Military Engineer Services Tender

... More
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date9 Jun 2021
Closing Date18 Jun 2021
Tender Amount₹ 12,95,749 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for providing of suction kit as per manufacturer specification and required at site complete all as specified and directed by Engr-in-charge.

10

-

-

... More
S&F sensor for medical gas pipe line complete all as directed by Engr-in-charge. Make : Digiline/ Mediline /JK / MR Engineers

3

-

-

... More
S&F the following Terminal Outlet :-

-

-

-

... More
S&F Line aram system for Oxygen gas pipe line digital type with PCB and supply voltage of 220V and covering the distance of 50 meter complete all as directed by Engr-in-charge.Make : Digiline/ Mediline/ MR Engineers /JK

1

-

-

... More
15mm OD and thickness 1.0mm

100

-

-

... More
M&L earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x6.0mm thick buried directly under ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate at a depth not less than 1.5m below ground level connected to and including galvanized iron wire 4.0mm not exceeding 7.5meters for each earth without protection pipe, by means of bolts, nuts, check nuts, and washers made out of GI all as shown on plate No 5 of SSR Part I to the extent applicable to this item including necessary making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 6 mm dia MS bars 3 Nos both ways with lifting hook made out of 6 mm dia bar and complete all as specified and directed.

2

-

-

... More
S&F socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete. Make - Havells Reo / Anchor Penta PC / Indoasian as approved.

50

-

-

... More
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FR-SH multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into into including PVC casing-caping not less than 25x12 mm ISI marked of following nominal sizes (Cable Make : Havells / Polycab / Finolex / Plaza as approved):- (a) 2x6 sqmm + 1x6 sqmm earth wire.

45

-

-

... More
Supply, fixing,installation and testing Lloyd Certified and specified color painting Copper pipe of following dia :- Make : Maxflow/ Mandev/ Metalco

-

-

-

... More
22 mm dia

4

-

-

... More
S&F Isolating valves of brass fittings, ball types 1/4 turn handle operates for open and close position for following sizes complete all as directed by Engr-in-charge. Make : IN-RB/JK / Matrix/ Convex

-

-

-

... More
M&L for providing of cylinder key for opening and closing of gas cylinder in gas supply system complete all as directed. Make : GFLOW / Mediline/ JK / MR Engreeing

1

-

-

... More
12mm OD and thickness 0.8mm

15

-

-

... More
S&F of HP tube for medical gas supply system complete all as directed. Make : GFLOW / Mediline/ JK / MR Engreeing

2

-

-

... More
Supply, installation and testing of CENTRAL OXYGEN (O2) MANIFOLD SYSTEM (2x2) 4 cylinder Manifold for Oxygen complete with middle frame, bottom frame, NRV and HP Tail pipe complete all as directed by Engr-in-charge. Make : GFLOW / Mediline/ JK / MR Engineers

1

-

-

... More
12 mm dia

10

-

-

... More
15 mm dia

2

-

-

... More
Supply and fixing suction jar 600 ml made of clear polycarbonate, non toxic, screw-fit cap plastic and float assembly with float safety, cap inlet and outlet tubing connectors, O ring over the top of bottle for leak proof seal complete all as specified and directed by Engr-in-charge. Make : GFLOW / Mediline/ JK / MR Engreeing

1

-

-

... More
S&F high concentration Oxygen mask white colour comes with elastic band and nose clip with tube 2.1 mtr complete all as directed. Make : Meditech / Angiplast / Elanor

10

-

-

... More
Supply, install , testing and commissioning of vacuum pump capacity of 5 HP with tank capacity of 500 Kg for medical vacuum pipeline system should be design to maintain a vacuum of at least 300mm Hg (40 kPa) at each terminal unit complete all as specified and directed with following :- (a) Pump installation should be consisting of 5 HP dry type vacuum pump which shall be capable of independently producing disigned systems flow rate. (b) Pump should have capacity of minimum 130 cfm and capable of providing a vacuum of not less than 650mm Hg (87 kPa). (c) Vacuum pump shall have own its exhaust line and each shall be fitted with suitable drain valves and transparent jars at the lowest points. (d) The outlets shall be suitable protected to prevent the ingress or rain and wind pressure. (e) The exhaust system shall be designed so that the bach pressure does not exceed 80mm Hg (1.0 psi) at the design flow rate. (f) A length of flexible pipe work shall be included before the exhaust passes through a wall in order to isolate the building structure from pump vibration. Make : Panumatics Engineer/ IR/Comptech /DENTECH/ Drainvac

1

-

-

... More
S&F BPC flow meter (0-15 LPM) with Humidifier (oxygen line) capacity of 200 ml bottle complete all as specified and directed. Make : Meditech/ GFLOW / JK

10

-

-

... More
22mm OD and thickness 1.0mm

300

-

-

... More
S&F Terminal outlet for vaccum with probes and adapters made of copper as per OEM specification and complete all as directed by Engr-in-charge. Make : Meditech/ GFLOW / JK

10

-

-

... More
Supply, installation and testing of Emergency Oxygen (1x1) 2 cylinder manifold System Supply through regulator having non halogenated polymer in high pressure side complete all as directed by Engr-in-charge. Make : GFLOW / Mediline/ MR Engreeing/ Drager/ JK / OEM

1

-

-

... More
Supply and Installtion Aluminum Powder coated Bed Head Panel, iv pole and socket 5/15 Amp for provision of medical gas outlts and elcterical supply complete all directed by Engr-in-charge. Make : ABS System/ Fabtrix/ Pioneer Industries/ GFLOW / Mediline/ JK / MR Engreeing

10

-

-

... More
S&F switch piano flush button single pole one way 16 amp complete. Make - Havells Reo / Anchor Penta PC / Indoasian as approved.

50

-

-

... More
Supply, install and testing of Semi automatic manifold control Panel compliance with ISO 9001:2008 in SS enclosure for oxygen as designed both safety and continuity of flow supply at a constant pressure via bottled gas cylinder with monitoring of in use and ready for use indications. Panel build with LED display and two Nos of pressuer regulators and one line regulator high pressure gauge (4" dial) including all accessories as per manufacturer specification and complete all as directed by Engr-in-charge. Make : GFLOW / Mediline/ JK / MR Engreeing

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.