Madhya Pradesh State Open School Education Board Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Madhya Pradesh State Open School Education Board Tender
Civil And Construction
Building Construction
Eprocure
Opening Date29 Aug 2022
Closing Date13 Oct 2022
Tender Amount₹ 1,12,34,300
Costs
EMD
₹ 2,60,000Document Cost
₹ 15,000Tender Fee
Refer Documents
Summary
Construction Of Additional Classrooms
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_SOSEB_218646_1Bid Award Id
ViewTender No
09/MPSOS/Indore-15/2022/3388Tender Authority
Madhya Pradesh State Open School Education Board ViewPurchaser Address
-Website
http://mptenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Tender Document for construction of additional classroom at Govt. Swami Vivekananda Higher secondary school campus, Indore
BOQ Items
... More
Earth work in excavation/ bymechanical means (HydraulicExcavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited)
59.22
-
591
... More
Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : M-15 Grade Concrete
26.77
-
5397
... More
Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : M-20 Grade Concrete
121.61
-
5796
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : With 20mm nominal size graded stone aggregate. M-20 – Grade concrete
51.52
-
4933
... More
Centering and shuttering in cluding strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for concrete upto plinth level
776.76
-
190.6
... More
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete .
(Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge.
2. No extra payment shall be done for overlaps and/or couplers.
3. Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement -Specification”)
Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786 140 Kg per CUM Concrete
17025.12
-
62.9
... More
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 sand) finished with a top layer 6mm thick cement plaster 1:4 (1 cement : 4 sand).
100.8
-
220
... More
With hard muram having CBR 12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm)
320
-
300
... More
Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing complete Note: - Maximum thickness of this layer shall be 20 cm.
24
-
672
... More
Providing and laying factory made coloured chamfered edge Cement Concrete paver blocks of required strength, thickness and size/shape, made by table vibratory method using PU mould, laid in required colour and pattern over 50mm thick compacted bed of stone dust, compacting and proper embedding/laying of inter locking paver blocks into the bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand including locking edges with M 15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturer's specifications and direction of Engineerin- Charge. 60mm thick C.C. paver block of M-35 grade with approved colour, design and pattern.
168
-
702
... More
White washing with lime to give an even shade: New work (three or more coats)
140
-
11
... More
Finishing walls by only mechanical or manual means with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm.
140
-
132
... More
Providing and laying vitrified floor tiles Multi/Double charged (Minimum top layer thickness 2.0mm) Neno Polished self design, in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, quality/ premium quality in flooring laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete In light shade glossy/ rustic /stain finished.Size 600X600 mm thickness 9-10 mm
762.8
-
1104
... More
Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and upto floor two level excluding cost of centering, shuttering, finishing and reinforcement:M-20 Grade Concrete
194.18
-
5865
... More
Centering and shuttering in cluding strutting, propping etc. and removal of form for:Columns, P i l l a r s , Piers, Abutments, Posts and Struts.
270.72
-
471.2
... More
Centering and shuttering in cluding strutting, propping etc. and removal of form for: Lintels, beams, girders, bressumers and cantilevers
554.76
-
356
... More
Centering and shuttering in cluding strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform.
733.52
-
439.6
... More
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete .
(Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge.
2. No extra payment shall be done for overlaps and/or couplers.
3. Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement -Specification”)
Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786
27185.76
-
62.9
... More
Providing and laying Autoclaved Aerated Concrete (AAC) blocks masonry, using AAC blocks (Size length 300, 400, 500, 600 mm Height 200, 250, 300 mm Width 100, 150, 200, 250 mm) conforming to IS 2185 PART 3, having compressive strength not less than 4 MPa (Grade II) in super structure, blocks jointed with approved block laying polymer modified adhesive mortar as per ASTM 1660-09,applied in uniform thickness of 2 to 3 mm in horizontal and verticals joints using special trowel, polymer modified mortar having minimum compressive strength and minimum splitting tensile strength of not less than 5MPa and 0.34 MPa respectively as per ASTM international standard including raking out joints. AAC Masonry in polymer modified mortar
199.4
-
5500
... More
12 mm cement plaster of mix : 1:4 (1 cement : 4 sand) inner plaster
1961.12
-
149
... More
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 sand) finished with a top layer 6mm thick cement plaster 1:4 (1 cement : 4 sand).OUTER PLASTER
833.8
-
220
... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete. Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of APD/Chief Engineer will be required.
