Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Repair/ Replacement Of Lt Oh Line/ Lt Cable, Painting Of Lt Poles, Repair/maint Of Earthing, Mccbs, Lt Panel And Maint/repair Of Apfc Panel And Other Connected Works At New And Old Drde Gwalior Under Ge I Rnd Delhi in Gwalior, Madhya Pradesh, with an estimated contract value of Rs. 49,00,000. The bid opening date for this tender is 06-11-2026 and the last date for bid submission is 27-11-2026. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender - MP Tender

Opening Date6 Nov 2026
Closing Date27 Nov 2026
Tender Amount₹ 49,00,000 
Notes
Download

Costs

Description

Repair/ Replacement Of Lt Oh Line/ Lt Cable, Painting Of Lt Poles, Repair/maint Of Earthing, Mccbs, Lt Panel And Maint/repair Of Apfc Panel And Other Connected Works At New And Old Drde Gwalior Under Ge I Rnd Delhi

Contact

Unlock the Tender details

GEM & Bid Advisory Services

Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

Unlock the Tender details
... More
95 Sqmm to 150 Sqmm any core

1000

100

-

... More
Supply, laying, jointing and testing XLPE/ P.V.C insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes

-

-

-

... More
10 Sqmm 2 core

350

100

-

... More
16 Sqmm 4 core

320

100

-

... More
25 Sqmm 4 core

250

100

-

... More
35 Sqmm 3.5 core

470

100

-

... More
50 Sqmm 3.5 core

450

100

-

... More
70 Sqmm 3.5 core

500

100

-

... More
95 Sqmm 3.5 core

500

100

-

... More
120 Sqmm 3.5 core

250

100

-

... More
150 Sqmm 3.5 core

250

100

-

... More
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as specified and directed. Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers.

721.44

100

-

... More
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed

430.46

100

-

... More
Removal of surplus excavated soil exc. 50 mtr but n. exc. 250 mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 M above the starting point etc complete all as directed.

290.98

100

-

... More
M & L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed . Note: - Punned thickness shall be measurement & paid.

216.43

100

-

... More
Supplying & Laying Sub Class `B’ designation x 75 bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection all as specified and directed

18

100

-

... More
Supply and laying in replacement of GI pipe light grade of 80mm dia laid in trenches for protection of UG cable complete

20

100

-

... More
All as per item No 8.00 but GI pipe 50 mm diameter complete

20

100

-

... More
Disconnecting LT cable of size from 16 Sqmm 4 core to 35 Sqmm 3.5 core from existing panel taking out loop of cable not more than 2.5 M length, cut the worn out portion of cable including replacement the lugs,nut-bolt and wasers of suitable size and reconnect the existing system

6

100

-

... More
Disconnecting LT cable of size from 50 Sqmm 3.5 core to 95 Sqmm 3.5 core from existing panel taking out loop of cable not more than 2.5 M length, cut the worn out portion of cable including replacement the lugs,nut-bolt and wasers of suitable size and reconnect the existing system

6

100

-

... More
Disconnecting LT cable of size from 120 Sqmm 3.5 core to 240 Sqmm 3.5 core from existing panel taking out loop of cable not more than 2.5 M length, cut the worn out portion of cable including replacement the lugs,nut-bolt and waser of suitable size and reconnect the existing system

6

100

-

... More
Disconnecting LT cable of size from 300 sqmm 3.5 core to 400 Sqmm 3.5 core from existing panel/ transformar/LT Pols and taking out loop of cable not more than 5 M length, cut the worn out portion of cable including replacement the lugs,nut-bolt and waser of suitable size and reconnect the existing system

4

100

-

... More
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60 cm x 6.0 mm buried in the ground to a depth not less than 2.25 mtr below ground level connected to GI 25 x 4 mm strip by means of GI nut, bolts, washers and check nut including GI Pipe pipe 40mm diameter medium grade for earth strip protection pipe complete as shown in electric plate No 03 of Sl- Part-I including 20 mm dia GI pipe medium grade for watering, unnel and PCC of 1:3:6 type C1 pit cover with RCC (1:2:4) cover of size 30cm x 30cm x 40mm with one handle for lifting made out of 8mm dia MS bar including charcoal and salt in alternative layers including all earth work for excavation and removal of surplus soil and Testing Point complete all as specified and directed.

