MP Power Transmission Company Limited Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

MP Power Transmission Company Limited - MPPTCL Tender

Services
Electrical and Electronics
Electrical Works
Eprocure
Opening Date23 Feb 2023
Closing Date15 May 2023
Tender Amount₹ 4,15,80,529 
Notes
Download

Costs

  • EMD

    ₹ 9,81,400
  • Document Cost

    ₹ 5,900
  • Tender Fee

    ₹ 1,534

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Black cotton Soil

7200

1656000

230

... More
Soft Rock

800

520000

650

... More
Hard Rock

250

465000

1860

... More
Excavation for Tower Foundation

-

-

-

... More
MC0 type towers

1

8400

8400

... More
MC30 type towers

1

9600

9600

... More
MC60 type towers

2

20600

10300

... More
MD0 type Tower

1

4400

4400

... More
MD15 type Tower

1

4800

4800

... More
MD30 type towers

1

5000

5000

... More
MD60 type towers

3

15600

5200

1

5900

5900

1

7700

7700

2

16400

8200

1

5900

5900

1

7700

7700

1

8200

8200

1

5800

5800

1

6600

6600

3

21900

7300

1

4200

4200

1

5000

5000

3

17700

5900

... More
Earthing of tower all the four legs

22

44880

2040

... More
Laying of RCC

90

6327000

70300

... More
Concreting

-

-

-

400

2960000

7400

420

3444000

8200

1100

9680000

8800

... More
Erection Tower for Modification work /Restoration work

260

2210000

8500

... More
Peripheral welding of nuts & bolts

3300

52800

16

... More
Fixing of tower accesssories like Danger board, Number plate, Phase plate and Anticlimbing Devices

24

95040

3960

... More
Stringing work on different type of towers with different conductors

-

-

-

... More
Stringing of 06 Nos. Twin ACSR Moose bundle conductor (03 Nos. Twin ACSR Moose bundle conductor per circuit i.e. 06 Nos. for 02 circuits) including jointing & hoisting of insulator strings, spacers, amour rods, dampers and other accessories and final jumpering of three phase of two circuits.

2

818000

409000

... More
Stringing of 12 Nos. ACSR Zebra conductor (4 circuit i.e. 12 Nos. for 04 circuits) including jointing & hoisting of insulator strings, spacers, amour rods, dampers and other accessories and final jumpering of three phase of two circuits.

3

960000

320000

... More
Stringing of 06 Nos. ACSR Zebra conductor (03 Nos. ACSR Zebra conductor per circuit i.e. 06 Nos. for 02 circuits) Under tension including jointing & hoisting of insulator strings, spacers, amour rods, dampers and other accessories and final jumpering of three phase of two circuits.

3

576000

192000

... More
Stringing of 03 Nos. ACSR Zebra conductor on (03 Nos. ACSR Zebra conductor per circuit i.e. 03 Nos. for 01 circuits) including jointing & hoisting of insulator strings, spacers, amour rods, dampers and other accessories and final jumpering of three phase of two circuits.

2

230000

115000

... More
Stringing of 06 Nos. ACSR Panther conductor (03 Nos. ACSR Panther conductor per circuit i.e. 06 Nos. for 02 circuits) including jointing & hoisting of insulator strings, spacers, amour rods, dampers and other accessories and final jumpering of three phase of two circuits.

4

676000

169000

... More
Stringing of 12 Nos. ACSR Panther conductor (4 circuit i.e. 12 Nos. for 04 circuits) including jointing & hoisting of insulator strings, spacers, amour rods, dampers and other accessories and final jumpering of three phase of two circuits.

3

855000

285000

... More
Stringing of 03 Nos. ACSR Panther conductor on (03 Nos. ACSR Panther conductor per circuit i.e. 03 Nos. for 01 circuits) including jointing & hoisting of insulator strings, spacers, amour rods, dampers and other accessories and final jumpering of three phase of two circuits.

4

396000

99000

... More
Stringing of earth wire (as per tower type) size 3.66mm, 95kg/sq.mm, final tension, fixing of all accessories (earth bond, suspension clamps etc.)

5

104000

20800

... More
Stringing of 1 OPGW 24 Fiber including jointing, placing of armour rod, dampers, final tension, fixing of all accessories and jumpering etc.

3

185400

61800

... More
Stringing of 1 OPGW 48 Fiber including jointing, placing of armour rod, dampers, final tension, fixing of all accessories and jumpering etc.

3

194700

64900

... More
Destringing & Restringing of ACSR Conductor by Declipping/Declamping work

-

-

-

... More
Destringing by Declipping/Declamping and release tension of 6 No. strung conductors, rest conductor temporarily on rollers without damages to conductors, towers etc. and then re string by tensioning clamping etc. for 400 kV DCDS line with ACSR Twin Moose conductor

3

984000

328000

... More
Destringing by Declipping/Declamping and release tension of strung conductor, rest conductor temporarily on rollers without damages to conductors, towers etc. and then re string by tensioning clamping etc. for 220 kV DCDS line with ACSR Zebra conductor

5

770000

154000

... More
Destringing by Declipping/Declamping and release tension of strung conductor, rest conductor temporarily on rollers without damages to conductors, towers etc. and then re string by tensioning clamping etc. for 220 kV DCSS line with ACSR Zebra conductor

2

182000

91000

... More
Destringing and Restringing by Declipping/Declamping and release tension of strung conductor, rest conductor temporarily on rollers without damages to conductors, towers etc. and then re string by tensioning clamping etc. for 132 kV DCDS line with ACSR Panther conductor

5

680000

136000

... More
Destringing by Declipping/Declamping and release tension of strung conductor, rest conductor temporarily on rollers without damages to conductors, towers etc. and then re string by tensioning clamping etc. for 132 kV DCSS line with ACSR Panther conductor

2

158000

79000

... More
Destringing of earth wire by Declipping/Declamping and release tension of strung earth wire, rest temporarily on rollers without damages to earth wire, towers etc. and then re string by tensioning clamping etc.

8

133600

16700

... More
Destringing of OPGW by Declipping/Declamping and release tension of strung earth wire, rest temporarily on rollers without damages to earth wire, towers etc. and then re string by tensioning clamping etc.

5

260000

52000

... More
Repair of Stub/chimney

-

-

-

... More
Repair of Stub/chimney, where 1 no. stub is to be repaired for 400/220/132kV towers

3

21345

7115

... More
Repair of Stub/chimney, where 2 no. stub is to be repaired for 400/220/132kV towers

3

39315

13105

... More
Repair of Stub/chimney, where 3 no. stub is to be repaired for 400/220/132kV towers

3

55476

18492

... More
Repair of Stub/chimney , where 4 no. stub is to be repaired for 400/220/132kV towers

3

72573

24191

... More
Dismantling of conductors of lines (Declipping/declamping & release of tension of strung conductor, rest conductor on rollers without damage to conductors, towers etc. and then laydown on ground safely without damages to towers and any other structures in the route, removal of insulator disc, hardwares & accessories from towers and bundling of conductors, packing of insulators & hardwares etc.)

-

-

-

... More
400kV DCDS line with Twin ACSR Moose conductor (excluding OPGW & earthwire)

2

736000

368000

... More
220 kV DCSS line with ACSR Zebra conductor (excluding OPGW & earthwire)

3

312000

104000

... More
220 kV DCDS line with ACSR Zebra conductor (excluding OPGW & earthwire)

3

516000

172000

... More
132 kV DCSS line with ACSR Panther conductor (excluding OPGW & earthwire)

3

267000

89000

... More
132 kV DCDS line with ACSR Panther conductor (excluding OPGW & earthwire)

3

459000

153000

... More
Earthwire

7

133000

19000

... More
OPGW (48/24 fibres)

3

174000

58000

... More
Dismantling of different types of tower in Good Condition

50

570000

11400

... More
Dismantling of different types of tower in Scrap Condition

100

600000

6000

... More
Collection of all dismantled materials like Towers, Conductor, Earth Wire H/W, Disc etc. Stacking at site and loading on Co.' truck and transportation and then unloading at co.'s Stores premises/ Trans. Stores. For 200KM

200

1440000

7200



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.