MP Laghu Udyog Nigam Limited Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
MP Laghu Udyog Nigam Limited - MPLUN Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date2 Mar 2019
Closing Date18 Mar 2019
Tender Amount₹ 2,40,04,126 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 2,41,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_MPLUN_22005_1Bid Award Id
ViewTender No
MPLUN/Const./E and C/Indore/ 2019/1416Tender Authority
MP Laghu Udyog Nigam Limited ViewPurchaser Address
-Website
http://https://mptenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
SOR page no. 25 item no. 4.12 - Crusher Run Macadam Sub Base/Base Course Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor grader, watering and compacting with a vibratory roller to clause 410 to form a layer of sub-base/Base in accordance to Table No. 400-14, 400-15 and as per clause of section 407 of specifications. For 53 mm maximum size
878.85
-
957
... More
SOR page no. 34 item no. 6.1 - Dry Lean Cement Concrete Sub- base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8- 10 tonnes vibratory roller, finishing and curing as per clause 601 of specification complete in all respect.
567
-
2199
... More
SOR page no. 37 item no. 6.3 -Cement Concrete Pavement Construction of un-reinforced, dowel jointed, plain cement concrete pavement M-40 grade concrete over a prepared sub base with cement , coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, onstruction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures as approved, curing compound, finishing to lines and grades as per drawing as per IRC 15 2011 and as per relevant clauses of section 602 of specifications complete but excluding cost of steel in dowel bar and tie rods etc.
1423.32
-
5153
... More
SOR page no. 25 item no. 4.13 - Construction of Shoulders with approved material/selected soil i/c excavation all lifts & leads i/c grading to required slope & camber of 4% and compacting using vibratory roller of 80 to 100 kN static weight to meet requirement as per relevant clause of 400. B) Hard Shoulders (CBR value 12)
1620
-
181
... More
Hume Pipe Culvert
-
-
-
... More
SOR page no. 58 item no. 12.1 - Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out,
construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. as per relevant clauses of section 300 & 2100 in
I. Ordinary soil
A. Mechanical Means
(i) up to 3 m depth
359.28
-
52
... More
SOR page no. 51 item no. 9.1 - PCC M-15 in Foundation Plain cement concrete M-15 mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. as per MORT&H Specification 409.
17.55
-
3409
... More
SOR page no. 51 item no. 9.2 - Laying Reinforced Cement Concrete Pipe NP4/prestrssed concrete pipe on first class bedding in single row. Providing and Laying Reinforced cement concrete pipe NP4/prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets.
40
-
5668
... More
SOR page no. 51 item no. 9.8 - Providing P.C.C. M-15 Nominal mix for hume pipe culverts in foundation and sub structure etc. as per drawing and as per relevant clauses of section 1500, 1700, 2100 and 2900.
106.05
-
4353
... More
R.C.C. Drain
-
-
-
... More
SOR page no. 20 item no. 3.9 - Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)as per relevant clauses of section 300 & 2100 in:
I. Ordinary soil
A. Manual Means
(i) up to 3 m depth
480
-
66
... More
SOR page no. 59 item no. 12.3 - Providing Plain cement concrete M-15 nominal mix in foundation as per relevant clauses of sections 1500, 1700 and 2100.
240
-
4299
... More
SOR page no. 59 item no. 12.8 - Provdiing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with . C RCC Grade M20
624
-
4919
... More
SOR page no. 62 item no. 12.31 - Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications and as per relevant clauses of section 1600.
40.56
-
49081
... More
External Electrification
-
-
-
... More
(I 42.2.2) Supply of support for overhead line RS joist /'H' Beam of I.S. standard including drilling of required hole etc. complete as required. R.S. Joist 175 x 85 - 19.3 kg/per metre
465
-
1275
... More
(I 42.2.6) H - Beam 152 x 152mm, Std weight 37.1 Kg / Mtr
650
-
2545
... More
(I 42.13) Erection of RS Joist pole / 'H' Beam / steel tubular / steel rail pole of length 7 metres but not exceeding 10 metres in cement concrete 1:3:6 (1 cement : 3 core sand: 6 graded stone aggregate 40mm nominal size) base, foundation, muffing including excavation and back refilling etc. as required.
50
-
3316
... More
(I 42.14) Erection of RS Joist pole / 'H' Beam / steel tubular / steel rail pole of length exceeding 10 metres but not exceeding 13 metres in cement concrete M-10 (1 cement:3 core sand: 6 graded stone aggregate 40mm nominal size) base, foundation, muffing including excavation and back refilling etc. as required.
