Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

MP Power Transmission Company Limited - MPPTCL Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date13 Feb 2024
Closing Date12 Mar 2024
Tender AmountRefer Documents 
Notes
Download

Costs

  • EMD

    ₹ 6,650
  • Document Cost

    ₹ 590
  • Tender Fee

    ₹ 295

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
132KV Equipments:- All the connections and jumper of old 132 KV CT from bay have to be removed and dismantled from the Structure and kept at the designated place.

3

10800

3600

... More
132KV Equipments:- Shifting of 132 KV isolator upto civil foundation & placements of complete isolator in all 3 phase of isolator structure.

1

18000

18000

... More
132KV Equipments:- All the connections and jumper of old 132 KV Isolator from bay have to be removed and dismantled from the Structure and kept at the designated place.

1

9000

9000

... More
132KV Equipments:- Shifting of 132 KV LA upto civil foundation & placement on structure including all accessories etc.

3

14400

4800

... More
132KV Equipments:- All the connections and jumper of old 132 KV LA from bay have to be removed and dismantled from the Structure and kept at the designated place.

3

7200

2400

... More
33KV Equipments :- Shifting of 33 KV CT upto civil foundation and placement on structure including all accessories etc.

3

10800

3600

... More
33KV Equipments :- All the connections and jumper of 33 KV CT from bay have to be removed and dismantled from the Structure and kept at the designated place.

3

5400

1800

... More
33KV Equipments :- Shifting of 33 KV isolator upto civil foundation & placements of complete isolator in all 3 phase of isolator structure.

1

10800

10800

... More
33KV Equipments :- All the connections and jumper of 33 KV Isolator from bay have to be removed and dismantled from the Structure and kept at the designated place.

1

5400

5400

... More
33KV Equipments :- Shifting of 33 KV LA upto civil foundation & placement on structure including all accessories etc.

3

7200

2400

... More
33KV Equipments :- All the connections and jumper of old 33 KV LA from bay have to be removed and dismantled from the Structure and kept at the designated place.

3

3600

1200

... More
Cable laying and associate works :- Laying of copper cables (armoured/unarmoured) on racks/cable trays/ angle support overhead racks conduits including dressing of cables with accessories for copper conductor & armoured control cables. Details of cables to be provided are as under: 2 Core x 2.5 Sq.mm. (Unarmoured)

500

5000

10

... More
Cable laying and associate works :- Laying of copper cables (armoured/unarmoured) on racks/cable trays/ angle support overhead racks conduits including dressing of cables with accessories for copper conductor & armoured control cables. Details of cables to be provided are as under: 4 Core x 2.5 Sq.mm. (Unarmoured)

500

6000

12

... More
Cable laying and associate works :- Laying of copper cables (armoured/unarmoured) on racks/cable trays/ angle support overhead racks conduits including dressing of cables with accessories for copper conductor & armoured control cables. Details of cables to be provided are as under: 8 Core x 2.5 Sq.mm. (Unarmoured)

500

7000

14

... More
Cable laying and associate works :- Laying of copper cables (armoured/unarmoured) on racks/cable trays/ angle support overhead racks conduits including dressing of cables with accessories for copper conductor & armoured control cables. Details of cables to be provided are as under: 12 Core x 2.5 Sq.mm. (Unarmoured)

500

9000

18

... More
Cable laying and associate works :- Laying of copper cables (armoured/unarmoured) on racks/cable trays/ angle support overhead racks conduits including dressing of cables with accessories for copper conductor & armoured control cables. Details of cables to be provided are as under: 19 Core x 2.5 Sq.mm. (Unarmoured)

500

15000

30

... More
Cable terminations including fixing of cable glands, lugs etc. for each type of control/ power cables, including terminations at both ends. I.R. value between cores and I.R. value with respect to its armouring is to be verified. The continuity of all cores is also to be verified. Both work to be done before connecting cable to the terminal block. Making suitable hole in bottom/side plate of C&R panel, AC/DC Board, Marshaling box, CT/PT sec box and CB mechanism box for fixing cable glands in addition to cable gland holes already provided. The hole should be free from burrs. Fixing all cables in respective cable glands and refixing gland plate to its original place. All cable identification plate is to be provided on both ends of each cable. Stripping of outer insulation cover , armouring etc. of cable, fixing ferrules on each core at both ends. Stripping all cores to suitable length, making eye, crimping terminal lugs (as the case may be ) and fixing it to terminal block as per drawing followed by proper bending/ dressing of all cores. 2 Core x 2.5 Sq.mm. (Unarmoured)