1961.12
-
74
... More
White washing with lime to give an even shade: New work (three or more coats)
2794.92
-
11
... More
Finishing walls by only mechanical or manual means with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm.
2794.92
-
132
... More
Granite stone work 18mm thick of any colour in riser of steps, skirting, dado and pillars laid on 12 mm average thick cement mortar 1:3 (1 cement:3 sand) and jointed with white cement slurry mixed with pigment to match the shade of slab. (Door Paneling)
105
-
3413
... More
Providing and fixing pressed steel door frames made of 1.6 mm thick steel profile conforming to IS: 4351 manufactured from commercial mild steel sheet including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.60 mm pressed mild steel welded or rigidly fixed together by mechanical means, including 2.5mm thick M.S. pressed butt hinges, with mortar guards, lock strike-plate and shock absorbers as specified filling the frame with Cement Concrete 1:3:6 at site before fixing (cost of concrete to be paid separately) fixing with adjustable lugs (200 mm long & 1.0 mm thick) and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in- charge: Profile E of 1.25mm thick double rebate of size 115mmx50mm
Fixing with adjustable lugs with split end tail to each jamb.
164
-
414
... More
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutter.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
55.2
-
2600
... More
Providing and fixing ISI marked stainless steel sliding door bolts with nuts and screws etc. complete :300x16 mm
40
-
389
... More
Providing and fixing ISI marked stainless steel tower bolt black finish, (Barrel type) with necessary screws etc. complete :200x10 mm
40
-
93
... More
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm) with necessary accessories and screws etc. complete.
40
-
1186
... More
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
Twin rubber stopper
40
-
86
... More
Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete :
125 mm
40
-
60
... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of aluminium structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels.
22.05
-
2674
... More
Steel work in built up M.S. tubular section (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes ( @ 15 kg Each)
300
-
109
... More
Granite stone work 18mm thick of any colour in riser of steps, skirting, dado and pillars laid on 12 mm average thick cement mortar 1:3 (1 cement:3 sand) and jointed with white cement slurry mixed with pigment to match the shade of slab.
72
-
3413
... More
As per required size
72
-
1000
... More
Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete :
125 mm
36
-
60
... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of aluminium structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels.
58.32
-
2674
... More
Steel work in built up M.S. tubular section (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes (Window Grill @ 60 kg each)
1080
-
109
... More
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or S trap, UPVC P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :or as per direction of Engineer-in- Charge.White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.
5
-
2995
... More
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fittings and C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid.
1
-
4613
... More
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required or as per direction of Engineer-in- Charge.Single half stall urinal with 5 litre P.V.C. automatic flushing cistern.
5
-
5567
... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :or as per direction of Engineer-in- Charge.White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap.
8
-
1664
... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This included jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer-in- Charge. External Work. 25 mm nominal outer dia .Pipes.
80
-
185
... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This included jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer-in- Charge. External Work. 20 mm nominal outer dia .Pipes.
200
-
141
... More
Providing and laying below ground unplasticised PVC pipe to with stand working pressure of 4 kg/cm2 soild waste pipes confirming to IS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving 10mm gap for thermal expansion all necessary fittings etc. complete. Excavation to be paid seperataly.or as per direction of Engineer-in- Charge.110 mm diameter OD (min. wall thickness 3.2mm)
80
-
234
... More
PVC made Water Tank
2
-
6000
... More
Point wiring (excluding metallic switchbox & sheet but including switches,sockets, lamp holders/ceiling roses etc)sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :-Light point/fan points.
