Military Engineer Services Tender

... More
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Building Construction
Eprocure
Opening Date17 Apr 2025
Closing Date2 Jun 2025
Tender Amount₹ 18,73,60,000 
Notes
Download

Costs

Summary

Provn Of Otm Accn Of Fd Hosp Phase One Of Two Phases At Bhopal Military

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part- II (Ref prepriced schedule attached seperately)

1

1329194

1329194.31

... More
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part- III (Ref prepriced schedule attached seperately)

1

2054983

2054983.62

... More
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part- IV (Ref prepriced schedule attached seperately)

1

270496

270496.13

... More
Lump sum price worked out by the contractor for EXTERNAL ELETRIC SUPPLY WORKS as listed in Schedule ‘A’ Part- V (Ref prepriced schedule attached seperately)

1

2954370

2954370.61

... More
Lump sum price worked out by the contractor for ROAD, PATH AND CULVERT WORKS as listed in Schedule ‘A’ Part- VI (Ref prepriced schedule attached seperately)

1

16054684

16054684.34

... More
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule ‘A’ Part- VII (Ref prepriced schedule attached seperately)

1

8488797

8488797.4

... More
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part-VIII (Ref prepriced schedule attached seperately)

1

1035175

1035175.33

... More
Lump sum price worked out by the contractor for COMPOUND WALL AND FENCING WORKS as listed in Schedule ‘A’ Part-IX (Ref prepriced schedule attached seperately)

1

3092464

3092464.27

... More
Lump sum price worked out by the contractor for EXCAVATION, EARTH WORK AND SITE DEVELOPMENT WORKS as listed in Schedule ‘A’ Part-X (Ref prepriced schedule attached seperately)

1

22160014

22160014.7

... More
SCH 'A' Pt - XI (MISCELLANEOUS ITEMS)

-

-

-

... More
INTERNAL ELECTRIFICATION WORKS NOTE:- For items of INTERNAL ELECTRIFICATION AND HOT WATER SUPPLY WORKS notes given at the beginning of Sch ‘A’ Part-III ( INTERNAL ELECTRIFICATION AND HOT WATER SUPPLY WORKS) shall also be applicable.

-

-

-

... More
M&L point wiring for light point wiring complete with 1.5 Sq.mmm PVC insulation unsheathed muilt-starnded FRLSH copper conductor 1100 Volts grade draw through in and including 20 mm dia PVC conduit and conduit accessories, concealed in walls and terminated to and including provision of modular metal flush boxes (metal switch board of any type and size) with modular metal frame plate and white cover for housing switch, sockets, regulators etc, including 1.5 sqmm PVC insulated unsheathed multi-stranded FRLSH copper conducotor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for the following points (Ser Item No 4.02 to 4.06) . NOTE;- The quoted rate is deemed to inclusive of cost of metal flush boxes, modular white cover plate. (ii) MS ERW conduit shall be provided on exposed surface i.e. Trusses/ Girder etc and shall be fixed with MS Clamp / saddle in lieu of concealed PVC.

-

-

-

... More
One light point/ fan point/ exhaust fan point controlled by one way 6A modular switch with ISI Marked

1114

-

-

... More
One light point controlled by two way 6A modular switch with ISI Marked

5

-

-

... More
One socket outlet 3pin independent controlled by one way 6A modular switch with ISI Marked

6

-

-

... More
One socket outlet 3pin on same board controlled by one way 6A modular switch with ISI Marked

324

-

-

... More
All as per Sl item No. 4.01 above, but with cable 2.5 sqmm for phase and neutral & 2.5 sqmm for earth continuity complete for 6/16 Amps socket point on independent board with ISI Marked complete all as specified and directed

50

-

-

... More
S&F LED tube light fitting batten type, 20 W, 230v , efficacy 120 Lumens per watt, colour temprature 6500 K (Cool White), power factor greater than 0.90, polycarbonate body , CRI 80, IP rating IP 20,THDv within 5% and THDi (8-10%) and integrated electronic driver complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose all with ISI Marked as specified and directed. Notes :- 1.The rate of three core twisted flexible copper conductor cable of suitable size for connection is included in this item and nothing shall be paid extra on this account. 2. Warranty for replacement of each LED Light fitting shall not be less than 05 years from the date of purchase. 3. Date of Purchase shall be marked on each fixture with permanent marker for redeeming warrenty benefits.

869

-

-

... More
S&F LED lamp 12W, 230V AC, 50 Hz single phase including bakelite button with all fitting fixing accessories with ISI Marked complete all as specified and directed.

12

-

-

... More
S & F surface mounted LED downlighter 15 watt with white powder coated aluminium housing with integrated electronic driver complete all as specified and directed.

1

-

-

... More
S & F surface mounted LED downlighter 18 watt with white powder coated aluminium housing with integrated electronic driver complete all as specified and directed.

1

-

-

... More
S&F Single pole and neutral sheet metal enclosure MCB DB 6 way double door for MCB’s, Phosphatised Powder coated with Bus Bar 200 amp rated, 240 volt AC complete concealed in wall all as specified and directed

1

-

-

... More
S&F MCB Single Pole 63 Amps, 240 Volts, 10 KA, 'C' Curve with ISI marked complete all as specified and directed.

2

-

-

... More
S&F MCB Single Pole and Neutral 6-32 Amps, 240 Volts, 10 KA, 'C' Curve with ISI marked complete all as specified and directed.

34

-

-

... More
S & F RJ telephonic socket with shutter, 1 module including cover plate, metal flush box (16 Guage) concealed in wall/roof complete all as specified and directed.

4

-

-

... More
EXTERNAL WATER SUPPLY WORKS NOTE:- For items of EXTERNAL WATER SUPPLY WORKS notes given at the beginning of Sch ‘A’ Part-IV (EXTERNAL WATER SUPPLY WORKS) shall also be applicable.

-

-

-

... More
M&L for cutting upto 250mm cast iron pipes and reducing reducing to required length for making branch connection complete all as specified and directed

1

-

-

... More
M&L for run lead joints for cast iron spigot and socket pipe including testing for 250mm bore pipe complete all as specified and directed

4

-

-

... More
M&L for ductile iron pipe100 mm (4”) dia, S/S including specials, Class “K-9”, ISI marked inclusive of all required fittings complete all as specified and directed .

1695

-

-

... More
Supply and fixing Cast Iron sluice valve of size 100 mm dia bore, having pressure rating PN 1.0, flanged with jointing material i.e. new rubber gasket, nuts & bolts, washer etc of suitable size and taking down old unserviceable sluice valve with ISI Marked complete all as specified and directed. Note : Material will be accepted and allowed to incorporate in the work only after production of proper purchase voucher from authorised dealer and test certificate from the manufacture.

5

-

-

... More
Supply and fixing Cast Iron sluice valve of size 250 mm dia bore, having pressure rating PN 1.0, flanged with jointing material i.e. new rubber gasket, nuts & bolts, washer etc of suitable size and taking down old unserviceable sluice valve with ISI Marked complete all as specified and directed. Note : Material will be accepted and allowed to incorporate in the work only after production of proper purchase voucher from authorised dealer and test certificate from the manufacture.

1

-

-

... More
Construction of stone masonry valve pit for Sluice valve all as specified and as per directed by Engr-in-Charge including plastering, PCC in foundation, Excavation and earth work in any type of soil, MS sheet cover 3mm thick sheet with locking arrangement painted with two coat of anti corossive paint over one coats of red oxide primer of size 1200x1200x1200mm (type 'B') as shown in Drg complete all as specified and directed .

1

-

-

... More
Construction of stone masonry valve pit for Sluice valve all as specified and as per directed by Engr-in-Charge including plastering, PCC in foundation, Excavation and earth work in any type of soil, MS sheet cover 3mm thick sheet with locking arrangement painted with two coat of anti corossive paint over one coats of red oxide primer of size 900x900x900mm (type 'B') as shown in Drg complete all as specified and directed .

5

-

-

... More
Construction of stone masonry valve pit for Sluice valve all as specified and as per directed by Engr-in-Charge including plastering, PCC in foundation, Excavation and earth work in any type of soil, MS sheet cover 3mm thick sheet with locking arrangement painted with two coat of anti corossive paint over one coats of red oxide primer of size 600x600x600mm (type 'B') as shown in Drg complete all as specified and directed .

