MP Police Housing And Infrastructure Development Corporation Limited Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

MP Police Housing And Infrastructure Development Corporation Limited - MPPHIDCL Tender

Eprocure
Opening Date30 Jul 2020
Closing DateCancelled
Tender Amount₹ 1,75,26,000 
Notes
Download

Costs

  • EMD

    ₹ 1,75,260
  • Document Cost

    ₹ 12,500
  • Tender Fee

    ₹ 1,534

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(C) 13 M.long

53

-

-

... More
(d) 9 M.long

45

-

-

... More
Supplying and erection single length support for 33KV/11KV line complete with aligning and keeping it in truly vertical position, including digging pit of required size in all type of soil/rocks, filling with 1:3:6 cement concrete of0.50 mtr. dia. around the pole up to ground level includingmuffing of 0.45 mtr. dia. from ground level to 0.45 mtr. high as per specifications with 20 cm. thick base foundation in1:4:8 cement concrete as required, refilling the pit withboulder and soil as required, including painting of pole withbitumen paint below GL and two coats of red oxide and two coats of aluminium paint or synthetic enamel paintas directed etc as per specification complete The depth of burying of pole shall be 1/6th of the length of pole.H beam 175x85mm .......... weight

-

-

-

... More
(A) RS Joist Pole11 M.long

3

-

-

... More
STAY SET :Supplying and erection of GI/MS stay set complete with stay rod, anchor plate of size 300x300x5mm, thimble,stay rod, anchor plate of size 300x300x5mm, thimble,stay clamp, turn buckle, bow tightener etc. with stay wire, strain insulator, nut bolts as per specifications including excavation in all type of soil / rocks and foundation in cement concrete 1:3:6 of required size and other necessary materials complete as required as per specifications. GI Stay Rod 20mm dia 1.8 m long with 7/4mm stay wire for HT line

39

-

-

... More
STAY SET :Supplying and erection of GI/MS stay set complete with stay rod, anchor plate of size 300x300x5mm, thimble,stay rod, anchor plate of size 300x300x5mm, thimble,stay clamp, turn buckle, bow tightener etc. with stay wire, strain insulator, nut bolts as per specifications including excavation in all type of soil / rocks and foundation in cement concrete 1:3:6 of required size and other necessary materials complete as required as per specifications. GI Stay Rod 16 mm dia 1.8 m long with 7/4mm stay wire for HT line

42

-

-

... More
Supplying and Fixing 33 KV(10 KN) Polymer PIN INSULATOR of approved make on existing pole or bracket with other necessary materials complete as required. as per MPPKVVCL specification

52

-

-

... More
Supplying and Fixing 33 KV(45 KN ) DISC INSULATOR with 33KV strain (T&C) Hardware other necessary materials complete as required as per MPPKVVCL specification

150

-

-

... More
AAAC CONDUCTOR :Supplying and drawing ACSR/AAAC conductor of approved make with stringing making off complete with binding at existing insulator, jointing, jumpering, teeing off connecting etc. as required and clearing of obstacles (if any).

-

-

-

... More
(A) AAAC Conductor 55 sqmm aluminum or Equivalent (Rabbit) (0.05sqinch)

0.03

-

-

... More
(B) AAAC Conductor 100 sqmm aluminum or Equivalent (Dog) (0.10 sqinch)

10.08

-

-

... More
(C) AAAC Conductor 200 sqmm aluminum or Equivalent (Panther) (0.20 sqinch)

0.8

-

-

... More
33 KV ISOLATOR Polymer type :Supplying installation testing and commissioning of 400/600 Amp. triple pole outdoor type two stack and three Insulator padestals per phase, manual operated rotating type Isolator complete with fixed and moving contact of hard drawn electrolytic copper flat, 8 mm dia GI rod for fixed and moving arching horn, 32 mm dia GI pipe for operating handle, 19mm dia GI pipe for phase coupler,brass bush and trust bearing, isolator base channel, post insulator, padlock with key, earth/without earth switch and other required accessories etc. complete as required. 33 KV Isolator 400/600 Amp with earth switch (set of 3 Nos. for 3 phases)

