MP Power Transmission Company Limited Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

MP Power Transmission Company Limited - MPPTCL Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date9 Jul 2024
Closing Date7 Aug 2024
Tender Amount₹ 97,27,000 
Notes
Download

Costs

  • EMD

    ₹ 1,94,540
  • Document Cost

    ₹ 2,360
  • Tender Fee

    ₹ 1,148

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
3004747,2.7.1, Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over ….. ... be levelled and neatly dressed. Ordinary rock

40

8120

203

... More
3004838,4.1.2.3,Providing and laying in position CC of specified….All work up to plinth level With 40mm nominal size graded stone aggregate.

38

132012

3474

... More
3004924,5.16.1,Reinforcement for R.C.C. work including ,….Specification”)Mild steel and Medium Tensile steel bars.

3000

180000

60

... More
3004929,5.16.6,Reinforcement for R.C.C. work in/c straightening, cutting,….in/c cost of binding wire up to floor two level including all wastage etc. complete Thermo-Mechanically Treated bars.(TMT)

18000

1132200

62.9

... More
3004894,5.9.2,Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters butteresses, plinth beams and string courses etc.up to plinth level.

650

142350

219

... More
3004899,5.9.5,Centering and shuttering in cluding strutting, propping etc. and removal of form for: Lintels, beams, girders, bressumers and cantilevers

130

46280

356

... More
3004884,5.1.1,P/ laying in position specified grade of RCC (with 20mm ...stone aggregate) ex/c the cost of centering, …. reinforcement - All work up to plinth level : M 20 –Grade Concrete

176

1020096

5796

... More
3004886,5.2.1,"Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and" string courses, fillets, columns, pillars, posts and struts etc. above plinth level and upto floor two level excluding cost of centering, shuttering, finishing and reinforcement: M-20 Grade Concrete

66

387090

5865

... More
3006147,13.2.2,15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement : 6 sand)

2500

370000

148

... More
3006149,13.3.2,20 mm cement plaster of mix : 1:6 (1 cement : 6 sand)

2600

512200

197

... More
3005665,10.2,Structural steel work using M.S. flats, angles, …. of approved steel primer all complete.

1200

82800

69

... More
3004893,5.9.1,Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for concrete upto plinth level

180

34308

190.6

... More
3004900,5.9.6,Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts.

1200

565440

471.2

... More
3004994,6.5.2,Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete. Cement Mortar 1:6 (1 cement: 6 sand).

80

332400

4155

... More
3004996,6.6.2,Brick work with well brunt open bhatta, bricks, ... up to floor two level i/c curing etc complete.Cement Mortar 1:6 (1 cement : 6 sand)

310

1348500

4350

... More
3004843,4.2.1.3,Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto floor two level, excluding the cost of centering, shuttering and finishing : With 20mm nominal size graded stone aggregate M 15 – Grade concrete

7

32998

4714

... More
3006241,13.65,Painting with synthetic enamel paint of approved …... new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.

200

15400

77

... More
3006220,13.53,Finishing walls by any mechanical or manual means with Premium Acrylic Smooth exterior paint (Premium exterior) of required shade including all scaffolding. New work ......0.5mm on horizontal surfaces with an elongation of 150% and water proofing of upto 3 bars on vertical surface)

4500

585000

130

... More
3005738,10.36,Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 90 m), having 50 nos rounds per 6 metre length, .....with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost ofM.S. angle, C.C. blocks shall be paid separately).

720

198000

275

... More
3005696,10.14.2,Steel work in built up M.S. tubular section (round, square or rectangular hollow tubes etc.) trusses/frame work etc…..etc. complete. Hot finished seamless type tubes

800

87200

109

... More
3006034,12.32.2,Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes…. 10 mm gap for thermal expansion. 110 mm diameter (minimum wall thickness 2.2mm)

150

35700

238

... More
3004796,2.27.1,Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete. With hard muram having.....dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm)

450

135000

300

... More
3000150,NSSOR,P&F Barbed wire (9.38 Kg per 100 M min.) to MS Angle Iron posts including screwing with GI tying wire staples or steel pins I/c cost of wire, staples pins etc. as per the direction of Engineer-In- Charge

5040

40320

8

... More
3006442,15.6.3,02 No. Guard CHEAK POST Demolishing brick work manually/ by mechanical….lead as per direction of Engineer-in- Charge...In cement mortar.

4

1948

487

... More
3006435,15.2.1,Demolishing cement concrete manually/by…... Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix).

6

3468

578

... More
3004746,2.6.1,Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over ........disposed earth to be levelled and neatly dressed All kinds of soil

15

1935

129

... More
3004747,2.7.1, Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over ….. ... be levelled and neatly dressed. Ordinary rock

5

1015

203

... More
3004838,4.1.2.3,Providing and laying in position CC of specified….All work up to plinth level With 40mm nominal size graded stone aggregate.

1

3474

3474

... More
3004924,5.16.1,Reinforcement for R.C.C. work including ,….Specification”)Mild steel and Medium Tensile steel bars.

100

6000

60

... More
3004929,5.16.6,Reinforcement for R.C.C. work in/c straightening, cutting,….in/c cost of binding wire up to floor two level including all wastage etc. complete Thermo-Mechanically Treated bars.(TMT)

800

50320

62.9

... More
3004894,5.9.2,Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters butteresses, plinth beams and string courses etc.up to plinth level.

12

2628

219

... More
3004897,5.9.3,Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform.

26

11429

439.6

... More
3004899,5.9.5,Centering and shuttering in cluding strutting, propping etc. and removal of form for: Lintels, beams, girders, bressumers and cantilevers

14

4984

356

... More
3004900,5.9.6,Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts.

