Military Engineer Services Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Electrical Cables And Wires
Eprocure
Opening Date30 Nov 2024
Closing Date28 Dec 2024
Tender Amount₹ 14,52,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling of ACSR or AAC Conductor etc complete all as specified and directed.

142.62

-

-

... More
Dismantling of Stay Assembly of any type, any size etc complete all as specified and directed.

117

-

-

... More
Dismantling of UG Cable with GI Pipe of any type, any size etc (where ever existing) complete all as specified and directed.

1866

-

-

... More
Dismantling of Earthing of any type, any size etc complete all as specified and directed.

14

-

-

... More
Removing & Shifting of Existing LT Panel of any size and any type from the site and deposited at AGE E/M SI Line yard complete all as specified and directed.

3

-

-

... More
Dismantling of RCC Pole of any size etc complete all as specified and directed.

28

-

-

... More
Dismantling of stone slabs of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed.

175.48

-

-

... More
Demolition of Reinforced Concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.

48.49

-

-

... More
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar for 450mm internal dia. pipe complete all as specified and directed.

6

-

-

... More
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar for 200mm internal dia. pipe complete all as specified and directed.

303

-

-

... More
Demolition of cement concrete un reinforced in ground floors and paving n exc 15cm thickness below or above GL complete all as specified and directed.

10

-

-

... More
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. complete all as specified and directed.

111.51

-

-

... More
Demolition of cement concrete reinforced in ground floors and paving n exc 15cm thickness below or above GL complete all as specified and directed.

2

-

-

... More
Dismantling of fencing wire mesh, any type complete all as specified and directed.

553.5

-

-

... More
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed.

324

-

-

... More
Taking down, Shifting, Reinstallation, testing & commissioning of transformer to the new location as directed by Engr-in-charge for Rationalization of electric load as per requirement on ground complete all as specified and directed.

5

-

-

... More
Taking down, Shifting & Reinstallation of LT Panel to the new location as directed by Engr-in-charge for Rationalization of electric load as per requirement on ground complete all as specified and directed.

8

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2.0 core complete all as specified and directed.

15360

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4.0 core complete all as specified and directed.

48775

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4.0 core complete all as specified and directed.

9420

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4.0 core complete all as specified and directed.

6405

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed.

6205

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed.

1000

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed.

1670

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed.

1380

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed.

1090

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core complete all as specified and directed.

2030

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core complete all as specified and directed.

1360

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core complete all as specified and directed.

960

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core complete all as specified and directed.

16655

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sq mm 3.5 core complete all as specified and directed.

3205

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 630 sq mm 3.5 core complete all as specified and directed.

1600

-

-

... More
Supply & fixing in testing and commissioning of CPRI approved Factory made; outdoor type LT panel board with Aluminium busbar of capacity not less than 1.5 times of incommer, platform mounted, cubical appropriate size, self supported, front & rear openable, double door, hinged type with locking arrangement & sloping top canopy, suitable ventilation on both side, with wire mesh, IP-66 with Dust & Vermin proof, fabricated out of 3.15 mm CRCA sheet duly powder coated with 7 Tank chemical process with colour shade RAL 7035 Siemens grey pure polyester, size of the panel should be accommodated the following accesories mention below, mounted/fixed on MS Angle iron stand /frame 35cm height from FFL. Fabricated out of 45 x 45 x 5 mm thick MS Angle ISMC duly painted with two coat of black enamel synthetic paint over coat of red oxide zink chrome primer, duly grouted in PCC 1:2:4 type B1 using 20 mm graded stone aggregate in foundation, control wiring copper stranded PVC insulated FRLS cable connected from main bus bar, earth bus strip of 32 x 6 mm size for entire length of panel, suitable size of MS Gland with gland plates and aluminum lugs/thimbles for all incoming and outgoing cables including 1.6 mm thick Danger notice plate complete all as specified and directed with & including accomodating the following accessories & switchgears for Panel :-Loc :- T - 1/1. Family Qtr transformer area (Near P-95)

1

-

-

... More
Incomer:- (i) MCCB, 4 pole, 200 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 25A, 10 kA at 415 volts - 14 No, (ii) MCB, SPN 10 A, 10 kA at 415 volts - 1 No Notes: 1.The LT Panel shall be brought from OEM/authorized dealer, CPRI approved factory from the attached list of make. The necessary certification shall be furnished by the contractor.The constructional drawing make of switchgear and hardware, size of panel board technical specification shall be submitted by the contractor for approval of GE. 2.Contractor shall arrange inspection of all panel at factory premises before dispatch .The inspection shall be carried out by the nominated representative of Accepting officer. 3 The minimum clearance of 10 cm between bus bar to bus bar & 20 cm between bus bar to earth/ body shall be maintained. 4. Any civil work involved in installation of panel shall be deemed to be included in the quoted unit rate.

-

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- Loc :- T - 1/2. Family Qtr transformer area (Near P-104) Incomer:- (i) MCCB, 4 pole, 200 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 25 A, 10 kA at 415 volt - 16 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- Loc :- 1. T-1/3. Family Qtr transformer area (Near P-111). 2. T-1/4. Family Qtr transformer area (Near P-118). 3. T-1/6. Family Qtr transformer area (Near P-131). 4. T-1/8. Family Qtr transformer area ( Near P-350). 5. T-4/4. Hav Qtr transformer area (Near P-90). Incomer:- (i) MCCB, 4 pole, 200 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 25 A, 10 kA at 415 volt - 14 No.

5

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- 1. T-1/5. Family Qtr transformer area (Near P-124). 2. T-3/1. SF Qtr transformer area (Near P-441) Incomer:- (i) MCCB, 4 pole, 200 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 25 A, 10 kA at 415 volt - 12 No.

2

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- 1. T-1/9. Family Qtr transformer area (Near T-176). 2. T-5/1. Kala Talab transformer area (Near T-60A) Incomer:- (i) MCCB, 4 pole, 63 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 9 No.

2

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-2/1. JCO Qtr transformer area (Near P-408) Incomer:- (i) MCCB, 4 pole, 125 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 25 A, 10 kA at 415 volts- 6 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-2/2. JCO Qtr transformer area (Near P-349) Incomer:- (i) MCCB, 4 pole, 160 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 25 A, 10 kA at 415 volt - 11 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-2/3. JCO Qtr transformer area (Near P-151) Incomer:- (i) MCCB, 4 pole, 100 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 25 A, 10 kA at 415 volt - 5 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-2/4. JCO Qtr transformer area (Near P-346) Incomer:- (i) MCCB, 4 pole, 63 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 25 A, 10 kA at 415 volt - 4 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-2/5. JCO Qtr transformer area (Near T-154) Incomer:- (i) MCCB, 4 pole, 63 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 5 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 4 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-3/2. SF Qtr transformer area (Near P-423) Incomer:- (i) MCCB, 4 pole, 125 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 25 A, 10 kA at 415 volt - 7 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-3/3. SF Qtr transformer area (Near P-355) Incomer:- (i) MCCB, 4 pole, 250 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=35 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 25 A, 10 kA at 415 volt - 16 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :-1. T-4/2. Hav Qtr transformer area (Near P-78), 2. T-4/3. SF Qtr transformer area (Near P-85) Incomer:- (i) MCCB, 4 pole, 160 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 25 A, 10 kA at 415 volt - 10 No.