5

-

-

... More
EXTERNAL ELETRIC SUPPLY AND DG SET WORKS NOTE:- For items of EXTERNAL ELECTRIC SUPPLY notes given at the beginning of Sch ‘A’ Part-V (EXTERNAL ELETRIC SUPPLY) shall also be applicable.

-

-

-

... More
Supply, laying, testing and commisioning in replacement of HT underground cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire aromoured electric power cables (heavy duty) with aluminium stranded condutor served with an inner sheathing of PVC tape armoured with galvanized steel strip and overall PVC sheathed 33000 volts grade (earthed) of cross sectional area of size 120 sq mm 3 core complete all as specified and directted by the Engineer-in-Charge.

460

-

-

... More
Supply and fix cable jointing kit for 33 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 Sqmm all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
S & F gang operated air break switch as per IEC 62271-103 amended upto date, rocking/ tilting type with Do fuse assembly , suitable for both horizontal and vertical mounting, three pole mounted on polymer HT insulator 6 nos , outdoor type, nominal system voltage 33 kV, rated voltage 36 kV, rated frequency 50 Hz, continuous current rating 200 Amps, rated short time withstand current for three seconds 20 kA, rated peak withstand current for three seconds 50 kA, rated lightning impulse withstand voltage (i) to earth and between poles 170 kV (Peak) (ii) across the isolating distance 195 kV (Peak), power frequency withstand voltage between (i) earth & poles 70 kV (rms) (ii) across the isolating distance 80 kV (rms), minimum isolating distance in open position 520 mm, phase to phase clearance 1220 mm, minimum cross sectional area of fixed contact 300 sqmm, minimum cross sectional area of moving contact 250 sqmm, copper connector having minimum cross sectional area of 250 sqm, maximum current density of 1.6 Amps/ sqmm for all current carrying parts, single number of brake per phase, medium grade galvanised iron pipe of 32 mm nominal bore and 5 to 6 metre length in single piece for operating pipe, pad-locking in both ‘on’ and ‘off’ position with indicators, electroplated nonferrous parts, hot dip galvanised ferrous parts, 3 Nos polymer post insulator per phase as per IEC 61109 amended upto date having rated voltage 36 kV, minimum creepage distance 900 mm, impulse withstand voltage 170 kV, wet power frequency withstand voltage 75 kV, dry wet power frequency withstand voltage 75 kV incl electrical connections, jumpering by ACSR conductor and connectors complete all as specified and as directed.

1

-

-

... More
Supply and fix of pole mounted junction box three phase with in side dimensions not less than 250 x 200 x 105 mm with porcelain connector 2 Nos, colour coded aluminium bus bar 04 Nos of rating 63 amps each mounted on non cracking epoxy insulators, MCB SP 6 Amps, 250 volts, 'C' curve - 01 Nos. Mounted in including provisioning of mounting arrangements with clamps, nut, bolts, and washer etc for fixing to pole, drilling with proper hole for incoming and outgoing cables connection of suitable size with bus bar complete all as specified and directed. complete all as specified and directed. Note : The rate quoted inculdes cost of MS Clamps, bolts, nuts and washers

