MP Power Transmission Company Limited Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
MP Power Transmission Company Limited - MPPTCL Tender
Electrical and Electronics
Eprocure
Opening Date18 Jun 2024
Closing Date22 Jul 2024
Tender AmountRefer Documents
Costs
EMD
₹ 4,500Document Cost
₹ 590Tender Fee
₹ 295
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MPPTC_351794_1Bid Award Id
ViewTender No
TS-02/2024-25Tender Authority
MP Power Transmission Company Limited ViewPurchaser Address
-Website
http://http://www.mptransco.in/Tender/Tender
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Strining of Twin Zebra Conductor
100
12600
126
Strining of Single Zebra Conductor
300
19500
65
Strining of Over Head Earth Wire
500
12500
25
INSTALLATION AND ERECTION OF OUTDOOR/INDOOR EQUIPMENTS
-
-
-
Erection of 33 KV CB
Unloading of material and stacking at site store followed by shifting of material at the location of its erection.Erection on structures and alignment, shifting of breaker upto the place and placement of all 3 circuit breaker poles on structure and alignment. Complete assembly of circuit breaker including erection of control cabinet & mechanism box, interconnecting piping work, erection of all accessories for the equipment.
1
12000
12000
ERECTION OF 33 KV CT/NCT
Unloading of material and stacking at site store followed by shifting of material at the location of its erection.Shifting on current X’mer upto civil foundation and placement on structure and fixing of junction box including all accessories etc.
3
10800
3600
ERECTION OF 33 KV Isolator With Earth Switch & With Out Earth Switch
Unloading of material and stacking at site store followed by shifting of material at the location of its erection.Shifting upto civil foundation (Including erection of ISOLATORS STRUCTURES (Approx 0.27 MT) )& Placement of complete isolator in all 3 phases of Isolator structure including shifting within s/s premises. Erection / Mounting of mechanism box,PI, MOTORISED ARRANGEMENTS, interconnection, piping alignment of contacts & all associated activities .
3
32400
10800
ERECTION OF 33 KV LA
Unloading of material and stacking at site store followed by shifting of material at the location of its erection.Shifting & placement of LA's on structure including all accessories, making all interconnections checking & installation of insulator base and surge counters.
3
7200
2400
ERECTION OF 33 KV SOLID CORE INSULATOR FOR SUBSTATION WORK
6
4320
720
ERECTION OF 33 KV C&R Panel Unloading /Shifting up to control room (including storage if required) and placement complete with all relays & accessories. The placement of C&R panel to be done on MS channel frame and MS Channel frame will suitable grouted in control room as per drawing.The cutting,welding & fabrication of of MS channel frame is to be done as per drawing.Proper alignment of C&R panel to be done.The earthing of C&R Panel to be done.Making of all interconnections for the control & relay panel on terminal block as per drawing including all AC & DC connections.
1
7800
7800
Complete Fitting of Lightning Fixtures
5
2400
480
CABLE LAYING
Unloading of material and stacking at site store followed by shifting of material at the location of its erection.Laying of copper cables (armoured/unarmoured) on racks/cable trays/ angle support overhead racks conduits including dressing of cables with accessories for copper conductor & armoured control cables.
-
-
-
Cable Laying 2 core cable x 2.5/ sq.mm Unarmoured
500
5000
10
Cable Laying 4 core cable x 2.5/ sq.mm Unarmoured
1000
12000
12
Cable Laying 8 core cable x 2.5/ sq.mm Unarmoured
500
7000
14
Cable Laying 12 core cable x 2.5/ sq.mm Unarmoured
500
9000
18
CABLE TERMINATION
Cable termination including providing of holes for cable entry, fixing of glands, dressing of cable leads, fixing of lugs etc for each type of control cable including termination at both ends.
-
-
-
Cable Termition 2 core x 2.5/ sq.mm Unarmoured
5
510
102
Cable Termition 4 core x 2.5/ sq.mm Unarmoured
4
480
120
Cable Termition 8 core x 2.5/ sq.mm Unarmoured
2
360
180
Cable Termition 12 core x 2.5/ sq.mm Unarmoured
2
480
240
M S FLAT LAYING
Unloading of material and stacking at site store followed by shifting of material at the location of its erection.Laying of MS flat duly buried at a depth of 0.5 MTRs provinding of risers for structures earthing including back filling, welding etc structure earthing of following length
-
-
-
Earthing Installation M.S. Flat (65X8)
123
9594
78
Earthing Installation M.S. Flat (50X6)
212
12720
60
INSTALLATION OF EARTHING
Installation of 25mm dia, 3000 mm long MS rod with electrodes by directly driving/drilling (6'' Dia) to in dril including excavation (if rspective of type of solid incounterd), back filling with bentolle soil, welding to etc.
10
10800
1080
PREPARATION OF EARTH PIT Preparation of earthing pits (1.5 m*1.5m*3m) as per boards drawing nosXII-B-774 with include excavation of the soil encountered ambedding of 4 nos GI pipes of size 40*3MTR. Long back filling with Black soil.
1
10800
10800