2

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-5/2. Kala Talab transformer area (Near T-63) Incomer:- (i) MCCB, 4 pole, 63 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 40 A, 10 kA at 415 volt - 1 No, (ii) MCB, TPN 16 A, 10 kA at 415 volt - 3 No, (iii) MCB, TPN 25 A, 10 kA at 415 volt - 1 No, (iv) 4 Pole Power Contactor 12 A - 01 No, (v) Electronic Timer 3 Phase - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-5/3. Kala Talab transformer area (Near P-37) Incomer:- (i) MCCB, 4 pole, 160 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 25 A, 10 kA at 415 volt - 10 No, (ii) MCB, TPN 16 A, 10 kA at 415 volt - 6 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-5/4. Kala Talab transformer area (Near T-74) Incomer:- (i) MCCB, 4 pole, 32 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 25 A, 10 kA at 415 volt - 1 No, (ii) MCB, TPN 16 A, 10 kA at 415 volt - 1 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-5/5. Kala Talab transformer area (Near T-79) Incomer:- (i) MCCB, 4 pole, 32 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 6 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :-1. T-5/6. Kala Talab transformer area (Near T-319A). 2. T-5/8. Kala Talab transformer area (Near T-324). Incomer:- (i) MCCB, 4 pole, 40 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 7 No,

2

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-5/7. Kala Talab transformer area (Near T-306A) Incomer:- (i) MCCB, 4 pole, 40 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 8 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-5/9. Kala Talab transformer area (Near T-102) Incomer:- (i) MCCB, 4 pole, 40 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 5 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 4 No

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-6/1. New Sanchi transformer area (Near T-290) Incomer:- (i) MCCB, 4 pole, 250 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=35 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 63 A, 10 kA at 415 volt - 6 No, (ii) MCB, TPN 32 A, 10 kA at 415 volt - 1 No (iii) MCB, TPN 20 A, 10 kA at 415 volt - 1 No (iv) MCB, TPN 25 A, 10 kA at 415 volt - 1 No, (v) 4 Pole Power Contactor 12 A - 01 No, (vi) Electronic Timer 3 Phase - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-7/1. Offrs Mess transformer area (Near P-3) Incomer:- (i) MCCB, 4 pole, 160 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 63 A, 10 kA at 415 volt - 2 No, (ii) MCB, TPN 32 A, 10 kA at 415 volt - 1 No (iii) MCB, TPN 20 A, 10 kA at 415 volt - 3 No (iv) MCB, TPN 25 A, 10 kA at 415 volt - 1 No, (v) 4 Pole Power Contactor 12 A - 01 No, (vi) Electronic Timer 3 Phase - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-8/1. CHQ transformer area (Near P-44) Incomer:- (i) MCCB, 4 pole, 160 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 40 A, 10 kA at 415 volt - 4 No, (ii) MCB, TPN 16 A, 10 kA at 415 volt - 10 No

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-8/2. CHQ transformer area (Near P-43) Incomer:- (i) MCCB, 4 pole, 32 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 20 A, 16 kA at 415 volt - 1 No, (ii) MCB, SPN 10 A, 16 kA at 415 volt - 5 No (iii) MCB, TPN 25 A, 10 kA at 415 volt - 1 No, (iv) 4 Pole Power Contactor 12 A - 01 No, (v) Electronic Timer 3 Phase - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-8/3. CHQ transformer area (Near T-172) Incomer:- (i) MCCB, 4 pole, 32 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 3 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-8/4. CHQ transformer area (Near T-176) Incomer:- (i) MCCB, 4 pole, 32 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 20 A, 10 kA at 415 volt - 1 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 4 No

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-8/6. CHQ transformer area (Near T-186) Incomer:- (i) MCCB, 4 pole, 63 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 7 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-8/7. CHQ transformer area (Near T-321) Incomer:- (i) MCCB, 4 pole, 40 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 6 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 5 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-8/8. CHQ transformer area (Near T-324) Incomer:- (i) MCCB, 4 pole, 40 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 8 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 3 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-8/9. CHQ transformer area (Near T-176) Incomer:- (i) MCCB, 4 pole, 40 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 9 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-8/10. CHQ transformer area (Near T-134) Incomer:- (i) MCCB, 4 pole, 32 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 4 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 5 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-9/1. 3 TB RO transformer area (Near P-590) Incomer:- (i) MCCB, 4 pole, 100 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 20 A, 10 kA at 415 volt - 5 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 1 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-9/2. 3 TB RO transformer area (Near P-564) Incomer:- (i) MCCB, 4 pole, 100 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 20 A, 10 kA at 415 volt - 5 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 2 No, (iii) MCB, TPN 25 A, 10 kA at 415 volt - 1 No, (iv) 4 Pole Power Contactor 12 A - 01 No, (v) Electronic Timer 3 Phase - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-9/3. 3 TB RO transformer area (Near T-569) Incomer:- (i) MCCB, 4 pole, 63 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 9 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt- 2 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-9/4. 3 TB RO transformer area (Near T-214) Incomer:- (i) MCCB, 4 pole, 32 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 3 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 7 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-9/5. 3 TB RO transformer area (Near T-387) Incomer:- (i) MCCB, 4 pole, 32 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 7 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 1 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-9/6. 3 TB RO transformer area (Near T-239) Incomer:- (i) MCCB, 4 pole, 100 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 40 A, 10 kA at 415 volt - 2 No, (ii) MCB, TPN 16 A, 10 kA at 415 volt - 2 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-10/1. 3 TB OR Mess transformer area (Near P-466) Incomer:- (i) MCCB, 4 pole, 160 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 20 A, 10 kA at 415 volt - 10 No, (ii) MCB, TPN 25 A, 10 kA at 415 volt - 1 No, (iii) 4 Pole Power Contactor 12 A - 01 No, (iv) Electronic Timer 3 Phase - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-10/2. 3 TB OR Mess transformer area (Near P-474) Incomer:- (i) MCCB, 4 pole, 160 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 20 A, 10 kA at 415 volt - 11 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-11/1. 1 TB transformer area (Near T-344) Incomer:- (i) MCCB, 4 pole, 32 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt- 3 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 2 No, (iii) MCB, TPN 25 A, 10 kA at 415 volt - 1 No, (iv) 4 Pole Power Contactor 12 A - 01 No, (v) Electronic Timer 3 Phase - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-11/2. 1 TB transformer area (Near P-52) Incomer:- (i) MCCB, 4 pole, 32 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 4 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt- 4 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-11/3. 1 TB transformer area (Near T-408) Incomer:- (i) MCCB, 4 pole, 32 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, SPN 10 A, 10 kA at 415 volt - 4 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-12/1. 21 CGSR(A) transformer area (Near P-749) Incomer:- (i) MCCB, 4 pole, 63 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 20 A, 10 kA at 415 volt - 2 No, (ii) MCB, TPN 16 A, 10 kA at 415 volt - 4 No, (iii) MCB, TPN 25 A, 10 kA at 415 volt - 1 No, (iv) 4 Pole Power Contactor 12 A - 01 No, (v) Electronic Timer 3 Phase - 01 No.