46

-

-

... More
Supply & fixing in testing and commissioning of CPRI approved Factory made; outdoor type LT panel board with Aluminium busbar of capacity not less than 1.5 times of incommer, platform mounted, cubical appropriate size, self supported, front & rear openable, double door, hinged type with locking arrangement & sloping top canopy, suitable ventilation on both side, with wire mesh, IP-66 with Dust & Vermin proof, fabricated out of 3.15 mm CRCA sheet duly powder coated with 7 Tank chemical process, size of the panel should be accommodated the following accesories mention below, mounted/fixed on MS Angle iron stand /frame 35cm height from FFL. Fabricated out of 45 x 45 x 5 mm thick MS Angle duly painted with black enamel synthetic paint over coat of red oxide zink chrome primer, duly grouted in PCC 1:2:4 type B1 using 20 mm graded stone aggregate in foundation, control wiring copper stranded PVC insulated FRLS cable connected from main bus bar, earth bus strip of 32 x 6 mm size for entire length of panel, suitable size of MS Gland with gland plates and aluminum lugs/thimbles for all incoming and outgoing cables complete all as specified and directed with & including accomodating the following for Panel :- Main Panel a) copper bus bar capacity 800 Amps for Phase-R-Y-B-3 Nos & 400 Amps for neutral -1 No b) MCCB TPN 35 KA 400 Amps - 1 No c) MCCB TPN 25 KA 160 Amps - 2 Nos d MCCB TPN 250 Amps 25 KA - 1 No e) MCCB TPN 63Amps 25 KA - 1 No f) MCB SPN 32 Amps 10 KA-5 Nos g) Timer with synchronous timer 0-24 Hrs suitable for street light control and with suitable ML 3 contactor 1 Ph phase 40 Amps capacity - 01 Set. Notes: 1.The LT Panel shall be brought from OEM/authorized dealer, CPRI approved factory from the attached list of make. The necessary certification shall be furnished by the contractor.The constructional drawing make of switchgear and hardware, size of panel board technical specification shall be submitted by the contractor for approval of Accepting Officer. 2.Contractor shall arrange inspection of all panel at factory premises before dispatch .The inspection shall be carried out by the nominated representative of Accepting officer. 3 The minimum clearance of 10 cm between bus bar to bus bar & 20 cm between bus bar to earth/ body shall be maintained. 4. Any civil work involved in installation of panel shall be deemed to be included in the quoted unit rate.

1

-

-

... More
All as per item No-6.05 above but Digital Ameter of 0-500A & consisting of followings :- (FP-1) a) Copper bus bar capacity 400 Amps for Phase-R-Y-B-3 Nos & 200 Amps for neutral -1 No b) MCCB TPN 160 Amps 25 KA - 1 Nos (I/C) c) MCCB TPN 100 Amps 25KA - 1 No d) MCB SPN 6-32 Amps 10 KA - 7 Nos e) Timer with synchronous timer 0-24 Hrs suitable for street light control and with suitable ML 3 contactor 1 Ph phase 40 Amps capacity - 01 Set

1

-

-

... More
All as per item No-6.05 above but Digital Ameter of 0-500A & consisting of followings :- (FP-2) a) Copper bus bar capacity 600 Amps for Phase-R-Y-B-3 Nos & 400 Amps for neutral -1 No b) MCCB TPN 250 Amps 35 KA - 01 No (I/C) c) MCCB TPN 32 Amps 25 KA-01 No d) MCCB TPN 125 Amp 25 KA-01 No e) MCCB TPN 63 AMp 25 KA-01 No f) MCCB TPN 100 Amps 25 KA - 01 No g) MCB SPN 6-32 Amps 10 KA -07 Nos h) Timer with synchronous timer 0-24 Hrs suitable for street light control and with suitable ML 3 contactor 1 Ph phase 40 Amps capacity - 01 Set

1

-

-

... More
Supply of galvanized steel High Mast lighting system of 16m height with its accessories. Mast shaft shall be in two sections, hot dip galvanized and suitable for wind velocity as per IS 875 part 3. it shall also include accessories for high mast including head frame, stainless steel wire rope of 316 grade (97/19 construction) double drum winch, galvanized lantern carriage symmetrical arrangement suitable for luminaires & its control gear boxes and lightening protection finial. The mast shall have an integral power tool installed inside the base compartment for its operation and suitable for 08 lumanaries. High mast shall have top 150mm dia, bottom 410mm dia, sheet thickness 3mm at top & 4mm at bottom and base plate thickness min 25 mm and including the following: (i) Supply of foundation bolts manufactured from spacial steel and hot dip galvanised along with nuts, washers, anchor plates and templates. ( min 8 nos all as per OEM specifications). (ii) Supply of control panel housing suitable control circuit for the operation of high mast. It shall also consist of suitable control for the power tool motor with timer/contactor facility. (iii) Supply of LED type aviation obstruction light fitting 10W. (iv) Construction of suitable shallow foundation with M20 grade concrete for high mast considering the safe bearing capacity of soil as 10T/Sqm at 2 m depth with all material and labour. (v) Erection of high mast with suitabe equipment and wiring of luminaries with all wiring material and labour. (vi) Installation of control panel on suitable foundation including all material and labour. (vii) Automatic timer panel for switch 'ON'/'OFF' of high mast shall be provided and timer shall be astro type. (viii) Testing and commissioning of High mast system. NOTE: (i) Earthing of high mast shall be measured and paid separately. (ii) Supply of flood light luminaries shall be measured and paid separately.

