Madhya Pradesh State Cooperative Housing Federation Limited Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Madhya Pradesh State Cooperative Housing Federation Limited Tender
Civil And Construction
Building Construction
Eprocure
Opening Date19 Jul 2024
Closing DateCancelled
Tender Amount₹ 2,08,19,030
Costs
EMD
₹ 2,08,190Document Cost
₹ 15,000Tender Fee
₹ 1,534
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MSCHF_358374_1Bid Award Id
ViewTender No
Aws/Tech./2024/640 dt. 18.07.24Tender Authority
Madhya Pradesh State Cooperative Housing Federation Limited ViewPurchaser Address
-Website
http://mptenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
SOR 2.24 Filling abailable excavated earth in tranches plinth sides of foundation etc.
-
-
-
SOR 2.27.1 Supplying and filling in plinth with Hard muram/ Hard copra under floors including, watering, ramming consolidating and dressing complete
-
-
-
SOR 2.32 Preconstruction antitermite treatment to the building under construction by providing Stage 1: Treating the bottom and the sides (upto 30cm hight of the excavated trench @ 5 litter per sqm of the surface area. Stage 2: After masonry/RCC work, the backfill in the immdiate contact with the foundation structure treatment @ 7.5 litter per sqm. of the vertical surface of the substructure for each side. Stage 3: surface treatment by spreading emulsion over the plinth area before laying the base concrete under floors @ 5.0 litres/Sqm.
-
-
-
SOR 4.1.1.2 Providing and laying cement concrete in retaining wal s, return walls, walll (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets,coping, bed blocks, anchor blocks, plain window sil s, fil ets etc. up to floor two level, excluding the cost of centering, shuttering and finishing : M-20 With 20 mm nominal size graded stone aggregate
-
-
-
SOR 4.1.2.2 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level with 40 mm nominal size graded stone aggregate M-10
-
-
-
SOR 5.1.1 P/L in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level M-20 Nominal mix (with 20 mm aggregate)
-
-
-
SOR 5.2.1 Reinforced cement concrete work (with 20mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and up to floor two level excluding cost of centering, shuttering, finishing and reinforcement :
-
-
-
SOR 5.3.1 Reinforced cement concrete work (with 20mm nominal size graded stone aggregate) in beams, suspended floors, roofs having slope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level and up to floor two level excluding the cost of centering, shuttering, finishing and reinforcement in concrete grade. M 20 –Grade Concrete
-
-
-
SOR 5.9.1 Centring and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases of Columns for mass concrete up to plinth level
-
-
-
SOR 5.9.2.1 Centring and shuttering including strutting, propping etc. and removal of form work for Walls (any thickness) including at ached pilasters buttresseds, plinth beams and string courses etc.up to plinth level.
-
-
-
SOR 5.9.3 Centring and shuttering including strutting, propping etc. and removal of form Suspended floors, roofs, landings, balconies and access platform.
-
-
-
Office & Toilet Slab
-
-
-
SOR 5.9.5 Centring and shuttering including strutting, propping etc. and removal of form work for Lintels, beams, girders, bressumers and cantilevers.
-
-
-
Godown Ventiloter Sill Beam
-
-
-
SOR 5.9.6 Centring and shuttering including strutting, propping etc. and removal of form work for Columns, Pillars, Piers, Abutments, Posts and Struts.
-
-
-
SOR 5.9.19 Centring and shuttering including strutting, propping etc. and removal of form work for Weather shade, Chajjas, corbels etc., including edges.
-
-
-
SOR 5.16.6 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete . TMT Bars
-
-
-
SOR 6.7.3.2 Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor II level in : having 50 kg / cm2 average compressive strength Cement mortar 1:6 (1 cement : 6 sand)
-
-
-
SOR 6.5.2 Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg /cm2 and water absorpt ion not more than 20% in foundation and plinth i/c curing etc complete. Cement mortar 1:6 (1 cement : 6 sand)
-
-
-
SOR 9.43.1 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. Fixed to steel windows by welding
-
-
-
SOR 10.1 Structural steel work in single section fixed with or without connecting plate including cutting, hosting, fixing in psotion and applying a priming coat of approved steel primer all complete.