6

-

-

... More
33 KV A.B.SWITCH-Supplying, Fixing, Testing and Commissioning of Gang operated air break off load disconnecting switch complete with self aligning type spring loaded fixed contact and knife type moving contact made of hard drawn electrolytic copper, GI phase coupling shaft, GI operating rod with handle, post insulator, contact gun, GI base channel, 7/8mm dia GI rod for arching horn etc. having verticle break and horizontal mounting type complete as required.

-

-

-

... More
(A) 33 KV 400 Amps AB Switch (Double stack & three insulator Padestals per phase)

1

-

-

... More
11 KV ISOLATOR Polymer type :Supplying installation testing and commissioning of 800 Amp. triple pole outdoor type two stack and three Insulator padestals per phase, manual operated rotating type Isolator complete with fixed and moving contact of hard drawn electrolytic copper flat, 8 mm dia GI rod for fixed and moving arching horn, 32 mm dia GI pipe for operating handle, 19mm dia GI pipe for phase coupler,brass bush and trust bearing, isolator base channel, post insulator, padlock with key, earth/without earth switch and other required accessories etc. complete as required. 11 KV Isolator 800 Amp with earth switch (set of 3 Nos. for 3 phases)

8

-

-

... More
11 KV A.B.SWITCH-Supplying, Fixing, Testing and Commissioning of Gang operated air break off load disconnecting switch complete with self aligning type spring loaded fixed contact and knife type moving contact made of hard drawn electrolytic copper, GI phase coupling shaft, GI operating rod with handle, post insulator, contact gun, GI base channel, 7/8mm dia GI rod for arching horn etc. having verticle break and horizontal mounting type complete as required.

-

-

-

... More
(A) 11 KV 200 Amps AB Switch (Single stack & two insulator Padestals per phase)

8

-

-

... More
Supplying, fixing, testing and commissioning of drop out fuse set complete with post type insulator, GI base channel, fuse barrel and elements, connector for incoming and outgoing jumpers etc. having verticle mounting type as required (Set of three numbers for three phases) 33 KV 400 Amps DO Fuse Set

1

-

-

... More
11 KV LIGHTNING ARRESTER Polymer type: Supplying, installation, testing and commissioning of station/ distribution class, thyrite magne valve, 0.10 W/KV watt loss lightning arrester with earthing neutral system. Arrester shall be rated at supply ( Set of three numbers for 3 phases) 11 KV Station Class LA 11 KV LA Polymer type Gapless/ matal Oxide 9 to 50 KV, 10 KA Sub Station Type

15

-

-

... More
33 KV LIGHTNING ARRESTER Polymer type: Supplying, installation, testing and commissioning of station/ distribution class, thyrite magne valve, 0.10 W/KV watt loss lightning arrester with earthing neutral system. Arrester shall be rated at supply ( Set of three numbers for 3 phases) 33 KV Station Class LA 33 KV LA Polymer type Gapless/ matal Oxide 9 to 50 KV, 10 KA Sub Station Type

9

-

-

... More
TRANSFORMERS : Supplying installing, connecting, testing and commissioning of 3 Phase, 50 Hz, 33/11 KV, Delta/Star connected ONAN cooling, step down, Copper wound, oil filled, Indoor/outdoor type, power transformer of accepted standard specification with accessories such as drain & filter valve, earthing terminals, lifting arrangements of suitable size, dehydrating breather with silica gel of suitable size, Conservator tank, air release devise, Rating & diagram plate, CI rollers, Radiators with shut off valve, Explosion vent with diaphragm, Off load tap changing switch, Buchholz relay, thermometer pocket with 6” dial type thermometer & OTI including Cable end boxes on HT & LT side bushings wherever required complete with first filling of oil with installation on existing foundation etc. complete as per specification. The no load and full load losses should not be more than as mentioned below.