50
-
4027
... More
(I 42.5.3) Supplying and drawing All Aluminum Alloy conductor (AAAC) of approved make confirming to IS 398-1979 Pt. IV, including binding at existing insulator, jointing, jumpering, tearing off, connecting etc. as required including clearing ofobstacles (if any) AAAC 0.075 sq inch (80 Sq.mm Al. EQ. ) - (Raccoon)
7.5
-
64688
... More
(I 42.8) Supplying and drawing guard wire/earth wire/bearer wire 13mm2 (4mm. Dia) G.I. including stringing, binding at existing insulators or brackets, jointing, jumpering, connecting & cradle etc. as required and clearing of obstacles (if any)
2.5
-
14690
... More
(I 42.11.3) Supplying and erection of guards for existing overhead lines as required including split insulator required as per specification: Ring type
450
-
16
... More
(I 42.20) Supplying and erection of stay set complete (Galvanized) 19mm. Dia x 1.8 metre long stay rod anchor plate of size 300 mm x 300 mm x7.5mm, thimble, stay clamps, turn buckle (19mm dia x 600mm),7/4.00mm dia G.I. Stay wire etc. in cement concrete M-10 (1 Cement : 3 Coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required.
25
-
3906
... More
(I 42.36) Supply, fabrication and erection of Angle/Chanel/Flat iron fitting for over head line & sub-station etc such as 'D' bracket, cross arms, top clamp, 'V' cross arms, Back/Support clamps or other similar work etc. including nut bolts of required size, making holes, fabrication, welding, cutting, etc. and painting with one coat of red oxide paint & two coat of aluminium paint as required as per specification.
3500
-
80
... More
(I 42.37) Labour charges for erection of Angle/Chanel/Flat iron fitting for over head line & sub-station etc such as 'D' bracket, cross arms, top clamp, 'V' cross arms, Back/Support clamps or other similar work etc. including nut bolts of required size, as required as per specification.
3500
-
7
... More
(I 42.46) Supplying and erection of 11kV (5 KN) Polymer pin insulator complete with long steel head G.I. pin, nut, washer etc. as required.
130
-
295
... More
(I 42.47) Supplying and erection of 11kV (45 KN) Polymer disc insulator for 11kV overhead lines with galvanized insulator fittings, ball and socket type, and complete with galvanized strain clamp, bolts, nuts washer etc. as required.
30
-
404
... More
(I 42.48) Supplying and erection of 33kV (10 KN) Polymer pin insulator complete with long steel head G.I. pin, nut, washer etc. as required
9
-
430
... More
(I 42.49) Supplying and erection of 33kV (45 KN) Polymer disc insulators for 33KV overhead lines with galvanized insulator fittings, ball and socket type, and complete with galvanized strain clamp, bolts, nuts, washers etc. as required.
6
-
661
... More
(I 42.50) Labour for erection of 11/33kV Polymer pin insulator complete with hardware as required.
139
-
91
... More
(I 42.51) Labour for erection of 11/33kV Polymer disc insulators for 11/33KV overhead lines complete with hardware as required.
36
-
146
... More
(I 42.52) Supplying and erection of single piece non linear resistor type lighting arrestor (Set of 3 Nos) for 3 wire, 11kV overhead lines/sub-station with rated voltage of 9kV (rms) with a nominal discharge current rating of 5 KA and complete with galvanized clamping arrangement, G.I. bolts, nuts, washer etc. as required.
2
-
3391
... More
(I 42.56.2) Supplying installing, testing & commissioning of outdoor H.T., AB switch assembly set gang operated with brass contact parts, including required GI pipe operating rod, handle & locking arrangement on On-Off position conforming to IS complete with required material and installing on existing DP structure to complete the job as required as per specification.(Set of 3 nos.) 11 kV, 400A.
2
-
6843
... More
(I 42.57.1) Supplying installing, testing & commissioning D.O. fuse assembly with brass part contact for 33 or 11/0.4 KV DP Structure set of 3 Nos. with fuse barrel i/c required fuse element & other materials as per specification on existing D.P. structure as required. 11kV
2
-
3275
... More
(I 42.61) Supply & fixing anti climbing device with 2 ply G.I. barbed wire 1 Kg. per pole complete as per specification.
50
-
126
... More
(I 42.62) Supply, laying and fixing of G.I. earth coil of 4mm dia G.I. wire having 120 turns of nearly 50mm dia. and 3 mt. long tail in existing pit duly earthed with pole etc complete as required as per specification.