-
-
-
SOR 10.5.1 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x5mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6mm for diagonal braces
-
-
-
SOR 10.6.1 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on 27.5cm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm 80x1.25mm M.S. laths with 1.25 mm thick top cover
-
-
-
SOR 10.9 Providing and fixing ball bearing for rolling shutters.
-
-
-
SOR 10.10.1 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators side /top /centre hung with beading and all members such as K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted with 15x3mm lugs, 10cm long, embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of hinges,pivots,
-
-
-
SOR 11.2 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50kg of cement or as per manufacturers specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
-
-
-
SOR 10.14.1 Steel work in built up tubular trusses including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete. Hot finished welded type tubes.
-
-
-
Main truss
-
-
-
Godown & Veramdha Truss
4238.65
457774
108
SOR 10.18 Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
-
-
-
S.O.R. 10.13.1 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of Cement Concrete 1:3:6 (1 Cement : 3 sand : 6 graded stone aggregate 20 mm nominal size).
-
-
-
SOR 10.27.1 Providing and fixing glazing in steel doors windows, ventilator, shutters & partitions etc. per architectural drawing & asper direction of engineer-in-charge. With steel beading metal sash puttey. With float glass 4 mm thick
-
-
-
SOR 12.15 Supply & installation of silicon modified polymer precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineerin- charge)0.50 mm +/- Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
-
-
-
SOR 12.16.1 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
-
-
-
SOR 12.16.2 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Flashings/ Aprons.( Upto 600 mm)
-
-
-
SOR 11.78.1.1 Providing and laying vitrified floor tiles Multi/Double Charged (Minimum top layer thickness 2.0mm) Nano Polished self design, in different sizes with water absorption less than 0.05% and conforming to IS : 15622 of approved make in all colours & shades, 1st quality/ premium in flooring , laid on 20 mm thick cement mortar 1:4 (1 cement : 4 sand) including grouting the joints with white cement and matching pigments etc complete. In light shade glossy/rustic/satin finished (A) Size 600x600 mm thickness 9-10 mm
-
-
-
SOR 11.79.1.1 Providing and laying vitrified floor tiles Multi/Double Charged (Minimum top layer thickness 2.0mm) Nano Polished self design, in different sizes with water absorption less than 0.05% and conforming to IS : 15622 of approved make in all colours & shades,1st quality /premium in skirting, laid on 12mm thick cement mortar 1:3 (1 cement : 3 sand ) including grouting the joints with white cement and matching pigments etc complete. In light shade glossy/rustic/satin finished (A) Size 600x600 mm thickness 9-10 mm
-
-
-
SOR 11.50 Providing and laying rectified Glazed Ceramic floor tiles 300x 300 mm or more (having thickness 9 to 10mm ) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 ( 1cement : 4 sand ) including grouting the joints with white cement and matching pigments etc. complete.
-
-
-
Toilet Floor Tiles
4.32
-
-
SOR 11.51 Providing and laying rectified Glazed Ceramic wall tiles 300x450 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours White , Ivory, Grey, Fume red brown, laid on 12 mm thick cement mortar 1:3 (1cement :3 sand) prepared same day when mortar is still green i.e. within 6 hours including grouting the joints with white cement and matching pigments etc, complete.
-
-
-
SOR 13.1.2 12 mm cement plaster of mix : 1:6 (1 cement: 6 sand)
-
-
-
SOR 13.3.2 20 mm cement plaster on rough side of single or half brick wall of mix :1:6 (1 cement: 4 sand)
-
-
-
SOR 13.10 Neat cement punning
-
-
-
SOR 13.27 Providing and fixing chicken mesh as per ISI specification and in the required width with 50mm long Bombay nails on vertical and horizontal junctions of RCC and brick wall including scaffolding and all lead and lift etc. complete before plastering upt 10 meter height.
-
-
-
SOR 5.24 Providing for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
-
-
-
SOR 13.54.3 Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Two or more coats applied on walls @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10 sqm.
-
-
-
SOR 13.65 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
-
-
-
SOR 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.,
-
-
-
SOR 18.8.1 15 MM Dia Nominal outer dia .Pipes.