14

100

-

... More
M & L in repairs Earthing complete with galvanished earth plate electrode of size 600 x 600 x 6.00 mm buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth strip 32 x 6mm as earthing lead by means of bolts, nuts, check nuts and galvanised iron or steel including earth work in any type of soil, PCC work in (1:3:6) pit and RCC (1:2:4) type B-1 pit cover reinforced with 6mm diameter ms bar 75 mm c/c 10 mm diameter handle, charcoal salt 15cm alternate layer and around the earth plate as shown in electrical plate no 3 of SSR Part I 2010, 20mm diameter watering pipe medium grade 1.70 mtr long GI protection pipe light grade 40mm dia from earth pit to main board including necessary pit cover complete all as specified and as directed.

14

100

-

... More
Earth continuity conductor passing through PVC Conduit of size 25 mm main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 25x4 mm galvanised iron strip complete all as specified and directed by Engr-in-Charge.

60

100

-

... More
S&F MCB TP (25-63) Amps 10 KA 'C' Series 415 Volts all as specified .

20

100

-

... More
Supply and fix in replacement of 3 Pole MCCB,100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and as directed.

14

100

-

... More
S&F in repairs MCCB 125 Amps 3 pole, 415 V, breaking capacity 16 KA & connected accessories complete as specified and as directed

12

100

-

... More
All as per item No 19.00 above but MCCB of cap 3 Pole 160 Amp, 36 KA

16

100

-

... More
All as per item No 19.00 above but MCCB of cap 3 Pole 200 Amp, 36 KA

18

100

-

... More
All as per item No 19.00 above but MCCB of cap 3 Pole 250 Amp, 36 KA

18

100

-

... More
S&F in repairs MCCB 350 Amps, 3 Pole, 415 V, Adjustable type, with breaking capacity 36 KA including spreader terminals & connected accessories complete as specified & directed.

8

100

-

... More
All as per item No 23.00 above but MCCB of cap 3 Pole 400 Amp, 36 KA

6

100

-

... More
All as per item No 23.00 above but MCCB of cap 3 Pole 630 Amp, 50 KA

3

100

-

... More
Supply and fix in replacement of 4 Pole MCCB, 160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA. complete all as specified and as directed.

8

100

-

... More
All as per item No 26.00 above but MCCB of cap 4 Pole 400 Amp, 36 KA

8

100

-

... More
All as per item No 26.00 above but MCCB of cap 4 Pole 630 Amp, 50 KA

5

100

-

... More
Supply and fixing of Aluminium thimble of size 35 sqmm for terminal end of cable complete all as specified and directed.

38

100

-

... More
Supply and fixing of Aluminium thimble of size 50 sqmm for terminal end of cable complete all as specified and directed.

35

100

-

... More
Supply and fixing of Aluminium thimble of size 70 sqmm for terminal end of cable complete all as specified and directed.

35

100

-

... More
Supply and fixing of Aluminium thimble of size 95 sqmm for terminal end of cable complete all as specified and directed.

30

100

-

... More
Supply and fixing of Aluminium thimble of size 120 sqmm for terminal end of cable complete all as specified and directed.

28

100

-

... More
Supply and fixing of Aluminium thimble of size 150 sqmm for terminal end of cable complete all as specified and directed.

30

100

-

... More
Supply and fixing of Aluminium thimble of size 185 sqmm for terminal end of cable complete all as specified and directed.

28

100

-

... More
Supply and fixing of Aluminium thimble of size 240 sqmm for terminal end of cable complete all as specified and directed.

28

100

-

... More
Supply and fixing of Aluminium thimble of size 300 sqmm for terminal end of cable complete all as specified and directed.

25

100

-

... More
Supply and fixing of Aluminium thimble of size 400 sqmm for terminal end of cable complete all as specified and directed.

25

100

-

... More
Supply and Fix earth pit chamber alongwith cover of Polymer, FRP Pit Cover of heavy high grade polypropylene for high stress and strain level of size 225mm x 300mm x 195mm complete all as specified and directed.