-

-

-

... More
Power Transformer 33/11 KV, 3.15 MVA (OFTC .Loss 3+15KW)

1

-

-

... More
11 KV VCB Supplying, installation, testing and commissioning of triple pole outdoor type 11KV vaccum circuit breaker with outdoor control box, indoor control relay pannel for VCB and transformer protection and mounting structure for VCB and CTs complete as required. The indoor control relay panel shall consisting of Ammeter, Voltmeter Selector Switch, auxilliary relays for anti pumping device,trip and alarm of buchholz relay, oil and winding temperature circuit, electronic hooter, KWH meter, 230 V AC to 110 V DC power pack for closing, tripping and indication, triple pole IDMTL two O/C and one E/F delay with current setting range 50-200% and 10-50%, push button high speed trip rely etc. complete. The installation of VCB shall be carried out in accordance with IS:3072.The VCB shall be mounted on suitable size duly painted MS channel / angle iron structure with nut bolts and washer. The structure shall be fixed on existing cement concrete foundation. The complete work should be done as per IS specification. Having Ratio 200/100/5

3

-

-

... More
11 KV C&R Panel for Transfomer Protection (1 T)

1

-

-

... More
33 KV VACCUM CIRCUIT BREAKER : Supplying, installation, testing and commissioning of triple pole outdoor type 33KV vaccum circuit breaker with outdoor control box, indoor control relay pannel for VCB and transformer protection and mounting structure for VCB and CTs complete as required. The indoor control relay panel shall consisting of Ammeter, Voltmeter Selector Switch, auxilliary relays for anti pumping device,trip and alarm of buchholz relay, oil and winding temperature circuit, electronic hooter, KWH meter, 230 V AC to 110 V DC power pack for closing, tripping and indication, triple pole IDMTL two O/C and one E/F delay with current setting range 50-200% and 10-50%, push button high speed trip rely etc. complete. The installation of VCB shall be carried out in accordance with IS:3072.The VCB shall be mounted on suitable size duly painted MS channel / angle iron structure with nut bolts and washer. The structure shall be fixed on existing cement concrete foundation. The complete work should be done as per IS specification.

-

-

-

... More
(a) 33 KV VCB

3

-

-

... More
EARTH STATION :Providing and fixing earthing arrangement with Galvanized iron plate electrode, including packing of char coal powder and salt providing GI watering pipe 20mm dia of 2.4 m length from brick chamber upto electrode having 6 mm dia holes all around as required including making connections refilling the pit by black cotton soil as required as per specifications including excavation of pit of required size and 3 m depth in all type of soils/rocks, providing brick masonry chamber of size 450x450x300mm, CI frame, cover with lockingarrangement, wire mesh funnel etc. complete as per specifications. 600 x 600 x 6.3mm GI plate electrode

8

-

-

... More
EARTH STATION :Providing and fixing earthing arrangement with CI/Copper/Galvanized iron plate electrode, including packing of char coal powder and salt providing GI watering pipe 20mm dia of 2.4 m length from brick chamber upto electrode having 6 mm dia holes all around as required including making connections refilling the pit by black cotton soil as required as per specifications including excavation of pit of required size and 3 m depth in all type of soils/rocks, providing brick masonry chamber of size 450x450x300mm, CI frame, cover with lockingarrangement, wire mesh funnel etc. complete as per specifications. 600 x 600 x 3.15 mm Copper Plate electrode.