-
-
-
SOR 18.8.3 25 MM Dia Nominal outer dia .Pipes.
-
-
-
SOR 18.8.4 32 MM Dia Nominal outer dia .Pipes.
-
-
-
SOR 17.58.2 Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. 110 mm diameter (minimum wall thickness 3.2mm)
-
-
-
SOR 17.59 Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
-
-
-
SOR 17.59.4.2 Single tee without door 110x110x110 mm
-
-
-
SOR 17.59.5.2 Bend 87.5° 110 mm Bend
-
-
-
SOR 17.61.1 Providing and fixing UPVC trap of self cleaning design complet. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet
-
-
-
SOR 19.9.1 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80 cm and 45 cm
deep including C.I. cover with frame (light duty) 455x610 mm
internal dimensions total weight of cover and frame to be not
less than 38 kg (weight of cover 23 kg and weight of frame 15
kg) : With Sewer bricks conforming to IS : 4885
-
-
-
SOR 17.27.1 Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 sand) including 500x450 mm precast R.C.C. horizontal grating with frame complete as
per standard design :
-
-
-
SOR 18.52.1 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore.
-
-
-
SOR 18.56.1 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore.
-
-
-
SOR 17.78.1 Providing and fixing C.P. brass grating of approved quality and make conforming to IS:specification. 100 mm dia.
-
-
-
SOR 18.34.1 Providing and fixing CPVC gate valve with knob of approved quality.
-
-
-
25 mm nominal bore
-
-
-
32 mm nominal bore
-
-
-
SOR 17.64.2.1 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings Complete. Flexible pipe 32 mm dia
-
-
-
SOR 17.1.1 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or S trap, uPVC P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.
-
-
-
SOR 17.11.4 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap.
-
-
-
SOR 17.26 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm or 340x410x265mm sizes respectively.
-
-
-
SOR 18.49 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
-
-
-
ELECTRICAL WORK
-
-
-
S.O.R Item No.4.1.1 Point wiring (excluding metallic switch box & sheet but including switches,sockes,lamp, holders,ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for
-
-
-
Light Point/ Fan Point
-
-
-
Short Point
-
-
-
Medium Point
-
-
-
Long Point
-
-
-
S.O.R Item No.4.2 Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. Socket outlet point with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board .
-
-
-
S.O.R Item No.4.3.1 Wiring for circuit wiring with PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size etc. as required as per specification
-
-
-
2X2.5 Sq.mm
-
-
-
S.O.R Item No. 9.1.1.3 Point wiring (excluding metallic switch box & sheet ) for 3 Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Concealed rigid P.V.C Conduit (HMS) ISI Marked of suitable size etc. with 16 Amp. F.T. Switch & Socket / S.S.Combined 6/16 Amp. of ISI Marked and 4 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit as per specification for Same board switch socket 6/16 Amp
-
-
-
Long Point
2
3356
1678
S.O.R Item No. 18.2 Supplying and fixing of approved make modular type metal box with modular frame/ base plate and cover plate including fixing in concealed / surface excluding switch,socket etc. as required for:-
-
-
-
S.O.R Item No. 18.2.3 4 MODULE
-
-
-
S.O.R Item No. 18.2.4 6 MODULE
-
-
-
S.O.R Item No. 18.2.5 8/9 MODULE
-
-
-
S.O.R Item No. 19.1.2.1 Supplying and drawing single core PVC insulated cable FR with copper multi strand conductor ISI marked in existing rigid PVC Casing-N-Capping / conduit in surface or concealed as per specification.