Primary short point
60
-
268
... More
Primary medium point
80
-
471
... More
Primary long point
60
-
687
... More
3 Pin 6 Amp socket outlet on separate board
Short point
24
-
375
... More
Medium point
30
-
600
... More
Long point
36
-
851
... More
Call bell/buzzer points
Medium point
8
-
425
... More
Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid
P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside casing & capping with required materials as per specification on same board.
16
-
224
... More
Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping of ISI marked suitable size etc. as required as per specification.
2x2.5 Sq.mm.
8
-
71
... More
4x2.5 Sq.mm.
14
-
111
... More
6x2.5 Sq.mm.
12
-
151
... More
8x2.5 Sq.mm.
10
-
190
... More
Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size etc. with 20/16 Amp.
F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :-On separate board. Short point
16
-
576
... More
Medium point
12
-
943
... More
Long point
8
-
1360
... More
Extra long -I
4
-
1873
... More
Extra long -II
6
-
2433
... More
Same board switch & socket 16 Amp./S.S. combined 20/16/6 Amp
8
-
342
... More
Supplying and fixing factory fabricated hot dip galvanized switch box for normal flush type accessories of minimum 1.2 mm thickness for up to 200mmx250mm size boxes and 1.6mm minimum thickness for higher size boxes, earth terminal stud with nut and washer, including 3 mm thick synthetic phenolic resin bonded laminated sheet conforming to grade P-I of IS:2036- 1974 on surface/concealed including all necessary accessories, painting etc. as required as per specification:
MS box 100 mm X 100 mm X 60mm
10
-
64
... More
MS box 200 mm X 150 mm X 60 mm
8
-
77
... More
MS box 180 mm X 100 mm X 60 mm
12
-
57
... More
MS box 125 mm X 300 mm X 60 mm
16
-
73
... More
Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as
required for:-1Or 2 Module metal box
4
-
92
... More
3 Module metal box
4
-
115
... More
6 Module metal box
4
-
173
... More
8/9 Module metal box
4
-
218
... More
Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-6 Module PVC box
6
-
138
... More
8/9 Module PVC box
6
-
183
... More
12 Module PVC box
6
-
223
... More
Wiring for sub-mains with PVC insulated cable FRLS with copper multi strand conductor ISI marked in recessed/concealed rigid PVC conduit (HMS) FRLS ISI marked of suitable size (conduit included) including 2mm thick accessories, connection etc, as required as per specification. (Refer General Notes for Classification of Conduit Wiring
Point No.11)3 Wire sub main.
25.0 sq. mm. cable
320
-
589
... More
Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but
without enclosures :-MCB SP 6Amp to 32Amp 10kA rating
48
-
136
... More
Four pole MCB FP 50Amp to 63 Amp 10kA rating
6
-
1348
... More
Supplying of approved make vertical TPN MCB DB metal double door IP 43 protection with provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP/TP MCBs as outgoing inclusive of busbar, neutral bar, earth bar, & two earth terminals etc. complete as per
IS:13032(exclusive of MCB & isolator)
4 Way (8+12)
8
-
5103
... More
Supply and fixing of LT panel accessories of approved make in existing LT panel including connections
etc. as required as per specification.
Digital Ampere Metre with CTs with
selector switch
4
-
1773
... More
Digital Volt Metre with selector switch
& HRC fuse
4
-
1909
... More
Frequency Metre
4
-
1091
... More
Supply and fixing M.S. down rod 14 SWG (2mm) thick for ceiling fan including threading, painting, making holes etc. as required complete.
Note: For new works difference of installed & standard down rod length shall be paid.
200
-
60
... More
Earthing with copper earth plate 600mm X 600mm X 3mm thick including accessories and providing masonry encloser in cement mortar, cover plate having locking arrangement on the top and G.I. watering pipe 20mm dia 2.7 metre long etc. (but without charcoal or coke and salt) complete as required
2
-
8461
... More
Add extra for using salt and charcoal/coke for G.I. plate or copper plate earth electrode as required including excavation in hard rock and refilling the pit with black soil.
2
-
2365
... More
Providing and fixing 25mm X 5mm
copper strip in 40 mm dia G.I. Pipe from earth electrode as required
100
-
1064
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements