MP Power Transmission Company Limited Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
MP Power Transmission Company Limited - MPPTCL Tender
Civil And Construction
Eprocure
Opening Date17 Oct 2022
Closing DateCancelled
Tender Amount₹ 4,88,450
Costs
EMD
₹ 9,769Document Cost
₹ 590Tender Fee
₹ 295
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_MPPTC_227958_1Bid Award Id
ViewTender No
91/1153Tender Authority
MP Power Transmission Company Limited ViewPurchaser Address
-Website
http://http://www.mptransco.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(SOR No. 5.16.1) Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . Mild steel and Medium Tensile steel bars.(Note:-1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge.2. No extra payment shall be done for overlaps and/or couplers.3.Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”)Mild steel and Medium Tensile steel bars.
70
-
60
(SOR No.5.16.6) Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786(Note:-1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge.2. No extra payment shall be done for overlaps and/or couplers.3.Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”)Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786
852
-
62.9
(SOR No.5.1.1)Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : M-20 Grade Concrete
28.04
-
5796
(SOR No. 5.9.1) Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for concrete upto plinth level
104.8
-
190.6
(SOR No. 5.9.2.1) Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. Uptoplinthlevel.
10
-
219
16 NSOR Labour only for fixing bolts of any length i/c weight of nuts & washers , etc. complete as per direction of Engineer in charge.
340
-
8
(SOR No. 2.27.1)Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete. With hard muram having CBR 12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm)
50
-
300
(SOR No. 10.2)Structural steel work using M.S. flats, angles, channels I-section, H-section etc. riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
354
-
69
(SOR No.4.1.1.3) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : With 20mm nominal size graded stone aggregate. M-15 – Grade concrete
16
-
4471
(SOR No. 6.5.2)Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete. Cement Mortar 1:6 (1 cement: 6 sand).
0.29
-
4155
(SOR No.13.2.2) 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement : 6 sand)
5.04
-
148
(SOR No.18.7.1) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,..having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This included jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer-in- Charge. External Work..15 mm nominal outer dia .Pipes.
15
-
122
(SOR No.18.7.2) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,..having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This included jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer-in- Charge. External Work..20 mm nominal outer dia .Pipes.
20
-
141
(SOR No.18.51.1) Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball..15 mm nominal bore, 105 mm long. Weighing not less than 138 gms.
15
-
234
(SOR No.18.31) Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931, 15 mm nominal bore.
3
-
458
(37 NSOR) Providing & Fixing in position LDPE Film of 150 micron (0.15 mm ) , ISI mark- 2508 (Grade 231) , including heat sealed joints at ends as per IS 9698 including cost of all material, labour, T&P, taxes, transportation etc. complete as directed by Engineer in charge
150
-
25
(SOR No.4.4.1) Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. M-15 (With 20mm nominal size graded stone aggregate)
2
-
4471
(8 NSOR) Supply,stacking and spreading of 40mm crusher broken metal black trap, basalt or granite uniformly in substation yard in desired thickness, free from dust and foreign matter,including transportation up to site, lead and lift, T&P, labour,royalty and taxes etc. complete as directed by Engineer-in-charge.
12
-
1003
(SOR No.5.9.3) Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform.
13
-
439.6
(SOR No.10.2) Structural steel work using M.S. flats, angles, channels I-section, H-section etc. riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
129
-
69
(SOR No.10.22.1) Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete.
146
-
86
(SOR No.10.1) Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
38
-
65
(SOR No.13.66.2) Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats.
20
-
53