-
-
-
1x2.5 Sq. MM
-
-
-
S.O.R Item No.27.8.1.2 Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS : 8828 : 1996, IEC : 60898 :2002 but without enclosures :-
-
-
-
SINGLE POLE (SP)
-
-
-
6 Amp to 32 Amp Rating
-
-
-
S.O.R Item No.27.10.1.1 Supplying of MCB Isolators suitable for 240/415 Volts, 50 Hz AC supply with KA value rating 10 kA of approved make confirming to IS :13947-Part III : 1993 & IEC : 60947- 3:2001 (without enclosures )
-
-
-
DOUBLE POLE
-
-
-
40 Amps.
-
-
-
S.O.R Item No.27.11.5 Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of Bus bar, Neutral bar, Earth bar & two earth terminals etc. complete as per IS:13032 ( exclusive of MCB & isolator )-
-
-
-
8 way Double Door IP 43 protection
-
-
-
S.O.R Item No. 28.4.1 Fixing of MCB /MCCB/ Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (Labour only )
-
-
-
MCB / Isolator SP/DP
-
-
-
S.O.R Item No. 28.8.1 Labour charges for fixing sheet steel enclosures, MCB DB flush mounting type, as per accepted practice, duly embedded and end plate completely flushed in wall, cable connection etc.complete :-
-
-
-
FOR S.No :-
-
-
-
27.7.1 to 27.7.7 ; 27.8.1 to 27.8.3 & 27.9.1,
-
-
-
S.O.R Item No. 29.7.5 Supply and fixing in position LED lamp
of approved make
-
-
-
9 Watt
-
-
-
S.O.R Item No. 29.25.2 Supplying and fixing of approved make step type Modular electronic Fan regulator including connection etc. as required on existing board
-
-
-
100 Watt (2 module)
-
-
-
S.O.R Item No.30.1.2 Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete of approved as required confirming to IS :374/1979 with upto date ammendments.
-
-
-
Ceiling Fan (5 star & ISI)-1200 mm Sweep
-
-
-
S.O.R Item No. 31.3.4 Supply and fixing Led tube rod comprising of LED tube with non integral / integral driver, 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy 80 lm/W. LED driver PF 0.95 & THD 20%. The colour rendering index of LED light should be more than 70. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer manadatory i/c connection wire, testing etc. to complete the job. 2 Yrs Guarantee certificate from manufacturer.
-
-
-
1 X 20/22W, Intregral
-
-
-
S.O.R Item No. 31.22 Supplying fixing and testing of approved and suitable make LED driver for an existing LED
street light.
-
-
-
90Watt, color temp 3000-6500k
2
3366
1683
S.O.R Item No. 30.6.3 Supplying, erecting and testing of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250 complete connection and including, frame bolt/anchor hole fasteners etc. complete finished and as
required.
-
-
-
450mm sweep RPM 900 / 1400
1
3460
3460
S.O.R Item No. 41.1.4.3 Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI
marked with alu. stranded /solid conductor
-
-
-
Armoured 2 core
-
-
-
6 sq. mm.
37.9
3297
87
S.O.R Item No. 41.24 Laying of one number armoured / unarmoured power cable 1.1 KV grade of size not exceeding 25 sq. mm in the existing masonry open duct as required.
37.9
606
16
S.O.R. Item No.3.3 Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location with all lifts and lead upto 1000m as per relevent clauses of section-300 of specification.
-
-
-
S.O.R. Item No.3.10 Construction of embankment with approved material having CBR7 obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-1, 300-2 and as per relevant clauses of section-300.
-
-
-
S.O.R. Item No.4.12 Crusher Run Macadam Sub Base/Base Course Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor grader, watering and compacting with a vibratory roller to clause 410 to form a layer of sub-base/Base in accordance to Table No. 400-14, 400-15 and as per clause of section 407 of specifications. (i) For 53 mm maximum size
-
-
-
S.O.R. Item No.4.8 (i) (B) Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density as per clause 404 of specification. (i) Grading- I (63 to 45mm) (b) Using Screening Type-B (11.2mm Agg.)
-
-
-
S.O.R. Item No.4.8 (ii) (A) Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density as per clause 404 of specification. (ii) Grading- II (53 to 22.4mm)
(a) Using Screening Type-B (11.2mm Agg.)
-
-
-
S.O.R. Item No.4.13 Construction of Shoulders with approved material/selected soil i/c excavation all lifts & leads i/c grading to required slope & camber of 4% and compacting using vibratory roller of 80 to 100 kN static weight to meet requirement as per relevant clause of 400.
Hard Shoulders (CBR value 12)
-
-
-
Grand Total (A+B)
4163806.38
-
-
FOR 5 PLACE
20819030
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements