

117

2106

... More
Coupler 100 mm SOR Item No. 17.59.1.2

18

154

2772

... More
Single pushfit Coupler 75 mm SOR Item No. 17.59.2.1

18

140

2520

... More
Single pushfit Coupler 100 mm SOR Item No. 17.59.2.2

18

195

3510

... More
Single tee with door 75x75x75 mm SOR Item No. 17.59.3.1

10

219

2190

... More
Single tee with door 110x110x110 mm SOR Item No. 17.59.3.2

10

346

3460

... More
Single tee without door 75x75x75 mm SOR Item No. 17.59.4.1

10

201

2010

... More
Single tee without door 110x110x110 mm SOR Item No. 17.59.4.2

10

266

2660

... More
Bend 87.50 75 mm SOR Item No. 17.59.5.1

10

117

1170

... More
Bend 100 mm SOR Item No. 17.59.5.2

10

172

1720

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.

-

-

-

... More
75 mm SOR Item No. 12.34.1

60

97

5820

... More
110 mm SOR Item No. 12.34.2

60

114

6840

... More
Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm diameter (minimum wall thickness 2.2 mm). SOR Item No. 12.32.2

75

238

17850

... More
Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.

-

-

-

... More
Bend 87.5° 110 mm (minimum wall thickness 2.2mm) SOR Item No. 12.33.5.2

20

112

2240

... More
Shoe 110 mm (minimum wall thickness 2.2mm) SOR Item No. 12.33.6.2

10

99

990

... More
Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of bombay nail of required length including making good the wall etc. complete. 110 mm (minimum wall thickness 2.2mm) SOR Item No. 12.34.2

65

114

7410

... More
Providing and fixing to the inlet mouth of rain water pipe fixing cast iron grating 15cm diameter and weighing not less than 440 grams.SOR Item No. 12.35

6

43

258

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank SOR Item No. 18.28

2000

7

14000

... More
Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :-Using Modular Accessories SOR ITEM NO. 4.1 /Page 7

-

-

-

... More
Light Point/Fan Points. SOR ITEM NO. 4.1.1 /Page 7 Primary short point

31

451

13981

... More
Light Point/Fan Points. SOR ITEM NO. 4.1.1 /Page 7 Primary mediumpoint

40

830

33200

... More
Light Point/Fan Points. SOR ITEM NO. 4.1.1 /Page 7 Primary long point

150

1300

195000

... More
(Light point/fan points) looping point SOR ITEM NO. 4.1.2 /Page 7

-

-

-

... More
Secondary medium point

10

415

4150

... More
Secondary long point

4

650

2600

... More
3 Pin 6 Amp socket outlet on Separate Board SOR ITEM NO. 4.1.3 /Page 7

-

-

-

... More
Short point

3

574

1722

... More
Medium point

2

990

1980

... More
Long point

7

1515

10605

... More
Call bell/buzzer points SOR ITEM NO. 4.1.4 /Page 7 Long point

2

1183

2366

... More
Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on sameboard. Using Modular Accessories SOR ITEM NO. 4.2 /Page 7

36

265

9540

... More
Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size etc. as required as perspecification SOR ITEM NO. 4.3 /Page 7

-

-

-

... More
2x2.5 Sq.mm.

140

139

19460

... More
4x2.5 Sq.mm.

60

224

13440

... More
6x2.5 Sq.mm.

30

288

8640

... More
8x2.5 Sq.mm.

20

353

7060

... More
Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :-Using Modular Accessories SOR ITEM NO. 9.1 /Page 14

-

-

-

... More
On separate board Medium point

1

1749

1749

... More
On separate board Long point

3

2612

7836

... More
On separate board Extra long-I

7

3648

25536

... More
On separate board Extra long-II

6

4771

28626

... More
On separate board Extra long-III

2

5986

11972

... More
Same board switch & socket 16 Amp./S.S. combined 20/16/6 Amp SOR ITEM NO. 9.2 /Page 14

1

437

437

... More
Supply and fixing PVC conduit ISI marked FRLS along with the accessories in concealed system etc. as required SOR ITEM NO. 16 /Page 19

-

-

-

... More
PVC . Conduit 20 mm (HMS) SOR ITEM NO. 16.1 /Page 19

20

61

1220

... More
PVC . Conduit 25 mm (HMS) SOR ITEM NO. 16.2 /Page 19

40

74

2960

... More
PVC . Conduit 32 mm (HMS) SOR ITEM NO. 16.3 /Page 19

25

115

2875

... More
Supplying and fixing factory fabricated hot dip galvanized switch box for normal flush type accessories of minimum 1.2 mm thickness for up to 200mmx250mm size boxes and 1.6mm minimum thickness for higher size boxes, earth terminal stud with nut and washer, including 3 mm thick synthetic phenolic resin bonded laminated sheet conforming to grade P-I of IS:2036- 1974 on surface/concealed including all necessary accessories, painting etc. as required as per specification:: SOR ITEM NO. 18.1 /Page 23

-

-

-

... More
FOR SURFACE/CONCEALED MSBox 100 mm X 100 mm X60mm deep SOR ITEM NO. 18.1.1 /Page 23

2

64

128

... More
FOR SURFACE/CONCEALED MS Box 180 mm X 100 mm X 60 mm Deep SOR ITEM NO. 18.1.3 /Page 23

4

57

228

... More
FOR SURFACE/CONCEALED MS Box 200 mm X 250 mm X 60 mm Deep SOR ITEM NO. 18.1.5 /Page 23

2

84

168

... More
Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:- SOR ITEM NO. 18.2 /Page 20

-

-

-

... More
FOR SURFACE/CONCEALED 1 Or 2 Module metal box SOR ITEM NO. 18.2.1 /Page 20