10

-

-

... More
EARTH STRIPS ;Supplying, laying and connecting of GI earth strip duly installed on wall/cable tray/beam/column with suitable size of clamps or in trench including excavation in all type of soil/rock upto 500mm depth and refilling the same, joints/connections of the strips shall be made by using nut, bolts, washers/by riveting/by soldering as required. Dissimilar metal joints shall have suitable bimetallic connectors etc. complete with fixing accessories and Corrosion protection of buried conductor with bituminous-coating. GI strip 25 x 5mm

500

-

-

... More
EARTH STRIPS ;Supplying, laying and connecting of copper earth strip duly installed on wall/cable tray/beam/column with suitable size of clamps or in trench including excavation in all type of soil/rock upto 500mm depth and refilling the same, joints/connections of the strips shall be made by using nut, bolts, washers/by riveting/by soldering as required. Dissimilar metal joints shall have suitable bimetallic connectors etc. complete with fixing accessories and Corrosion protection of buried conductor with bituminous-coating.Copper strip 50 x 5mm

130

-

-

... More
L.T.CABLES :Supplying, laying, testing and commissioning of insulated and PVC sheathed heavy duty power cable confirming to IS 7098/Part-I/88 with latest amendments, 1100 volts grade armoured cable of approved make with aluminium solid / stranded conductor. The cable shall be laid in air/in existing pipe/in existing cable trench/on existing cable tray with clamp as required as per specifications including providing of metal/PVC cable identification tags at both ends and every 10 Mtr.length of cable with inscriptions there on. Un

-

-

-

... More
(A) 2 Core 2.5 sqmm

0.1

-

-

... More
(B) 4 core 16 sqmm

0.1

-

-

... More
Providing PVC Heat shinkagesleeve colour coated as required as per specification . For 33 KV

120

-

-

... More
Supplying, Including cutting in required size and instaiation of 6mm thick MS Chequered plate of required size with hook and finising the same qas required.

400

-

-

... More
COPPER CONTROL CABLES :Supplying, laying connecting and testing of PVC / XLPE heavy duty control cable confirming to relevant IS specifications 1100 volts grade armoured of approved make with copper conductor in existing trench with clamp as required. The rate include for making cable end termination with suitable size brass cable gland and copper lugs etc. complete as required.

-

-

-

... More
(b) copper control cable 8 core 2.5sqmm PVC

0.8

-

-

... More
(c) copper control cable 4 core 2.5sqmm PVC

0.4

-

-

... More
(d) copper control cable 2 core 2.5sqmm PVC

0.2

-

-

... More
CLAMPS : Supplying and fixing following accessories of approved make with all required materials and labour as required suitable upto Dog conductor suitable upto Dog/ Panther conductor PG clamp

10

-

-

... More
CLAMPS : Supplying and fixing following accessories of approved make with all required materials and labour as required suitable upto Dog conductor suitable upto Dog/ Panthe conductor Tee clamp

48

-

-

... More
CLAMPS : Supplying and fixing following accessories of approved make with all required materials and labour as required suitable upto Dog conductor suitable upto Dog/ Panthe conductor Bimetallic clamp

48

-

-

... More
SHOCK TREATMENT CHART :Supplying and fixing in position best quality electric shock treatment chart written in Hindi and English duly framed in wooden frame and covered with glass as required and duly fixed in control room as directed.

2

-

-

... More
FIBRE GLASS ROD :Supplying of 20 feet long, telestone type fibre glass earth discharge rod suitable for 11/33 KV power supply complete with earthing chain, rubber grip etc. as required and as per ISS.

1

-

-

... More
CHAIN LINK FENCING :Providing and fixing of chain link fencing surrounding the existing 33/11KV Sub-Station on angle post of size 50x50x6mm, 3.50mtr. long and top end of post shall be bended 45 degree outside for barbed wire laying in 5 layers and to fabricate it in frame shape for fixing of chain link 2.5mtr. height of size 10 SWG GI wire and spacing of 50x50mm on frame duly welded with MS flat 20x3mm on all sides of frame or fixed with nut & bolt, including providing of gates of switchyard shall be made of 2" dia B class MS pipe and GI fensing shall be used to enclose the pipe frame work with angle iron of iron bracing and duly painted all the items by two coats of red oxide and two coats of synthetic enamel paint including digging of pit in all type of soil / rock as required. The depth of burying of angle post shall be 0.5 mtr. and filling with 1:3:6 cement concrete of 30 cm. dia. around the post as required. Measurements shall be done in RM of chain link used at Site