1

-

-

... More
Supply and fix 1x10 watt LED Inverted pyramid tripod type LED bollard with soft 360 Degree light ( for garden light) make ; CG, model No- LBLS1-10-CDL LBLS1-10-CDL

10

-

-

... More
Shifting of transformer 315 KVA From MES Store Yard to 4021 Fd Hosp including installation and testing of inclusive of electric connection after taking shutdown with all electric safety precautions all as specified and directed by Engr-in-Charge.

1

-

-

... More
Construction of platform for transformer having dimension (2900 mm x 3050 mm), height 1250mm and foundation depth of 1200 mm including necessary earthwork in any type of soil, 150 mm moorum filling in foundation, 150 mm PCC foundation with M7.5 (Nominal Mix) using 40mm nominal size graded crushed stone aggregate, bricks work with sub class 'B' bricks, non-modular sizes as per IS-1077:1992, straight or curved on plan exceeding 6 , mean radius built in cement mortar 1:6 cement plaster 20mm thick externally in two coats of (15mm and 5mm) in cement mortar 1:4, enclosed space filled with moorum, 75mm PCC subbase of flooring with M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate,150mm PCC flooring with M10 (Nominal Mix) using 20mm nominal size graded crushed stone aggregate, finishing exposed faces of concrete surfaces and plaster surface and plaster surface with three coats of white wash all as specified and as directed.

1

-

-

... More
M&L for precast cable route Indicator made out of cement concrete 1:2:4, type B1, using (20mm graded stone aggregate) having 10cm square shape at top and 20cm square shape at bottom and total height of 90cm casted as per direction of Engineer-in-Charge and grouted into PCC 1:2:4, type B-1, 35cm below ground level as per site requirement including embossed with "HT 33000 V Cable" and also painting in synthetic enamel Paint and necessary excavation and earth work in any type of soil as directed by Engineer-in-Charge.

200

-

-

... More
SEWAGE DISPOSAL WORKS NOTE:- For items of SEWAGE DISPOSAL WORKS notes given at the beginning of SCHEDULE 'A' PART -VIII (SEWAGE DISPOSAL WORKS) shall also be applicable.

-

-

-

... More
M&L for DWCPE(SN8) 180mm(OD) /163 (ID) mm bore of pipe laid and jointed on concrete bed 150mm thick , complete including testing etc. all as specified. (Concrete bed shall be measured and paid for separately).

580

-

-

... More
M&L for DWCPE(SN8) 200mm(OD) /163 (ID) mm bore of pipe laid and jointed on concrete bed 150mm thick , complete including testing etc. all as specified. (Concrete bed shall be measured and paid for separately).

210

-

-

... More
Construction of Septic Tank with provn of excavation, in any type of soil, foundation in PCC 1:4:8, walls of fly ash brick masonry with top cover of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M30 SFRC cover, interconnecting pipes of RCI for 100 Users complete as per TD drawing (CEBZ/TD/76/2011 Sheet No 1/2 to 2/2) complete all as spd

1

-

-

... More
Construction of Septic Tank with provn of excavation, in any type of soil, foundation in PCC 1:4:8, walls of fly ash brick masonry with top cover of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M30 SFRC cover, interconnecting pipes of RCI for 150 Users complete as per TD drawing (CEBZ/TD/76/2011 Sheet No 1/2 to 2/2) complete all as spd

1

-

-

... More
Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of of size 3.0m Dia and 4.5m Depth as per TD drawing (CEBZ/TD/78/2011 Sheet No 1/2 to 2/2) complete all as spd

1

-

-

... More
Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of of size 3.6m Dia and 4.5m Depth for 150 Users as per TD drawing (CEBZ/TD/78/2011 Sheet No 1/2 to 2/2) complete all as spd

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.