Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

MP Power Transmission Company Limited - MPPTCL Tender

Works
Eprocure
Opening Date27 Aug 2021
Closing Date9 Dec 2021
Tender AmountRefer Documents 
Notes
Download

Costs

  • EMD

    ₹ 68,32,000
  • Document Cost

    ₹ 22,400
  • Tender Fee

    ₹ 1,180

Summary

Design Supply Of All Material And Complete Const. Of 1no. 132/33kv Indoor Gis S/s At Phool Bag ( Gwalior)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Stringing of overhead shield wire with 7/3.66 mm standard galvanized steel complete with fixing of strain clamps at the structures.

200

-

-

... More
Suspension/T Clamps & Power/Terminal Connectors [not covered in respective equipments/ switchgear] etc. suitable for Single ASCR Panther [ for incterconnection from Line gantry, CVT, LA, Line Trap up to isolator incoming end] [Specify the Break Up with Quantity and Unit Prices for various items considered for this component of Price Scehdule]

1

-

-

... More
Add: Any other item bidder may require to complete the Switchyard Erection & Support Installations as per specification requirements

1

-

-

... More
Installation of transformers

-

-

-

... More
50MVA 132/33KV Transformer (with Oil and associated equipments) Complete assembly and erection of power transformer with connections etc including installation of marshalling boxes, control cabinets, air sealing radiators, cooling fans, all accessories etc for transformer including their preliminary checks. Unloading /handling of transformer accessories, handling and filling of transformer oil along with associated equipments.

2

-

-

... More
STATION TRANSFORMERShifting of 33/0.4 KV Station transformer up to Xmer Foundation and placing on it & connection to bushing & earth connection along-with installation of associated Isolator, DO set, LA & LTDB and associated work etc.

1

-

-

... More
132 kV Indoor GIS Switchgear Equipments

-

-

-

... More
145kV, 1250A, SF6 gas insulated Transformer bay module each comprising of SF6 gas insulated circuit breaker, current transformer , bus-bar disconnectors with common earthing switch, line disconnector with safety earthing switch, Lightening arrestor, SF6 gas monitoring system for complete bay, local control cubicle, Other accessories/items if any to complete transformer bay module alongwith XLPE Cable and terminations as indicated in the SLD/ Layout of substation and as per technical specifications.

2

-

-

... More
145kV, 1250A, SF6 gas insulated Feeder bay module each comprising of SF6 gas insulated circuit breaker, current transformer , bus-bar disconnectors with common earthing switch, line disconnector with saftey grounding switch, high speed fault making grounding switch, Lightening arrestor, SF6 gas monitoring system for complete bay, local control cubicle, Other accessories/items if any to complete feeder bay module alongwith XLPE Cable and terminations as indicated in the SLD/ Layout of substation and as per technical specifications.

2

-

-

... More
145kV, 1250A, SF6 gas insulated As a Spare module used as Transformer / Feeder Bay module each comprising of SF6 gas insulated circuit breaker, current transformer , bus-bar disconnectors with common earthing switch, line disconnector with safety earthing switch, Lightening arrestor,SF6 gas monitoring system for complete bay, local control cubicle,

1

-

-

... More
145kV, 2500A, SF6 gas insulated Bus Coupler Bay Module comprising of SF6 gas insulated circuit breaker, current transformer, disconnectors with safety earthing switches, Local control cubicle, SF6 gas monitoring system for complete bay etc. as indicated in the SLD/ Layout of substation and as per technical specifications.

1

-

-

... More
Double Bus Arrangement, 145kV, 3 Phase, SF6 gas insulated metal enclosed 2500A bus bars running along the length of the switchgear to interconnect each of circuit breaker bay module. Each bus bar set shall be complete with voltage transformer complete disconnector with safety earthing switch, local control cubicle (if required), SF6 gas monitoring system etc. for the complete bus as indicated in the SLD/ Layout of substation and as per technical specifications.

1

-

-

... More
Suitable Capcity EOT Crane for GIS Hall/ Building

1

-

-

... More
Ventilation system for GIS Hall/ Building (as per technical specification)

1

-

-

... More
Add: Any other item bidder may require to complete the 132 kV Indoor GIS Switchgear Equipments as per specification requirements

1

-

-

... More
36 kV Metal Clad GIS Indoor Switchboard(For indoor installation of modular design alongwith BCU based Control & Protection system.)