2

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-12/2. 21 CGSR(A) transformer area (Near P-716) Incomer:- (i) MCCB, 4 pole, 63 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 50 A, 10 kA at 415 volt - 1 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 8 No,

2

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-12/3. 21 CGSR(A) transformer area (Near P-710) Incomer:- (i) MCCB, 4 pole, 63 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 40 A, 10 kA at 415 volt - 1 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 4 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-13/1. MES Colony transformer area (Near P-324) Incomer:- (i) MCCB, 4 pole, 125 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 20 A, 10 kA at 415 volt - 7 No, (ii) MCB, TPN 16 A, 10 kA at 415 volt - 1 No, (iii) MCB, TPN 25 A, 10 kA at 415 volt - 1 No, (iv) 4 Pole Power Contactor 12 A - 01 No, (v) Electronic Timer 3 Phase - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-13/2. MES Colony transformer area (Near T-31) Incomer:- (i) MCCB, 4 pole, 63 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 20 A, 10 kA at 415 volt - 1 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 15 No, (iii) MCB, TPN 25 A, 10 kA at 415 volt - 1 No, (iv) 4 Pole Power Contactor 12 A - 01 No, (v) Electronic Timer 3 Phase - 01 No.

3

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-13/3. MES Colony transformer area (Near T-31) Incomer:- (i) MCCB, 4 pole, 63 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 20 A, 10 kA at 415 volt - 3 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 13 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-14/2. Camp Area transformer area (Near P-740) Incomer:- (i) MCCB, 4 pole, 32 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 1 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 3 No, (iii) MCB, TPN 25 A, 10 kA at 415 volt - 1 No, (iv) 4 Pole Power Contactor 12 A - 01 No, (v) Electronic Timer 3 Phase - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- 1. T-15/1. 102 Engr Regt transformer area (Near P-453A). 2. T-15/2. 102 Engr Regt transformer area (Near P-535) Incomer:- (i) MCCB, 4 pole, 32 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, SPN 10 A, 10 kA at 415 volt - 7 No,

2

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-15/3. 102 Engr Regt transformer area (Near P-533) Incomer:- (i) MCCB, 4 pole, 32 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 3 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 5 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-15/4. 102 Engr Regt transformer area (Near P-511) Incomer:- (i) MCCB, 4 pole, 32 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 5 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 5 No, (iii) MCB, TPN 25 A, 10 kA at 415 volt - 1 No, (iv) 4 Pole Power Contactor 12 A - 01 No, (v) Electronic Timer 3 Phase - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-15/5.102 Engr Regt transformer area (Near P-451) Incomer:- (i) MCCB, 4 pole, 100 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 12 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 1 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-15/6.102 Engr Regt transformer area (Near P-456) Incomer:- (i) MCCB, 4 pole, 32 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 2 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 3 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-14/1. Camp Area transformer area (Near T-555) Incomer:- (i) MCCB, 4 pole, 32 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 3 No,

2

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-15/8. 102 Engr Regt transformer area (Near P-395) Incomer:- (i) MCCB, 4 pole, 32 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 16 A, 10 kA at 415 volt - 4 No, (ii) MCB, SPN 10 A, 10 kA at 415 volt - 1 No

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-01/M (Main panel near family qtr transformer). Incomer:- (i) MCCB, 3 pole, 1250 A, 415 Volts with adjustable thermal & adjustable magnetic release type & braking capacity of Icu=Ics=50 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCCB, 4 pole, 200 A, 25 kA at 415 volt - 8 No, (ii) MCCB, 4 pole, 63 A, 25 kA at 415 volt - 1 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-05/M (Main panel near Kala talab transformer). Incomer:- (i) MCCB, 4 pole, 400 A, 415 Volts with adjustable thermal & adjustable magnetic release type & braking capacity of Icu=Ics=35 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCCB, 4 pole, 160 A, 25 kA at 415 volt - 1 No, (ii) MCCB, 4 pole, 100 A, 25 kA at 415 volt - 1 No, (iii) MCCB, 4 pole, 63 A, 25 kA at 415 volt - 2 No, (iv) MCCB, 4 pole, 40 A, 25 kA at 415 volt - 2 No, (v) MCCB, 4 pole, 32 A, 25 kA at 415 volt - 4 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-08/M (Main panel near CHQ transformer) Incomer:- (i) MCCB, 4 pole, 400 A, 415 Volts with adjustable thermal & adjustable magnetic release type & braking capacity of Icu=Ics=35 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCCB, 4 pole, 160 A, 25 kA at 415 volt - 1 No, (ii) MCCB, 4 pole, 63 A, 25 kA at 415 volt - 1 No (iii) MCCB, 4 pole, 40 A, 25 kA at 415 volt - 3 No, (iv) MCCB, 4 pole, 32 A, 25 kA at 415 volt - 5 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-09/M (Main panel near 3 TB RO transformer) Incomer:- (i) MCCB, 4 pole, 400 A, 415 Volts with adjustable thermal & adjustable magnetic release type & braking capacity of Icu=Ics=35 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCCB, 4 pole, 100 A, 25 kA at 415 volt - 4 No, (ii) MCCB, 4 pole, 40 A, 25 kA at 415 volt - 1 No, (iii) MCCB, 4 pole, 32 A, 25 kA at 415 volt - 2 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- T-15/M (Main panel near 102 Engr Regt transformer) Incomer:- (i) MCCB, 4 pole, 250 A, 415 Volts with adjustable thermal & adjustable magnetic release type & braking capacity of Icu=Ics=35 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCCB, 4 pole, 125 A, 25 kA at 415 volt - 1 No, (ii) MCCB, 4 pole, 32 A, 25 kA at 415 volt - 7 No,

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- 1.T-1/7 - Family Qtr transformer (Near P-7) , 2. T-4/1 - Hav Qtr transformer (Near P-73) Incomer:- (i) MCCB, 4 pole, 200 A, 415 Volts with thermal magnetic release type & braking capacity of Icu=Ics=25 KA - 1 No, (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , Out going:- (i) MCB, TPN 25 A, 10 kA at 415 volt - 15 No, (ii) 4 Pole Power Contactor 12 A - 01 No, (iii) Electronic Timer 3 Phase - 01 No.

2

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel :- (P-Qtr Panel No - 1,2,3) (a) MCCB TPN 125 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 04 Nos (O/G) (c) MCB SPN 63 Amps, 10 KA at 230 Volts - 02 (O/G) (d) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (e) Phase indicating lamp RYB neon type (Set of three ) -01 Set (f) VAF+PF Meters , Accuracy class 0.5 - 01 No

3

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (P-Qtr Panel No - 4) (a) MCCB TPN 200 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 06 Nos (O/G) (c) MCB SPN 63 Amps, 10 KA at 230 Volts - 02 (O/G) (d) Phase indicating lamp RYB neon type (Set of three ) -01 Set (e) VAF+PF Meters , Accuracy class 0.5 - 01 No

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (7 Garh Panel No - 1,2,3) (a) MCCB TPN 100 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 06 Nos (O/G) (c) MCB SPN 63 Amps, 10 KA at 230 Volts - 04 (O/G) (d) Phase indicating lamp RYB neon type (Set of three ) - 01 Set (e) VAF+PF Meters , Accuracy class 0.5 - 01 No.

3

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (7 Garh Panel No - 4) (a) MCCB TPN 125 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 10 Nos (O/G) (c) MCB SPN 40 Amps, 10 KA at 230 Volts - 04 (O/G) (d) Phase indicating lamp RYB neon type (Set of three ) -01 Set (e) VAF+PF Meters , Accuracy class 0.5 - 01 No.

1

-

-

... More
Ditto- all as per Item No. 99 here-in-before all as specified & directed. (7 Garh Panel No - 5) (a) MCCB TPN 100 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 40 Amps, 16 KA at 415 Volts - 04 Nos (O/G) (c) MCB SPN 40 Amps, 10 KA at 230 Volts - 03 (O/G) (d) Phase indicating lamp RYB neon type (Set of three ) -01 Set (e) VAF+PF Meters , Accuracy class 0.5 - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (7 Garh Panel No - 6) (a) MCCB TPN 160 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 100 Amps, 16 KA at 415 Volts - 01 Nos (O/G) (c) MCCB TPN 63 Amps, 16 KA at 415 Volts - 06 Nos (O/G) (d) MCB SPN 40 Amps, 10 KA at 230 Volts - 04 (O/G) (e) Phase indicating lamp RYB neon type (Set of three ) -01 Set (f) VAF+PF Meters , Accuracy class 0.5 - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (7 Garh Panel No - 7) (a) MCCB TPN 100 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 01 Nos (O/G) (c) MCB SPN 40 Amps, 10 KA at 230 Volts - 10 (O/G) (d) MCB TPN 63 Amps, 10 KA at 230 Volts - 03 (O/G) (e) Phase indicating lamp RYB neon type (Set of three ) -01 Set (f) VAF+PF Meters , Accuracy class 0.5 - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (7 Garh Panel No - 8) (a) MCCB TPN 160 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 100 Amps, 16 KA at 415 Volts - 01 Nos (O/G) (c) MCCB TPN 63 Amps, 16 KA at 415 Volts - 03 Nos (O/G) (d) MCB SPN 40 Amps, 10 KA at 230 Volts - 07 (O/G) (e) Phase indicating lamp RYB neon type (Set of three ) -01 Set (f) VAF+PF Meters , Accuracy class 0.5 - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (7 Garh Panel No - 9) (a) MCCB TPN 200 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 100 Amps, 16 KA at 415 Volts - 02 Nos (O/G) (c) MCCB TPN 63 Amps, 16 KA at 415 Volts - 02 Nos (O/G) (d) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (e) MCB DP 63 Amps, 10 KA at 230 Volts - 06 (O/G) (f) Phase indicating lamp RYB neon type (Set of three ) -01 Set (g) VAF+PF Meters , Accuracy class 0.5 - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (7 Garh Panel No - 10,11) (a) MCCB TPN 63 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCB TPN 63 Amps, 10 KA at 230 Volts - 03 (O/G) (c) MCB SPN 63 Amps, 10 KA at 230 Volts - 10 (O/G) (d) Phase indicating lamp RYB neon type (Set of three ) -01 Set (e) VAF+PF Meters , Accuracy class 0.5 - 01 No.

2

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (Trvedi Enclave Panel No - 1) (a) MCCB TPN 250 Amps, Icu=Ics 35 KA at adjustable type thermal magnetic based release 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 09 Nos (O/G) (c) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (d) MCB SPN 40 Amps, 10 KA at 230 Volts - 04 (O/G) (e) Phase indicating lamp RYB neon type (Set of three ) -01 Set (f) VAF+PF Meters , Accuracy class 0.5 - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (Trvedi Enclave Panel No - 2,4) (a) MCCB TPN 100 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 04 Nos (O/G) (c) MCB SPN 40 Amps, 10 KA at 230 Volts - 02 (O/G) (d) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (e) Phase indicating lamp RYB neon type (Set of three ) -01 Set (f) VAF+PF Meters , Accuracy class 0.5 - 01 No.

2

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (Trvedi Enclave Panel No - 3) (a) MCCB TPN 160 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 07 Nos (O/G) (c) MCB TPN 63 Amps, 10 KA at 230 Volts - 02 (O/G) (d) MCB SPN 40 Amps, 10 KA at 230 Volts - 02 (O/G) (e) Phase indicating lamp RYB neon type (Set of three ) -01 Set (f) VAF+PF Meters , Accuracy class 0.5 - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (Capt-Qtr Panel No - 1) (a) MCCB TPN 160 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 07 Nos (O/G) (c) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (d) MCB SPN 40 Amps, 10 KA at 230 Volts - 02 (O/G) (e) Phase indicating lamp RYB neon type (Set of three ) -01 Set (f) VAF+PF Meters , Accuracy class 0.5 - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (Capt-Qtr Panel No - 2,3,4) (a) MCCB TPN 125 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 04 Nos (O/G) (c) MCB SPN 40 Amps, 10 KA at 230 Volts - 02 (O/G) (d) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (e) Phase indicating lamp RYB neon type (Set of three ) -01 Set (f) VAF+PF Meters , Accuracy class 0.5 - 01 No.