175

-

-

... More
Earth work in excavation by mechanical means (HydraulicExcavator) / manual means in all kind of soil, moorum,copra etc and for all types and sizes of foundations, drains, and trenches for pipes and cables with a free lead upto 50m and 1.5m lift, including disposed excavated stuff to be leveled and neatly dressed. Ordinary Rock

120

-

-

... More
Earth work in excavation by mechanical means (HydraulicExcavator) / manual means in all kind of soil, moorum,copra etc and for all types and sizes of foundations, drains, and trenches for pipes and cables with a free lead upto 50m and 1.5m lift, including disposed excavated stuff to be leveled and neatly dressed.Hard rock (Blasting prohibited)

80

-

-

... More
Supplying, stacking and spreading of nominal size metal 40 mm

120

-

-

... More
Providing and laying in foundation/plinth, mechanically mixed 1:2:4 (1 cement, 2 sand, 4 metal) cement concrete with 20 mm BT nominal size graded stone aggregates including ramming in layers, curing complete including cost of form work and cost of cement.

20

-

-

... More
Supply and fabrication of Iron work for reinforcement mild steel / tar steel, tested fixed in position complete i/c cutting, bending, all handling and binding with binding wire placing in position etc. complete

1000

-

-

... More
Fire Detection Equipment (A) FIRE EXTINGUISHER CARTRIDGE CO2 10 KGS Supplying and fixing of following type of ISI mark fire extinguisher with required clamps and other material complete as required.10 kg. BC CO2 type .(B) Supplying and installation of fire G.I. Buckets 3 Nos. duly painted with red oxide and synthetic enamel paint and filled with sand and stand complete as required as per specifications..As per enclosed drawing No.2

1

-

-

... More
Supplying and laying in position of ISI marked rubber mat rated for 1100 volts grade and 12.5 mm thick. . Size 1000mm x 2000mm.

3

-

-

... More
Suuplying , Fixing ,Testing & commisioning 33 KV Oil Immereed 3 phase 4 wire CTPT Units Having Ratio 400/200/5 with 0.5 class necessary material complete as required as per MPPKVVCL specification

2

-

-

... More
Suuplying , Fixing ,Testing & commisioning 33 KV/11 KV 3 phase CTPT Ratio 2.5/5 amp Out door Immersed type necessary material complete as required as per MPPKVVCLspecification

3

-

-

... More
Suuplying , Fixing ,Testing & commisioning 11 KV 5 PTs Oil Immersed necessary material complete as required as per MPPKVVCL specification

3

-

-

... More
Suuplying , Fixing ,Testing & commisioning HT Meter for subtation metering 3 phase 4 wire 3x63.5 volt necessary material complete as required as per MPPKVVCLspecification

5

-

-

... More
Suuplying , Fixing ,Testing & commisioning Meter Box Suitable for K-3000 MKS with TTB necessary material complete as required as per MPPKVVCL specification

5

-

-

... More
Suuplying , Fixing ,Testing & commisioning DC Distribution Board necessary material complete as required as per MPPKVVCL specification

1

-

-

... More
Suuplying , Fixing ,Testing & commisioning Ac Distribution Board with MCB necessary material complete as required as per MPPKVVCL specification

1

-

-

... More
11 KV C&R Panel for Transfomer Protection (2 F) as required as per MPPKVVCL specification.

1

-

-

... More
BATTERY AND BATTERY CHARGER : Lead Acid Battery Supplying, installation, testing and commissioning of 100AH capacity 30 volt (15 No cells each of 2.0 Volt) NICAD battery bank, and 30 volt 20A battery charger suitable of above battery bank with initial charging capacity capability in a duly painted MS enclosure complete with provision for keeping the 30 volt battery in the same enclosure complete as required as per specifications and other necessary materials etc.complete as required. 30 V-100 Ah With as required as per MPPKVVCL specification.

1

-

-

... More
1500 KVAR, 11 KV Capacitor Bank Complete with individual fuses, interconnection, mounting racks, external fuses, maounting arrangement bas insulator and accessories as required as per MPPKVVCL specification.Supplying, installation, testing and commissioning of low dielectric losses (0.07 watt/KVAR), 10,000 Amp. fault current handling capability, outdoor type 11 KV rated capacitor bank for power substation made of stainless steel tank with light grey finish, light grey wet process porcelain bushing, parallel grove terminal and connector, internal discharge resistor, stainless steel, name plate. The rate include of indoor type power factor improvement pannel complete with contactor, SFU, MCCB, APFC relay, push button, internal wiring etc. complete with single phasing AB switch 3 nos., 11 KV oil emerged CTPT etc. complete as per specifications.

1

-

-

... More
Supplying and erection of steel tubular pole swaged type as per IS:2713 1980 Complete with baseplate and top Canopy (with G.I. pipe bracket as required), supports complete with digging and keeping it in truly vertical position i/c digging pit of required size filling with 1:3:6 cement concrete of 0.60 meter dia. of required length around the pole i/c muffing of 0.45meter from ground level as per specification with 20cm.thick base foundation providing and busying 15mm.dia.G.I.pipe from bottom to 1.5meter above ground level on pole, refilling the pit i/c. painting of pole with bitumen paint in bottom and one coat of red oxide and two coat of aluminum paints etc. complete as per specification. The depth of foundation shall be1/6th of the length of pole.

-

-

-

... More
(A)     410 SP-29 - 9 meter length and 125 Kg Weight of Size 5000x139.7x4.85mm, 2000x114.3x4.5 mm 2000x88.9x3.25mm with base plate.

47

-

-

... More
Supplying and fixing of Angle/ channel/flat iron, V cross Arms reinforcement of RSJ jolt/ flat iron fittings for overhead lines and poles such as cross arms/ bracket/ clamps/ stiffness for poles etc. all required steel work including' cutting to size making proper shapes drilling scan welding etc. including nuts & bolts plan & spring wisher and other necessary material including one coat of red oxide and two coat of aluminum paint etc. as required. Chequre plate/ Tenstion plate atc.

7000

-

-

... More
Supplying and fixing Polymer type 11 K.V. pin insulator with G.I. pin of approved make on existing pole or bracket with necessary materials and hardware complete as required.

209

-

-

... More
Supplying and fixing polymer type 11 K.V. disc (strain) insulator of approved make on existing pole or bracket with necessary materials and hardware complete as required.

45

-

-

... More
Providing and fixing ear thing arrangement for H.T./L.T. poles with G.I. wire of 115 turn of 50mm dia. connection with bracket/ cross arm/ pole with 4mm dia. G.I. lead through 20 mm dia. G.!. Protection pipe of length from bottom of pole to 2 meter above ground level, packing of charcoal powder and salt as per specification including excavation of pit in all type of soil / rock etc. complete.

88

-

-

... More
DANGER CAUTION PLATES :Providing and fixing enamelled danger caution plate/board on existing electric poles or wherever required of size 250x200 mm, made of 1.6mm thick mild steel sheet and vitreous enamelled white, with latest, figures and the conventional skull and cross-bones in signal red colour (as per IS-5-1978 with latest amendment) on the front side.The rear side of the plate shall also be enamelled. The corner of the plate shall be rounded off with required material such as screws, wires clamps, nut bolts etc. complete 33 KV/11 KV

79

-

-

... More
Supplying and fixing 12x16 gauge barbed wire antidumping device (900 mm and3.5kg wire on pole) around the existing H.T. pole and sub station poles for safety measures as per IE rules including all staples and all other necessary materials complete as per mpseb specification.

139

-

-

... More
Supplying, installing, connecting, testing and commissioning of approved make distribution transformer 5 star rating of accepted standard specification oil filled, core type aluminum wound out door type 11/ 0.4: KV step down with drain and filler . Value with locking arrangement two ear thing terminals, lifting arrangements and first filling of oil, conventional unit, including installation on existing D.P. structure.

-

-

-

... More
(A) 100 KVA 11 / 0.433 KV (Conventional) 5 Star Rated.

1

-

-

... More
Providing and fixing outdoor type pole mounting weather, dust and vermin proof L.T. distribution box made of 14/16 gauge, M.S. sheet with clamping arrangements, lockable hinged door duly painted on all sides with red oxide antirust and corrosion treatment two coats of synthetic enamel paints of approved make and shade, consisting of following fittings. L.T. Distribution box suitable for 63/100/200.KVA.transformer (without TPN switches) with required Amp MCCB/Isolator on incoming side and PF HRC units on outgoing side.

-

-

-

... More
(A) For 100 KVA Transformer (300 A. Isolator of 6 SP of 60 A. & 6 no J type al hook.) Complete as required as per MP SEB latest Specification.

1

-

-

... More
Commissioning of D P structure over existing support with panting in an approved manner consisting of following :- (A) D. C. cross arm with clamp, nuts & bolts (100 x 50 mm only ) - 1 set (B)    11 KV D. O. fuse unit, lightings arrangement and AB swich mounting channel with nuts and bolts (75 x 40 mm channel) of require - 1 set (C) 11 KV Polymer AB swich as required - 1 set (D)    Transformer mounting cross arms / channels with clamps nuts and bolts (100 x 50 mm channel ) - 1 set (E) 11KV Polymer Do fuse unit ( set of 3 no.) - 1 set (F) Transformer clamping set (50x50x6 mm angle ) with nuts and bolts etc. complete -1 set (G) Transformer belting set (50x50x6 mm angle) with nuts and bolts etc. complete -1 set (H) 11 kv polymer lightning arrestor (9 kv gapless type ( 5 kA ) for DTR ) ( set of 3 No.) - 1 set (I) supplying , fixing, testing and connecting of complete Earting set of 7 No. as per MPMKVVC.Ltd. circular No DS CO M/EZ/ WS/1516/DT 17-03-2008 and approved dwring for transformer sub - station including all materials GI Strips, GI wires, Charcoal power salt excavation of pits in all types of soils/rocks etc. as required complete .( 1 set of 7 Nos.) -1 set (J) Distribution panel mounting channel and clamp with nuts & bolts etc. (75 x 40 mm channel ) 1 – set (K) Supplying , fixing, testing and Commissioning of DTR Meter LT. 3 phase 4 wire 3X240 volts I 3 A. LTCT operated 3 phase 4 wire 3x63, 5 volts , LB = 5 amps lmax 10 amp trivector meter glass of accuracy 0.5s DLMS complaint category a meter along with GSM ( GPRS compactable ) modems with box i/c all accessories and formalities as per MPMKVVCL as required. or 3P 4w - 5A LTCT class 5s DLMS compliant type c. rs - 232. Port box MRI LTCT 100/5A i/c meter box with TTB etc as requiredas (L) SF & T and HT tape for covering LT bushing i/c windings and blower hitting complete minimum 30 meter or as required.

-

-

-

... More
D.P. Structure Complete as above (A to L)

1

-

-

... More
Supplying ,laying ,testing, and commissioning of P V C insulated PVC heavy duty power cable confirming to lS 1554­1964 with upto date ammnandentment,1100 volt grade cable Of approved make in trench ,G I pipe Air (laying on pole) trench, i/c cost of excavation in any type of soil/rock etc. including connection through lugs by cramping method glands etc as required as per specification.