-

-

-

... More
Metal clad Double Bus Indoor GIS Switchboard Including Incomer Transformer Feeder Bays alongwith all associated accessories CTs,LAs. Control Cubicle and Complete with the Control & Protection schemes [ 36 kV, 2500A, 31.5 kA Class]

2

-

-

... More
Metal clad Double Bus Indoor GIS Switchboard Including 8 Nos. Outgoing Feeder bays alongwith all associated accessories CTs,LAs,Control Cubicle and Complete with the Control & Protection schemes [ 36 kV,1250A, 31.5 kA Class]

8

-

-

... More
Metal clad Double Bus Indoor GIS Switchboard Including 1 Nos. 1x12MVAR Capacitor bank bayalongwith all associated accessories CTs LAs.Control Cubicle and Complete with the Control & Protection schemes [ 36 kV, 2000A, 31.5 kA Class]

1

-

-

... More
Metal clad Double Bus Indoor GIS Switchboard Including 1 No. bus-Coupler bay CTs. Control Cubicle and Complete with the Control & Protection schemes [ 36 kV, 2500A, 31.5 kA Class]

1

-

-

... More
Metal clad Double Bus Indoor GIS Switchboard Including 1 No. Station Transformer bayalongwith all associated accessories CTs. Control Cubicle and Complete with the Control & Protection schemes [ 36 kV, 1250A, 31.5 kA Class]

1

-

-

... More
Metal clad Double Bus Indoor GIS Switchboard Including 2 Nos. PTs (one for each Bus) associated accessories Control Cubicle and Complete with the Control

1

-

-

... More
Installation of self supporting Composite type Polymeric Premolded Type End Termination for power cable of feeder bay complete in all respect with required fabrication on lattice support structure which also includes required lattice galvanized cable support structure, civil work, suitable clamp and connectors etc. complete in all respect with providing maintenance free earthing pit and GI earthing strip of each phase and required earthing

8

-

-

... More
Installation of self supporting Composite type Polymeric Premolded Type End Termination for power cable of transformer bay complete in all respect with required fabrication on lattice support structure which also includes required lattice galvanized cable support structure, civil work, suitable clamp and connectors etc. complete in all respect with providing maintenance free earthing pit and GI earthing strip of each phase and required earthing

8

-

-

... More
Installation of Three phase earth Link Box with SVL for each circuit with providing maintainance free earthing pit and GI earthing strip including required fabrication of structure, civil work if any

4

-

-

... More
Installation of Three phase earth Link Box without SVL for each circuit with providing maintainance free earthing pit and GI earthing strip including required fabrication of structure, civil work if any.

4

-

-

... More
Cable Termination/ Plug for terminating in 145kV, 1250A, SF6 gas insulated Feeder bay module 2 Nos. (Normally cable sizes is 1x800 Sq. mm per phase (3 nos cable for each feeder +1No.spare, exact size shall be decided during detailed engineering)

8

-

-

... More
Cable Termination/ Plug for terminating in 145kV, 1250A, SF6 gas insulated Transformer bay module 2 Nos. (Normally cable sizes is 1x800 Sq. mm per phase (3 nos cable for each transformer+1No spare, exact size shall be decided during detailed engineering)

8

-

-

... More
Cable Termination/ Plug for terminating in Metal clad switchgear panels for 2 Nos. (50 MVA Transformer) panels (Normally cable sizes is 2x630 Sq. mm per phase (6 nos cable for each transformer exact size shall be decided during detailed engineering)

1

-

-

... More
Cable Termination/ Plug for terminating in Metal clad switchgear panels for 8+1 Nos. (Outgoing Feeders+Cap Bank) panels (Normally cable sizes is 400 Sq. mm exact size shall be decided during detailed engineering)

1

-

-

... More
Cable Termination/ Plug for terminating in Metal clad switchgear panels for 1 Nos. (Station Transformer) panel (Normally cable sizes is 35 Sq. mm exact size shall be decided during detailed engineering)