20

100

-

... More
Restringing of existing ACSR’s conductors and earth wires including cradles, of any description, size & shape and in any portion, as in LT/HT overhead lines, on existing poles, including opening of connections and binding wires, restringing and tightening of conductors/earth wire in portion, removing sag, binding to insulators with new aluminum wire, making and connecting jumper connections etc. including testing complete all as specified and directed. The quoted rates shall be deemed to include the following provisions also :- (i) Setting/adjusting etc in portion of cradles. (ii) Old serviceable spacers of ACSR conductor shall be reused and fixed all as directed

2500

100

-

... More
Dismantling & taking down of existing worn out / unserviceable aluminium conductor, steel reinforced (ACSR) of any description /size & in any portion from existing LT/HT Poles/Lines complete all as specified and directed.

1.5

100

-

... More
Supply and fixing of aluminium conductor, steel reinforced (ACSR) of any size/description on LT poles/lines including stringing, tightening, binding to insulators with aluminium wire making and connecting jumpers, connections etc including connecting, commissoning and testing complete all as specified & directed by Engineer-in-Charge. Note:-Old serviceable spacers obtained from taking down of ACSR conductor under item No.42 shall be reused and fixed complete all as specified and directed by Engineer-in-Charge.

1.5

100

-

... More
Re-Fixing and stringing of old ACSR’s conductors and earth wires including cradles, of any description, size and shape and in any portion, as in LT/HT overhead lines, on existing poles, including opening of connections and binding wires, restringing and tightening of conductors/earth wire in portion, removing sag, binding to insulators with new aluminum wire, making and connecting jumper connections etc. including testing complete all as specified and directed. The quoted rates shall be deemed to include the following provisions also :- (i) Setting/adjusting etc in portion of cradles. (ii) Old serviceable spacers of ACSR conductor shall be reused and fixed as directed by Engineer-in-Charge

1

100

-

... More
Dismantling & taking down of existing worn out / unserviceable GI wire of any description/size & in any portion from existing LT/HT Lines including cradle guard wires all as specified & directed.

2

100

-

... More
Material and labour for supplying, stringing and fixing GI continuous GI earth wire of size 4 mm / 3.15 mm diameter on LT/HT poles as in cradle guards / earth wires etc including binding complete all as specified and directed.

2

100

-

... More
Dismantling & taking out of old existing unserviceable steel & iron items from poles such as cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts and bolts, washers of any description and in any portion from LT over head line poles/ street light poles complete all as specified and directed by Engineer-in-Charge.

2

100

-

... More
Fixing Only old serviceable steel and iron, mild steel such as cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts & bolts, washers and encluding painting with one coat of synthetic enamel paint complete all as specified and directed by Engineer -in-Charge.

2

100

-

... More
Supply, fabrication and fixing for mild steel such as cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts and bolts, washers of any description of LT over head line poles/ street light poles complete all as specified and directed by Engineer -in-Charge.

2

100

-

... More
Dismantling and taking out of old existing unserviceable insulators of any description and in any portion from LT/HT poles complete all as specified and directed.

50

100

-

... More
S&F single disc assembly for disc type insulator porcelain vitreous 145mm high and 255mm dia ball and socket type, white , brown or green HT 11 KV grade all as specified and directed by Engineer-in-Charge for HT overhead lines.

12

100

-

... More
S&F pin type porcelain, vitreous, white, brown or green insulators, including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut, 150mm height and 150mm dia suitable for working pressure upto and including 11000 volts grade complete all as specified for HT lines fixed on poles.

12

100

-

... More
Description all as per item No 51.00 above but of size 100mm height and 65mm diameter suitable for 1100V grade complete all as specified for LT lines fixed on poles.

25

100

-

... More
S&F Shackle type 75mm height and 90mm diameter insulator, porcelain, vitreous, white, brown or green including galvanised mild steel strap 31mm x 3mm, insulator bolts 12mm diameter with suitable washers and nut, suitable for working pressure upto and including 1100 volts, complete all as specified and directed by Engineer-in-Charge fixed on LT poles.

25

100

-

... More
Disconnecting, dismantling and taking down existing unserviceable spacers of any description and in any portion from the LT electric overhead lines of any height and supplying and fixing new PVC insulated spacers, 12mm diameter flexible type suitable for making / turning to any shape and size and suitable for 2 or 3 conductor runs complete all as specified and directed.

25

100

-

... More
Description all as per item No 54.00 above but spacers suitable for five conductors run.

25

100

-

... More
Description all as per item No 55.00 above but PVC insulated straight strip type spacers suitable for five conductor run overhead lines. (Note for item No 54.00 to 56.00. The spacer shall be of best quality and as per the sample kept in GE office)

25

100

-

... More
Dismantling and Taking down existing unserviceable stay assembly and supply and fixing for stay assembly comprising of 16mm diameter, 1.80 metre long galvanized stay rod, having 7/3.15mm GI stay wire stranded and 230mm x 230mm x 6mm thick stay plate, complete all as shown on electrical plate No 1 of SSR, Part-I with and including all necessary fittings/ accessories like loop type insulator, stay clamps, necessary excavation and earth work in any type of soil and PCC works in (1:3:6) type C-2 (using 40mm graded stone aggregate) including taking down and dismantling old unserviceable stay assembly etc complete all as specified and directed by Engineer-in-Charge.

15

100

-

... More
Description all as per item No 57 here-in-before but stay assembly having stay rod of 20mm dia and 2.15 metre long with 300mm x 500mm x 6mm thick MS plate.

10

100

-

... More
Trimming/cutting of all trees branches and cleaning of buses upto 2 metre distance both side from nearest conductor/Earth wire at LT/HT overhead line including cleaning of site and depositing of material upto 250 metre distance all as directed at site by Engineer-in-Charge.

3500

100

-

... More
M&L for surface excavation,grass cutting over the areas around the poles/feeder piller boxes/ sub stations not exceeding 15cm depth including cleaning the bushes and vegetation/root of small trees and leveling incl removal of surplus soil in soft/hard dense soil.and deposited where 15 cm directed by Engineer-in-Charge

2700

100

-

... More
Dismantling and taking down existing unserviceable/worn out danger notice plate of any description and any portion and supply and fixing for danger notice plate 20 x 15cm size and 1.6mm thick mild steel vitreous enamelled white, with letters, figures and conventional skull and bones in SSRgnal red colour and fixed with including connected accessories complete all as specified and directed.

30

100

-

... More
Demolition for cement concrete/road in ground floor and paving not exceeding15 cm thickness below or above ground level including removal of rubbish to a distance exceeding 1.50 Km and not exceeding 5.00 Km etc complete all as specified and directed

2

100

-

... More
M & L for 100mm thick PCC (1:2:4) type B2 (using 40mm graded stone aggregate) complete all as specified and directed .

8

100

-

... More
M & L for 40mm thick PCC (1:2:4) type B1 (using 20mm graded aggregate) as in floor finishing even and smooth with using extra cement and making impression of expanded metal, whilst concrete making good as per existing surface etc complete all as specified and directed .

8

100

-

... More
S&F in repairs on load changeover with phase Barriers and Handle with door interlock kit is integral part of the Changeover Switch, with SS enclosure 1000 Amps, 4 Pole, 415V, AC, 50 Hz (confirm to IEC 60947-3, IS/IEC 60947-3) complete all as specified & directed.

1

100

-

... More
S&F in repairs ON load changeover with phase Barriers and Handle with door interlock kit is integral part of the Changeover Switch, with SS enclosure 800 Amps, 4 Pole, 415 V, AC, 50 Hz (confirm to IEC 60947-3, IS/IEC 60947-3) complete all as specified & directed.

2

100

-

... More
S&F in repairs ON load changeover with phase Barriers and Handle with door interlock kit is integral part of the Changeover Switch, with SS enclosure 400 Amps, 4 Pole, 415 V, AC, 50 Hz (confirm to IEC 60947-3, IS/IEC 60947-3) complete all as specified & directed.

2

100

-

... More
S&F in repairs ON load changeover with phase Barriers and Handle with door interlock kit is integral part of the Changeover Switch, with SS enclosure 315 Amps, 4 Pole, 415 V, AC, 50 Hz (confirm to IEC 60947-3, IS/IEC 60947-3) complete all as specified & directed.

2

100

-

... More
S&F in repairs ON load changeover with phase Barriers and Handle with door interlock kit is integral part of the Changeover Switch, with SS enclosure 250 Amps, 4 Pole, 415 V, AC, 50 Hz (confirm to IEC 60947-3, IS/IEC 60947-3) complete all as specified & directed.

2

100

-

... More
S&F automatic power factor control relay of 12 stage operating Voltage - 230V AC and current Input - 1A or 5 A,Steps- 12 relay outputs ,Supply Voltage - 1Ph 415V AC (-40% to +20% ),Measurement Voltage : 3Ph 3 wire 415 VAC (-40% to +20% ), Operating temperature : 0 to 70ºC , of M/S EPCOS CAT NO.BR6000, PFC CONTROLLER-BR-6000-R-12- Material Code - B44066R6012R 230N-1 or equivalent including testing, connecting, commissoning in such a way to avoid "controller hunting" complete as in repairs as specified and as directed having following features:- (a) Microcontroller logic for measurement. (b) User friendly operation. (c) Control mode : binary , unequal and user defined. (d) Multifunctional LCD display. (e) SSRngle CT senSSRng for balanced loads. (f) Individual harmonic measurement upto 15th order. (g) Three CT senSSRng for unbalanced load. (h) Dual target Power Factor setting useful for utility and DG mode operation, (j) Automatic synchronization. (k) Separate 3 CT monitoring of healthiness of Capacitor within Panel. (l) Data logging. (m) RS 232 in front and RS 232/485 switchable connection at rear. (n) Step operation indication on LCD display plus LED which facilitates viewing from a distance. (o) Unique facility of including Fixed Capacitor Bank' for purpose of Transformer compensation. This can be set such that the controller doesn't ‘see' this capacitor. (p) Unique external temperature senSSRng by PT100. (q) Settable alarm facility - undervoltage,overvoltage and so on. (r) Settable auxiliary outputs - 2 Nos for Alarm, etc. (s) Dynamic Power Factor Controller (TranSSRstorised) available in 16 steps without PT100 facility available. (t) EMI/EMC type tested.

3

100

-

... More
M&L for repair the Unserviceable APFC panel by servicing and renewals of burnt / U/s Power/Control wiring and spare parts to achieve Power Factor upto 0.99 for the capacity upto 75 KVAR complete all as specifies and directed by Engineer-in-Charge.

4

100

-

... More
All as per ser item No 71 here-in-before but for capacity 100 to 150 KVAR.

3

100

-

... More
All as per ser item No 71 here-in-before but for capacity 175 KVAR Note for item 71 to 73 (i) Rate quoted by contractor deemed to be included for renewal of burnt copper wiring, copper lugs and other necessary screws,nuts and bolts etc. (ii) The spare parts to be replaced shall be measured and paid separately as per respective items of the schedule. (iii) Penalty will charged @ Rs 100.00/day/panel till the completion of the work to contractor in case of average PF falling below 0.98 after the period of two months of the date of acceptance of tender.

2

100

-

... More
S&F in repairs 10 KVAR power factor correction capacitor Heavy Duty Long life rectangular box type, self standing units of modular construction with sheet metal enclosure, self healing property, PureSSR-N as impregnant with safety device in the form of pressure sensitive (over pressure) mechanical interrupter including wire for use on 440V (AC), 3 phase, 50 Hz,(Series B32459) AC conformance to Standards IEC 60831-1 2/96, IS 13340 with MPP film with heavy edge including testing, commissioning as in repairs complete all as specified and directed.

6

100

-

... More
All as per ser item No 74.00 here-in-before but of capacity 15 KVAR

6

100

-

... More
All as per ser item No 75.00 here-in-before but of capacity 20 KVAR .

6

100

-

... More
All as per ser item No 76.00 here-in-before but of capacity 25 KVAR

6

100

-

... More
S&F in repair power capacitor duty contactor 240V suitable for 10 KVAR including testing connecting commissoning complete all as specified and directed.

6

100

-

... More
All as per ser item No 78.00 here-in-before but for 15 KVAR .

6

100

-

... More
All as per ser item No 78.00 here-in-before but for 20 KVAR .

6

100

-

... More
All as per ser item No 78.00 here-in-before but for 25 KVAR

6

100

-

... More
S&F in repair HRC fuse link, Type HG, offset, size F1, 2 - 16 Amps cap base/holders complete all as specified and directed.

6

100

-

... More
S&F in repair HRC fuse link, Type HG, offset, size A2, 16 to 32 Amps cap, Fuse base/holders complete all as specified and directed..

6

100

-

... More
S&F in repair HRC fuse,Type HQ, offset, size A3, 35 to 63 Amps cap, Fuse base/holders complete all as specified and directed..

6

100

-

... More
S&F in repair HRC fuse,Type HQ,offset, size A4, 125 Amps cap, Fuse base/holders complete all as specified and directed..

5

100

-

... More
S&F in repair in repairs Fuse holder A2 type, suitable for 4 to 32 Amps bolted fuse links complete all as specified and directed. .

4

100

-

... More
S&F in repair Fuse holder A3 type, suitable for 35 to 63 Amps bolted fuse links complete all as specified and directed.

4

100

-

... More
S&F in repairs Fuse holder A4 type, suitable for 80 to 125 Amps bolted fuse links complete as in repairs all as specified and directed.

4

100

-

... More
S&F in repairs Solid state relay of 55 to 60 Amp swithing the capacitor bank complete all as specified and directed.

6

100

-

... More
S&F in repairs thyrestor controller relay 75 Amp complete all as specified and directed.

8

100

-

... More
S&F in repairs thyrestor controller relay 125 Amp complete all as specified and directed.

8

100

-

... More
M&L for control wiring of the panel with 440V 10 Sqmm PVC insulated stranded single core copper conductor cable (FR-LS) conforming to IS for power circuit, the wire ends will be copper ferruled including disconnecting and removing the unserviceable wire complete connecting testing all as specified and directed.

110

100

-

... More
All as per ser item No 92.00 here-in-before but 2.5 Sqmm cable.

100

100

-

... More
S&F digital Ammeter in replacement for measuring alternating current of range : 0 - 450 A flush type 96 x 96MM size.

6

100

-

... More
S&F digital Voltmeter in replacement for measuring alternating current voltage of range : Range 0-500 V flush type 96 x 96MM size.

6

100

-

... More
S&F in replacement voltmeter/ammeter selector switches suitable for Voltage between Phases with OFF, 16 Amps complete all as specified and directed.

6

100

-

... More
S&F in replacement indoor resin cast ring type current transformer of ratio 800/5 Amps, accuracy - 15VA, Class - 5P10 complete all as specified and directed.

6

100

-

... More
Painting to electric control panel of E/M installations by cleaning the existing old paint with the help of mechanical tools such as wire brush, scraper and sand paper from the surface of panel and painting the prepared surface with two coat of synthatic enamel paint of approved shade over a coat of red oxide primer complete all as specified and directed.

100

100

-

... More
M & L for sheet metal work for repair to electric panel doors, bus bar cover and accessories mounting supports for alignment with front door with 2mm thick MS sheet duly painted with super enameled paint over one coat of red oxide primer including necessary cutting, welding and fixing complete.

48

100

-

... More
S&F in repairs, Breaker control switch (Trip-Neutral-close), TNC with 2NO + 2NC SPR RTN complete all as specified and directed.

6

100

-

... More
S&F in replacement Rotary Type A/M Switch, 1 Pole, 2 Way with Off.

6

100

-

... More
S&F Flush head Push Button Green/Red colour with 1 NC Block, complete all as specified and directed.

15

100

-

... More
S&F in replacement multi function meter having LCD Display,96 x 96 sq.mm Flush mounted case, accuracy class 1.0 capable of measuring Instantaneous, Average, Maximum and Total Current from 50A to 6000A and voltage from 120V AC to 300V AC Phase to Neutral, Phase to Phase Voltage, Instantaneous, Average, Maximum and Total Active Power KW, Instantaneous, Average, Maximum and Total Reactive Power KVAR, Instantaneous, Average, Maximum and Total Apparent Power KVA, Instantaneous and Total Power Factor, Frequency complete all as specified and directed.

2

100

-

... More
S&F in repairs instrument Cooling fan , 3000 RPM, 230 Volts 50 Hz complete within the panel including cutting of a suitable sized hole on the panel body and wiring with 1.5 Sqmm copper conductor cable and MCB SPN 6 Amps all complete complete all as specified and directed.

5

100

-

... More
S&F in renewals capacitor cooling Exhaust fan 230 volts complete complete all as specified and directed.

5

100

-

... More
S&F in replacement LED indicator - R/Y/B/G 240 V AC complete all as specified and directed.

38

100

-

... More
M&L for repairing / servicing the existing U/S Air Circuit Breaker of 800 Amp capacity for proper functioning (tripping) on overload and earthfault by replacing the wornout parts, tighting all cable ends incuding replacing the U/S lugs etc, cleaning the dust by blower all as directed by Engineer-in-Charge. Note:- (i) Wornout/Us parts of ACB will be paid and measured separately under respective item of schedule. (ii) The servicing of ACBs will be done only throgh authrised rep of OEM. (iii) Item No 108 to 111 shall be paid separately under respective items

3

100

-

... More
Supply only Lockable trip push button (LTPB) kit of 800 Amps Air circuit breaker .

4

100

-

... More
Supply only contact spring.

6

100

-

... More
Supply only moving contact.

6

100

-

... More
Supply only Door interlock

5

100

-

... More
M&L for repairs to main electrical panel at sub stations by tightning the all loose connections of the cable ends and replacing the damaged/US/burnt aluminium lugs of required sizes, insulating/secure the weak insulated portion of cable inside the panel by taping with good quality of insulation tape, clean the dust by air blower all as specified and directed.

20

100

-

... More
Dismantling and Taking Out old unserviceable LT Panel and Supply, installation, commissoning and testing LT panel board of size 1200 x 1000 x 300 mm (Approx) for 3 phase, 4 wire, 415 Volts, AC, 50 Hz supply, Outdoor cubical type, dust and vermin proof, pedestal mounting type suitable for Outdoor applications having suitable shape/ size canopy on top, made out of 3.15 mm thick MS sheet with using 50mm x 50mm x 6mm angle iron frame and supports, duly finished with powder coated of approved colour over a coat of red oxide primer all over steel surfaces complete with separate compartment of suitable shape and size with shutter and locking arrangement for each switchgear and including PCC work for fixing panel legs 45 cm above ground level and Bus bar of aluminium conductor suitable shape and size for 3 phase rating of 600 amps and for neutral 400 Amps rating including taking out end connectinons of the existing cables and fixing the cable with the panel using new lugs and glands of suitable size, separate cable alley for outgoing cables including following switchgear & controls. (i) Incoming:- (a) Micro procecessor based MCCB,400 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 35/36 KA, with adjustable load setting - 01 No. (b) Ammeter three phase, digital electronic type, size of 96 mm X 96mm, rating of 0-600 Amps, and in built selector switch and 3 current transformer of suitable ratio and capacity - 1 No. (c) Indicating lamps LED type for three phases - Qty 1 set of 3 Nos (RYB). (d) Voltmeter, three phase, (0-500V) range digital electronic type with in built selector switch - 1 No. (ii) Out going:- (a) MCCB, 160 Amps, 4 pole 415 Volts AC supply ,having braking capacity lcu =25 KA -3 No. (b) MCCB, 125 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 16 KA - 3 Nos. (c) MCB, 63 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 16 KA - 5 Nos. (d) MCB, 40 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 16 KA - 6 Nos. (e) MCB, 32 Amps, SPN, 415 Volts, AC supply, having breaking capacity Icu = 16 KA - 4 Nos (F) MCB, 25 Amps, SSRngle pole, 415 Volts, AC supply, having breaking capacity Icu = 10 KA - 4 Nos Note for ser item No. 54 :- 1. Before fabrication of panel the contractor shall submit detailed general arrangement drawing and SSRngle line diagram of all panel for approval. A drawing shall also show foundation details, list of components in the manufacturer's refernce and bill of materials. 2. Panel should be manufactured by CPRI approved and manufacuturer's CPRI test certificate to be produced.

1

100

-

... More
Disconnecting & Taking out old U/S joints and Supplying, Fixing, jointing and testing for provision of straight through joints, epoxy type with epoxy jointing materials, suitable for XLPE, LT Cable, 1100 Volts grade, for the following sizes of cables all as specified and directed by the Engineer-in-Charge.

-

-

-

... More
10 Sqmm to 16 Sqmm 2 core

10

100

-

... More
25 Sqmm to 50 Sqmm 3½ core

20

100

-

... More
70 Sqmm to 120 Sqmm 3½ core

15

100

-

... More
150 Sqmm to 185 Sqmm 3½ core

10

100

-

... More
240 Sqmm to 300 Sqmm 3½ core

10

100

-



Evaluation Notes How It Works ?

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.