-

-

-

... More
(A) Supplying laying testing and commissioning.UnArmoured single core XLPE insulated aluminum conductor cable.

-

-

-

... More
(a)   70 sq mm.

0.08

-

-

... More
(b)   150 sq mm.

0.04

-

-

... More
(D) AB cable (2X25+1X16)sqmm 1100 Volts. with insulated messenger wire. With required by mpseb specification.

4.25

-

-

... More
Supplying and erection of G.I. guarding of required size on existing HT lines as required as per specifications. Carpet/Cradle type 8 SWG (4 mm. dia.)

1.6

-

-

... More
Supplying fixing testing and commissioning in propermannr street light timer switch with all required accessories complete with 110 Amps or req.amp switch Timer Panel completed

2

-

-

... More
Supplying & installation of suitable class G.I.(’B’ class) protective pipe including cutting making thred providing sockets bend, elbow, nuts & bolds of approved manner as required to complete the job fixed on wall, poll or laying in ground trench i/c excavation in all type of solid/rock in an approved to manner as required.

-

-

-

... More
(A)G.I. Pipe ‘B’ class 40 mm dia.

120

-

-

... More
(B) G.I. Pipe ‘B’ class 150 mm dia.

20

-

-

... More
(C) G.I. Pipe ‘B’ class 80 mm dia.

20

-

-

... More
Jointing slives Suitable for Al AAAC Conductor

19

-

-

... More
Supplying Fixing And Testing Junction Box Spring Loaded Complete As per Required by MPSEB Required.

-

-

-

... More
(A) THREE PHASE .

4

-

-

... More
Supplying and fixing street light with high power LED of 1 to 3 W each assembled on single MCPCB, system lumensoutput with efficacy90 lm/W. luminiare having color temp 6500K & 50000 burning hrs life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF 0.95 & surge protection 3KV. Housing made of pressure die cast aluminium with heat resistant flat glass / Lens type, IP65 protection. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer manadatory i/c 50mm.dia G.I. Pipe bracket upto 2 mtr. long in required angle/shape, connection lead, testing etc to complete the job. 2 Yrs Guarantee certificate from manufacturer.

-

-

-

... More
(A) 90 watt Stete Light Road In IR & (48+192) qtrs

107

-

-

... More
Supplying & Fixing of ISI Marked and approved make of Moulded Case Circuit Breaker (MCCB) suitable suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828 MCCB wiht Breaking Capacity 35 KA at 415 V (for the uses street light & pumps)

-

-

-

... More
Current Rating 200 Amps & Adjustable 80% -100% thermal

1

-

-

... More
MCCB wiht Breaking Capacity 35 KA at 415 V

-

-

-

... More
Current Rating 100 Amps & Adjustable 80% -100% thermal

1

-

-

... More
MS SIGN BOARD, BAY INDICATION BOARD & RYB PHASE INDICATION BOARD (AS PER TENDER DRAWING NO. MISC.-7 )As required As per MPPKVVCL specification

1

-

-

... More
YARD LEVELING AND METALLING (AS PER DRAWING NO. MISC.-10 ) As required As per MPPKVVCL specification

1

-

-

... More
MS SIGN BOARD, BAY INDICATION BOARD & RYB PHASE INDICATION BOARD (AS PER TENDER DRAWING NO. MISC.-7 )As required As per MPPKVVCL Specification

1

-

-

... More
NOTE - 1) The contractor is responsible for approval fo transformer/sub station/HT/LT lines/ Testing of LTCT. Meter, form competent authority of Electrical Inspector and energy station/commissioning of sub station HT/LT lines and necessary shut down form MPMKVVCO. No extra payment will be done for this jop. 2) All Material for use in External Electrification work of as per approved List attached. 3) Quantities/ items may increased/ decrease as per site conditions.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.