MP Power Transmission Company Limited Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
MP Power Transmission Company Limited - MPPTCL Tender
Eprocure
Opening Date28 May 2021
Closing Date12 Jul 2021
Tender Amount₹ 8,76,555 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 20,935Document Cost
₹ 1,120Tender Fee
₹ 295
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_MPPTC_144145_1Bid Award Id
ViewTender No
CE(TandC)/TS-59/2021/300Tender Authority
MP Power Transmission Company Limited ViewPurchaser Address
-Website
http://http://www.mptransco.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(SOR No. 5.1.1) Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : M 20 Nominal mix
73
-
4581.9
(SOR No. 5.16.6AAA) Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire up to floor two level incl. all wastage etc. complete. Thermo -Mechanically Treated bars.(TMT)
2628
-
60
(SOR No. 5.16.1A) Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire up to floor two level including all wastage etc. complete. Mild steel and Medium Tensile steel bars.
292
-
54.45
(SOR No. 5.9.1) Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete up to plinth level.
386.25
-
156.6
(NSOR) Labour only for fixing of nuts & bolts required for structural foundation work as per the direction of Engineer in Charge. ( Base Rate Rs. 8/- Kg)
504
-
8
(SOR No. 2.25) Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
204
-
64.8
(SOR No. 10.22.1) Steel work welded in built up section/ framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structure steel etc. as required. In Stringers, treads landings etc. of stair cases including use of chequered plate wherever required, all complete.
400
-
77.27
(NSOR) Supply and spreading in EHV Substation yard or road works, with hard moorum/hard copra having maximum dry density not less than 2 MT per cum with stacking, boxing, including cost of material, Compaction with watering (Minimum compaction 95% of MDD), T&P, Royalty all & lift etc. complete in layers not exceeding 200 mm, as per specifications and direction of Engineer in Charge. (Base Rate Rs. 292/- per Cum)
500
-
292
(NSOR) Providing & laying stone crusher dust (1st layer) and mix of stone crusher dust & cement (2nd layer) in substation yard as indicated below (applicable for other than B.C. soil strata) :(a) 1st layer : Providing & Laying stone crusher dust (free from organic matter and foreign matter etc.) of average thickness 50 mm
(b) 2nd layer : Providing & Laying mixture of stone crusher dust (free form organic matter and foreign matters etc.) and cement in ratio of 1:14 (1 cement : 14 stone crusher dust, the quantity of cement shall not be less than 1 standard bag of 50 kg. ...... (Base Rate combined for both the layers, @ Rs. 93/- per Sqm)
600
-
93
(NSOR) Supply, stacking and spreading of 40 mm crusher broken metal black trap, basalt or granite uniformly in substation yard in desired thickness, free from dust and foreign matter, including transportation up to site, lead and lift, T&P labour royalty and taxes etc. complete as directed by Engineer in Charge. (Base Rate Rs. 1003/- per Cum)
50
-
1003
(SOR No. 11.74) Providing and laying factory made coloured chamfered edge cement concrete paver blocks of required strength, thickness and size/shape, made by table vibratory method using PU mould, laid in required colour and pattern over 50 mm thick compacted bed of stone dust, compacting and proper embedding/laying of inter locking paver blocks into the bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand including locking edges with M 15 cement concrete in complete as per manufacture's specifications and direction of Engineer-in-charge. 60 mm thick C.C. paver block of M-35 grade with approved colour, design and pattern.
80
-
631.8
(SOR No. 13.70.2) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
78
-
47.7
(SOR No. 11.84) Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
3
-
6097.5
(SOR No. 18.9.3) P/F Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply ……. complete as per direction of Engineer in Charge 25 mm nominal outer dia .Pipes.
150
-
166.5
(SOR No. 18.9.1) P/F Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply ……. complete as per direction of Engineer in Charge15 mm nominal outer dia .Pipes.
20
-
109.8
(SOR No. 18.34.1) Providing and fixing CPVC gate valve with knob of approved quality. 25 mm nominal bore
10
-
385.2