Madhya Pradesh State Cooperative Housing Federation Limited Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Madhya Pradesh State Cooperative Housing Federation Limited Tender

Works
Eprocure
Opening Date9 Oct 2020
Closing Date19 Oct 2020
Tender Amount₹ 4,45,32,000 
Notes
Download

Costs

  • EMD

    ₹ 4,45,320
  • Document Cost

    ₹ 15,000
  • Tender Fee

    ₹ 1,534

Summary

Supplying And Installation Of Lift

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(iii) Speed : 1.00 Meter/sec.

-

-

-

... More
(iV) Control : ACV3F, 32bit Microprocessor integrated serial communication control system with RMS (Remote monitoring system) / BMS (Building monitoring system) supporting software.

-

-

-

... More
(v) Motor/Machine : Permanent magnetic synchronous gearless motor.

-

-

-

... More
(vi) Operation : Simplex collective selective with/without lift attendant.

-

-

-

... More
(vii) Total rise : about 3 mtr. (Approx) two stops only.

-

-

-

... More
(viii) Landings : All floor on same side.

-

-

-

... More
(ix) Floors served : G+1

-

-

-

... More
(x) Signals : Digital car position indicator, car travel direction indicator inside car & at all landing, Voice annunciator with suitable music shall be provide in the lift car.

-

-

-

... More
(xi) Shaft size : As per manufacture's design and as per CPWD specification (Part III LIFTS), Shall to be constructed separately.

-

-

-

... More
(xii) Guide rail : As per manufacturer's specification.

-

-

-

... More
(xiii) Lift & Car size : As per manufacturer's design and as per CPWD specification (Part III LIFTS)

-

-

-

... More
(xiv) Car entrance : As per manufacturer's design and as per CPWD specification (Part III LIFTS)

-

-

-

... More
(xv) Landing entrance : As per manufacturer's design and as per CPWD specification (Part III LIFTS)

-

-

-

... More
(xvi) Car door : S.S (Stainless steel) Hairline finish center/Telescopic opening door with vision panel.

-

-

-

... More
(xvii) Landing door ; S.S (Stainless steel) Hairline finish center/Telescopic opening door with vision panel.

-

-

-

... More
(xviii) Door operation : Automatic electric power operated door, Full height infra red curtain with multiple criss/cross light beams.

-

-

-

... More
(xix) Car interier : S.S (Stainless steel) panel with hair line finish on all sides.

-

-

-

... More
(xx) Car floor : Anti skid PVC flooring on heavy duty M s (Mild Steel) Platform.

-

-

-

... More
(xxi) Car ceiling & lighting : S.S (Stainless steel) finishes with aesthetic appearance with LED ceiling lights.

-

-

-

... More
(xxii) Car ventilation : Pressure fan / Blower fan (Car fan with automatic sleep timer shall be provided)

-

-

-

... More
(xxiii) Emergency lighting in car : Battery operated emergency lighting in the lift car.

-

-

-

... More
(xxiv) Intercom system : Battery operated interoom system in lift car, machine room and ground floor/control room.

-

-

-

... More
(xxv) Emergency alarm : Battery operated alarm bell system in lift car & control room/Ground floor.

-

-

-

... More
(xxvi) Position of machine room : Directly above the hoist-way.

-

-

-

... More
(xxvii) Electric power supply : Ac 415 V, 3 Phase 50 Hz & AC 230V 1 Phase 50Hz terminated in machine room.

-

-

-

... More
(xxviii) Fire man switch : Fire man switch at machine room /Terminal landing.

-

-

-

... More
(xxix) All car panel buttons and all floor switches must be with brail language as per lift act.

-

-

-

... More
(xxx) Audio visual indication in the lift car showing overloading shallbe provided such that doors kept open till excess load is removed.

-

-

-

... More
(xxxi) Spring buffer/Hydraulic buffers shall be provided

-

-

-

... More
(xxxii) Mechanical over speed governor, door key holes in the floor doors shall be provided.

-

-

-

... More
(xxxiii) Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the lift agency. Along with other steel structure works, foundations for the machines etc.

-

-

-

... More
(xxxiv) In the hoist way fascia plate shall be provided.

-

-

-

... More
(xxxv) Permanent wiring in lift machine room and lift well with proper no. of light points, with fixtures, exhaust fan, plug points and 3 phase 440V power supply shall be made available by the department in lift shaft, machine room or at desired level.

-

-

-

... More
(xxxvi) Car top safety barricade shall be provided.

-

-

-

... More
(xxxvii) ARD (Automtic rescue device) : Solid state inbuilt automatic rescue device (ARD) for automatically rescues passengers trapped in the lift car in between floors in the event of power failure. Automatic operation and immediate action in the event of mains failure capable to move the lift to the nearest landing. opens the automatic door of the lift car and floor. Sealed maintenance free battery backup with automatic charging unit and auto changeover device on mains failure.

-

-

-

... More
Passenger Capacity

-

-

-

... More
(iv) 8 Passenger (544kg.)

4

-

1485000

... More
(v) 13 Passenger (884kg.)

6

-

1710000

... More
(vi) 16 Passenger (1088kg.)/ Stretcher Lift

6

-

1935000

... More
Add extra for higher speed

-

-

-

... More
(i) For higher speed 1.5 Meter/sec (For 4 - 10 Passenger)

4

-

81000

... More
(ii) For higher speed 1.5 Merter/sec (For 13 - 26 Passenger)

12

-

99000

... More
Add extra for every additional floor beyond initial G+1 floor (additional stops beyond two stops) provide all necessary additional parts/ equipments as per manufacturer's requirement.

-

-

-

... More
(i) Cost for each additional floor : up to 9 stops (For 4 - 10 Passengers)

36

-

67500

... More
(ii) Cost for each additional floor : up to 9 stops (For 13 - 26 passenger)

108

-

85500

... More
(iii) Above 9 stops but max. up to 16 stops (For 4 - 10 Passenger)

4

-

76500

... More
(iv) Above 9 stops but Max. up to 16 stops (For 13 - 26 Passenger)

6

-

135000

... More
Add Extra for Machine Room Less (MRL) Lift in place of machine room directly above the hoist way.

-

-

-

... More
Extra cost for Machine Room Less (4 -13 Passenger

10

-

135000

... More
Extra cost for Machine Room Less (16 and above passenger capacity)

6

-

180000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.