3

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (Sultania Retreat Panel No - 1) (a) MCCB TPN 200 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 100 Amps, 16 KA at 415 Volts - 02 Nos (O/G) (c) MCCB TPN 63 Amps, 16 KA at 415 Volts - 06 Nos (O/G) (d) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (e) MCB SPN 40 Amps, 10 KA at 230 Volts - 04 (O/G) (f) Phase indicating lamp RYB neon type (Set of three ) -01 Set (g) VAF+PF Meters , Accuracy class 0.5 - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (Sultania Retreat Panel No - 2) (a) MCCB TPN 160 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 100 Amps, 16 KA at 415 Volts - 02 Nos (O/G) (c) MCCB TPN 63 Amps, 25 KA at 415 Volts - 04 Nos (O/G) (d) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (e) MCB SPN 40 Amps, 10 KA at 230 Volts - 04 (O/G) (f) Phase indicating lamp RYB neon type (Set of three ) -01 Set (g) VAF+PF Meters , Accuracy class 0.5 - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (CWE Office Panel No - 3) (a) MCCB TPN 250 Amps, Icu=Ics 35 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 100 Amps, 16 KA at 415 Volts - 02 Nos (O/G) (c) MCCB TPN 160 Amps, 25 KA at 415 Volts - 01 Nos (O/G) (d) MCCB TPN 63 Amps, 16 KA at 415 Volts - 02 (O/G) (e) MCB SPN 40 Amps, 10 KA at 230 Volts - 04 (O/G) (f) Phase indicating lamp RYB neon type (Set of three ) -01 Set (g) VAF+PF Meters , Accuracy class 0.5 - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (Library & SCC Main Panel ) (a) MCCB TPN 400 Amps, Icu=Ics 35 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 100 Amps, 16 KA at 415 Volts - 02 Nos (O/G) (c) MCCB TPN 125 Amps, 25 KA at 415 Volts - 02 Nos (O/G) (d) MCB TPN 63 Amps, 16 KA at 415 Volts - 01 (O/G) (e) MCB SPN 40 Amps, 10 KA at 230 Volts - 02 (O/G) (f) Phase indicating lamp RYB neon type (Set of three ) -01 Set (g) VAF+PF Meters , Accuracy class 0.5 - 1 No.

2

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (SCC Main Panel ) (a) MCCB TPN 400 Amps, Icu=Ics 35 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 100 Amps, 16 KA at 415 Volts - 03 Nos (O/G) (c) MCCB TPN 200 Amps, 25 KA at 415 Volts - 01 Nos (O/G) (d) MCCB TPN 63 Amps, 16 KA at 415 Volts - 01 (O/G) (e) MCB SPN 40 Amps, 10 KA at 230 Volts - 03 (O/G) (f) Phase indicating lamp RYB neon type (Set of three ) -01 Set (g) VAF+PF Meters , Accuracy class 0.5 - 1 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (Library Panel No 1 & 2 ) (a) MCCB TPN 100 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 100 Amps, 16 KA at 415 Volts - 01 Nos (O/G) (c) MCCB TPN 63 Amps, 16 KA at 415 Volts - 02 Nos (O/G) (d) MCB SPN 40 Amps, 10 KA at 230 Volts - 02 (O/G) (e) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (f) Phase indicating lamp RYB neon type (Set of three ) -01 Set (g) VAF+PF Meters , Accuracy class 0.5 - 1 No.

2

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (Library Panel No 3 ) (a) MCCB TPN 160 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 100 Amps, 16 KA at 415 Volts - 04 Nos (O/G) (c) MCB SPN 63 Amps, 10 KA at 230 Volts - 02 (O/G) (d) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (e) Phase indicating lamp RYB neon type (Set of three ) -01 Set (f) VAF+PF Meters , Accuracy class 0.5 - 1No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (SCC Camp Panel No 1 & 2 ) (a) MCCB TPN 100 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 02 Nos (O/G) (c) MCCB TPN 32 Amps, 16 KA at 415 Volts - 05 Nos (O/G) (d) MCB SPN 40 Amps, 10 KA at 230 Volts - 02 (O/G) (e) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (f) Phase indicating lamp RYB neon type (Set of three ) -01 Set (g) VAF+PF Meters , Accuracy class 0.5 - 1 No.

2

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (SCC Camp Panel No 3 & 4 ) (a) MCCB TPN 160 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 10 Nos (O/G) (c) MCCB TPN 32 Amps, 16 KA at 415 Volts - 02 Nos (O/G) (d) MCB SPN 40 Amps, 10 KA at 230 Volts - 02 (O/G) (e) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (f) Phase indicating lamp RYB neon type (Set of three ) -01 Set (g) VAF+PF Meters , Accuracy class 0.5 - 1 No.

2

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (SCC Camp Panel No 5 ) (a) MCCB TPN 100 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 01 Nos (O/G) (c) MCCB TPN 32 Amps, 16 KA at 415 Volts - 05 Nos (O/G) (d) MCB SPN 40 Amps, 10 KA at 230 Volts - 02 (O/G) (e) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (f) Phase indicating lamp RYB neon type (Set of three ) -01 Set (g) VAF+PF Meters , Accuracy class 0.5 - 1 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (SCC Office Panel No 1 ) (a) MCCB TPN 100 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 04 Nos (O/G) (c) MCCB TPN 32 Amps, 16 KA at 415 Volts - 01 Nos (O/G) (d) MCB SPN 40 Amps, 10 KA at 230 Volts - 02 (O/G) (e) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (f) Phase indicating lamp RYB neon type (Set of three ) -01 Set (g) VAF+PF Meters , Accuracy class 0.5 - 1 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (SCC Office Panel No 2 ) (a) MCCB TPN 100 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 03 Nos (O/G) (c) MCCB TPN 32 Amps, 16 KA at 415 Volts - 03 Nos (O/G) (d) MCB SPN 40 Amps, 10 KA at 230 Volts - 02 (O/G) (e) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (f) Phase indicating lamp RYB neon type (Set of three ) -01 Set (g) VAF+PF Meters , Accuracy class 0.5 - 1 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel (SCC Office Panel No 3 ) (a) MCCB TPN 200 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 160 Amps, 25 KA at 415 Volts - 01 Nos (O/G) (c) MCCB TPN 100 Amps, 16 KA at 415 Volts - 02 Nos (O/G) (d) MCCB TPN 63 Amps, 16 KA at 415 Volts - 01 Nos (O/G) (e) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (f) MCB SPN 40 Amps, 10 KA at 230 Volts - 02 (O/G) (g) Phase indicating lamp RYB neon type (Set of three ) -01 Set (h) VAF+PF Meters , Accuracy class 0.5 - 01 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel ( Offices and Misc Bldgs Panel No 1 ) (a) MCCB TPN 100 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 01 Nos (O/G) (c) MCCB TPN 32 Amps, 16 KA at 415 Volts - 04 Nos (O/G) (d) MCB SPN 40 Amps, 10 KA at 230 Volts - 02 (O/G) (e) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (f) Phase indicating lamp RYB neon type (Set of three ) -01 Set (g) VAF+PF Meters , Accuracy class 0.5 - 1 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel ( Offices and Misc Bldgs Panel No 2 ) (a) MCCB TPN 125 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 03 Nos (O/G) (c) MCCB TPN 32 Amps, 16 KA at 415 Volts - 03 Nos (O/G) (d) MCB SPN 40 Amps, 10 KA at 230 Volts - 02 (O/G) (e) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (f) Phase indicating lamp RYB neon type (Set of three ) -01 Set (g) VAF+PF Meters , Accuracy class 0.5 - 1 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel ( Offices and Misc Bldgs Panel No 3 ) (a) MCCB TPN 125 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 03 Nos (O/G) (c) MCCB TPN 32 Amps, 16 KA at 415 Volts - 03 Nos (O/G) (d) MCB SPN 40 Amps, 10 KA at 230 Volts - 07 (O/G) (e) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (f) Phase indicating lamp RYB neon type (Set of three ) -01 Set (g) VAF+PF Meters , Accuracy class 0.5 - 1 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel ( Offices and Misc Bldgs Panel No 4 ) (a) MCCB TPN 100 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 02 Nos (O/G) (c) MCCB TPN 32 Amps, 16 KA at 415 Volts - 06 Nos (O/G) (d) MCB SPN 40 Amps, 10 KA at 230 Volts - 02 (O/G) (e) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (f) Phase indicating lamp RYB neon type (Set of three ) -01 Set (g) VAF+PF Meters , Accuracy class 0.5 - 1 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel ( Stn Mandir Panel No 1 ) (a) MCCB TPN 100 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 01 Nos (O/G) (c) MCCB TPN 32 Amps, 16 KA at 415 Volts - 04 Nos (O/G) (d) MCB SPN 40 Amps, 10 KA at 230 Volts - 02 (O/G) (e) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (f) Phase indicating lamp RYB neon type (Set of three ) -01 Set (g) VAF+PF Meters , Accuracy class 0.5 - 1 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel ( P-15 OR Qtr Panel No 2 ) (a) MCCB TPN 100 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 03 Nos (O/G) (c) MCCB TPN 32 Amps, 16 KA at 415 Volts - 02 Nos (O/G) (d) MCB SPN 40 Amps, 10 KA at 230 Volts - 02 (O/G (e) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (f) Phase indicating lamp RYB neon type (Set of three ) -01 Set (g) VAF+PF Meters , Accuracy class 0.5 - 1 No.

1

-

-

... More
All as per above Item No.36.00 & 36.01 but comprising the following for Panel ( GTO Ground Panel No 3 ) (a) MCCB TPN 100 Amps, Icu=Ics 25 KA adjustable type thermal magnetic based release at 415 Volts - 01 Nos (I/C) (b) MCCB TPN 63 Amps, 16 KA at 415 Volts - 01 Nos (O/G) (c) MCCB TPN 32 Amps, 16 KA at 415 Volts - 06 Nos (O/G) (d) MCB SPN 40 Amps, 10 KA at 230 Volts - 02 (O/G) (e) MCB TPN 63 Amps, 10 KA at 230 Volts - 01 (O/G) (f) Phase indicating lamp RYB neon type (Set of three ) -01 Set (g) VAF+PF Meters , Accuracy class 0.5 - 1 No.

1

-

-

... More
M & L For sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8cm below cable & 15cm above cable) complete all as specified and directed. Note: Compacted/punned thickness shall be measured & paid.

8915.67

-

-

... More
Supplying and laying un- reinforced precast concrete cable cover, class LV, type 1, size 250mm x 150mm x 40mm for laying in trenches for cable protection laid adjacent to each other length wise perpendicular to the central axix of cable complete all as specified and directed.

733800

-

-

... More
Boring of holes under road / pavement / hard standing etc by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete all as specified & directed.

250

-

-

... More
S&F in replacement of polycarbonate thermoplastic weather proof junction boxes IP-65/66 for street lights size of approx size not less than 210 x 155 x 102 mm with metric knock outs for cable entry, weather proof for outdoor installation, glands and with 4 terminals, terminal rating 32 Amps for three phase and neutral mounted with locking arrangement including fixing to the poles by means of suitable size of clamps, nuts and bolts with and including 01 no SP, MCB, 6-32 Amps,10KA complete all as specified and directed.

715

-

-

... More
M&L for precast cable route Indicator made out of cement concrete 1:2:4, type B1, using (20mm graded stone aggregate) having 10cm square shape at top and 20cm square shape at bottom and total height of 90cm casted as per direction and grouted into PCC 1:2:4, type B-1, 35 cm below ground level as per site requirement including embossed with "LT 1100 V Cable" and also painting in synthetic enamel Paint and necessary excavation and earth work in any type of soil complete all as specified and directed.

1480

-

-

... More
M&L for earthing complete with galvanised steel earth plate 60cmx60cmx3.15 mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanised mild steel earthing lead strip 32X6mm by means of bolts nuts check-nuts and washers of galvanized iron or steel as shown in electrical plate No 3 of MES schedule Part-I connecting to earthing test point and testing on completion with including 40mm bore light grade GI protection pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work in any type of soil & disposal of soil, providing alternate layers of charcoal and common salt, construction of PCC earth chamber in 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover, reinforced with 8mm TMT bars 100mm C/C both ways with life hook made out oof 8mm dia bars, watering arrangement with funnel & wire mesh, complete all as specified and directed. Note:- (i) The concrete pit shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of GI pipe light grade for protection of earth strip and earh strip upto 7.5 M. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself

192

-

-

... More
M&L for earthing complete with galvanised steel earth plate 60cmx60cmx3.15 mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to earth lead of 4.0mm dia. galvanished mild steel wire by means of bolts nuts check-nuts and washers of galvanized iron or steel as shown in electrical plate No 3 of MES schedule Part-I connecting to earthing test point and testing on completion with including 15mm bore light grade GI protection pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work in any type of soil & disposal of soil, providing alternate layers of charcoal and common salt, construction of PCC earth chamber in 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover, reinforced with 8mm TMT bars 100mm C/C both ways with life hook made out oof 8mm dia bars, watering arrangement with funnel & wire mesh, complete all as specified and directed. Note:- (i) The concrete pit shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of GI pipe light grade for protection of earth strip and earh strip upto 7.5 M. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself

15

-

-

... More
Supply & fix in replacement, testing, commissioning of LT panel board , weather proof, outdoor type powder coated, double door shutter, made out of CRCA sheet 3.15 mm thick outer and 2.00 mm thick for inner door confirming degree of protection IP 66 to with angle iron 50x50x6 mm outoor, floor mounting type with closed Aluminium bus bar of capacity not less than 1.5 times of incommer including necessary insulator suitable for 3 phase, 4 wire 50 Hz AC, CPRI approved including provn of digital ammeter 0-350A, digital voltemeter 0-500 Volts, CT's of suitable ratio,indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 30 cm grouting etc all as specified and directed with the following Work also includes provision of suitable size of cable glands,cable lugs,nut, bolts,washers etcThe bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron ). (a) Bus bar chamber comprising 4 Nos Aluminium strip bus bars air insulated and PVC sheathed capacity of size not less than 1.5 times of incommer with colour coding in separate sheet steel chamber of panel box.