1

-

-

... More
Add: Any other item bidder may require to complete the 36 kV Metal Clad GIS indoor Switchboard as per specification requirements

1

-

-

... More
132 KV & 33 kV XLPE Cables & Accessories

-

-

-

... More
1C,800 Sq. mm, Al., 132 kV XLPE Armoured Cable laying alongwith accosciated accessories and required material as per laying method adopted etc. (This include 24 lengths of cable with suitable

1000

-

-

... More
Under ground laying / installation of 08No. 76/132 KV (E), Single Core 800 Sq. mm XLPE insulated Power Cable (@ 03No. per Ckt. plus 01No. Spare) in Trefoil formation alongwith 02Nos. earth continuity cable (@ 1No. per circuit) and 02No. FOAC cable (@ 1No. per circuit) within HDPE pipe (One pipe per FOAC cable) and installation with hardware (like ties/clips/cleats, conduits, HDPE ducts, supports, fittings, accessories etc), phase identification tag, pre warning tape, route marker, HDPE pipe etc.), testing, installation etc. and associated civil works:-

-

-

-

... More
With open excavated trench (about of size 0.85M wide & 2.25M deep per circuit) in any type of soil, casting RCC side walls of size 0.6Mx0.05M, filling 0.25M sand before and upto 0.6M after laying cables, laying precasted RCC slab of size 0.6Mx0.05M over sand, back filling rest trench with natural soil and compaction (inclusive of all requisite materials (like sand, pre cast slabs, trefoil clamps mounted at min. 3Mtr. spacing)

60

-

-

... More
Laying/dressing/erection/connection of 8No. 76/132 KV (E), Single Core 800 Sq. mm XLPE insulated Power Cable (@ 3No. per Ckt. plus 1No. spare) in Trefoil formation, 2Nos. earth continuity cable (@ 1No. per circuit) and 2No. FOAC cable (@ 1No. per circuit) inclusive of all requisite material (like clamps, phase identification tag, construction of maintenance free earth pits seperately for each Ligthening Arrestors, supply & erection of G.I. earthing strip per phase, chamber, earthing connections, jumpering of conductors of overhead portion of the line etc.on tower structure including erection of Surge Arrester & FOAC cable in HDPE pipe & termination of fibers and required fabrication work if required for mounting.

2

-

-

... More
3 C, 35 Sq. mm. Al., 33 kV XLPE Cable with Suitable Outdoor & Indoor Terminations [3+3]for connecting the HV side of Substation Transformer to O/G of 36 kV Metal Clad GIS Switchgear

50

-

-

... More
1C, 630 Sq. mm, Al., 33 kV XLPE Armoured Cable alongwith accosciated accessories and required material as per laying method adopted etc. (This include 12 lengths of cable with suitable Outdoor & Indoor [12+12] end Terminations)

650

-

-

... More
3 C, 400 Sq. mm. Al., 33 kV XLPE Cable with Suitable Outdoor & Indoor Terminations [3+3]for connecting Outgoing feeder & Cap Bank to O/G of 36 kV Metal Clad GIS Switchgear (9+4spare lengths of cable with suitable Outdoor & Indoor end Terminations)

1000

-

-

... More
33 kV XLPE Cable Termination support structure for Connecting to 33 kV Side of 132/33 kV Transformer including 33 kV Class LAs (3 Nos.), Supporting PI String (3 Nos.), nut bolts, fixing accessories etc. as per drawing appended in Section-I

2

-

-

... More
Add: Any other item bidder may require to complete the 33 kV XLPE Cable system as per specification requirements

1

-

-

... More
C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II)

-

-

-

... More
132 kV C&R Panel For feederType SAS-FCRA

2

-

-

... More
132 kV C&R Panel For Bus Coupler Type SAS-BCRA

1

-

-

... More
132 kV C&R Panel For Transformer Type SAS-TCRA

2

-

-

... More
132 kV C&R Panel for Bus Bar Type SAS-BBRA

1

-

-

... More
Substation SAS Netorking Panel SAS-NW

1

-

-

... More
Station HMI [Industrial grade Computer with 23"LED monitor as per specification requirements] With inbuilt storage capacity for Minimum 3Years Substation Data

