Military Engineer Services Tender
... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Repair/ Maintenance Of Garden Light Post Top Lantern Light In Mes Ib And Other Otm And Md Accn Connected Items Under Ge (mcte) Mhow in Indore, Madhya Pradesh, with an estimated contract value of Rs. 20,00,000. The bid opening date for this tender is 29-05-2025 and the last date for bid submission is 19-06-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 May 2025
Closing Date19 Jun 2025
Tender Amount₹ 20,00,000
Costs
EMD
₹ 40,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_711051_1Tender No
GE(MCTE)/MHOW/15(T) OF 2025-26Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
S&F in repair MCCB 4 pole, 415 volts, in the existing panel/ location and connection with using aluminum lugs complete all as specified and directed for 100 Amps rating, 16 KA breaking capacity complete all as specified and directed.
6
105
-
... More
S&F in repair flush mounting factory made Vertical FP MCCB DB, IP-42 Protection -IK 09 with metal double door with 200 Amps rated copper busbar with 2 neutral bar, earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing with provision of sapce for 100-125 Amps MCCB as incomer and SP/TP MCBs as out going 4 way inlcuding making good disturbed surafce to match with the existing colours complete all as specified and directed.
1
106
-
... More
Supply and fix in repairs double door SPN DBs 4 ways of powder coated DB's suitable for MCB's fitted with bus bar, Neutral link, Earth bar and Din ral inlcuding making good disturbed surafce to match with the existing colours complete all as specified and directed.
5
107
-
... More
Supply and fix in repairs double door SPN DBs 8 ways of powder coated DB's suitable for MCB's fitted with bus bar, Neutral link, Earth bar and Din ral inlcuding making good disturbed surafce to match with the existing colours complete all as specified and directed.
2
108
-
... More
S&F for MCB tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and directed.
3
109
-
... More
S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and directed.
30
110
-
... More
S&F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and directed.
40
111
-
... More
S & F in repair PVC insulated cable three core copper conductor of size 1.0 sqmm, covered with round insulation complete all as specified and directed.
100
112
-
... More
S & F in repair PVC insulated cable three core copper conductor of size 0.75 sqmm, covered with round insulation complete all as specified and directed.
100
113
-
... More
Supply in repair Flexible PVC Conduit pipe suitable & used for cover/ laying electrical wiring etc. of soze 25mm dia, complete all as specified and directed.
3
114
-
... More
S&F in repair sheet moulding compound (SMC) junction box, suitable for terminating 2 Nos 4 x 6/10 Sqmm UG electric cable including cable glandes- 2 Nos, and two way connector 1 No incl taking down old unsv complete all as specified and directed.
25
116
-
... More
Supply and fixing in repair GI pipe light grade 50mm bore in short lengths 'medium grade in length of segments of required size of each with making split holes, cut or threads at both end of pipe as required for post top lights in Gate/ Garden including all fixing arrangments like clamps, nuts, bolts etc incl. painting of pipe with two coats of synthetic enamel silver colour paint over one coat of primer complete all as specified and directed.
45
117
-
... More
M&L for Sub main wiring with two runs of single core FRLSH PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in existing PVC conduit including one run of PVC insulated unsheathed 4 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly in and making good disturbed surface of wall including taking down old sub main wiring complete all as specified and directed.
Note:- Two runs of 4.00 Sqmm cable, one run of 2.50 Sqmm cable will be measured as one unit.
50
118
-
... More
All as per item No.16 here in above but of 2.5 Sqmm complete all as specified and directed.
Note:- Two runs of 2.5 Sqmm cable, one run of 1.5 Sqmm cable and one run of PVC conduit will be measured as one unit.
90
119
-
... More
All as per item No.16 here in above but of 1.5 Sqmm complete all as specified and directed.
Note:- Two runs of 1.5 Sqmm cable, one run of 1 Sqmm cable and one run of PVC conduit will be measured as one unit.
160
120
-
... More
S&F in repair of LED Bollard garden lights fittings, made out of Cast Aluminum body finished with Polyurethane Paint (With Prior Treatments) with acrylic window cover. B-22 porcelain holder provided with aluminum cover. As Per : IS 10322 PART-5 SECTION-1 LATEST 2017 suitable for LED bulb including LED bulb 12 watts complete all as specified and directed.
18
121
-
... More
Sppply & Laying XLPE insulated, armoured, electric cable with aluminium conductor, 1100 volts grade, laid in trenches, fixed on poles/ walls or passing through pipes including provision of necessary lugs and glands & making necessary connection including taking down old unservicable cable of any core complete all as specified and directed for the following :-
-
-
-
... More
(a) 06 Sqmm 2 core.
300
123
-
... More
(b) 10 Sqmm 2 core
300
124
-
... More
(c) 16 Sqmm 4 core
150
125
-
... More
Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc and getting out in any type of soil complete all as specified and directed.
81
126
-
... More
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
51.57
127
-
... More
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
29
128
-
... More
M&L for clean and dry sand (un-washed) in trenches incl spreading and levelling for cushioning of UG cable complete all specified and directed.
22.68
129
-
... More
M & L for brick size sub class ‘B’ (modular size), laid flat in trenches for protection of cable complete all as specified and directed.
3.33
130
-
... More
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate No 3 of SSR part-I including excavation and earthwork in any type of soil/ strata and testing on completion incl taking down old unsv earthing complete all as specified and directed. Note:- GI earth wire 4mm dia and 15mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.
2
131
-
... More
Supply and fixing in repair LED Bldg Security/ street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
19
132
-
... More
Supply and fix in repairs Post Top Lantern 25 watts fully aluminium cast body finished with polyurethane paint (with prior treatment) with acrylic window cover. Total length 635mm and Max breadth 323mm, heritage look, spigot entry 78mm as per IS 10322 complete incl altration in mounting by welding/ threading/ placing addl GI socket to place lantern truely vertical in position complete all as specified and directed.
12
133
-
... More
S&F GI pipe 65mm dia medium grade of suitable length as directed at site and making standing pole for post top lantern in existing RCC pillar with necessary breaking of RCC pillar top, cutting Existing GI Pipe 50mm size, welding with 65mm GI pipe including fixing FRP looping box at bottom of pillar, casting of PCC, making good disturbed surface with PCC, cementing, Plastering including painting complete all as specified and directed.
Note:- PCC, GI pipe 65mm, Necessary excavation and FRP looping box will be measured and paid seperrately as per relevent item in schedule.
10
134
-
... More
M&L for surface/ recessed mounted LED fitting 36 watts, 2 ft x 2 ft fittings suitable for RCC ceiling, lumen out put ≥ 110 lumen/ watt,THD < 10% environmental friendly, new generation, aesthetically designed, ultra modern surface/ recess mounting luminaire with high brightness SMD LEDs as light source, incl inbuilt drivers incl original white and warm light as per site requirement and making good of disturbed surfaces during installation including taking down old light complete all as specified and directed.
35
136
-
... More
Supply and fix in repair Architectural designed poles (MCPL-02 with CDPB-04 with one No PTL-003(at middle) and Two Nos PTL-03, aluminium cast extra heavy duty pole mounted post top lantern incl heavy duty leg and broader designer base finished with polyurethane paint (with prior treatments) Diameter of pole leg is approx 65mm at at edges is approx 75mm. Outer dia for spigot entry 60mm 03 Nos T shaped bolts with nuts and washers provided for concrete foundation. Total length of the pole including base and Legs is approx 2515mm and CDPB-04 projection breadth of 950mm, Including 01 No Post top lantern Model No PTL003 (at middle) and 02 Nos post top lantern model PTL03 along with squre junction made out of aluminium finished with max projection breadth of 880mm suitable for three Nos post top lantern complete all as specified and directed.
Model No of Pole : MCPL 02 and model no of squre junction is CDPB04 of Mepro electricals/ equivalenet in Crompton/ Wipro/ Philips/ Havells/ Bajaj
6
137
-
... More
S&F in repair Decorative gate light (Moon light) made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp B22 base with IP 65 protection with robust design and efficient light distribution and taking out old defective fittings and all necessary fixing arrangements complete all as specified and directed.
44
138
-
... More
M&L for PCC work 1:2:4 type B2 using 40mm grade stone aggregate in foundation and mass concrete complete all as specified and directed.
2.97
139
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%