8

-

-

... More
INCOMING: (b) MCCB 415 volts, 63 amps rating TPN , adjustable type , thermal magnetic based release incoming supply with overload , short circuit and earth fault protection , breaking capacity 16 KA- 1No (c) Digital ammeter 0-500 V with selector switch 96mm x96 mm square flush mounted -1 No (d) Digital ammeter 0-500A with selector switch 96mm x96 mm square flush mounted -1 No (e) Indicating lamps LED panel mounted type RYB-03 Nos OUTGOING: (h) Digital timer switch of 5 KW three phase (i) contactor 32 A TPN (Suitable capacity as per sr no - h) -with 2 No + 2 NC (j) 3 way selector switch for manual ON/OFF/Auto switching of street light fittings (k) Internal wiring with single core copper conductor cable /PVC insulated copper strip of suitable size incoming to bus bar and bus bar to outgoing MCCB : 1 Job

-

-

-

... More
Supply, fix, testing & commissioning for outdoor Bus bar box size 600 x 400 x 300 mm fabricated out of 3.15 mm thick MS Sheet having 4 Nos closed Aluminium bus bar chamber of capacity 100 A (including necessary insulator) suitable for 3 phase & neutral, 4 wire 50 Hz AC,415V with suitable size of MCCB controlling including red,blue & yellow LED indication lamp and both side openable hinged cover with proper locking arrangement ,outdoor type weather proof & powder coated with angle iron of size 50x50x5 mm(including painting of angle iron) outoor, floor mounting 30 cm grouting including making PCC 1:2:4 type B-1 using 20 mm graded course aggregate block with complete plastering & white wash etc also includes provision of suitable size of cable glands,cable lugs,nut, bolts,washers etc for fixing of cable with the bus bar.The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron all as specified and directed.

5

-

-

... More
Supply & Fixing 100mm bore GI tubing Light grade with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps incl nut,bolt and washer complete all as specified and directed. NOTE - Excavation and Earthwork shall be measured and paid separately under appropriate item of this schedule)

78

-

-

... More
Supply & Fixing 80mm bore GI tubing Light grade with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps incl nut,bolt and washer complete all as specified and directed. NOTE - Excavation and Earthwork shall be measured and paid separately under appropriate item of this schedule)

100

-

-

... More
Supply & Fixing 50mm bore GI tubing Light grade with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps incl nut,bolt and washer complete all as specified and directed. NOTE - Excavation and Earthwork shall be measured and paid separately under appropriate item of this schedule)

72

-

-

... More
Supply & Fixing 40mm bore GI tubing Light grade with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps incl nut,bolt and washer complete all as specified and directed. NOTE - Excavation and Earthwork shall be measured and paid separately under appropriate item of this schedule)

400

-

-

... More
S&F of integral LED Street light luminaire of not less than 60 W, lumen efficacy not less than 125 lm per watt, comprising of die cast alluminium housing, enclosed with glass cover in frame, IP-66 protection suitable for voltage range should be 170 to 240 Volts and with all fixing arrangement, nuts, bolts and washer connecting to electric system with 1.5 sqmm PVC aluminium stranded conductor 3 core connected upto pole box, on pole including testing complete and fixed with and including bracket made out of GI pipe 40 mm dia (light grade) 1.2 metre long and MS clamp and nut bolts washer all as specified and directed.

10

-

-

... More
Supply, fixing testing and comissioning, of automatic street light switch of capacity 5 KW in three phase, using Nature switch for automatic switching of street lights based on LUX level of natural light. The sensor (nature switch) along with suitable power contractor, MCB and support terminals enclosed in pole/ wall mounted enclouser made of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP54, including mounting arrangement with suitable size of iron clamps 02 Nos with complete acessories complete all as specified and directed. The automatic switching unit shall comprising of following: (i) Contactor rating (AC3) 25 Amp TPN or 3 Nos 25Amp SP: (ii) MCB 32Amps (SP),10 KA, 240 volts (SP 3Nos) (iii) NATURESWITCH-01

8

-

-

... More
Earth work in excavation in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan and nexc 1.5 m in depth including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the hard dense soil complete all as specified and directed .

23988.9

-

-

... More
Earth work in excavation in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan and nexc 1.5 m in depth including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the Soft Disintegrated rock complete all as specified and directed .

4500

-

-

... More
Earth work in excavation in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan and nexc 1.5 m in depth including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the Hard rock complete all as specified and directed .

2000

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) as in over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal upto 50m in all kind of soil complete all as specified and directed.

33.75

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) in all kinds of soils as in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. complete all as specified and directed.

108

-

-

... More
Excavating in post holes (or similar holes) each n.exc 0.5cum, getting out, returning, filling in and remaining earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n.exc 50m and making good surface in soft/loose Soil complete all as specified and directed.

216

-

-

... More
Returning filling in all kind of soil, including spreading, levelling,watering and well ramming in layer not exceeding 25 cm in each layer, complete all as specified & directed.

17968.68

-

-

... More
Removal of Excavated Soil to a distance not exc. 50 Mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and directed.

8504.82

-

-

... More
Removal of Excavated Rock to a distance not exc. 50 Mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and directed.

4091

-

-

... More
Material and Labour for 200 mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars laid in trenches and jointed in CM (1:1) including testing complete all as specified & directed. Note : Excavation, Returning filling and removal shall be measured and paid seperately.

213

-

-

... More
Material and Labour for 200 mm bore Reinforced concrete pipes, class NP3, laid and jointed complete with collars laid in trenches and jointed in CM (1:1) including testing complete all as specified & directed. Note : Excavation, Returning filling and removal shall be measured and paid seperately.

85

-

-

... More
Material and Labour for 450 mm bore Reinforced concrete pipes, class NP3, laid and jointed complete with collars laid in trenches and jointed in CM (1:1) including testing complete all as specified & directed. Note : Excavation, Returning filling and removal shall be measured and paid seperately.

5

-

-

... More
M & L for Concrete Bed for 200mm dia. drain pipes including forming cradles in cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate complete all as specified & directed.

298

-

-

... More
M & L for Concrete Bed for 450mm dia. drain pipes including forming cradles in cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate complete all as specified & directed.

5

-

-

... More
M&L for moorum / red bajri filling in floors or pavings laid in layers n exc 15 cm thick spread, levelled, watered complete all as specified and directed.

187.8

-

-

... More
M&L for 150mm thick (compacted thickness) WBM in two layers of 75mm each, with coarse aggregates using granite, trap or basalt of grading 2 (63 to 40mm size), spread, rolled and consolidated to required gradient and camber with power roller complete all as specified and directed.

62.6

-

-

... More
M&L for Preparing WBM by brushing with wire brushes for removing caked mud etc., sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. on unsurfaced water bound macadam inclusive of applying evenly a tack coat with paving bituminous primer using bitumin of grade VG-10 @ 10 kg per 10 sq metre complete all as specified and directed.