125
-
220
... More
(I 42.63) Supplying and fixing 33/11/0.4 KV enamel coated danger board size 200x250mm with clamp on existing HT/LT structure / poles.
50
-
148
... More
(I 42.64.1.4) Supplying, installing, testing and commissioning of 11/0.4 K.V. 3 Phase 50 Cycle oil immersed, naturally cooled, out door type transformer connected delta on H.T. side and star on L.T. side, hand operated off load Tap changer switch above 100 kVA, oil conservator with drain valve, plug 63 KVA and above, dehydrating silica gel breather on eye level, rating and diagram plate, two earthing terminal, lifting lugs, oil level gauge, drain valve with plug, temperature not exceeding 50ºC on load, oil filling hole with plug, four unidirectional roller, arcing horns, explosion vent, terminal arrangement bushing on H.V. side and cable box on LV side, first filling of oil upto desired level and transformer installing on existing structure with all required materials arrangement as required as per IS specification. Marked ISI & 3 Star rating Aluminium wound 200 kVA Each
2
-
336138
... More
(I 42.85.2.7) Supplying & drawing / laying of PVC insulated XLPE Aerial bunch power cable conductor H2/H4 grade Aluminium Solid/stranded confirming to IS-14255- 1995, Alu. Alloy insulated messenger 1100 volts grade cable of approvedmake in Air with necessary material as per specification of required size as mentioned below – (ii) Single Core cable( Insulated neutral messenger) (g) 3x150 Sq.mm, 1x35(St.Light), 1x95( Insulated neutral messenger)
1300
-
891
... More
(I 42.86) Supplying & fixing of Aerial bunch cable accessories suspension clamps i/c required attachment for single core cable of approved make on pole with clamp, necessary material as per specification for required size.
70
-
343
... More
(I 42.87) Supplying & fixing of Aerial bunch cable accessories Tension clamps (Dead end) i/c required attachment for single core cable of approved make in air with clamp,necessary material as per specification for required size.
20
-
371
... More
(I 42.88.2) Supplying & fixing of waterproof Insulation Piercing connector for Aerial bunch cable i/c required attachment for single core cable of approved make in Air with necessary material as per specification of required size as mentioned below – Main: 50-150sq.mm, Tap: 6-50sq.mm
80
-
153
... More
(I 42.89.2.3) Supplying & fixing of Spring loaded bus bar screw less connector with enclosure of approved make including required clamps, nut, bolt, connection, testing as per specification to complete the job. Three Phase 3Ph, 1In+6Out
80
-
8334
... More
(I 42.7) Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu. /Copper solid/stranded conductor evently cramped with high/pressure tool and connected to switch gear/Bus/M.C.C.B./ M.C.B. etc. as required complete. (I 42.7.3)35 Sq.mm
80
-
5
... More
(I 42.7.6)95 Sq.mm.
80
-
16
... More
(I 42.7.8)150 Sq.mm.
240
-
30
... More
(I 37.3) Earthing with G.I. Earth plate 600mm X 600mm X 6mm thick including accessories and providing masonary encloser in cement mortor, cover plate having locking arrangement on the top and G.I. watering pipe 20mm dia 2.7 Metre long etc. (but without charcoal or coke and salt ) complete as required.
10
-
2951
... More
(I37.5.2) Add Extra for using salt and charcoal / coke for G.I. Plate or Copper plate earth electrode as required including excavation in hard rock and refilling the pit with black soil.
10
-
3353
... More
(I 37.18) Supplying and laying 50mm X 6mm G.I. strip at 0.5 metre below ground level / surface as strip earth electrode including jointing etc. as required.
100
-
95
... More
(I 34.4.2) Primer coat over new steel and other metallic surface with red oxide/ zinc chromide paint complete with supply of material labour etc. including preparation of surface.
1090
-
47
... More
(I 34.4.3) Final coat with aluminium paint, brushing complete including material and labour.
1090
-
59
... More
(I 31.29.4) Supplying and fixing street light with high power LED of 1 to 3 W each assembled on single MCPCB, system lumens output with efficacy90 lm/W. luminiare having color temp 6500K & 50000 burning hrs life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF 0.95 & surge protection 3KV. Housing made of pressure die cast aluminium with heat resistant flat glass / Lens type, IP65 protection. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer manadatory i/c 50mm.dia G.I. Pipe bracket upto 2 mtr. long in required angle/shape, connection lead, testing etc to complete the job. 2 Yrs Guarantee certificate from manufacturer.
7
-
23923