22

182

4004

... More
FOR SURFACE/CONCEALED 3 Module metal box SOR ITEM NO. 18.2.2 /Page 20

30

216

6480

... More
FOR SURFACE/CONCEALED 4 Module metal box SOR ITEM NO. 18.2.3 /Page 20

4

244

976

... More
FOR SURFACE/CONCEALED 6 Module metal box SOR ITEM NO. 18.2.4 /Page 20

19

309

5871

... More
FOR SURFACE/CONCEALED 8 / 9 Module metal box SOR ITEM NO. 18.2.5 /Page 20

5

373

1865

... More
FOR SURFACE/CONCEALED 12 Module metal box SOR ITEM NO. 18.2.6 /Page 20

4

502

2008

... More
FOR SURFACE/CONCEALED 16 Module metal box SOR ITEM NO. 18.2.7 /Page 20

16

585

9360

... More
FOR SURFACE/CONCEALED 18 Module metal box SOR ITEM NO. 18.2.8 /Page 20

2

642

1284

... More
Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC FRLS insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :-Using modular accessories SOR ITEM NO. 3..

-

-

-

... More
Light Point/Fan Points. SOR ITEM NO. 3.1.1 Primary short point

3

408

1224

... More
Light Point/Fan Points. SOR ITEM NO. 3.1.1 Primary long point

1

1141

1141

... More
Twin control light points SOR ITEM NO. 3.1.5 /Page 5 Short point

2

488

976

... More
Twin control light points SOR ITEM NO. 3.1.5 /Page 5 Mediumpoint

1

874

874

... More
Twin control light points SOR ITEM NO. 3.1.5 /Page 5 Long point

1

1294

1294

... More
Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp.Socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board.. Using Flush Type Normal Accessories SOR ITEM NO. 3.2

4

82

328

... More
Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- Using Modular Accessories. SOR ITEM NO. 8.1 /Page 14

-

-

-

... More
On separate board Short point SOR ITEM NO. 8.1.1 /Page 14

2

845

1690

... More
On separate board Medium point SOR ITEM NO. 8.1.2 /Page 14

3

1468

4404

... More
On separate board Long point SOR ITEM NO. 8.1.3 /Page 14

3

2183

6549

... More
Wiring for sub-mains with PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid PVC conduit (MMS) FRLS ISI marked of suitable size (conduit included) including 2mm thick accessories, connection etc, as required as per specification. (Refer General Notes for Classification of Conduit Wiring Point No.11) SOR ITEM NO. 22

-

-

-

... More
2 WIRE SUB-MAIN SOR ITEM NO. 22.1 4.0 sq. mm. cable SOR ITEM NO. 22.1.1.2

100

167

16700

... More
Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- SOR ITEM NO. 27.8 /Page 64-80

-

-

-

... More
Double pole SOR ITEM NO. 27.8.2 /Page 71 MCB DP 6Amp to 32Amp 10kA rating SOR ITEM NO. 27.8.2.2 /Page 71

2

887

1774

... More
Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (labour only) SOR ITEM NO. 28.4 /Page

-

-

-

... More
MCB / Isolator SP/DP SOR ITEM NO. 28.4.1 /Page

10

22

220

... More
Supplying and installing of RCBOs (Residual current circuit breaker with overload and short circuit protection) ISI marked complete as per I.S. standard conforming to IEC:61009-1 & IS:12640-2, 240/415V 50 Hz with 10 kA short circuit withstand capacity for earth leakage, overload & short circuit protection including connection in existing enclosure in approved manner as per specification. SOR ITEM NO. 27.21 /Page 64-80

-

-

-

... More
DP (4 module) SOR ITEM NO. 27.21.1 /Page 64-80 2 pole 32Amp, 100mA sensitivity SOR ITEM NO. 27.21.1.6 /Page 64-80

2

4666

9332

... More
FP (8module) SOR ITEM NO. 27.21.2 /Page 64-80 4 pole 63Amp, 100/300mA sensitivity SOR ITEM NO. 27.21.2.8 /Page 64-80

4

7926

31704

... More
Supply & fixing of approved make accepted standard sheet steel enclosure (dust protected) duly powder coated paint neutral bar suitable for MCB/RCBOs/MCCB of capacity as required etc. complete as per specification (exclusive of M.C.B./ MCCB/RCBOs) SOR ITEM NO. 27.23 /Page 64-80

-

-

-

... More
For MCB SOR ITEM NO. 27.23.1 /Page 64-80 FP enclosure SOR ITEM NO. 27.23.1.2 /Page 64-80

3

341

1023

... More
For MCB SOR ITEM NO. 27.23.1 /Page 64-80 FP RCBO enclosure SOR ITEM NO. 27.23.1.3 /Page 64-80

4

602

2408

... More
Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor. SOR ITEM NO. 41.4 /Page 139-160

-

-

-

... More
Armoured 3 core SOR ITEM NO. 41.4.2 /Page 139-160 2.5 sq. mm. SOR ITEM NO. 41.4.2.1 /Page 139-160

25

168

4200

... More
Armoured 4 core SOR ITEM NO. 41.4.4 /Page 139-160 6 sq. mm. SOR ITEM NO. 41.4.4.4 /Page 139-160

25

430

10750

... More
Laying of one number armoured/unarmoured cable 1.1KV grade of size not exceeding 25 sq. mm on wall/truss with approved type of iron clamp etc. as required. SOR ITEM NO. 41.49 /Page 157

50

25

1250

... More
Laying of underground cable armoured./ unarmoured as per specification in air suspended on existing approved type of iron clamp, G.I wire 7/1.6mm & shackle insulator/insulated strip complete. SOR ITEM NO. 41.52/Page 158

-

-

-

... More
1/2/3/4 Core cable upto 16 sq. mm SOR ITEM NO. 41.52.1 /Page 158

80

25

2000

... More
Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification. SOR ITEM NO. 19.1 /Page 21

-

-

-

... More
1.5 sq mm SOR ITEM NO. 19.1.1 /Page 21 3 X 1.5 sq mm SOR ITEM NO. 19.1.1.3 /Page 21