62.6

-

-

... More
M&L for laying Premix bituminous macadam (consolidated thickness 50 mm) with 4% binder content (Paving bitumen of grade VG-30) by weight of total mix with self propelled mechanical paver duly rolled and compacted to required camber and gradient with 08 to 12 Tonne Power roller and vibrating roller etc complete all as specified and directed. Note :- (a) Exact thickness of Bituminous macadam shall be given in writing by GE before execution of the work. (b) In case, the required Bitumen/binder content in design of bituminous macadam is arrived less than 4% the rate quoted shall be adjusted @ Rs 55/KG of Bitumen. However, no price adjustment shall be made in case the binder content is derived more than 4%. (c) Design mix shall be got carried out from any Govt Engg College/NABL/MES approved laboratory and approved by CWE in writing before execution. The cost thereof shall be deemed to be included in quoted unit rate.

31.3

-

-

... More
M&L for laying bituminous premix asphaltic semi dense concrete 30mm consolidated thickness with 5.5% binder content by weight of total mix, using VG 30 bitumen, rolled and compacted to a required camber and gradient and rolling to a smooth surface with 8 to 10 ton power roller complete all as specified and directed. Note : (a) In case, the required Bitumen/binder content in design of bituminous premix asphaltic semi dense concrete is arrived less than 5.5% the rate quoted shall be adjusted @ Rs 55/KG of Bitumen. However, no price adjustment shall be made in case the binder content is derived more than 5.5%. (b) Design mix shall be got carried out from any Govt Engg college/ NABL/MES approved laboratory and approved by CWE in writing before execution. The cost thereof shall be deemed to be included in quoted unit rate.

62.6

-

-

... More
Material and labour for Cement Concrete 1:4:8 type D-2 (40mm graded crushed stone aggregate) in foundation, filling and mass concrete in foundation etc complete all as specified and directed.

201.13

-

-

... More
Material & Labour for Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded aggregate) in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses etc complete all as specified and directed.

1

-

-

... More
Material & Labour for Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed.

27.52

-

-

... More
Material & Labour for Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded aggregate) in Foundation, Base of column, Plinth Beam etc. complete all as specified and directed.

2.85

-

-

... More
Material & Labour for Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded aggregate) in column, pillars, post and struts etc. complete all as specified and directed.

0.9

-

-

... More
Material and labour for PCC (1:2:4) type B1 using 20mm graded stone aggregate as in lintal upto 1.5m span, bands, string course, copings, apex stone, bed plate, kerbs, haunching and the like including weathering, slightly rounded or chamfered angle with and including necessary use and waste of form work complete all as specified & directed.

23.58

-

-

... More
M&L providing precast cement concrete type B1 (1:2:4) using 20mm graded aggregate as in landing cover, drain cover, man hole cover water troughs and in similar work and set in CM 1:4 etc complete all as specified and directed.

2

-

-

... More
M&L for plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) in foundation filling & mass concrete, complete all as specified & directed.

56.55

-

-

... More
M&L RCC M-25 (20mm graded aggregate) as in Foundation, Base of column, Plinth Beam etc. complete all as specified and directed.

5.07

-

-

... More
M&L RCC M-25 (20mm graded aggregate) as in column, pillars, post and struts etc. complete all as specified and directed.

2.97

-

-

... More
M&L RCC M-25 (20mm graded aggregate) for Beam, cantilevers, bressummers, lintels over 1.5m span etc. complete all as specified and directed.

9.18

-

-

... More
S&F Form work to flat fair finished surfaces sides of concrete foundations, footing base of columns side of pillars & similar work complete all as specified and directed.

46.5

-

-

... More
S&F Form work to flat fair finished surfaces sides of pillars, post, struts, piers, columns and stanchions complete all as specified and directed.

54.6

-

-

... More
S&F Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs,etc. also splays between floors and beams, etc complete all as specified and directed.

91.8

-

-

... More
S&F Form work to flat surfaces faces/sides of walls and soffit of culverts vertical or to batter complete all as specified and directed.

180

-

-

... More
M&L TMT BARS as in reinforcement 10mm dia and over cut to length bent to shape required incl cranking binding with mild steel wire annealed not less than 0.9mm complete all as specified and directed.

1825.43

-

-

... More
M&L Mild steel TMT bars above but 6 to 8mm dia bar and over cut to length bend to shape as required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia. complete all as specified and directed.

798.2

-

-

... More
Material & labour, for machine pressed precast concrete Interlocking paver block finished with grey cement with No pigment confirming to IS 15658-2006 of 60mm thickness M-35 Grade & size, shape and pattern as approved by GE, complete all as specified & directed.

1754.8

-

-

... More
M & L for laying of sand in base for cushion of PCC interLocking blocks complete as specified & directed.

87.74

-

-

... More
Material and labour for Modular Size Fly Ash Brick work , straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed.

13

-

-

... More
Material and labour for old size Fly Ash Brick work , straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed.

98.51

-

-

... More
Material and labour for rendering 15mm thick in cement mortar 1:4 on fair surfaces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.

80

-

-

... More
Material and labour for rendering 10mm thick in cement mortar 1:4 on fair surfaces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.

756.7

-

-

... More
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc

246

-

-

... More
M&L for preparation of new surfaces of walls and providing two coats of Cement Based Paint complete all as specified and directed by Engineer-in-charge.

356.7

-

-

... More
M&L for 2 coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description exc 10 cm in width or girth complete all as specified and directed.

94.01

-

-

... More
Supply & fixing Mild steel work of Fe-290 Gde E -165 as in angle iron fencing posts & flat iron drilled and countersunk for boulders running bars,including embedding in concrete and scruing etc,post and struts in fencing including cutting, tops to shape as directed, bent to shape, drilling holes, notching for wire etc,flat iron fillets (for securing wire mesh etc.) Including all necessary drilling,bolting or riveting etc.complete all as specified and shown on drawings. Note:- The element of Fixing of round bars for chain link fencing is included in this item .Nothing shall extra be paid on this account .

2429.92

-

-

... More
Supply only Chain link fencing including line wires, any mesh, size and type to any type of standard, rails, straining bolts etc including provision of binding wire complete all as specified and directed.

1304.32

-

-

... More
Fixing only Chain link fencing including line wires, any mesh, size and type to any type of standard, rails, straining bolts etc including provision of binding wire complete all as specified and directed.

553.5

-

-

... More
M&L mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm in length, dia of neck 11 to 15 mm complete all as specified and directed.

73

-

-

... More
S&F mild steel round bars 10mm dia and over cut to length bent to shape required including cranking, bending, spirally for hooking ends stiffeners confirming to FE-410-W ( Gde E 250) quality-A or Fe 290 (Gde E-165) complete all as specified and directed

910.69

-

-

... More
Supply & fix Bands, straps, supports or stays for hooks for hanging fans similar conforming to Fe-290 Gde E-165 complete all as required at site complete all as specified and directed.

750.34

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.