MP Housing And Infrastructure Development Board Tender

... More
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

MP Housing And Infrastructure Development Board - MPHIDB Tender

Works
Civil Works Water Works
Coronavirus COVID 19
Eprocure
Opening Date23 Nov 2019
Closing Date30 Nov 2019
Tender Amount₹ 22,78,000 
Notes
Download

Costs

  • EMD

    ₹ 50,000
  • Document Cost

    ₹ 5,900
  • Tender Fee

    ₹ 295

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SOR 2.8 Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (No extra lift is payable if work is done by mechanical means) All kinds of soil All kinds of soil. SOR : 2.26.1 Extra for every additional lift of 1.5 m or part thereof in excavation. (No extra lift is payable if work is done by mechanical means) All kinds of soil.

19.48

-

144.9

... More
SOR 4.1.2.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : With 40mm nominal size graded stone aggregate. : Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate (M -7.5)

20.6

-

3126.6

... More
SOR 4.17 Making plinth protection 50mm thick of cement concrete grade M10 over 75mm bed of dry metal ballast 40mm nominal size well rammed and consolidated and filled with sand including finishing the top smooth (with 20mm nominal size graded stone aggregate.) -

167.4

-

315.9

... More
SOR 5.16.6 Reinforcement for R.C.C. work including straighten Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding up to floor two level including cost of binding wire,all wastages and lappages/ overlaps (overlaps shall be provided as per reqirement of IS 13920 for ductile detailing, IS 546 RCC Design & SP 34 Reinforcement detailing) etc. complete. (Note:- Spacer bars (Chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge.)-Thermo-Mechanically Treated bars.(TMT) FE 500 D Confirming to IS 1786

8463

-

60

... More
SOR 5.44.1.1 RCC with Shuttering: Providing and laying/erecting All work up to Plinth level (14 raft pedstal,rcc grain, rcc retaining wall rcc abutments rcc pires ,plinth bem grades slab certain wall poles RCC barniner etc M-20 Ammendment

44.27

-

5000

... More
SOR 5.44.2.1 RCC with Shuttering: Providing and laying/erecting ABOVE PLINTH UPTO FLOOR TWO LEVEL WALLS (ANY THICKNESS ) COLUM,POSTS AND STRUTS ETC Ammendment M-20

7.11

-

5270

... More
SOR 5.44.3.1 RCC with Shuttering: Providing and laying/erecting SUSPENDED FLOORS ROOFS HAVING SLEPE OF ANY DEGREE LANDINGS BALCOMES ACCESS PLATFORM FLOOR BEAM GIRDERS BRESSUMERS AND CANTILEVERS SHELVES CHAJJS LINTELS BANDS STAIRSCASES AND SPIRRAL STAIRS CASES STAB Ammendment M-20

33.4

-

5390

... More
SOR 6.15.3.2 Brick work with fly ash lime brick(FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor II level in : AMMENDMENT Having 50 kg/cm2 avg. compressive strenghts cement mortar 1 :4 (I Cement:4 sand) SOR : 6.18 Extra for providing and placing in position 2 Nos. 8mm dia. M.S. bars at every third course of half brick masonry.

7.2

-

573.3

... More
SOR 6.5.2 Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg /cm2 and water absorpt ion not more than 20% in foundation and plinth i/c curing etc complete. Cement Mortar 1:6 (1 cement : 6 sand).

0.27

-

3739.5

... More
SOR 6.7.3.2 Brick work with fly ash lime brick(FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor II level in : AMMENDMENT Having 50 kg/cm2 avg. compressive strenghts cement mortar 1 :6 (I Cement:6 sand)

37.08

-

3990

... More
SOR 9.114.2 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Twin rubber stopper

7

-

77.4

... More
SOR 9.19.1 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of such as duro board, century or equivelant make. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.

8.19

-

2180.7

... More
SOR 9.43.1 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.