50

56

2800

... More
2.5 sq mm SOR ITEM NO. 19.1.2 /Page 21 1 X 2.5 sq mm SOR ITEM NO. 19.1.2.1 /Page 21

250

30

7500

... More
4.00 sq mm SOR ITEM NO. 19.1.3 /Page 21 3 X 4.00 sq mm SOR ITEM NO. 19.1.3.3 /Page 21

20

134

2680

... More
Wiring for sub-mains with PVC insulated cable FRLS with copper multi strand conductor ISI marked in recessed/concealed rigid PVC conduit (HMS) FRLS ISI marked of suitable size (conduit included) including 2mm thick accessories, connection etc, as required as per specification. (Refer General Notes for Classification of Conduit Wiring Point No.11) SOR ITEM NO. 23.1 /Page 26

-

-

-

... More
2 WIRE SUB-MAIN SOR ITEM NO. 23.1.1 /Page 26 4.0 sq. mm. cable. SOR ITEM NO. 23.1.1.2 /Page 26

15

219

3285

... More
2 WIRE SUB-MAIN SOR ITEM NO. 23.1.1 /Page 26 6.0 sq. mm. cable. SOR ITEM NO. 23.1.1.3 /Page 26

25

264

6600

... More
2 WIRE SUB-MAIN SOR ITEM NO. 23.1.1 /Page 26 10.0 sq. mm. cable. SOR ITEM NO. 23.1.1.4 /Page 26

25

348

8700

... More
4 WIRE SUB-MAIN SOR ITEM NO. 23.1.4 /Page 26 16.0 sq. mm. cable. SOR ITEM NO. 23.1.4.5 /Page 26

70

873

61110

... More
Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- SOR ITEM NO. 27.8 /Page 70

-

-

-

... More
SINGLE POLE SOR ITEM NO. 27.8.1 /Page 71 MCB SP 6Amp to 32Amp 10kA rating SOR ITEM NO. 27.8.1.2 /Page 71

62

263

16306

... More
Double pole SOR ITEM NO. 27.8.2 /Page 71 MCB DP 6Amp to 32Amp 10kA rating SOR ITEM NO. 27.8.2.2 /Page 71

5

887

4435

... More
For Triple pole SOR ITEM NO. 27.8.3 /Page 71 MCB TP 6Amp to 32Amp 10kA rating SOR ITEM NO. 27.8.3.2 /Page 71

3

1411

4233

... More
Supplying of MCB Isolators suitable for 240/415 Volts, 50 Hz AC supply with kA value rating 10 kA of approved make conforming to IS:13947-Part III :1993 & IEC:60947- 3:2001 (without enclosures ) :- SOR ITEM NO. 27.10 /Page 73

-

-

-

... More
Double pole SOR ITEM NO. 27.10.2 /Page 73 Current rating upto 40Amp SOR ITEM NO. 27.10.2.1 /Page 73

5

575

2875

... More
FOUR POLE SOR ITEM NO. 27.10.4 /Page 73 Current rating upto 63Amp SOR ITEM NO. 27.10.4.2 /Page 73

4

1398

5592

... More
Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)- SOR ITEM NO. 27.11 /Page 74

-

-

-

... More
2 Way single door SOR ITEM NO. 27.11.1 /Page 74

3

447

1341

... More
4 Way double door IP 43 protection SOR ITEM NO. 27.11.3 /Page 74

2

1699

3398

... More
8 Way double door IP 43 protection SOR ITEM NO. 27.11.5 /Page 74

2

2127

4254

... More
12 Way double door IP 43 protection SOR ITEM NO. 27.11.6 /Page 74

1

2738

2738

... More
Supplying of approved make vertical TPN MCB DB metal double door IP 43 protection with provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP/TP MCBs as outgoing inclusive of busbar, neutral bar, earth bar, & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator) SOR ITEM NO. 27.13 /Page

-

-

-

... More
4 Way (8+12) SOR ITEM NO. 27.13.2 /Page

3

13577

40731

... More
6 Way (8+18) SOR ITEM NO. 27.13.2 /Page

1

15436

15436

... More
Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (labour only) SOR ITEM NO. 28.4 /Page

-

-

-

... More
MCB/Isolator SP/DP SOR ITEM NO. 28.4.1 /Page

64

22

1408

... More
MCB/MCCB Isolator TP/TPN/FP SOR ITEM NO. 28.4.2 /Page For item no :-

7

28

196

... More
Labour charges for fixing sheet steel enclosures, MCB/MCCBDB flush mounting type, as per accepted practice, duly embedded and end plate completely flushed in wall, cable connection etc. complete SOR ITEM NO. 28.8 /Page

-

-

-

... More
27.11.1 to 27.11.7 ; 27.12.1 to 27.12.3 & 27.13.1 SOR ITEM NO. 28.8.1 /Page

11

268

2948

... More
27.12.4 & 27.12.5 ; 27.13.2 to 27.13.4 ; 27.14.1 to 27.14.4 & 27.15.1 to 27.15.4 SOR ITEM NO. 28.8.2 /Page

1

297

297

... More
Supply and fixing as per specification call bell/buzzer of approved make with necessary materials complete. SOR ITEM NO. 29.3 /Page

-

-

-

... More
Ding dong bell SOR ITEM NO. 29.3.3 /Page

1

185

185

... More
Supply and fixing in position LED lamp of approved make SOR ITEM NO. 29.7 /Page

-

-

-

... More
9 Watt250Volt SOR ITEM NO. 29.7.5 /Page

15

110

1650

... More
Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing board SOR ITEM NO. 29.25 /Page

-

-

-

... More
100 Watt(2 module) SOR ITEM NO. 29.25.2 /Page

35

484

16940

... More
Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete of approved as required confirming to IS :374/2019 with upto date amendments.. SOR ITEM NO. 30.1 /Page 91

-

-

-

... More
Ceiling Fan (ISI marked)-1200 mm Sweep, with minimum air delivery 210 m³/min and service value ≥ 4.00 as per BEE.. SOR ITEM NO. 30.1.2 /Page 91

35

2292

80220

... More
Supplying, erection and testing of approved make 'Fresh air fan' AC 230-250 volts with connection and including frame bolt/anchor hole fasteners etc. complete finished and as required.. SOR ITEM NO. 30.4 /Page 92

-

-

-

... More
300 mm sweep double ball bearing SOR ITEM NO. 30.4.5 /Page 92

9

1973

17757

... More
Supplying and fixing of deluxe fresh air fan with louvers (ventilating fan) with self-closing louvers of decorative PVC blades mounting square frame of approved make complete with all necessary material as required SOR ITEM NO. 30.5 /Page

-

-

-

... More
200mm RPM1300/1400 SOR ITEM NO. 30.5.2 /Page

1

1654

1654

... More
Supplying, erecting and testing of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250 complete connection and including, frame bolt/anchor hole fasteners etc. complete finished and as required. SOR ITEM NO. 30.6 /Page

-

-

-

... More
300mm sweep RPM 900 / 1400 SOR ITEM NO. 30.6.1 /Page

4

2571

10284

... More
Supply and fixing M.S. down rod 14 SWG (2mm) thick for ceiling fan including threading, painting, making holes etc. as required complete. SOR ITEM NO. 30.13 /Page

20

114

2280

... More
Providing and fixing circular/hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by mean of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing. SOR ITEM NO. 32.3 /Page 104

35

90

3150

... More
Earthing with G.I. earth plate 600mm X 600mm X 6mm thick including accessories and providing masonry encloser in cement mortar, cover plate having locking arrangement on the top and G.I. watering pipe 20mm dia 2.7 metre long etc. (but without charcoal or coke and salt) complete as required. SOR ITEM NO. 37.3 /Page 114

6

7487

44922

... More
Add extra for using salt and charcoal/coke for G.I. plate or copper plate earth electrode as required including excavation and refilling the pit in all type of soil, murrum. SOR ITEM NO. 37.5 /Page 114

4

1655

6620

... More
Supply and laying 25mm X 5mm G.I. strip at 0.5 metre below ground level as strip earth electrode including jointing etc. as required. SOR ITEM NO. 37.9 /Page 115

27

130

3510

... More
Providing and fixing 25mm X 5mm G.I. strip on surface or in recessed for connection etc. as required SOR ITEM NO. 37.16 /Page 116

40

130

5200

... More
Providing and fixing 4.0mm (8 SWG) dia. G.I. wire on surface or in recessed for loop earthing as required. SOR ITEM NO. 37.17 /Page 116

80

25

2000

... More
Providing and fixing 4.87mm (6 SWG) dia.G.I. wire on surface or in recessed for loop earthing as required. SOR ITEM NO. 37.18 /Page 116

1140

30

34200

... More
Supply and laying G.I. earth lead duly installed on wall or in G.I. Pipe including connection etc. complete as required. SOR ITEM NO. 37.37 /Page 116

-

-

-

... More
13 sq mm ( 4 mm dia ) SOR ITEM NO. 37.37.1 /Page 116

20

26

520

... More
Supply and drawing PVC insulated copper cable (earth continuity conductor) of green colour FRLS with copper multi strand conductor ISI mark in existing conduit along with other wires as required as per specification : SOR ITEM NO. 37.39 /Page 119

-

-

-

... More
4 Sq mm SOR ITEM NO. 37.39.1 /Page 119

40

52

2080

... More
6 Sq mm SOR ITEM NO. 37.39.2 /Page 119

25

71

1775

... More
10 Sq mm SOR ITEM NO. 37.39.3 /Page 119

70

102

7140

... More
Supply and fixing Led tube rod comprising of LED tube with non- integral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy 100 lm/Watt. LED driver PF 0.95 & THD 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. SOR ITEM NO. 31.3 /Page 95

-

-

-

... More
Tube light LED 1 X 12Watt Integral i/c batten aluminium body, PC diffuser. SOR ITEM NO. 31.3.2 /Page 95-96

20

605

12100

... More
Tube light LED 1X20/22Watt, Integral i/c batten aluminium body, PC diffuser. SOR ITEM NO. 31.3.4 /Page 95-96

11

782

8602

... More
upply and fixing of recessed mounting type Led light fixture, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy100 lm/Watt. LED driver PF 0.95, THD 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. SOR ITEM NO. 31.4 /Page 97

-

-

-

... More
LED luminiare 2' X 2', 36Watt, color temp 3000-6500k as required. SOR ITEM NO. 31.4.1 /Page 97

20

3103

62060

... More
Supply and fixing surface mounting LED down lighter, LED of 1 to 3Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy100 lm/Watt. LED driver PF 0.95, THD 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.. SOR ITEM NO. 31.7 /Page 97

-

-

-

... More
14/15 Watt, color temp 3000-6500k as required. SOR ITEM NO. 31.7.4 /Page 97

35

1400

49000

... More
18/20 Watt, color temp 3000-6500k as required. SOR ITEM NO. 31.7.5 /Page 97

72

1783

128376

... More
Supply and fixing recessed mounting LED down lighter, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy100 lm/Watt. LED driver PF 0.95, THD 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job.. SOR ITEM NO. 31.6 /Page 97

-

-

-

... More
14/15 Watt, color temp 3000-6500k as required. SOR ITEM NO. 31.6.5 /Page 97

6

1150

6900

... More
18/20Watt, color temp 3000-6500k as required. SOR ITEM NO. 31.6.6 /Page 97

18

1651

29718

... More
Supply and fixing street light with high power LED of 3 to 6 W each on existing bracket assembled on single MCPCB, system lumens output with efficacy120 lm/W. luminiare having color temp upto 6500K & 50000 burning hrs. life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass/Lens type, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. SOR ITEM NO. 31.12 /Page 97

