Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
MP Power Transmission Company Limited - MPPTCL Tender
Civil And Construction
Eprocure
Opening Date31 Jul 2024
Closing Date20 Aug 2024
Tender Amount₹ 18,63,850
Costs
EMD
₹ 44,000Document Cost
₹ 1,180Tender Fee
₹ 295
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MPPTC_360941_1Bid Award Id
ViewTender No
TS-01/2024-25Tender Authority
MP Power Transmission Company Limited ViewPurchaser Address
-Website
http://http://www.mptransco.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Online NIT for unexecuted balance erection work of 220KV Main Bus-2, 220KV Bus Tie, 220KV Bus Coupler, 132KV Bus Coupler and 132KV Bus Sectionalizer at 220KV Substation Narsinghpur under Testing Dn. Narsinghpur
Tender Document for unexecuted balance erection work of 220KV Main Bus-2, 220KV Bus Tie, 220KV Bus Coupler, 132KV Bus Coupler and 132KV Bus Sectionalizer at 220KV Substation Narsinghpur under Testing Dn. Narsinghpur
BOQ Items
Stringing of overhead gantries,vertical droppers with ACSR conductor including fixing of insulator string, sapcers, calmp etc. ACSR Twin Zebra Conductor
1100
138600
126
220KV EQUIPMENTS, 220KV Circuit Breakers (3 Phase) -Shifting within Sub-station premises and placment of all 3No. poles of C.B. on Structure. Complete assembly of Circuit breaker including errection of control cabinet and mechanism box,interconnecting piping work,errection of all accesories for the equipment. SF6 gas filling for which gas cylinder and filling equipments shall be provided by MPPTCL
1
37200
37200
220KV Current Transformer Ratio:800-400/1-1-1-1-1 Amp. -Shifting of 220KV CT.upto Civil foundation and placement on stucture and fixing of Junction Box, including all accessories,making all jumpers etc.
3
36000
12000
Dismentling of 220 KV PT installed in 220KV main bus No. 2 side.
3
18000
6000
Shifting & Installation of 220 KV PT and placement on structure and fixing of all accessories, making all interconnections jumper etc.
3
36000
12000
220 KV Isolator without Earth switch (3-Phase) - Shifting upto Civil foundation and placement of complete isolator in all three phase of isolator structure with Solid core Insulators . Erection / mounting of mechanism box ,interconnection pippnig alignment of contacts and all associated activities to make the installtion complete including checking of successful technical and electrical operation.
15
450000
30000
Solid core Insulators for supporting PI - Erection of 220KV Post Insulator/Solid core Insulator, their Connections and shifting within sub-staion permises.
62
111600
1800
220KV Control & Relay Panels for 220KV Bus Tie Feeder- Shifting up to Control room(including Storage if required) & placment complet with all relays and accesories. The placement of C&R panel to be done on MS channel frame and MS channel frame will be suitably grouted in control room as per drawing.Proper alignment of C&R panel to be done. The earthing of C&R panel to be done.
1
15600
15600
Shifting of 132KV CT.upto Civil foundation and placement on stucture and fixing of Junction Box, including all accessories,making all jumpers etc. 132KV Current Transformer Ratio: 800/1-1-1 Amp.
3
21600
7200
132 KV Isolator without Earth switch (3-Phase) Placement of complete isolator with Post insulator in all three phase of isolator structure. Erection / mounting of mechanism box ,interconnection pippnig alignment of contacts and all associated activities to make the installtion complete including checking of successful technical and electrical operation.
4
72000
18000
Solid core Insulators for supporting PI - Erection of 132KV Post Insulator/Solid core Insulator, their Connections and shifting within sub-staion permises.
9
12960
1440
Shifting of 132 kv control relay pannel up to Control room(including Storage if required) & placement complet with all relays and accesories. The placement of C&R panel to be done on MS channel frame and MS channel frame will be suitably grouted in control room as per drawing.Proper alignment of C&R panel to be done. The earthing of C&R panel to be done.
1
9600
9600
Erection of Junction Box 128Way & 64Way with complete installation with Earthing
3
3600
1200
Cable Laying/Installation - Laying of copper cables (armoured/unarmoured) on racks/angles support Over head racks,conduits including dressing of cables with accessories for copper conductor & armoured control cables. 2Core x 2.5 Sq. mm
1000
10000
10
Cable Laying/Installation - Laying of copper cables (armoured/unarmoured) on racks/angles support Over head racks,conduits including dressing of cables with accessories for copper conductor & armoured control cables. 4Core x 2.5 Sq. mm
2500
30000
12
Cable Laying/Installation - Laying of copper cables (armoured/unarmoured) on racks/angles support Over head racks,conduits including dressing of cables with accessories for copper conductor & armoured control cables. 8Core x 2.5 Sq. mm
1000
14000
14
Cable Laying/Installation - Laying of copper cables (armoured/unarmoured) on racks/angles support Over head racks,conduits including dressing of cables with accessories for copper conductor & armoured control cables. 12Core x 2.5 Sq. mm
2000
36000
18
Cable Laying/Installation - Laying of copper cables (armoured/unarmoured) on racks/angles support Over head racks,conduits including dressing of cables with accessories for copper conductor & armoured control cables. 19Core x 2.5 Sq. mm
2000
60000
30
Providing Holes for cable entry, fixing of glands, dressing of cable leads, fixing of tags 2Core x 2.5 Sq. mm
6
612
102
Providing Holes for cable entry, fixing of glands, dressing of cable leads, fixing of tags 4Core x 2.5 Sq. mm
20
2400
120
Providing Holes for cable entry, fixing of glands, dressing of cable leads, fixing of tags 8Core x 2.5 Sq. mm
8
1440
180
Providing Holes for cable entry, fixing of glands, dressing of cable leads, fixing of tags 12Core x 2.5 Sq. mm
8
1920
240
Providing Holes for cable entry, fixing of glands, dressing of cable leads, fixing of tags 19Core x 2.5 Sq. mm
8
3360
420
Earthing Installation -installation of 25mm dia 3000mm long MS rod earth electrodes by directly driving/ drilling (6''dia) in to earth including excavation(irrespective of soil encounterd), back filling with bentonite soil,welding to earth conductor etc.
15
16200
1080
Laying of MS Flat and making earth mat (duly buried at a depth of 0.5 mtrs.) including back filling welding etc. and bolting of risers to the structures/ eqipments at desired place: M.S.Flat 75X8mm
400
38400
96
Laying of MS Flat and making earth mat (duly buried at a depth of 0.5 mtrs.) including back filling welding etc. and bolting of risers to the structures/ eqipments at desired place: M.S.Flat 65X8mm
200
15600
78
Laying of MS Flat / steel risers including welding etc. and bolting of risers to the structures/ eqipments at desired place: M.S.Flat 50X6mm
1500
90000
60
Preparation of pits(1.5x1.5x3Mtrs) as per Board's drawing No.XII-B-774 which includes excavation (irrespective of the soil encountered) embedding of 4 Nos GI Pipes of size 40mm dia 4 mm thickness along with clamp for earth pit back filling with black cotton soil free from boulder & harmful mixture and costruction of brick for earth pit.These GI Pipes are to be welded with MS Flat by making mesh frame and cutting of pipes as also making oles in the pipes for water seepage . the earth pit is to be connected with earth mesh of MS flat in four directions directly on pipe
2
21600
10800