486

-

81.9

... More
SOR 9.5.2.1 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws excluding, panelling/glazing which will be paid for separately, all complete as per direction of Engineer-in-charge. Kiln seasoned and chemically treated Haldu, Kail, Bija wood.: 35 mm thick shutters SOR : 9.6.2 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Kiln seasoned and chemically treated Haldu, Kail, Bija wood

3.78

-

3571.2

... More
SOR 9.65.1 Providing and fixing ISI marked stainless steel sliding door bolts with nuts and screws etc. complete : 300x16 mm

4

-

350.1

... More
SOR 9.65.2 Providing and fixing ISI marked stainless steel sliding door bolts with nuts and screws etc. complete : 250x16 mm

6

-

293.4

... More
SOR 9.66.1 Providing and fixing ISI marked stainless steel tower bolt black finish, (Barrel type) with necessary screws etc. complete : 250x10 mm

4

-

133.2

... More
SOR 9.69.1 Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete : 125 mm

14

-

54

... More
SOR 10.2 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

130

-

61.83

... More
SOR 11.22.2 Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish wherever required etc. complete at all levels. samples approved by Engineer-in-charge. Granite of any colour and shade

2

-

2989.8

... More
SOR 11.36.2 Providing edge moulding to 18mm thick marble stone counters, Vanities, window sills etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work.

4

-

242.1

... More
SOR 11.45 Providing and laying Ceramic glazed floor tiles 300x300 mm or more (having thickness 6 to 7mm) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching pigment etc., complete.

6

-

547.2

... More
SOR 11.46 Providing and fixing Ceramic glazed wall tiles 300x450 mm or more (having thickness 6 to 7 mm) of 1st quality conforming to IS : 15622 of approved make in all Colours shades, Except burgundy, Bottle green, Black, laid on 12mm thick bed of Cement Mortar 1:3 (1 Cement : 3 sand) prepared same day when mortar is still green i.e. within 6 hours and jointed with grey cement slurry @3.3 kg per sqm including pointing the joints with white cement and matching pigments etc., complete.

26.23

-

644.4

... More
SOR 11.92.1 b Providing and laying vitrified tiles full body Homogenous Body matt/ rustic finish in different sizes with water abosrption less than 0.05% and confirming to IS 15622 of approved make in all colours and shades 1st quality premium in flooring laid on 20mm thick cement mortar 1:4 (1 cement: 4 sand) including grouting the joints with white cement and matching pigements etc. complete for indoors. In light colours and shades as ivory, beige blanco, grey etc.: Size 600 x 600 mm thickness 9-10 mm

148.65

-

995.4

... More
SOR 12.26.1 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 sand : 4 stone aggregate 10mm and down grade) including finishing with cement mortar 1:3 (1 cement : 3 sand) as per standard design : In 75x75mm deep chase

16.2

-

89.1

... More
SOR 13.1.2 12 mm cement plaster of mix : 1:6 (1 cement : 6 sand)

365.01

-

99

... More
SOR 13.3.2 20 mm cement plaster of mix : 1:6 (1 cement : 6 sand)

174.36

-

140.4

... More
SOR 13.41 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, Like birla white /JK white or equivalent, over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete.

751.7

-

66.6

... More
SOR 13.46.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer.

751.7

-

21.6

... More
SOR 13.49.1 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work

444.74

-

57.6

... More
SOR 13.55.1 Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).

325.27

-

78.3

... More
SOR 13.68.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work

48.96

-

47.7

... More
SOR 13.8.1 6 mm cement plaster of mix : 1:3 (1 cement : 3 sand)

217.535

-

86.4

... More
SOR 21.1.1.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion.: Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15)

130

-

317.7

... More
SOR 21.1.2.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately).: Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15)

65

-

360

... More
SOR 21.3.1 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 4.0 mm thickness

31.5

-

764.1

... More
SOR 22.7.1 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finish With average thickness of 120mm and minimum thickness at khurra as 65 mm.

145.5

-

796.5

... More
SOR 12.32.1 Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 75 mm diameter (minimum wall thickness 1.8mm)

26

-

122.4

... More
SOR 12.32.2 Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm diameter (minimum wall thickness 2.2mm)

55

-

214.2

... More
SOR 12.33.1.1 Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler: 75 mm (minimum wall thickness 1.8mm)

8

-

105.3

... More
SOR 12.33.1.2 Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler: 110 mm (minimum wall thickness 2.2mm)

12

-

138.6

... More
SOR 12.33.3.1 Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee with door: 75x75x75 mm (minimum wall thickness 1.8mm)

2

-

207

... More
SOR 12.33.3.2 Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee with door: 110x110x110 mm (minimum wall thickness 2.2mm)

4

-

311.4

... More
SOR 12.33.5.1 Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5°: 75 mm bend (minimum wall thickness 1.8mm)

8

-

105.3

... More
SOR 12.33.5.2 Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5°: 110 mm bend (minimum wall thickness 2.2mm)

15

-

154.8

... More
SOR 17.1.1 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or S trap, uPVC P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.

2

-

2695.5

... More
SOR 17.11.4 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap.

3

-

1497.6

... More
SOR 17.61.1 Providing and fixing uPVC trap of self cleaning design complet. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet

10

-

465.3

... More
SOR 18.32.1 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore

3

-

437.4

... More
SOR 18.49 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank

1000

-

6.3

... More
SOR 18.52.1 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore.

10

-

412.2

... More
SOR 18.8.2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 20 mm nominal outer dia .Pipes.

40

-

210.6

... More
SOR 18.8.3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 25 mm nominal outer dia .Pipes.

25

-

259.2

... More
SOR 19.7.1.1 Providing and fixing square-mouth S.W. gully trap class SP1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type: With well burnt bricks

2

-

1587.6

... More
SOR 19.9.1.2 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With Sewer bricks conforming to IS : 4885

4

-

6972.3

... More
SOR 4.1.a Point wiring (excluding metallic switch box & sheet but including switches, sockets,lamp holders/ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :- Light Point/Fan Points. a) Short point Modular

10

-

354.6

... More
SOR 4.1.b Point wiring (excluding metallic switch box & sheet but including switches, sockets,lamp holders/ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :- Light Point/Fan Points. b) Medium point Modular

10

-

603.9

... More
SOR 4.1.c Point wiring (excluding metallic switch box & sheet but including switches, sockets,lamp holders/ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :- Light Point/Fan Points. c) Long point Modular

25

-

974.7

... More
SOR 4.2.a Point wiring (excluding metallic switch box & sheet but including switches, sockets,lamp holders/ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :- 3 Pin 6 Amp socket outlet on Separate Board a) Short point Modular

2

-

452.7

... More
SOR 4.2.b Point wiring (excluding metallic switch box & sheet but including switches, sockets,lamp holders/ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :- 3 Pin 6 Amp socket outlet on Separate Board b) Medium point Modular

2

-

702

... More
SOR 4.2.c Point wiring (excluding metallic switch box & sheet but including switches, sockets,lamp holders/ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :- 3 Pin 6 Amp socket outlet on Separate Board c) Long point Modular

8

-

1072.8

... More
SOR 4.5 Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. Socket outlet point with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board . Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. Socket outlet point with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board-Using Flush Type Normal Accessories Modular

6

-

256.5

... More
SOR 4.6.A Point wiring (excluding metallic switch box & sheet but including switches, sockets,lamp holders/ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :- 3 Pin 6 Amp socket outlet on Separate Board Wiring for circuit wiring with PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size etc. as required as per specification-Using Flush Type Normal Accessories:2x2.5 Sq.mm.

150

-

105.3

... More
SOR 9.1.c Point wiring (excluding metallic switch box & sheet ) for 3 Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Concealed rigid P.V.C.Conduit (HMS) ISI Marked of suitable size etc. with 16 Amp. F.T. Switch & Socket / S.S.Combined 6/16 Amp. of ISI Marked and 4 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit as per specification for On Separate Board C. Long Point

3

-

1737

... More
SOR 9.1.d Point wiring (excluding metallic switch box & sheet ) for 3 Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Concealed rigid P.V.C.Conduit (HMS) ISI Marked of suitable size etc. with 16 Amp. F.T. Switch & Socket / S.S.Combined 6/16 Amp. of ISI Marked and 4 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit as per specification for On Separate Board D. Extra Long -I

4

-

2378.7

... More
SOR 9.1.e Point wiring (excluding metallic switch box & sheet ) for 3 Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Concealed rigid P.V.C.Conduit (HMS) ISI Marked of suitable size etc. with 16 Amp. F.T. Switch & Socket / S.S.Combined 6/16 Amp. of ISI Marked and 4 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit as per specification for On Separate Board E. Extra Long -II

3

-

3075.3

... More
SOR 9.2 Same board switch socket 6/16 Amp Using Flush Type Normal Accessories

2

-

191.7

... More
SOR 16.1 Supplying and fixing PVC conduit ISI marked alongwith the accessories in concealed system etc. as required PVC . Conduit 20 mm (HMS)

20

-

54.9

... More
SOR 16.2 Supplying and fixing PVC conduit ISI marked alongwith the accessories in concealed system etc. as required PVC . Conduit 25 mm (HMS)

50

-

64.8

... More
SOR 18.2.4 Supplying and fixing of approved make modular type metal box with modular frame/ base plate and cover plate including fixing in concealed / surface excluding switch,socket etc. as required for:- 6 Module

11

-

293.4

... More
SOR 18.2.6 Supplying and fixing of approved make modular type metal box with modular frame/ base plate and cover plate including fixing in concealed / surface excluding switch,socket etc. as required for:- 12 Module

2

-

438.3

... More
SOR 18.2.8 Supplying and fixing of approved make modular type metal box with modular frame/ base plate and cover plate including fixing in concealed / surface excluding switch,socket etc. as required for:- 18 Module

6

-

504

... More
SOR 23.1.3 Wiring for sub-mains with PVC insulated cable FR with copper multi strand conductor ISI marked in recessed / concealed rigid PVC conduit (HMS) ISI marked of suitable size(Conduit included) including 2mm thick accessories, connection etc ,as required as per specification 2 WIRE SUB-MAIN 6.0 sq mm cable in 25 mm conduit

60

-

154.8

... More
SOR 23.1.4 Wiring for sub-mains with PVC insulated cable FR with copper multi strand conductor ISI marked in recessed / concealed rigid PVC conduit (HMS) ISI marked of suitable size(Conduit included) including 2mm thick accessories, connection etc ,as required as per specification 2 WIRE SUB-MAIN 10.0 sq mm cable in 25 mm conduit

150

-

216.9

... More
SOR 26.1.6 Supplying of metal clad ISI Marked busbar chamber made of heavy gauge iron sheet complete with copper strip and busbar supports as per specification confirming to IS -4064 400 AMP 415 VOLTS, 4 way

1

-

10731.6

... More
SOR 27.12.2 Supplying & fixing of approved make Industrial type metal plug & socket DBs (without MCB) SPN sheet encloser (dust protected ) inclusive of 2 pole and earth metal plug and socket and space to incorporate SP MCB complete as per specification as required. 20 Amps

6

-

982.8

... More
SOR 27.5.1.2 Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS : 8828 : 1996, IEC : 60898 :2002 but without enclosures :- SINGLE POLE (SP) 6 Amp to 32 Amp Rating

30

-

184.5

... More
SOR 27.5.6.4 Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS : 8828 : 1996, IEC : 60898 :2002 but without enclosures :- FOUR POLE(FP) 50 Amp to 63 Amp Rating

11

-

1777.5

... More
SOR 27.9.2 Supplying of approved make Vertical TPN MCB DB Metal Double Door IP 43 protection with provision for FP CB/Isolator/RCCB/RCBO as incomer and SP/TP MCBs as outgoing inclusive of Busbar, Neutral bar, Earth bar & two earth terminals etc. complete as per IS:13032( exclusive of MCB & isolator ) 8 way (8+24)

1

-

8325

... More
SOR 29.31.2 Supplying and fixing of approved make step type Modular electronic Fan regulator including connection etc. as required on existing board 100 Watt (2 module)

13

-

620.1

... More
SOR 31.4.2.1 Supplying, fixing and testing of approved make surface mounting mirror optics luminaires for single/twin 28 watt T-5 fluorescent lamp comprising of white powder coated CRCA sheet steel housing raw silk / navy brown / white colour M.S. low profile flat housing complete with all accessories i.e. electronic ballast (HF), PF 0.95, THD 30%, duly wired (without tube rod) and high purity anodised aluminium reflector assmebly along with cross louvers as per specification and fixing as below. Fixing by stiff pendant arragement with two pieces of steel conduit 19/20mm dia 16 SWG and other necesssary materials such as ball socket, T.W. block with 'J' hook/ Anchor hole fastner fixed in Ceiling including connections and as required for length upto 1.5 Meter. 1x28w

23

-

2385.9

... More
SOR 37.1 Earthing with G.I. Earth pipe 4.5 Metre long and 40 mm dia with masonary enclosure in cement mortor, cover plate having locking arrangment on the top etc.(but without charcoal or coke and salt) complete as required.

1

-

2715.3

... More
SOR 37.2.1 Add Extra for using salt and charcoal / coke for pipe earth electrode as required including excavation & refilling. Excavation 2.5 cum by manual labour

1

-

1414.8

... More
SOR 37.2.2 Add Extra for using salt and charcoal / coke for pipe earth electrode as required including excavation & refilling. Excavation by making hole with Auger

1

-

961.2



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.