-

-

-

... More
24Watt to 25Watt, color temp 3000-6500k as required. SOR ITEM NO. 31.12.2 /Page 97-98

3

2737

8211

... More
Supply and fixing street light with high power LED of 3 to 6 Watt each on existing bracket assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job. SOR ITEM NO. 31.13 /Page 97-98

-

-

-

... More
90Watt, color temp 3000-6500k as required. SOR ITEM NO. 31.13.3 /Page 97-98

4

14173

56692

... More
Supplying and fixing flood light with high power LED of 3 to 6 Watt each assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. SOR ITEM NO. 31.14 /Page 97-98

-

-

-

... More
60Watt, color temp 3000-6500k as required. SOR ITEM NO. 31.14.3 /Page 97-98

3

7872

23616

... More
Fixing of street light bracket of required angular shape and size pipe bracket on wall/pole including M.S. clamp not less than 40X5mm flat, nut, bolt 12mm of required length with necessary material including connection 3 core flexible wire etc. complete as required excluding cost of pipe paid separately. SOR ITEM NO. 31.23 /Page 95 - 103

7

498

3486

... More
Supplying & installing G.I. pipe for protection of underground cable fixed on wall/support/in trench/fixed between two rigid existing support of wall/beam for erection of ceiling Fan/down rod for stiff pendent for light luminaries /fan/protective for earthing, lightening conductor down strip/overhead service line/for submersible cable or centrifugal pump for water supply with necessary iron clamp coupler, bend, tee, elbow, nuts and bolts etc. complete in an approved manner as required to complete excluding cost of excavation/dismantling & other finished masonry Item complete. SOR ITEM NO. 41.12 /Page 152

-

-

-

... More
For 'A' class G.I. pipe ISI marked(IS- 1161-69) SOR ITEM NO. 41.12.2 /Page 152 25.00mm SOR ITEM NO. 41.12.2.3 /Page 152

4.5

256

1152

... More
For 'A' class G.I. pipe ISI marked(IS- 1161-69) SOR ITEM NO. 41.12.2 /Page 152 50.00mm SOR ITEM NO. 41.12.2.6 /Page 152

8

503

4024

... More
Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor SOR ITEM NO. 41.1 /Page 139

-

-

-

... More
ARMOURED 2 Core SOR ITEM NO. 41.1.4 /Page 139 4 Sq.mm. SOR ITEM NO. 41.1.4.2 /Page 139/140

80

80

6400

... More
3½ CORE ARMOURED SOR ITEM NO. 41.1.8 /Page 140 70 Sq.mm. SOR ITEM NO. 41.1.8.4 /Page 140

100

500

50000

... More
Supplying and fixing heavy duty cable gland for P.V.C. insulated armoured cable with brass washer, rubber ring complete erected with cable and lead connection etc. as per specification complete. SOR ITEM NO. 41.5.1 /Page 145

-

-

-

... More
Gland size 38 mm 3½ x 70 sq. mm, 3 x 95 sq. mm SOR ITEM NO. 41.5.5 /Page 145

4

219

876

... More
Supplying and fixing crimping type alum.lugs as per I.S.S. specification suitable for following size of cable with alu./copper solid/stranded conductor evenly crimped with high/pressure tool and connected to switch gear/bus/M.C.C.B./M.C.B. etc. as required complete. SOR ITEM NO. 41.7 /Page 146

-

-

-

... More
For Conductor Size-6mm to 16 Sq.mm SOR ITEM NO. 41.7.1 /Page 146

4

8

32

... More
For Conductor Size- 35 Sq.mm SOR ITEM NO. 41.7.3 /Page 146

12

22

264

... More
For Conductor Size- 70 Sq.mm SOR ITEM NO. 41.7.5 /Page 146

12

35

420

... More
Supplying & installing G.I. pipe for protection of underground cable fixed on wall/support/in trench/fixed between two rigid existing support of wall/beam for erection of ceiling Fan/down rod for stiff pendent for light luminaries /fan/protective for earthing, lightening conductor down strip/overhead service line/for submersible cable or centrifugal pump for water supply with necessary iron clamp coupler, bend, tee, elbow, nuts and bolts etc. complete in an approved manner as required to complete excluding cost of excavation/dismantling & other finished masonry Item complete. SOR ITEM NO. 41.12 /Page 152

-

-

-

... More
For 'A' class G.I. pipe ISI marked(IS- 1161-69) SOR ITEM NO. 41.12.2 /Page 152 100.00mm SOR ITEM NO. 41.12.2.9 /Page 152

6

1151

6906

... More
Supplying and installing double wall corrugated pipes (DWC) of HDPE (IS 14930 Part II -marked) for cable laid underground with necessary material and at required depth upto 90cm. below road/ground surface, including excavation, back filling with excavated material, ramming and making the surface good. SOR ITEM NO. 41.14 /Page 152

-

-

-

... More
110.00mm outside dia. SOR ITEM NO. 41.14.4 /Page 152

64

252

16128

... More
Laying of one number armoured / unarmoured power cable 1.1.KV grade of size exceeding 25sq. mm but not exceeding 120 sq. mm direct in ground including excavation in all soil/ murrum /soft rock, sand cushioning, protective covering and refilling the pit etc. as required. SOR ITEM NO. 41.16 /Page 153

10

246

2460

... More
Laying of one number additional armoured / unarmoured power cable 1.1KV grade of size exceeding 25 sq. mm but not exceeding 120 sq. mm direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the pit etc. as required. SOR ITEM NO. 41.19 /Page 154

10

146

1460

... More
Laying of one number armoured / unarmoured power cable 1.1 KV grade of size exceeding 25 sq. mm but not exceeding 120 sq. mm. in the existing RCC Hume /Stone ware/G.I. Pipe/surface in existing trench as required. SOR ITEM NO. 41.22 /Page 154

70

35

2450

... More
Laying of one number armoured/unarmoured cable 1.1KV grade of size not exceeding 25 sq. mm on wall/truss with approved type of iron clamp etc. as required. SOR ITEM NO. 41.49 /Page 157

205

25

5125

... More
Laying of one number armoured/unarmoured cable 1.1KV grade of size exceeding 25 sq. mm but not exceeding 120 sq. mm on wall/truss with approved type of iron clamp etc. as required. SOR ITEM NO. 41.50 /Page 157

10

71

710

... More
Supplying and erection of water tight terminal box made of 16 SWG M.S. Sheet (1.6mm thick) i/c rubber gasket of required size suitable for kit kat/MCB/switch including 2 nos. pole clamp of M.S. flat iron size 32x3mm, nut and bolts, 4 Pole epoxy connector nut & bolt type, 30Amp, 500Volt. The box shall be powder coated excluding the cost of the kit kat/MCB/Switch complete as per specification. SOR ITEM NO. 42.13 /Page 164

4

910

3640

... More
meter panel - Supply, fixing, testing & commissioning wall/floor mounted LT panel primer coated with powder coated paint & provided with required gasket for dust/vermin proof with degree of protection IP42 suitable for 415Volt 3 phase, 50 Hz, 4 wire system fabricated out of CRCA sheet upto 2 mm thick (1.6 mm for doors) duly compartmentalized for incomer, bus section, outgoings, cable alleys & CT, PT Ampere Metre, Volt Metre, selector switches, frequency Metre, phase indicating lamp, Energy Metre complete including cost of busbar supports, detachable cable gland plates, 2 earthing terminals, internal wiring & fixing of separately supplied MCBs, MCCBs, ACB, panel mounted changeover switch/SFUs, etc. as required but excluding cost of busbar strips, Ampere Metre, Volt Metre, selector switch as per approved design & specification SOR ITEM NO. 29.27 /Page

100

397

39700

... More
Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification. SOR ITEM NO. 29.28 /Page

-

-

-

... More
Aluminium bus bar strips with PVC sleeves. SOR ITEM NO. 29.28.5 /Page

10

284

2840

... More
Supplying of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase & N, 4 pole, 50 Hz, 415 Volts, (Ics=100%Icu) AC supply with thermal-magnetic release having respective breaking capacity (KA) at 415 Volts cited against their range standard conforming to IS/IEC 60947-2 SOR ITEM NO. 27.3 /Page

-

-

-

... More
MCCB 25kA current rating - 200 Amp & adjustable overload setting 80% -100% of In, adjustable short circuit setting 6-10 In 4 Pole SOR ITEM NO. 27.3.4 /Page

1

19695

19695

... More
Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- :- SOR ITEM NO. 27.8 /Page 70

-

-

-

... More
Double pole SOR ITEM NO. 27.8.2 /Page 71 MCB DP For 40Amp 10kA rating SOR ITEM NO. 27.8.2.3 /Page 71

1

1329

1329

... More
Four pole SOR ITEM NO. 27.8.4 /Page 71 MCB FP 50Amp to 63 Amp 10kA rating SOR ITEM NO. 27.8.4.4/Page 95

5

2795

13975

... More
Supplying and drawing following pair, 0.5 mm PVC insulated copper conductor unarmoured telephone cable in existing surface/concealed, steel/PVC conduit as required. SOR ITEM NO. 38.2 /Page

-

-

-

... More
Telephone wire 0.5 mm, 2 Pair SOR ITEM NO. 38.2.2 /Page

70

36

2520

... More
Supply, installation testing and commissioning of telephone tag block krone connector with enclosure complete as mentioned below :- SOR ITEM NO. 38.4 /Page

-

-

-

... More
10 Pair SOR ITEM NO. 38.4.1 /Page

1

693

693

... More
Supply, fixing and testing of RJ 11 telephone jack modular (1 Module) SOR ITEM NO. 38.6 /Page

3

174

522

... More
Supplying, erection and testing of approved make wall mounting fan oscillating type with base, blades, guard, speed regulator etc. AC 230-250 volts with connections and including raw bolt/anchor hole fasteneretc. complete finished and as required. SOR ITEM NO. 30.2 /Page 92

-

-

-

... More
400mm sweep SOR ITEM NO. 30.2.2

2

2810

5620

... More
Supplying and drawing single core PVC insulated cable FR with copper multi strand conductor ISI marked in existing rigid PVC Casing-N-Capping / conduit in surface or concealed as per specification. SOR ITEM NO. 19 /Page 21

-

-

-

... More
2.5 Sq mm cable SOR ITEM NO. 19.2 /Page 21 (a) 1 X 2.5 sq mm SOR ITEM NO. 19.2.1 /Page 21

100

24

2430

... More
Supply, installation testing and commissioning RJ - 45 computer jack cat6 with shutter modular (1Module) SOR ITEM NO. 38.9 /Page

-

-

-

... More
RJ - 45 computer socket cat 6 with shutter modular (1Module) SOR ITEM NO. 38.9.1 /Page

8

288

2304

... More
Supplying and drawing 4 pair shielded twisted pair (STP), 0.5 mm PVC insulated copper conductor un-armoured Cat-6 computer cable FRLS in existing surface/concealed, steel/PVC. conduit/ casing-n-capping as required. SOR ITEM NO. 38.12 /Page

160

104

16640

... More
Supplying & fixing of fire extinguisher/refills as per IS specification SOR ITEM NO. 42.76. /Page 161 - 194

-

-

-

... More
ABC type duly refilled 6 Kg & ready to use SOR ITEM NO. 26.28.4

4

4629

18516

... More
Providing and fixing of carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube 30 cm long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS : 15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. SOR ITEM NO. 26.27 /Page 685

-

-

-

... More
Capacity 4.5 Kg. SOR ITEM NO. 26.27.3 /Page 685

4

11351

45404

... More
SPLIT AC (inverter model) :- Supply, installation, testing and commissioning of Split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with inverter based rotary compressor, copper condenser and first charge refrigerant R410A. The condensing unit working range should be capable for providing cooling between +/-5 deg. C to 50 deg. C & heating within 0 deg. C to 15 deg. C including connection of copper pipe of required size upto 3 mtr., insulation, cordless remote control, auto air swing louvers, wall stand for outdoor unit, connection copper lead wire, condensed water outlet pipe 2 mtr. complete etc as required. Outdoor/indoor units should be of same make (brand). SOR ITEM NO. 46.11 /Page 217 - 237

-

-

-

... More
SPLIT AC (inverter model, Cooling only) SOR ITEM NO. 46.11.2 /Page 217 - 237 1.5 TR star rating 5 star SOR ITEM NO. 46.11.2.4 /Page 217 - 237

2

52800

105600

... More
Cassette AC :- Supply installation testing and commissioning of split type ceiling cassette Slim line/floor standing air conditioning unit of capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A/ecofriendly green gas only, cordless remote control, auto air swing louvers, connection copper lead wire between outdoor and indoor unit, connection copper lead wire upto 1.5 mtr., excluding connection copper pipe of required size, insulation, floor stand for outdoor unit, condense water outlet complete etc as required. Outdoor/indoor units should be of same make (brand). SOR ITEM NO. 46.13 /Page 217 - 237

-

-

-

... More
Ceiling suspended/mounted cassette type 4 wayunit with inbuilt drain pump &decorative panels. SOR ITEM NO. 46.13.1 /Page 217 - 237 2.7/3.0 TR three phase SOR ITEM NO. 46.13.1.3 /Page 217 - 237

3

125091

375273

... More
Copper piping: - Supply, installation, testing and commissioning of interconnecting copper refrigerant pipe work (19mm/13mm thick) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. And exposed piping should be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as per specification. SOR ITEM NO. 46.30 /Page 217 - 237

-

-

-

... More
15.9 mm O.D. wall thickness ≥ 0.8mm (insulation – 13 mm thick) SOR ITEM NO. 46.30.9 /Page 217 - 237

35

874

30590

... More
9.5 mm O.D. wall thickness ≥ 0.8mm (insulation – 13 mm thick) SOR ITEM NO. 46.30.11 /Page 217 - 237

35

588

20580

... More
Drain piping :- Providing and fixing of CPVC, 6Kg/cm2 drain water piping with fittings, support and insulated with 6 mm thick closed cell elastomeric nitrile rubber insulation complete as per specification. SOR ITEM NO. 46.31 /Page 217 - 237

-

-

-

... More
20 mm dia ID SOR ITEM NO. 46.31.1 /Page 217 - 237

15

171

2565

... More
25 mm dia ID SOR ITEM NO. 46.31.2 /Page 217 - 237

25

202

5050

... More
Outdoor stand fabrication :- Supply, fabrication and erection of angle/channel/flat iron stand, hanging arrangement for air conditioning machines & ducts etc, back /support clamps or other similar work etc. including nut bolts of required size, making holes, fabrication, welding, cutting, etc. and painting with one coat of redoxide paint & two coat of enamel paintas required as per specification. SOR ITEM NO. 46.42 /Page 217 - 237

60

85

5100

... More
Supply, installation, testing, commissioning, and final testing of automatic lift complete in the shaft well and pit already constructed as per CPWD specification including automatic rescue device (ARD), All standard equipments, accessories and control equipments as per manufacturer's design and as per CPWD specification (Part III LIFTS) on turnkey basis, Conforming to NBC/statutory norms and ful filling following requirements. SOR ITEM NO. 44.1 (i) Type: Passenger lift. (ii) Load:As specified else where from 4 passengers (272Kg) to 26 passengers (1768Kg) (for each person standard weight 68Kg.). (iii) Speed: 1.00 metre/sec. or less as required. (iv) Control: ACV3F, 32bit microprocessor integrated serial communication control system with RMS (remote monitoring system)/BMS (building monitoring system) supporting software. (v) Motor/machine: Permanent magnetic synchronous gearless motor. (vi) Operation: Simplex collective selective with/without lift attendant. (vii) Total rise: About 3 mtrs.(approx) two stops only. (viii) Landings: All floors on sameside. (ix) Floors served : G+1. (x) Signals: Digital car position indicator, car travel direction indicator inside car & at all landings, voice annunciator with suitable music shall be provided in thelift (xi) Shaft size: As per manufacturer's design and as per CPWD specification (Part III LIFTS), Shaft to be constructed separately. (xii) Guide rail: As per manufacturer's specification. (xiii) Lift & car size: As per manufacturer's design and as per CPWD specification (Part III LIFTS). (xiv) Car entrance: As permanufacturer's design and as per CPWD specification (Part IIILIFTS). (xv) Landing entrance: As per manufacturer's design and as per CPWD specification (Part III LIFTS). (xvi) Car door: S.S. (stainless steel) hairline finish centre/telescopic opening door with visionpanel.(xvii)Landing door: S.S. (stainless steel) hairline finish centre/telescopic opening door with visionpanel. (xviii) Door operation: Automatic electric power operated door, full height infrared curtain with multiple criss/cross light beams .(xix) Car interior: S.S. (stainless steel) panel with hairline finish on all sides. (xx) Car floor: Anti skid PVC flooring on heavy duty M S (mildsteel) platform. (xxi) Car ceiling & lighting: S. S. (stainless steel) finish with aesthetic appearance with LED ceiling lights (xxii) Carventilation: Pressure fan/blower fan (car fan with automatic sleep timer shall be provided).(xxiii) Emergency lighting in car: Battery operated emergency lighting in the lift car. (xxiv) Intercom system: Battery operated intercom system in lift car, machine room and ground floor/controlroom.(xxv) Emergencyalarm: Battery operated alarm bell system in lift car & control room / ground floor.(xxvi) Position of machine room: Directly above the hoist-way.(xxvii) Electric power supply: AC 415 V, 3 phases 50 Hz & AC 230 V 1phase 50Hz terminated in machine room.(xxviii)Fire man switch : Fire man switch at machine room/terminal landing (xxix) All car panel buttons and all floor switches must be with Braille language as per lift act.(xxx) Audio visual indication in the lift car showing over loading shall be provided such that doors keep open till excess load is removed.(xxxi) Spring buffer/hydraulic buffer shall be provided (xxxii) Mechanical over speed governor, door key holes in the floor doors shall be provided.(xxxiii) Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the lift agency, along with the other steel structure works, foundations for the machines etc.(xxxiv) In the hoist way fascia plate shall be provided.(xxxv) Permanent wiring in lift machine room and lift well with proper no. of light points, with fixtures, exhaust fan, plug points and 3 phase 440V power supply shall be made in lift shaft by the department, machine room or at desired level.(xxxvi) Car top safety barricade shall be provided.(xxxvii) ARD (automatic rescue device): Solid state inbuilt automatic rescue device (ARD) automatically rescues passengers trapped in the lift car in between floors in the event of power failure. Automatic operation and immediate action in the event of mains failure, capable of moving the lift to the nearest landing, opens the automatic door of the lift car and floor. Sealed maintenance free battery backup with automatic charging unit and auto changeover device on mains failure.