1

-

-

... More
Station HMI (Hot Standby)[Industrial grade Computer with 23"LED monitor as per specification requirements] With inbuilt storage capacity for Minimum 3Years Substation Data

1

-

-

... More
HMI View Node[Industrial grad Computer with 23"LED monitor as per specification requirements]With inbuilt storage capacity for Minimum 3Years Substation Data

1

-

-

... More
DR Work Station[Industrial grade Computer with 23"LED monitor as per specification requirements] With inbuilt storage capacity for Minimum 3Years Substation Data

1

-

-

... More
70'' Wall Mounted LED Display in Control Room

1

-

-

... More
A3 Size Color Laser Printer

1

-

-

... More
Mono Crome Laser Printer

1

-

-

... More
One Remote Workstation with HMI[Industrial grade Computer with 23"LED monitor as per specification requirements] With inbuilt storage capacity for Minimum 3Years Substation Data & Laser Printer (A4 Size) for RCC

1

-

-

... More
Hardware Gateways (for data transmission to SCADA C/R, SLDC & SUB SLDC)Multy Protocol,multy control centre support with Minimum Four (4) control centre connectivity

1

-

-

... More
Modems (both sending and Receiving End) for communication to SCADA C/R &SLDC & Sub SLDC [Specify the Break Up with Quantity and Unit Prices for various items considered for this component of Price Scehdule]

1

-

-

... More
Software: Application as well as System Software as per specification requirements for various hardware elements for meeting of functional requirement of the specification.[Specify the Break Up with Quantity and Unit Prices for various items considered for this component of Price Scehdule]

1

-

-

... More
Substation LAN Commnication Infrastructure

-

-

-

... More
Ethernet Switches:

-

-

-

... More
132 kV Side C&R and Network Panels:12 Nos.{6 Port (4 Nos. 10/100 BaseFX + 2 No. 10/100/1000 Base FX)}, 2 Nos. {24 Port 10/100 Mbps + 2 port 10/100/1000 Base FX}]

1

-

-

... More
33 kV Side C&R Panels: 2 Nos.{16 Port (4 Nos. 10/100 BaseFX + 2 No. 10/100/1000 Base FX)}

1

-

-

... More
Other Items : Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the substation LAN as per specification requirements. [Specify the Break Up with Quantity and Unit Prices for various items considered for this compo

1

-

-

... More
Inverter (3 kVA Capacity) to be operatable on 230VAC and 220 VDC as per availability of supply (Normally on AC)

1

-

-

... More
Inverter (1 kVA Capacity) to be operatable on 230VAC and 220 VDC as per availability of supply (Normally on AC)

1

-

-

... More
Add: Any other item bidder may require to complete the C&R Panels and SAS system as per specification requirements

1

-

-

... More
Lightening (Surge) Arrestors

-

-

-

... More
132kV class of 120kv rating LAs with grading ring discharge counter with milli ammeter including inverted LA of line

12

-

-

... More
33kV class of 30kV/36kV rating LAs

36

-

-

... More
Add: Any other item bidder may require to complete the Surge Arrester installation as per specification requirements

1

-

-

... More
Solid core Insulators (BPI)

-

-

-

... More
145 kV Class Solid core (Post) Insulator (if required)

6

-

-

... More
33 kV class Solid core (Post) Insulator

18

-

-

... More
33 kV Spacial P I set With Insulator for capacitor bank

1

-

-

... More
132 kV Disc Insulator String Suspension type alongwith suitable hardware

12

-

-

... More
Isolators

-

-

-

... More
Horizontal double break (HDB)motor operated 33kV isolator complete with all fittings, accessories, terminal connectors and all other items (as specified in technical specification for 1250A/800A HDB isolator with single earth switch)

9

-

-

... More
Horizontal double break (HDB)motor operated 33kV isolator complete with all fittings, accessories, terminal connectors and all other items (as specified in technical specification for 1250/800A HDB isolator without earth switch)

4

-

-

... More
Add: Any other item bidder may require to complete the Isolator Installation as per specification requirements