4

408

102

... More
Cable terminations including fixing of cable glands, lugs etc. for each type of control/ power cables, including terminations at both ends. I.R. value between cores and I.R. value with respect to its armouring is to be verified. The continuity of all cores is also to be verified. Both work to be done before connecting cable to the terminal block. Making suitable hole in bottom/side plate of C&R panel, AC/DC Board, Marshaling box, CT/PT sec box and CB mechanism box for fixing cable glands in addition to cable gland holes already provided. The hole should be free from burrs. Fixing all cables in respective cable glands and refixing gland plate to its original place. All cable identification plate is to be provided on both ends of each cable. Stripping of outer insulation cover , armouring etc. of cable, fixing ferrules on each core at both ends. Stripping all cores to suitable length, making eye, crimping terminal lugs (as the case may be ) and fixing it to terminal block as per drawing followed by proper bending/ dressing of all cores. 4 Core x 2.5 Sq.mm. (Unarmoured)

4

480

120

... More
Cable terminations including fixing of cable glands, lugs etc. for each type of control/ power cables, including terminations at both ends. I.R. value between cores and I.R. value with respect to its armouring is to be verified. The continuity of all cores is also to be verified. Both work to be done before connecting cable to the terminal block. Making suitable hole in bottom/side plate of C&R panel, AC/DC Board, Marshaling box, CT/PT sec box and CB mechanism box for fixing cable glands in addition to cable gland holes already provided. The hole should be free from burrs. Fixing all cables in respective cable glands and refixing gland plate to its original place. All cable identification plate is to be provided on both ends of each cable. Stripping of outer insulation cover , armouring etc. of cable, fixing ferrules on each core at both ends. Stripping all cores to suitable length, making eye, crimping terminal lugs (as the case may be ) and fixing it to terminal block as per drawing followed by proper bending/ dressing of all cores. 8 Core x 2.5 Sq.mm. (Unarmoured)

16

2880

180

... More
Cable terminations including fixing of cable glands, lugs etc. for each type of control/ power cables, including terminations at both ends. I.R. value between cores and I.R. value with respect to its armouring is to be verified. The continuity of all cores is also to be verified. Both work to be done before connecting cable to the terminal block. Making suitable hole in bottom/side plate of C&R panel, AC/DC Board, Marshaling box, CT/PT sec box and CB mechanism box for fixing cable glands in addition to cable gland holes already provided. The hole should be free from burrs. Fixing all cables in respective cable glands and refixing gland plate to its original place. All cable identification plate is to be provided on both ends of each cable. Stripping of outer insulation cover , armouring etc. of cable, fixing ferrules on each core at both ends. Stripping all cores to suitable length, making eye, crimping terminal lugs (as the case may be ) and fixing it to terminal block as per drawing followed by proper bending/ dressing of all cores. 12 Core x 2.5 Sq.mm. (Unarmoured)

12

2880

240

... More
Cable terminations including fixing of cable glands, lugs etc. for each type of control/ power cables, including terminations at both ends. I.R. value between cores and I.R. value with respect to its armouring is to be verified. The continuity of all cores is also to be verified. Both work to be done before connecting cable to the terminal block. Making suitable hole in bottom/side plate of C&R panel, AC/DC Board, Marshaling box, CT/PT sec box and CB mechanism box for fixing cable glands in addition to cable gland holes already provided. The hole should be free from burrs. Fixing all cables in respective cable glands and refixing gland plate to its original place. All cable identification plate is to be provided on both ends of each cable. Stripping of outer insulation cover , armouring etc. of cable, fixing ferrules on each core at both ends. Stripping all cores to suitable length, making eye, crimping terminal lugs (as the case may be ) and fixing it to terminal block as per drawing followed by proper bending/ dressing of all cores. 19 Core x 2.5 Sq.mm. (Unarmoured)

8

3360

420

... More
Earthing works including construction of earth pits and associated brick messonary work, laying of flats and installation of earth rod etc.:- Preparation of earthing pits (1.5x1.5x3.0 Mtrs.) (as per drawing)

1

10800

10800

... More
Earthing works including construction of earth pits and associated brick messonary work, laying of flats and installation of earth rod etc.:- MS Flat 65x8 mm

60

4680

78

... More
Earthing works including construction of earth pits and associated brick messonary work, laying of flats and installation of earth rod etc.:- MS Flat 50x8 mm

70

4200

60

... More
Stringing & Jumpering Twin zebra conductor (in Mtrs)

150

18900

126



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.