-

-

-

... More
GATE - CENTER OPENING, 900mm, G+3, Well size 1900 X 2000mm 10 Passenger (680Kg.) SOR ITEM NO. 44.1.4

1

1530000

1530000

... More
Add extra to item no. 44.1 for every additional floor beyond initial G+ 1 floor (additional stops beyond two stops) provides all necessary additional parts/equipments as per manufacturer's requirement. SOR ITEM NO. 44.3

-

-

-

... More
Cost for each additional floor : upto 9 stops (For 4-10 Passengers) SOR ITEM NO. 44.3.1

2

67500

135000

... More
Add extra to item no. 44.1 for machine room less (MRL) lift in place of machine room directly above the hoist way. SOR ITEM NO. 44.4

-

-

-

... More
Extra cost for machine room less (4-13 Passenger) SOR ITEM NO. 44.4.1

1

135000

135000

... More
Add extra to item no. 44.1 for hall lantern and arrival gong system. SOR ITEM NO. 44.6

-

-

-

... More
Extra cost per lift (4-13 Passenger) SOR ITEM NO. 44.6.1

1

18000

18000

... More
Boring/drilling bore well of required dia perfectly vertical to receive casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. SOR I NO 16.1.1.3

-

-

-

... More
16.1.1.3 200 mm dia.

80

451

36080

... More
Boring/drilling bore well of required dia perfectly vertical to receive casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer –in-charge, beyond 90 metre depth below ground level.SOR I NO 16.1.1.

-

-

-

... More
16.1.1.2 150 mm dia.

170

413

70210

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed and approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire and labour charges, fittings and accessories, all complete, for all depths, as per direction of Engineer- in-charge.150 mm nominal size dia having minimum wall thickness 4.85 mmSOR I NO 16.5.2

20

1271

25420

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:150 mm dia SOR I NO 16.8.2

1

366

366

... More
Providing and fixing M.S. clamp of required dia made of 100 x10 mm flat to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts and nuts of required size complete. 16.9.2

1

1129

1129

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With well burnt bricks. SOR ITEM No. 19.30.1

2

20609

41218

... More
Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 metres. Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location with all lifts and lead upto 1000m as per relevent clauses of section-300 of specification..R.S.O.R Item 3.3

203.45

55

11189.75

... More
Granular Sub-base with Well Graded Material (CBR30 or more) (Table:- 400-1 & Table 400-2) Construction of granular sub-base by providing well graded material like natural sand crushed gravel or crushed stone having CBR 30, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator or plant mix method at OMC, and compacting with vibratory rollers of 80 to 100 kN static weight to achieve the desired density, complete as per Clause 401 of Specification. .R.S.O.R Item 4.1 Note :- This item can be executed only after prior written approval by C.E.

609.15

934

568946.1

... More
Dry Lean Cement Concrete Sub- base Construction of dry lean cement concrete Sub- base over a prepared sub-grade or drainage layer with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determinedduring trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver finisher with electronic sensor, compacting with 8- 10 tonnes vibratory roller, finishing and curing as per clause 601 of specification complete in all respect. R.S.O.R Item 6.1

29.25

2767

80934.75

... More
Cement Concrete Pavement Construction of un-reinforced, dowel jointed, plain cement concrete pavement M-30 grade concrete over a prepared sub base with cement , coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler,

-

-

-

... More
separation membrane, sealant primer, joint sealant, debonding strip, admixtures as approved, curing compound, finishing to lines and grades as per drawing as per IRC 15 2011 and as per relevant clauses of section 602 of specifications complete but excluding cost of steel in dowel bar and tie rods etc.. R.S.O.R Item 6.4

65.98

5685

375096.3

... More
Add extra in Item No.6.3, 6.4, 6.6 & 6.10 above for the cost of s including craddle, laps etc. complete required as per design. R.S.O.R Item 6.8

0.5

68297

34148.5

... More
Providing and laying reinforced cement concrete pipe 300mm dia NP-4 for service ducts below concrete pavement. R.S.O.R Item 6.15

20

713

14260

... More
Providing,fixing and lowering,laying and jointing double walled corrugated(DWC) pipes of HDPE in 6m lenghth bar with IS-14930-II in prepared trenches in grade and level including cost of couplers and testing of pipes at factory as per the stipulation in relevant IS codes etc. complete. 145mm outer diameter/123mm inner diameter.S.O.R Item 6.16(i)

20

399

7980



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.