1

-

-

... More
Batteries & Battery Charger

-

-

-

... More
Batteries (Sizing shall be as per requirement of technical specification)

-

-

-

... More
220 V/300AH VRLA

2

-

-

... More
48 V/300AH VRLA

1

-

-

... More
Battery Charger System

-

-

-

... More
220 V Float cum Boost

2

-

-

... More
48 V Float Cum Boost

2

-

-

... More
Add: Any other item bidder may require to complete the Battery & Battery Charger as per specification requirements

1

-

-

... More
Lighting System

-

-

-

... More
Lighting fixtures (1X 400 W) for illumination of outdoor switchyard including the cost of sodium vapour lamps with all accessories and required cables, complete in all respects.

6

-

-

... More
Lighting fixtures (2X 400 W) for illumination of outdoor switchyard including the cost of sodium vapour lamps with all accessories and required cables, complete in all respects.

6

-

-

... More
1 x 11w LED lamps emergency light with Battery operated portable type with builtin battery and battery charger suitable for 6 hours operation.

1

-

-

... More
Outdoor Lighting poles with Lamps & Lighting Fixtures etc. complete

6

-

-

... More
GLS lamps of 100 w for operation on 220 V DC for Emergency lighting

3

-

-

... More
Lighting & Electrical Fixtures with Lamps, indoor/ outdoor receptles, G.I. Conduit, Junction Boxes, pull out boxes, wiring, Switchboard, Switches etc. for control room building and GIS Hall [not covered under the civil works][Specify the Break Up with Quantity and Unit Prices for various items considered for this component of Price Scehdule]

1

-

-

... More
Lightning Cum Lighting Masts. Approximate Unit Weight 2.68MT for each Mast

2

-

-

... More
Add: Any other item bidder may require to complete the Lighting System as per specification requirements

1

-

-

... More
Fire Fighting System

-

-

-

... More
Nitrogen Injection Fire Protection System for Power Transformer complete in all respects.

2

-

-

... More
Fire Fighting equipment with necessary mounting standsDCP Type. :

-

-

-

... More
DCP Type

-

-

-

... More
i) 5 Kg.

4

-

-

... More
ii) 10 Kg. Trolly Mounted

1

-

-

... More
iii)75Kg, Trolly Mounted

2

-

-

... More
Carbon di oxide type

-

-

-

... More
6 Liters.

2

-

-

... More
22.5 Liters.

4

-

-

... More
Foam Type

-

-

-

... More
9 Liters

1

-

-

... More
50Ltr, Trolley Mounted ( Cylinder Type)

4

-

-

... More
Sand type

-

-

-

... More
Set Of Fire Buckets Comprising 6 Nos Buckets, Capacity-9Kg , Each with Stand ( Set )

2

-

-

... More
Add: Any other item bidder may require to complete the fire figting system as per specification requirements

1

-

-

... More
Air Conditioning System

-

-

-

... More
High Wall Split AC units of 2 TR Capacity complete with Indoor, Outdoor Units and required accessories, Stablizers etc.

14

-

-

... More
Add: Any other item bidder may require to complete the Air Conditioning system as per specification requirements

1

-

-

... More
LT Switchgear

-

-

-

... More
LT AC Main Panel

1

-

-

... More
LT AC Distribution Board

1

-

-

... More
Main Lighting Distribution Board

1

-

-

... More
Emergency Lighting Distribution Board

1

-

-

... More
DG Incoming Board

1

-

-

... More
220V DCDB

2

-

-

... More
48V DCDB with Switching Cubicle

1

-

-

... More
Add: Any other item bidder may require to complete the LT Switchgear Installation as per specification requirements

1

-

-

... More
Earthing System

-

-

-

... More
Installation & testing of the following including jointing, equipment termination, fixing & clamping with accessories & hardware required such as saddle, clamps, cleats, plugs, screws, nuts, bolts, washers and welding, brazing etc.Earth electrodes installation directly driven/drilled (40 to 50 mm dia) into earth including excavation (irrespective of type of soil encountered) backfilling with bentonite soil (to be arranged by contractor) welding to earth conductor etc. Providing of steel risers and making earth mat (duly buried at a depth as per design approved) including backfilling with black cotton soil (to be arranged by the contractor) welding etc. and bolting of risers to the structure at desired place. Eathing of GIS Indoor equipments of 145/36kV Class by cupper flat Considering flat size asper design approved

-

-

-

... More
40 mm Dia MS Rod

1000

-

-

... More
3m, 20 mm Dia MS Rod Electrode

6

-

-

... More
3m, 40 mm Dia MS Rod Electrode

19

-

-

... More
3m, 42 mm Dia Safe Earthing Electrodes

15

-

-

... More
3m, 60 mm Dia Safe Earthing Electrodes

6

-

-

... More
50X12 mm GS Flat

700

-

-

... More
50X6 mm GS Flat

1400

-

-

... More
50 X 6 mm MS Flat

1000

-

-

... More
25 X 3 mm GS Flat

500

-

-

... More
Preparation of earthing pits (1.5X1.5.X3 Mtrs.) as per drawing attached with bid document, which includes excavation (Irrespective of the soil encountered) embedding of 4 No. GI Pipes of size 40 mm dia, 3 Mtrs. Long, back filling with B.C. soil (to be arranged by the contractor) free from boulders and harmful mixture. These GI pipes are to be welded with MS flats by making mesh frame and cutting of pipes as also making holes in the pipe for water seepage. The earth pit is to be connected with earth mesh of MS flat.

14

-

-

... More
Add: Any other item bidder may require to complete the Earthing System as per specification requirements

1

-

-

... More
1.1kV Grade PVC insulated Al. conductor power cables and copper conductor armoured control cables [Excluding the wiring required for electrical & Lighting fittings/fixtures installation in control room building]

-

-

-

... More
Power Cable(PVC)

-

-

-

... More
3.5Cx150 sq.mm

100

-

-

... More
3.5Cx70 sq.mm

50

-

-

... More
3.5Cx35 sq.mm

500

-

-

... More
4Cx16 sq.mm

1000

-

-

... More
4Cx6 sq.mm

2000

-

-

... More
2Cx6 sq.mm

1000

-

-

... More
1Cx6 sq. mm

50

-

-

... More
Laying of Control Cable (PVC)(armoured/unarmoured) on racks/cable trays/ angle support overhead racks conduits including dressing of cables with accessories for copper conductor & armoured control cables. Cable terminations including fixing of cable glands, lugs etc. for each type of control/ power cables, including terminations at both ends. I.R. value between cores and I.R. value with respect to its armouring is to be verified. The continuity of all cores is also to be verified. Both work to be done before connecting cable to the terminal block. Making suitable hole in bottom/side plate of C&R panel, AC/DC Board, Marshaling box for fixing cable glands in addition to cable gland holes already provided. The hole should be free from burrs. Fixing all cables in respective cable glands and re-fixing gland plate to its original place. All cable identification plate is to be provided on both ends of each cable. Stripping of outer insulation cover, armoring etc. of cable, fixing ferrules on each core at both ends. Stripping all cores to suitable length, making eye, crimping terminal lugs (as the case may be) and fixing it to terminal block as per drawing followed by proper bending/ dressing of all cores.

-

-

-

... More
2Core 2.5 Sq.mm armoured

2000

-

-

... More
4Core 2.5 Sq.mm armoured

5000

-

-

... More
8Core 2.5 Sq.mm armoured

2000

-

-

... More
12 Core 2.5 Sq.mm armoured

1500

-

-

... More
19 Core 2.5 Sq.mm armoured

1000

-

-

... More
Conduits, Cable Trays, Cable Tags, Cable Racks & Supports, Cable Glands, Cable Lugs, Gland Plates, Junction Boxes [Specify the Break Up with Quantity and Unit Prices for various items considered for this component of Price Scehdule][Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room building]

1

-

-

... More
Add: Any other item bidder may require to complete the Power & Control Cables as per specification requirements

1

-

-

... More
DIESEL GENERATOR SET

-

-

-

... More
DG Set along with enclosure and control panel (25 kVA)

1

-

-

... More
Add: Any other item bidder may require to complete the 25 kVA DG Set as per specification requirements

1

-

-

... More
GST @18% on Schedule A4

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.