24

11308

471.2

... More
3004884,5.1.1,P/ laying in position specified grade of RCC (with 20mm ...stone aggregate) ex/c the cost of centering, …. reinforcement - All work up to plinth level : M 20 –Grade Concrete

5

28980

5796

... More
3004886,5.2.1,"Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and" string courses, fillets, columns, pillars, posts and struts etc. above plinth level and upto floor two level excluding cost of centering, shuttering, finishing and reinforcement: M-20 Grade Concrete

6

35190

5865

... More
3006147,13.2.2,15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement : 6 sand)

60

8880

148

... More
3006149,13.3.2,20 mm cement plaster of mix : 1:6 (1 cement : 6 sand)

60

11820

197

... More
3004893,5.9.1,Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for concrete upto plinth level

10

1906

190.6

... More
3004792,2.24,Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, …..each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

4

288

72

... More
3004994,6.5.2,Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete. Cement Mortar 1:6 (1 cement: 6 sand).

2

8310

4155

... More
3004996,6.6.2,Brick work with well brunt open bhatta, bricks, ... up to floor two level i/c curing etc complete.Cement Mortar 1:6 (1 cement : 6 sand)

6

26100

4350

... More
3004843,4.2.1.3,Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, …….shuttering and finishing : With 20mm nominal size graded stone aggregate M 15 – Grade concrete

1

4714

4714

... More
3006241,13.65,Painting with synthetic enamel paint of approved …... new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.

10

770

77

... More
3006220,13.53,Finishing walls by any mechanical or manual means with Premium Acrylic Smooth exterior paint (Premium exterior) of required shade including all scaffolding. New work ......0.5mm on horizontal surfaces with an elongation of 150% and water proofing of upto 3 bars on vertical surface)

60

7800

130

... More
3006211,13.46,Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work

60

3840

64

... More
3005920,11.78.1.1,Providing and laying vitrified floor tiles Multi/Double charged (Minimum top layer thickness 2.0mm) Neno Polished self ......white cement and matching pigments etc. complete In light shade glossy/ rustic /stain finished Size 600X600 mm thickness 9-10 mm

12

13248

1104

... More
3005854,11.35,Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement …...with base of cement mortar 1 : 4 (1 cement : 4 sand) 25 mm thick.(Area of slab to be over 0.25 sqm)

2

1860

930

... More
3005212,9.18.2,Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, .....cross bands and face veneers on both faces of shutter. 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.

3

7110

2370

... More
3006206,13.41,Providing and applying white cement based putty of average thickness 1 mm, of approved ….. walls, for application on the exterior walls prior permission of APD/Chief Engineer will be required.

120

8880

74

... More
3005706,10.22.2,Steel work welded in built up sections/ framed ….etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

100

8500

85

... More
3006034,12.32.2,Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm diameter (minimum wall thickness 2.2mm)

4

952

238

... More
3004796,2.27.1,Supplying and filling in plinth under floors including watering ramming consolidating in …...dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm)

10

3000

300

... More
3009392,30.1.2,Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, ……...1200 mm Sweep, with minimum air delivery 210 m³/min and service value ≥ 4.00 as per BEE..

2

3336

1668

... More
3009432,31.3.4,Supply and fixing Led tube rod comprising of LED tube with non-integral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy 100 lm/Watt. LED driver PF 0.95 & THD 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.Tube light LED 1 X 20/22Watt, Integral i/c batten aluminium body, PC diffuser.

4

3128

782

... More
3008184,5.1.1.1,Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary short point. (Using modular accessories)

8

2144

268

... More
3008185,5.1.1.2,Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary medium point. (Using modular accessories)

8

3768

471

... More
3008186,5.1.1.3,Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary long point. (Using modular accessories)

2

1374

687

... More
3008191,5.1.3.2,Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- 3 Pin 6 Amp socket outlet on separate board Medium point. (Using modular accessories)

2

1200

600

... More
3008199,5.2,Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside casing & capping with required materials as per specification on same board. .(Using modular accessories)

2

448

224

... More
3008180,5.3.1,Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping of ISI marked suitable size etc. as required as per specification 2x2.5 Sq.mm ( Using flush type normal accessories)

40

2840

71

... More
3009107,27.8.1.2,Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- Single pole MCB SP 6Amp to 32Amp 10kA rating

2

272

136

... More
3009366,29.25.2,Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing board 100 Watt (2 module)

2

780

390

... More
3008368,18.3.1,Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-1 Or 2 Module PVC box

2

152

76

... More
3008371,18.3.4,Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-6 Module PVC box

2

276

138

... More
3004746,2.6.1,CULVERT Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over ........disposed earth to be levelled and neatly dressed All kinds of soil

40

5160

129

... More
3004838,4.1.2.3,Providing and laying in position CC of specified….All work up to plinth level With 40mm nominal size graded stone aggregate.

3

10422

3474

... More
3004929,5.16.6,Reinforcement for R.C.C. work in/c straightening, cutting,….in/c cost of binding wire up to floor two level including all wastage etc. complete Thermo-Mechanically Treated bars.(TMT)

1400

88060

62.9

... More
3004894,5.9.2,Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters butteresses, plinth beams and string courses etc.up to plinth level.

55

12045

219

... More
3004884,5.1.1,P/ laying in position specified grade of RCC (with 20mm ...stone aggregate) ex/c the cost of centering, …. reinforcement - All work up to plinth level : M 20 –Grade Concrete

31

179676

5796

... More
3004893,5.9.1,Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for concrete upto plinth level

10

1906

190.6

... More
3004796,2.27.1,Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete. With hard muram having CBR 12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm)

10

3000

300



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.